Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
2.
JAMA Oncol ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38635232

RESUMO

This case series reports durable remissions in 2 patients with relapsed/refractory B-cell acute lymphoblastic leukemia treated with allogeneic bispecific CD19/CD22-targeting chimeric antigen receptor T cells.

3.
Diagnostics (Basel) ; 14(7)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38611589

RESUMO

A 61-year-old patient was diagnosed with a left-sided falx meningioma. Histopathological analysis following extirpation showed a meningothelial meningioma ZNS WHO grade 1 with sparse mitoses. Over the course of 12 years, the patient received irradiation (54.0 Gy), peptide radio-receptor therapy (177Lu-DOMITATE) and targeted therapy (mTOR inhibitor). Follow-up imaging revealed an increased size of the residual tumor. Due to increased liver function parameters, imaging of the liver was performed, showing widespread space-occupying lesions with atypical appearance. Biopsy revealed metastasis of the meningioma, now with 2.7 mitoses/mm2, necrosis and homozygous CDKN2A/B deletion, corresponding to an anaplastic CNS meningioma WHO grade 3. A second small meningioma on the left petroclival side has been consistent in size over 12 years. Metastatic meningiomas pose a pertinent clinical challenge due to poor prognosis. The lung, bone, liver and cervical lymph nodes are the most common sites of extracranial metastasis. According to the World Health Organization criteria, the most important predictive factor for recurrence and metastasis is the tumor grade.

5.
Cancer Med ; 12(24): 22047-22055, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38063340

RESUMO

INTRODUCTION: Glioblastoma (GBM) is a tumor with rapid growth and a possible relationship to elevated intracranial pressure (ICP). High ICP may not always be associated with clinical signs. A non-invasive technique for assessment of ICP is measuring the optic nerve sheath diameter (ONSD). Identifying patients who need immediate intervention is of importance in neuro-oncological care. The goal of this study is to assess the available magnetic resonance imaging (MRI) of patients with GBM with respect to pre- and postoperative ONSD. METHODS AND MATERIALS: Retrospective data analysis was performed on all patients operated for GBM at a tertiary care center between 2010 and 2020. Two pre and one postoperative MRI had to be available. Clinical data and ONSD at multiple time points were analyzed and correlated, as well as preoperative volumetrics. RESULTS: Sixty-seven patients met the inclusion criteria. Clinical signs of elevated ICP were seen in 25.4% (n = 17), while significant perifocal edema was present in 67.2% (n = 45) of patients. Clinical signs of preoperatively elevated ICP were associated with significantly elevated ONSD at diagnosis (p < 0.001) as well as preoperative tumor volume (p < 0.001). Significant perifocal edema at the time of diagnosis was associated with elevated ONSD (p = 0.029) and higher tumor volume (p = 0.003). In patients with significant edema, ONSD increased significantly between preoperative MRIs (p = 0.003/005). In patients with clinical signs of raised ICP, ONSD also increased, whereas it was stable in asymptomatic patients (yes: 5.01+/-4.17 to 5.83+/-0.55 mm, p = 0.010, no: 5.17+/-0.46 mm to 5.38+/-0.41 mm, p = 0.81). A significant increase of ONSD from diagnosis to preoperative MRI and a significant decrease until 3 months postoperatively were observed (p < 0.001). CONCLUSIONS: ONSD might help identify high ICP in patients with GBM. In this first-of-its kind study, we observed a significant increase of ONSD preoperatively, likely associated with edema. Postoperatively, ONSD decreased significantly until 3 months after surgery and increased again at 12 months. Further prospective data collection is warranted.


Assuntos
Glioblastoma , Glioma , Hipertensão Intracraniana , Humanos , Estudos Retrospectivos , Nervo Óptico/diagnóstico por imagem , Nervo Óptico/patologia , Pressão Intracraniana/fisiologia , Hipertensão Intracraniana/diagnóstico , Hipertensão Intracraniana/etiologia , Hipertensão Intracraniana/patologia , Glioma/patologia , Glioblastoma/patologia , Edema/patologia , Ultrassonografia/métodos
6.
Nervenarzt ; 94(12): 1087-1096, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-37848647

RESUMO

BACKGROUND: Nerve injuries are a frequent problem in routine clinical practice and require intensive interdisciplinary care. OBJECTIVE: The current status of imaging to confirm the diagnosis of nerve injuries is described. The role of high-resolution ultrasound and magnetic resonance imaging (MRI) in the diagnostics and follow-up of peripheral nerve injuries is elaborated. MATERIAL AND METHODS: Review of the current state of imaging to confirm the diagnosis of nerve injuries. RESULTS: Depending on the suspected site of damage, the primary domain of magnetic resonance (MR) imaging (MR neurography) is injuries in the region of the spine, nerve roots, brachial plexus and lumbar plexus, pelvis and proximal thigh. In contrast, in other peripheral nerve lesions of the extremities the advantages of high-resolution nerve ultrasound in a dynamic setting predominate. The MR neurography is indicated here, especially in the frequent bottleneck syndromes and only in very isolated and selected cases. CONCLUSION: In addition to a correct anatomical assignment, the timely decision for a possible intervention and the appropriate concomitant treatment are an important basis for a favorable prognosis of nerve injuries. Imaging techniques should therefore be used early in the diagnostics and follow-up controls of peripheral nerve injuries.


Assuntos
Traumatismos dos Nervos Periféricos , Humanos , Traumatismos dos Nervos Periféricos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia , Síndrome
7.
Vasc Med ; 28(6): 592-603, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37792749

RESUMO

The spectrum of venous thromboembolic (VTE) disease encompasses both acute deep venous thrombosis (DVT) and chronic postthrombotic changes (CPC). A large percentage of acute DVT patients experience recurrent VTE despite adequate anticoagulation, and may progress to CPC. Further, the role of iliocaval venous obstruction (ICVO) in lower-extremity VTE has been increasingly recognized in recent years. Imaging continues to play an important role in both acute and chronic venous disease. Venous duplex ultrasound remains the gold standard for diagnosing acute VTE. However, imaging of CPC is more complex and may involve computed tomography, magnetic resonance, contrast-enhanced ultrasound, or intravascular ultrasound. In this narrative review, we aim to discuss the full spectrum of venous disease imaging for both acute and chronic venous thrombotic disease.


Assuntos
Síndrome Pós-Trombótica , Tromboembolia Venosa , Trombose Venosa , Humanos , Tromboembolia Venosa/diagnóstico por imagem , Veias , Trombose Venosa/diagnóstico por imagem , Extremidade Inferior/irrigação sanguínea , Doença Crônica , Doença Aguda
8.
Cardiovasc Diagn Ther ; 13(1): 133-146, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36864951

RESUMO

Background and Objective: Vascular calcification (VC) and resulting vascular disease is one of the major causes of cardiovascular morbidity and mortality in patients with chronic kidney disease (CKD). CKD itself is increasingly recognized as a risk factor for cardiac and peripheral arterial disease (PAD). This paper examines the atherosclerotic plaque composition and specific endovascular considerations in the end stage renal disease (ESRD) patients. The literature was reviewed regarding the current status of medical and interventional management arteriosclerotic disease in patients with CKD. Lastly, three representative cases displaying typical endovascular treatment options are provided. Methods: A literature search was performed in PubMed covering publications up to September 2021 as well as discussion with experts in the field. Key Content and Findings: The high prevalence of atherosclerotic lesions in patients with chronic renal failure and high (re-)stenosis cause problems in the medium and long term as vascular calcium load represents one of the most widely encountered predictors of failure of endovascular treatment of PAD and future cardiovascular events (e.g., coronary calcium score). Patients with CKD also suffer from a greater risk for major vascular adverse events in general and worse revascularization outcomes following peripheral vascular intervention. A correlation between calcium burden and drug-coated balloon (DCB) performance has been established for PAD necessitating the need for different tools to cope with vascular calcium such as endoprosthesis or braided stents. Patients with CKD are at a higher risk of developing contrast-induced nephropathy (CIN). In addition to recommendations such as the administration of intravenous fluids, carbon dioxide (CO2) angiography is one option to potentially provide an effective and safe alternative both to iodine-based contrast media allergy and to the use of iodine-based contrast media in patients with CKD. Conclusions: Management and endovascular procedures of patients with ESRD are complex. In the course of time, new endovascular therapy methods have been developed such as directional atherectomy (DA) and the so-called "pave-and-crack" technique to deal with high vascular calcium burden. Besides interventional therapy, vascular patients with CKD benefit from aggressive medical management.

9.
Neuroimage Clin ; 36: 103213, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36270162

RESUMO

Spinal diffusion tensor imaging (sDTI) is still a challenging technique for selectively evaluating anatomical areas like the pyramidal tracts (PT), dorsal columns (DC), and anterior horns (AH) in clinical routine and for reliably quantifying white matter anisotropy and diffusivity. In neurodegenerative diseases, the value of sDTI is promising but not yet well understood. The objective of this prospective, single-center study was to evaluate the long fiber tract degeneration within the spinal cord in normal aging (n = 125) and to prove its applicability in pathologic conditions as in patients with molecular genetically confirmed hereditary spastic paraplegias (HSP; n = 40), a prototypical disease of the first motor neuron and in some genetic variants with affection of the dorsal columns. An optimized monopolar Stejskal-Tanner sequence for high-resolution, axial sDTI of the cervical spinal cord at 3.0 T with advanced standardized evaluation methods was developed for a robust DTI value estimation of PT, DC, and AH in both groups. After sDTI measurement at C2, an automatic motion correction and an advanced semi-automatic ROI-based, standardized evaluation of white matter anisotropy and diffusivity was performed to obtain regional diffusivity measures for PT, DC, and AH. Reliable and stable sDTI values were acquired in a healthy population without significant decline between age 20 and 65. Reference values for PT, DC, and AH for fractional anisotropy (FA), mean diffusivity (MD), and radial diffusivity (RD) were established. In HSP patients, the decline of the long spinal fiber tracts could be demonstrated by diffusivity abnormalities in the pyramidal tracts with significantly reduced PTFA (p < 0.001), elevated PTRD (p = 0.002) and reduced PTMD (p = 0.003) compared to healthy controls. Furthermore, FA was significantly reduced in DCFA (p < 0.001) with no differences in AH. In a genetically homogeneous subgroup of SPG4 patients (n = 12) with affection of the dorsal columns, DCRD significantly correlated with the overall disease severity as measured by the Spastic Paraplegia Rating Scale (SPRS) (r = - 0.713, p = 0.009). With the most extensive sDTI study in vivo to date, we showed that axial sDTI combined with motion correction and advanced data post-processing strategies enables robust measurements and is ready to use, allowing recognition and quantification of disease- and age-related changes of the PT, DC, and AH. These results may also encourage the usage of sDTI in other neurodegenerative diseases with spinal cord involvement to explore its capability as selective biomarkers.


Assuntos
Imagem de Tensor de Difusão , Substância Branca , Animais , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Imagem de Tensor de Difusão/métodos , Estudos Prospectivos , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Anisotropia , Tratos Piramidais/diagnóstico por imagem
10.
Artigo em Inglês | MEDLINE | ID: mdl-34952851

RESUMO

INTRODUCTION: Transjugular intrahepatic portosystemic shunt (TIPS) placement is a well-established but technically challenging procedure for the management of sequelae of end-stage liver disease. Performed essentially blindly, traditional fluoroscopically guided TIPS placement requires multiple needle passes and prolonged radiation exposure to achieve successful portal venous access, thus increasing procedure time and the risk of periprocedural complications. Several advanced image-guided portal access techniques, including intracardiac echocardiography (ICE)-guided access, cone-beam CT (CBCT)-guided access and wire-targeting access techniques, can serve as alternatives to traditional CO2 portography-based TIPS creation. METHODS: A literature search was performed on the electronic databases including MEDLINE and Embase, from 2000 to the present to identify all relevant studies. The reference list also included studies identified manually, and studies referenced for other purposes. FINDINGS: The main benefit of these advanced access techniques is that they allow the operator to avoid essentially blind portal punctures, and the ability to visualise the target, thus reducing the number of required needle passes. Research has shown that ICE-guided access can decrease the radiation exposure, procedure time and complication rate in patients undergoing TIPS placement. This technique is particularly useful in patients with challenging portal venous anatomy. However, ICE-guided access requires additional equipment and possibly a second operator. Other studies have shown that CBCT-guided access, when compared with traditional fluoroscopy-guided access, provides superior visualisation of the anatomy with similar amount of radiation exposure and procedure time. The wire-targeting technique, on the other hand, appears to offer reductions in procedure time and radiation exposure by enabling real-time guidance. However, this technique necessitates percutaneous injury to the liver parenchyma in order to place the target wire. CONCLUSION: Advanced portal access techniques have certain advantages over the traditional fluoroscopically guided TIPS access. To date, few studies have compared these advanced guided access options, and further research is required.


Assuntos
Derivação Portossistêmica Transjugular Intra-Hepática , Fluoroscopia/métodos , Humanos , Veia Porta/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Portografia , Punções/métodos
11.
Cardiovasc Intervent Radiol ; 44(9): 1403-1413, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34021375

RESUMO

PURPOSE: To evaluate the value of dual-phase parenchymal blood volume (PBV) C-arm mounted cone-beam-CT (CBCT) to enable assessment of radiopaque, doxorubicin-loaded drug-eluting embolics (rDEE) based on the visual degree of embolization, embolic density and residual tumor perfusion as early predictors for tumor recurrence after transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC). MATERIAL AND METHODS: Thirty patients (50 HCCs) were prospectively enrolled, underwent cross-sectional imaging before and after TACE using 100-300 µm rDEE and had regular follow-up examinations. Directly before and after the TACE procedure, PBV-CBCT was acquired. The response was evaluated and compared to visual degree of embolization (DE) and embolic density (ED) of rDEE deposits, as well as the presence of residual tumor perfusion (RTP) derived from PBV-CBCT. Outcome was assessed by mid-term tumor response applying mRECIST and patient survival after 12 months. RESULTS: RTP was detected in 16 HCCs and correlated negatively with DE (p = .03*) and ED (p = .0009*). The absence of RTP significantly improved lesion-based mid-term response rates regarding complete response (CR, 30/34 (88%) vs 2/16 (12.5%), p = .0002*), lesion-based complete response rate was 75% (21/28) for DE ≥ 50% vs. 50% (11/22) for DE < 50% (p = .08) and 82% (27/33) for ED ≥ 2 vs. 29% for ED < 2 (5/17), p = .005*). Thirteen patients were treated with re-TACE within 12 months, 11 of which had shown RTP. 12-month survival rate was 93%. CONCLUSION: Residual tumor perfusions as assessed by PBV-CBCT during rDEE-TACE proved to be the best parameter to predict mid-term response. "Level of Evidence: Level 3".


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/terapia , Neoplasia Residual/diagnóstico por imagem , Perfusão , Preparações Farmacêuticas , Resultado do Tratamento
12.
Invest Radiol ; 54(12): 737-743, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31206392

RESUMO

PURPOSE: The aim of this study was to demonstrate the feasibility of hepatic perfusion imaging using dynamic contrast-enhanced (DCE) golden-angle radial sparse parallel (GRASP) magnetic resonance imaging (MRI) for characterizing liver parenchyma and hepatocellular carcinoma (HCC) before and after transarterial chemoembolization (TACE) as a potential alternative to volume perfusion computed tomography (VPCT). METHODS AND MATERIALS: Between November 2017 and September 2018, 10 patients (male = 8; mean age, 66.5 ± 8.6 years) with HCC were included in this prospective, institutional review board-approved study. All patients underwent DCE GRASP MRI with high spatiotemporal resolution after injection of liver-specific MR contrast agent before and after TACE. In addition, VPCT was acquired before TACE serving as standard of reference. From the dynamic imaging data of DCE MRI and VPCT, perfusion maps (arterial liver perfusion [mL/100 mL/min], portal liver perfusion [mL/100 mL/min], hepatic perfusion index [%]) were calculated using a dual-input maximum slope model and compared with assess perfusion measures, lesion characteristics, and treatment response using Wilcoxon signed-rank test. To evaluate interreader agreement for measurement repeatability, the interclass correlation coefficient (ICC) was calculated. RESULTS: Perfusion maps could be successfully generated from all DCE MRI and VPCT data. The ICC was excellent for all perfusion maps (ICC ≥ 0.88; P ≤ 0.001). Image analyses revealed perfusion parameters for DCE MRI and VPCT within the same absolute range for tumor and liver tissue. Dynamic contrast-enhanced MRI further enabled quantitative assessment of treatment response showing a significant decrease (P ≤ 0.01) of arterial liver perfusion and hepatic perfusion index in the target lesion after TACE. CONCLUSIONS: Dynamic contrast-enhanced GRASP MRI allows for a reliable and robust assessment of hepatic perfusion parameters providing quantitative results comparable to VPCT and enables characterization of HCC before and after TACE, thus posing the potential to serve as an alternative to VPCT.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idoso , Algoritmos , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Estudos de Viabilidade , Feminino , Humanos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Masculino , Imagem de Perfusão/métodos , Estudos Prospectivos
13.
J Vasc Interv Radiol ; 30(3): 380-389.e4, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30819480

RESUMO

PURPOSE: To compare different imaging techniques (volume perfusion CT, cone-beam CT, and dynamic gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced dynamic contrast-enhanced MR imaging with golden-angle radial sparse parallel MR imaging) in evaluation of transarterial chemoembolization of hepatocellular carcinoma (HCC) using radiopaque drug-eluting embolics (DEE). MATERIALS AND METHODS: MR imaging and CT phantom investigation of radiopaque DEE was performed. In the clinical portion of the study, 13 patients (22 HCCs) were prospectively enrolled. All patients underwent cross-sectional imaging before and after transarterial chemoembolization using 100-300 µm radiopaque DEE. Qualitative assessment of images using a Likert scale was performed. RESULTS: In the phantom study, CT-related beam-hardening artifacts were markedly visible at a concentration of 12% (v/v) radiopaque DEE; MR imaging demonstrated no significant detectable signal intensity changes. Imaging obtained before transarterial chemoembolization showed no significant difference regarding tumor depiction. Visualization of tumor feeding arteries was significantly improved with volume perfusion CT (P < .001) and cone-beam CT (P = .002) compared with MR imaging. Radiopaque DEE led to significant decrease in tumor depiction (P = .001) and significant increase of beam-hardening artifacts (P = .012) using volume perfusion CT before versus after transarterial chemoembolization. Greater residual arterial tumor enhancement was detected with MR imaging (10 HCCs) compared with volume perfusion CT (8 HCCs) and cone-beam CT (6 HCCs). CONCLUSIONS: Using radiopaque DEE, the imaging modalities provided comparable early treatment assessment. In HCCs with dense accumulation of radiopaque DEE, treatment assessment using volume perfusion CT or cone-beam CT may be impaired owing to resulting beam-hardening artifacts and contrast stasis. Dynamic contrast-enhanced MR imaging may add value in detection of residual arterial tumor enhancement.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Doxorrubicina/administração & dosagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Álcool de Polivinil/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Antibióticos Antineoplásicos/efeitos adversos , Artefatos , Carcinoma Hepatocelular/patologia , Quimioembolização Terapêutica/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/instrumentação , Meios de Contraste/administração & dosagem , Doxorrubicina/efeitos adversos , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/instrumentação , Masculino , Microesferas , Pessoa de Meia-Idade , Imagem de Perfusão/instrumentação , Imagens de Fantasmas , Álcool de Polivinil/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento
14.
J Med Ultrason (2001) ; 46(1): 81-88, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29948475

RESUMO

PURPOSE: To investigate whether liver stiffness measured by acoustic radiation force impulse (ARFI) sonoelastography always correlates with the liver perfusion parameters quantified by perfusion CT in patients with known liver cirrhosis. METHODS: Sonoelastography and perfusion CT were performed in 50 patients (mean age 65.5; range 45-87 years) with liver cirrhosis, who were classified according to Child-Pugh into class A (30/50, 60%), B (17/50, 34%), and C (3/50, 6%). For standardized ARFI measurements in the left liver lobe at a depth of 4 cm, a convex 6-MHz probe was used. CT examinations were performed using 80 kV, 100 mAs, and 50 ml of iodinated contrast agent injected at 5 ml/s. Using standardized region-of-interest measurements, we quantified arterial, portal venous, and total liver perfusion. RESULTS: There was a significant linear correlation between tissue stiffness and arterial liver perfusion (p = 0.015), and also when limiting the analysis to patients with histology (p = 0.019). In addition, there was a positive correlation between the total blood supply (arterial + portal-venous liver perfusion) to the liver and tissue stiffness (p = 0.001; with histology, p = 0.027). Shear wave velocity increased with higher Child-Pugh stages (p = 0.013). CONCLUSION: The degree of tissue stiffness in cirrhotic livers correlates expectedly-even if only moderately-with the magnitude of arterial liver perfusion and total liver perfusion. As such, liver elastography remains the leading imaging tool in assessing liver fibrosis.


Assuntos
Cirrose Hepática/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Fígado/fisiopatologia , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Veia Porta/diagnóstico por imagem , Veia Porta/fisiopatologia , Estudo de Prova de Conceito , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
15.
Tex Heart Inst J ; 44(4): 252-259, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28878578

RESUMO

Using cardiac magnetic resonance, we tested whether a single-breath-hold approach to cardiac functional evaluation was equivalent to the established multiple-breath-hold method. We examined 39 healthy volunteers (mean age, 31.9 ± 11.4 yr; 22 men) by using 1.5 T with multiple breath-holds and our proposed single breath-hold. Left ventricular and right ventricular ejection fractions (LVEF and RVEF), LV and RV end-diastolic volumes (LVEDV and RVEDV), and LV myocardial mass (LVMM) were compared by using Bland-Altman plots; LVEF and RVEF were tested for equivalence by inclusion of 95% confidence intervals (CIs). Equivalence of the methods was assumed within the range of -5% to 5%. In the multiple- versus the single-breath-hold method, LVEF was 0.62 ± 0.05 versus 0.62 ± 0.04, and RVEF was 0.59 ± 0.06 versus 0.59 ± 0.07. The mean difference in both methods was -0.2% (95% CI, -1 to 0.6) for LVEF and 0.3% (95% CI, -0.8 to 1.5) for RVEF. The mean differences between methods fit within the predetermined range of equivalence, including the 95% CI. The mean relative differences between the methods were 3.8% for LVEDV, 4.5% for RVEDV, and 1.6% for LVMM. Results of our single-breath-hold method to evaluate LVEF and RVEF were equivalent to those of the multiple-breath-hold technique. In addition, LVEDV, RVEDV, and LVMM showed low bias between methods.


Assuntos
Suspensão da Respiração , Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Função Ventricular Esquerda , Função Ventricular Direita , Adulto , Feminino , Voluntários Saudáveis , Coração/fisiologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto Jovem
16.
Eur J Radiol ; 89: 215-220, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28267542

RESUMO

OBJECTIVE: To find out, if ultrasound elastography of hepatocellular carcinoma (HCC) can predict patterns of tumor perfusion in volume perfusion computed tomography (VPCT). MATERIAL AND METHODS: 25 consecutive patients (mean age, 68.9; range, 51-85 years) with liver cirrhosis suspected of HCC underwent VPCT and acoustic radiation force impulse (ARFI) elastography the same day. Quantitative elasticity values were registered, while blood flow (BF), blood volume (BV) and hepatic perfusion index (HPI) of the HCC lesions were calculated. Additionally, we identified histologic WHO grading, lesion size and localization. The Siemens Acuson S 3000 HELX-System with Virtual Touch™-Software and Siemens Somatom Definition Flash with Syngo® software were used. RESULTS: A total of 43 HCC lesions were assessed. Mean shear wave velocity was 2.6m/s (range, 1.1-4.3m/s). There was no significant linear correlation between the elasticity values and BF (p=0.751), BV (p=0.426) and HPI (p=0.437). However, elasticity values were higher, the larger the tumor was (p=0.008). Shear wave velocity declined with increasing distance of the HCC to the skin surface (p=0.028) and depending on liver segment. In addition, elasticity values were higher in less differentiated HCCs. This trend was not statistically significant (p=0.842). CONCLUSION: Tissue elasticity in HCC does not correlate with the degree of tumor vascularization, but calculated values are influenced both by the tumor size and localization inside the liver.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Volume Sanguíneo , Tomografia Computadorizada de Feixe Cônico/métodos , Elasticidade/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Neovascularização Patológica/diagnóstico por imagem , Ultrassonografia
17.
Eur Radiol ; 27(3): 985-994, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27271925

RESUMO

OBJECTIVE: To evaluate feasibility of a 3D-isotropic self-gated radial volumetric interpolated breath-hold examination (VIBE) for late-phase MRI of the liver. MATERIAL AND METHODS: 70 patients were included and underwent liver MRI at 1.5 T. Depending on the diagnosis, either Gd-EOB-DTPA (35 patients) or gadobutrol (35 patients) were administered. During late (gadobutrol) or hepatocyte-specific phase (Gd-EOB-DTPA), a radial prototype sequence was acquired and reconstructed using (1) self-gating with 40 % acceptance (rVIBE40); (2) with 100 % acceptance of the data (rVIBE100) and compared to Cartesian VIBE (cVIBE). Images were assessed qualitatively (image quality, lesion conspicuity, artefacts; 5-point Likert-scale: 5 = excellent; two independent readers) and quantitatively (coefficient-of-variation (CV); contrast-ratio) in axial and coronal reformations. RESULTS: In eight cases only rVIBE provided diagnostic image quality. Image quality of rVIBE40 was rated significantly superior (p < 0.05) in Gd-EOB-DTPA-enhanced and coronal reformatted examinations as compared to cVIBE. Lesion conspicuity was significantly improved (p < 0.05) in coronal reformatted Gd-EOB-DTPA-enhanced rVIBE40 in comparison to cVIBE. CV was higher in rVIBE40 as compared to rVIBE100/cVIBE (p < 0.01). Gadobutrol-enhanced rVIBE40 and cVIBE showed higher contrast-ratios than rVIBE100 (p < 0.001), whereas no differences were found in Gd-EOB-DTPA-enhanced examinations. CONCLUSION: Self-gated 3D-isotropic rVIBE provides significantly superior image quality compared to cVIBE, especially in multiplanar reformatted and Gd-EOB-DTPA-enhanced examinations. KEY POINTS: • Radial VIBE acquisition reduces motion artefacts. • Gd-EOB-DTPA-enhanced scans provide improved image quality. • Non-diagnostic liver MRI examinations may be reduced by radial k-spaces sampling.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Hepatopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Suspensão da Respiração , Meios de Contraste , Estudos de Viabilidade , Feminino , Gadolínio DTPA , Hepatócitos/patologia , Humanos , Aumento da Imagem/métodos , Fígado/diagnóstico por imagem , Fígado/patologia , Hepatopatias/patologia , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos
18.
Rev Esp Cardiol (Engl Ed) ; 69(5): 509-14, 2016 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-27025303

RESUMO

In recent years, coronary computed tomography angiography has become an increasingly safe and noninvasive modality for the evaluation of the anatomical structure of the coronary artery tree with diagnostic benefits especially in patients with a low-to-intermediate pretest probability of disease. Currently, increasing evidence from large randomized diagnostic trials is accumulating on the diagnostic impact of computed tomography angiography for the management of patients with acute and stable chest pain syndrome. At the same time, technical advances have substantially reduced adverse effects and limiting factors, such as radiation exposure, the amount of iodinated contrast agent, and scanning time, rendering the technique appropriate for broader clinical applications. In this work, we review the latest developments in computed tomography technology and describe the scientific evidence on the use of cardiac computed tomography angiography to evaluate patients with acute and stable chest pain syndrome.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Doenças Cardiovasculares/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Doenças Cardiovasculares/complicações , Dor no Peito/diagnóstico por imagem , Dor no Peito/etiologia , Meios de Contraste , Humanos , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X
19.
J Magn Reson Imaging ; 44(1): 186-93, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26717865

RESUMO

PURPOSE: To introduce a dual-contrast fast spin-echo (dcFSE) sequence for signal decay mapping of myocardial edema. MATERIALS AND METHODS: After consultation with the Institutional Review Board, 22 acute myocardial infarction (MI) patients were examined with magnetic resonance imaging (MRI) at 1.5T 2 days after revascularization. Edema was evaluated in 16 myocardial segments with an exponential fit for signal decay time (SDT) in dcFSE mapping and T2 signal intensity ratio for single-contrast FSE. Myocardial viability was evaluated in late gadolinium enhancement (LGE). A control group of 10 volunteers was examined for edema imaging. SDT was compared in segment groups: 1) with LGE in MI, 2) penumbra, 3) remote from LGE, 4) controls. Groups 1/3 and 3/4 were tested on difference. Three phantoms providing similar T2 but different T1 relaxation times (low, intermediate, high) were examined with dcFSE and multicontrast spin echo sequence as a reference. RESULTS: The SDT/T2 ratio for segment groups was 1) 82msec/1.7 in segments with LGE; 2) 65msec/1.6 for penumbra, 3) 62msec/1.7 for remote segments, and 4) 50msec/1.6 in controls. In dcFSE group 1/3 (P < 0.0001) and in group 3/4 (P = 0.0002) SDT was significantly different. In single-contrast FSE the T2 ratio was not significantly different for both tests: 1/3 P = 0.1889; 3/4 P = 0.8879. T2 -overestimation of dcFSE was 23% in low, 29% in intermediate, and 35% in highly T1 contaminated phantoms. CONCLUSION: dcFSE signal decay edema mapping is feasible in volunteers and patients. DcFSE SDT is superior to T2 ratio for detection of high-grade and diffuse myocardial edema. J. Magn. Reson. Imaging 2016;44:186-193.


Assuntos
Algoritmos , Técnicas de Imagem Cardíaca/métodos , Edema Cardíaco/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA