Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Comput Methods Appl Mech Eng ; 361: 112762, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32565583

RESUMO

The human heart beats as a result of multiscale nonlinear dynamics coupling subcellular to whole organ processes, achieving electrophysiologically-driven mechanical contraction. Computational cardiac modelling and simulation have achieved a great degree of maturity, both in terms of mathematical models of underlying biophysical processes and the development of simulation software. In this study, we present the detailed description of a human-based physiologically-based, and fully-coupled ventricular electromechanical modelling and simulation framework, and a sensitivity analysis focused on its mechanical properties. The biophysical detail of the model, from ionic to whole-organ, is crucial to enable future simulations of disease and drug action. Key novelties include the coupling of state-of-the-art human-based electrophysiology membrane kinetics, excitation-contraction and active contraction models, and the incorporation of a pre-stress model to allow for pre-stressing and pre-loading the ventricles in a dynamical regime. Through high performance computing simulations, we demonstrate that 50% to 200% - 1000% variations in key parameters result in changes in clinically-relevant mechanical biomarkers ranging from diseased to healthy values in clinical studies. Furthermore mechanical biomarkers are primarily affected by only one or two parameters. Specifically, ejection fraction is dominated by the scaling parameter of the active tension model and its scaling parameter in the normal direction ( k ort 2 ); the end systolic pressure is dominated by the pressure at which the ejection phase is triggered ( P ej ) and the compliance of the Windkessel fluid model ( C ); and the longitudinal fractional shortening is dominated by the fibre angle ( ϕ ) and k ort 2 . The wall thickening does not seem to be clearly dominated by any of the considered input parameters. In summary, this study presents in detail the description and implementation of a human-based coupled electromechanical modelling and simulation framework, and a high performance computing study on the sensitivity of mechanical biomarkers to key model parameters. The tools and knowledge generated enable future investigations into disease and drug action on human ventricles.

2.
J Sci Comput ; 78(1): 64-93, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30872895

RESUMO

We introduce a discontinuous finite volume method for the approximation of distributed optimal control problems governed by the Brinkman equations, where a force field is sought such that it produces a desired velocity profile. The discretisation of state and co-state variables follows a lowest-order scheme, whereas three different approaches are used for the control representation: a variational discretisation, and approximation through piecewise constant and piecewise linear elements. We employ the optimise-then-discretise approach, resulting in a non-symmetric discrete formulation. A priori error estimates for velocity, pressure, and control in natural norms are derived, and a set of numerical examples is presented to illustrate the performance of the method and to confirm the predicted accuracy of the generated approximations under various scenarios.

3.
Chaos ; 27(9): 093919, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28964112

RESUMO

This work reports the results of the theoretical investigation of nonlinear dynamics and spiral wave breakup in a generalized two-variable model of cardiac action potential accounting for thermo-electric coupling and diffusion nonlinearities. As customary in excitable media, the common Q10 and Moore factors are used to describe thermo-electric feedback in a 10° range. Motivated by the porous nature of the cardiac tissue, in this study we also propose a nonlinear Fickian flux formulated by Taylor expanding the voltage dependent diffusion coefficient up to quadratic terms. A fine tuning of the diffusive parameters is performed a priori to match the conduction velocity of the equivalent cable model. The resulting combined effects are then studied by numerically simulating different stimulation protocols on a one-dimensional cable. Model features are compared in terms of action potential morphology, restitution curves, frequency spectra, and spatio-temporal phase differences. Two-dimensional long-run simulations are finally performed to characterize spiral breakup during sustained fibrillation at different thermal states. Temperature and nonlinear diffusion effects are found to impact the repolarization phase of the action potential wave with non-monotone patterns and to increase the propensity of arrhythmogenesis.


Assuntos
Potenciais de Ação/fisiologia , Eletricidade , Modelos Cardiovasculares , Dinâmica não Linear , Temperatura , Difusão , Análise de Elementos Finitos , Análise Numérica Assistida por Computador
4.
Int J Numer Method Biomed Eng ; 28(1): 52-71, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25830205

RESUMO

We propose a finite element approximation of a system of partial differential equations describing the coupling between the propagation of electrical potential and large deformations of the cardiac tissue. The underlying mathematical model is based on the active strain assumption, in which it is assumed that there is a multiplicative decomposition of the deformation tensor into a passive and active part holds, the latter carrying the information of the electrical potential propagation and anisotropy of the cardiac tissue into the equations of either incompressible or compressible nonlinear elasticity, governing the mechanical response of the biological material. In addition, by changing from a Eulerian to a Lagrangian configuration, the bidomain or monodomain equations modeling the evolution of the electrical propagation exhibit a nonlinear diffusion term. Piecewise quadratic finite elements are employed to approximate the displacements field, whereas for pressure, electrical potentials and ionic variables are approximated by piecewise linear elements. Various numerical tests performed with a parallel finite element code illustrate that the proposed model can capture some important features of the electromechanical coupling and show that our numerical scheme is efficient and accurate.


Assuntos
Coração/fisiologia , Modelos Cardiovasculares , Estresse Mecânico , Anisotropia , Simulação por Computador , Difusão , Elasticidade/fisiologia , Análise de Elementos Finitos , Fenômenos Mecânicos , Pressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA