Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
JACC Case Rep ; 29(15): 102391, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39157549

RESUMO

A 66-year-old woman with a complex medical history underwent transcatheter mitral valve replacement (TMVI) owing to mitral insufficiency. Risk factors and noncompliance led to bioprosthetic valve thrombosis (BPVT) within 3 years. Emergent surgery indicated by an ad hoc heart team successfully managed the situation, showcasing challenges in BPVT management after TMVI.

2.
J Clin Med ; 13(15)2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39124557

RESUMO

Transesophageal echocardiography (TEE) is widely used in cardiac surgery and interventional cardiology and is often an indispensable tool, giving supportive anatomical understanding and smooth guidance in both settings. Despite it being considered safe, fatal complications can commonly occur after a TEE examination in cardiac surgery operating rooms and catheterization laboratories. Currently, there is a lack of awareness of the scale of the problem, as there are only small amounts of data available, mainly derived from the surgical literature. This review summarizes the main predisposing factors for TEE-associated complications (classified as patient and procedure-related) and the main preventive strategies. We aim to apply preventive strategies more broadly, especially to patients at high risk of developing TEE-related serious adverse events.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38970594

RESUMO

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

4.
J Clin Med ; 13(14)2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39064227

RESUMO

Background/Objectives: Previous trials reported comparable results with PASCAL and earlier MitraClip generations. Limited comparative data exist for more contemporary MitraClip generations, particularly the large MitraClip XT(R/W). We aimed to evaluate acute and 30-day outcomes in patients undergoing mitral valve transcatheter edge-to-edge repair (M-TEER) with one of the large devices, either PASCAL P10 or MitraClip XT(R/W) (3rd/4th generation). Methods: A total of 309 PASCAL-treated patients were matched by propensity score to 253 MitraClip-treated patients, resulting in 200 adequately balanced pairs. Procedural, clinical, and echocardiographic outcomes were collected for up to 30 days, including subgroup analysis for mitral regurgitation (MR) etiologies. Results: PASCAL and MitraClip patients were comparable regarding age (80 vs. 79 years), sex (female: 45.5% vs. 50.5%), and MR etiology (degenerative MR: n = 94, functional MR [FMR]: n = 96, mixed MR: n = 10 in each group). Technical success rates were comparable (96.5% vs. 96.0%; p > 0.999). At discharge, the mean gradient was higher (3.3 mmHg vs. 3.0 mmHg; p = 0.038), and the residual mitral valve orifice area was smaller in MitraClip patients (3.0 cm2 vs. 2.3 cm2; p < 0.001). At discharge, the reduction to MR ≤ 2+ was comparable (92.4% vs. 87.8%; p = 0.132). However, reduction to MR ≤ 1+ was more frequently observed in PASCAL patients (67.7% vs. 56.6%; p = 0.029), driven by the FMR subgroup (74.0% vs. 60.0%; p = 0.046). No difference was observed in 30-day mortality (p = 0.204) or reduction in NYHA-FC to ≤II (p > 0.999). Conclusions: Both M-TEER devices exhibited high and comparable rates of technical success and MR reduction to ≤2+. PASCAL may be advantageous in achieving MR reduction to ≤1+ in patients with FMR.

5.
Front Cardiovasc Med ; 11: 1223588, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38468721

RESUMO

Background: There are different types of transcatheter mitral valve repair (TMVr) currently in clinical use, including leaflet approximation, annular cinching, and restoration of the chordal apparatus of the mitral valve (MV). While the concomitant combination (COMBO) therapy of mitral transcatheter edge-to-edge repair (M-TEER) with another TMVr concept has been proven feasible, potentially offering patient-tailored treatment for severe mitral regurgitation (MR), a comparison with M-TEER alone has not been made. Aims: To evaluate the procedural and clinical outcome of COMBO therapies compared with M-TEER alone. Methods: We included consecutive patients undergoing COMBO and M-TEER between March 2015 and April 2018 at our Heart Valve Center, while excluding patients presenting a case of redo or with previous MV surgery. Procedural outcomes and all-cause mortality were compared between COMBO therapy vs. M-TEER alone. Results: A total of 357 patients (mean age 78.9 ± 7.0 years, 53.2% male, M-TEER n = 322, COMBO n = 35; COMBO: MitraClip and the Carillon mitral contour system n = 26, MitraClip and Cardioband n = 5, and MitraClip and NeoChord n = 4) were analyzed. Patients with COMBO therapy had larger left chamber sizes, a lower left ventricular systolic ejection fraction (LVEF; COMBO: 37.4 ± 13.8%, M-TEER: 47.9 ± 14.3%, p < 0.001), and a more severe MR grade (p < 0.001). There were no significant differences in the prevalence of residual MR ≧2+. However, the need for re-intervention, always employing M-TEER, was more common in the COMBO group. During a mean 3.6-year long-term follow-up, there was no significant difference of all-cause mortality between both groups (Log rank p = 0.921). Conclusions: COMBO therapy may still be a beneficial therapy option for patients with severe MR who already have a more dilated left ventricle (LV), a more severe MR, and a more pronounced LV systolic dysfunction. The higher need for re-intervention in the COMBO group may signal more complex anatomies and possibly underlines the necessity of treating significant MR earlier. Future research is required to establish the COMBO approach as a toolbox-like treatment option, thus offering a patient-tailored approach depending on the individual anatomy and pathology.

6.
Int J Cardiol ; 405: 131939, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38458388

RESUMO

BACKGROUND: Advances in imaging have led to procedural optimization of left atrial appendage closure (LAAC). Contrast-free approaches, guided merely by echocardiography, have been established, however data on this topic remains scarce. In this analysis, we assessed contrast-free procedural results with the LAMBRE LAAC device. METHODS: The multicenter retrospective BoBoMa (Bonn/Bordeaux/Mainz)-Registry included a total of 118 patients that underwent LAAC with LAMBRE devices omitting contrast-dye. Baseline and echocardiographic characteristics as well as intra- and postprocedural complications and outcomes were assessed. RESULTS: Patients were at a mean age of 77.5 ± 7.5 years with high thromboembolic and bleeding risk (CHADS-VASc-score 4.6 ± 1.4, HAS-BLED-score 3.7 ± 1.0, respectively). Renal function was impaired with a mean glomerular filtration rate (GFR) of 50 ± 22 ml/min. Mean procedural time was 47.2 ± 37.5  minutes with a mean radiation dose of 4.75 ± 5.25 Gy*cm2. Device success, defined as proper deployment in a correct position, was achieved in 97.5% (115/118) of cases with repositioning of the occluder in 7.6% (9/118) and resizing in 3.4% (4/118) of cases. No relevant peri-device leakage (>3 mm) was observed with 42% of occluders being implanted in an ostial position. Periprocedural complications occurred in 6.8% (8/118) of cases, including two cases of device embolization and one case of clinically-relevant pericardial effusion requiring surgical intervention. Other complications included pericardial effusion (2.5%, 3/118) and vascular access site complications (1.7%, 2/118). CONCLUSION: Echocardiography-guided contrast-free LAAC using the LAMBRE device is safe and feasible. Further prospective studies including the direct comparison of devices as well as imaging techniques are warranted in contrast-free LAAC.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Humanos , Apêndice Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Masculino , Feminino , Idoso , Estudos Retrospectivos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Idoso de 80 Anos ou mais , Sistema de Registros , Resultado do Tratamento , Ecocardiografia Transesofagiana/métodos , Meios de Contraste/administração & dosagem , Seguimentos
7.
Eur Heart J Case Rep ; 8(2): ytae060, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38374984

RESUMO

Background: Patients requiring coronary intervention after acute myocardial infarction, with decompensated heart failure and multiple co-morbidities, present a challenging clinical scenario. Addressing such high-risk cases has been a marked increase in the simultaneous support using microaxial flow pump devices, providing a crucial haemodynamic support during procedures. Case summary: We report the case of a 58-year-old man, with a non-ST-segment elevation myocardial infarction in the context of a peripheral vascular surgery. Echocardiography revealed severely reduced left ventricular function and cardiac magnetic resonance imaging demonstrated transmural scars in all but left anterior descending artery area. The patient was of extreme high surgical risk due to the multiple co-morbidities, acute decompensation heart failure, and peripheral artery disease, and, therefore, the heart team preferred protected percutaneous coronary intervention (PCI) over coronary artery bypass graft for revascularization. The peripheral artery disease included severely calcified ascending aorta, occlusions of both femoral arteries, the left subclavian artery, and the right radial artery. Taken together, the heart team agreed on a hybrid approach with surgical implantation of Impella 5.0 via the left subclavian artery, by a single-access technique. Following the intervention procedure, haemostasis of the vascular prosthesis was achieved by an angio-seal technique without complications. The patient recovered satisfactorily, with improved left ventricular function, and discharged 10 days post-procedure. Discussion: The single-access high-risk PCI technique offers a standardized approach for microaxial flow pump devices such as Impella 5.0 and PCI. The subclavian artery as a single-access route for high-risk PCI has demonstrated safety and efficacy.

8.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38099912

RESUMO

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Masculino , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Idoso , Fatores de Risco , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Tempo , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Estudos de Viabilidade , Medição de Risco , Desenho de Prótese , Ecocardiografia Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA