Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
J Arrhythm ; 40(1): 191-194, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333391

RESUMO

Background: Electroanatomical mapping is an essential tool in the ablation of typical AFL. Objectives: To identify the existence of voltage patterns in the CTI voltage maps and their relevance for typical AFL ablation. Methods: A voltage map of the CTI was made prior to ablation, identifying the areas of maximum voltage and their location along the CTI, allowing classification into patterns according to their distribution. A stepwise ablation approach targeting the areas of maximum voltage was conducted. The ablation characteristics were compared based on the pattern obtained. Results: Two voltage patterns were identified, with differences in ablation time to bidirectional CTI block. No complications occurred. Conclusions: Voltage mapping identifies patterns in the CTI with implications for typical AFL ablation.

2.
Front Cardiovasc Med ; 10: 991307, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36818338

RESUMO

Background: Implantable cardioverter defibrillators (ICD) are effective as a primary prevention measure of ventricular tachyarrhythmias in patients with ST-segment elevation myocardial infarction (STEMI) and depressed left ventricular ejection fraction (LVEF). The implications of using cardiac magnetic resonance (CMR) instead of echocardiography (Echo) to assess LVEF prior to the indication of ICD in this setting are unknown. Materials and methods: We evaluated 52 STEMI patients (56.6 ± 11 years, 88.5% male) treated with ICD in primary prevention who underwent echocardiography and CMR prior to ICD implantation. ICD implantation was indicated based on the presence of heart failure and depressed LVEF (≤ 35%) by echocardiography, CMR, or both. Prediction of ICD therapies (ICD-T) during follow-up by echocardiography and CMR before ICD implantation was assessed. Results: Compared to echocardiography, LVEF was lower by cardiac CMR (30.2 ± 9% vs. 37.4 ± 7.6%, p < 0.001). LVEF ≤ 35% was detected in 24 patients (46.2%) by Echo and in 42 (80.7%) by CMR. During a mean follow-up of 6.1 ± 4.2 years, 10 patients received appropriate ICD-T (3.16 ICD-T per 100 person-years): 5 direct shocks to treat very fast ventricular tachycardia or ventricular fibrillation, 3 effective antitachycardia pacing (ATP) for treatment of ventricular tachycardia, and 2 ineffective ATP followed by shock to treat ventricular tachycardia. Echo-LVEF ≤ 35% correctly predicted ICD-T in 4/10 (40%) patients and CMR-LVEF ≤ 35% in 10/10 (100%) patients. CMR-LVEF improved on Echo-LVEF for predicting ICD-T (area under the curve: 0.76 vs. 0.48, p = 0.04). Conclusion: In STEMI patients treated with ICD, assessment of LVEF by CMR outperforms Echo-LVEF to predict the subsequent use of appropriate ICD therapies.

3.
J Clin Med ; 11(5)2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35268259

RESUMO

Introduction: Cryoballoon ablation (CBA) has become a standard treatment for paroxysmal atrial fibrillation (PaAF) but limited data is available for outcomes in patients with persistent atrial fibrillation (PeAF). Methods: We analyzed the first 944 patients included in the Spanish Prospective Multi-center Observation Post-market Registry to compare characteristics and outcomes of patients undergoing CBA for PeAF versus PaAF. Results: A total of 944 patients (57.8 ± 10.4 years; 70.1% male) with AF (27.9% persistent) were prospectively included from 25 centers. PeAF patients were more likely to have structural heart disease (67.7 vs. 11.4%; p < 0.001) and left atrium dilation (72.6 vs. 43.3%; p < 0.001). CBA of PeAF was less likely to be performed under general anesthesia (10.7 vs. 22.2%; p < 0.001), with an arterial line (32.2 vs. 44.6%; p < 0.001) and assisted transeptal puncture (11.9 vs. 17.9%; p = 0.025). During an application, PeAF patients had a longer time to −30 °C (35.91 ± 14.20 vs. 34.93 ± 12.87 s; p = 0.021) and a colder balloon nadir temperature during vein isolation (−35.04 ± 9.58 vs. −33.61 ± 10.32 °C; p = 0.004), but received fewer bonus freeze applications (30.7 vs. 41.1%; p < 0.001). There were no differences in acute pulmonary vein isolation and procedure-related complications. Overall, 76.7% of patients were free from AF recurrences at 15-month follow-up (78.9% in PaAF vs. 70.9% in PeAF; p = 0.09). Conclusions: Patients with PeAF have a more diseased substrate, and CBA procedures performed in such patients were more simplified, although longer/colder freeze applications were often applied. The acute efficacy/safety profile of CBA was similar between PaAF and PeAF patients, but long-term results were better in PaAF patients.

4.
Sci Rep ; 11(1): 17268, 2021 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-34446764

RESUMO

Cryoablation is safe and effective for the treatment of atrial fibrillation (AF) in controlled clinical trials, but contemporary real-world usage and outcomes are limited. The Report of the Spanish Cryoballoon Ablation Registry (RECABA) was designed to evaluate acute and 12-month outcomes of cryoballoon ablation for the treatment of AF in Spain. Patients from 27 Spanish centers were prospectively enrolled. Patients were treated with cryoballoon ablation and managed according to standard of care protocols at each center. The primary endpoint was ≥ 30 s freedom from AF at 12-month after a 3-month blanking period. Secondary endpoints included a description of patient characteristics, cryoablation procedural strategy and safety, and predictors of efficacy. In total, 1742 patients (71.4% PAF, 68.8% male, mean age 58.02 ± 10.40 years, 76.1% overweight or obese, CHA2DS2-VASc index 1.40 ± 1.28) were enrolled. Patients received 7.2 ± 2.67 cryo-applications. PV potentials could be detected in 61% of the PVs during ablation, with a mean time to block of 52.9 ± 37.02 s. Acute PVI was observed in 97% of PVs with 75.8% isolated with the first cryo-application. Mean procedural time was 113 ± 41 min. Acute complications occurred in 4.4% of the cases. With follow-up in 1628 patients, AF-free survival was 78.5% (PAF: 80.6% vs PersAF 73.3%; p < 0.001). Left atrium enlargement, female sex, non-PAF, and early recurrence were independent predictors of AF recurrence (p < 0.05). RECABA provides detailed insight into current dosing practices and demonstrates cryoablation is safe and effective in real-world use.ClinicalTrials.gov number: NCT02785991.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/métodos , Estudos Prospectivos , Recidiva , Espanha , Fatores de Tempo , Adulto Jovem
5.
Rev Esp Cardiol (Engl Ed) ; 74(4): 296-302, 2021 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32773348

RESUMO

INTRODUCTION AND OBJECTIVES: The ADVANCE III trial showed that a delayed-detection strategy reduces implantable cardioverter-defibrillator (ICD) therapies. Here, we describe the adherence to and predictors of ADVANCE adoption and compare ICD therapy rates between patients with and without ADVANCE programming. METHODS: This observational retrospective study analyzed patients implanted with Medtronic ICDs included from 2005 to 2016 in a Spanish national multicenter registry (UMBRELLA database; ClinicalTrials.gov, NCT01561144). Changes in ADVANCE programming adoption were described in relation to a) publication of the ADVANCE trial, b) implementation of an "ADVANCE awareness" campaign, and c) publication of an expert consensus statement. Multivariate logistic regression identified predictors of adoption. Therapy incidence rates were compared between groups by estimating the adjusted incidence rate ratio (aIRR) using negative binomial regression. RESULTS: A total of 3528 patients were included. An ADVANCE strategy was used in 20% overall and in 44% at the end of the study. ADVANCE III adoption increased after trial publication, with less growth after an "ADVANCE awareness" campaign and after expert consensus statement publication. Predictors of ADVANCE adoption were as follows: ICD device with a nominal number of intervals to detect 30/40 (aOR, 4.4; 95%CI, 3.5-5.4), implantation by an electrophysiologist (aOR, 1.7; 95%CI, 1.4-2.2), and secondary prevention (aOR, 3.2; 95%CI, 2.6-3.9). Dual-chamber ICDs (aOR, 0.6; 95%CI, 0.5-0.8) and cardiac resynchronization-defibrillators (aOR, 0.5; 95%CI, 0.4-0.7) were associated with lower adoption. ADVANCE programming was associated with reduced total therapy burden (aIRR, 0.77; 95%CI, 0.69-0.86) and fewer inappropriate shocks (aIRR, 0.66; 95%CI, 0.52-0.85). CONCLUSIONS: ADVANCE adoption remains modest and can be improved through evidence-driven selection of nominal ICD settings. ADVANCE programming is associated with reduced therapy rates in real-world ICD recipients.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Cardioversão Elétrica , Humanos , Incidência , Estudos Retrospectivos
6.
Rev Esp Cardiol (Engl Ed) ; 73(10): 847, 2020 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32980119
8.
Sensors (Basel) ; 20(15)2020 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-32726931

RESUMO

Ventricular fibrillation (VF) signals are characterized by highly volatile and erratic electrical impulses, the analysis of which is difficult given the complex behavior of the heart rhythms in the left (LV) and right ventricles (RV), as sometimes shown in intracardiac recorded Electrograms (EGM). However, there are few studies that analyze VF in humans according to the simultaneous behavior of heart signals in the two ventricles. The objective of this work was to perform a spectral and a non-linear analysis of the recordings of 22 patients with Congestive Heart Failure (CHF) and clinical indication for a cardiac resynchronization device, simultaneously obtained in LV and RV during induced VF in patients with a Biventricular Implantable Cardioverter Defibrillator (BICD) Contak Renewal IVTM (Boston Sci.). The Fourier Transform was used to identify the spectral content of the first six seconds of signals recorded in the RV and LV simultaneously. In addition, measurements that were based on Information Theory were scrutinized, including Entropy and Mutual Information. The results showed that in most patients the spectral envelopes of the EGM sources of RV and LV were complex, different, and with several frequency peaks. In addition, the Dominant Frequency (DF) in the LV was higher than in the RV, while the Organization Index (OI) had the opposite trend. The entropy measurements were more regular in the RV than in the LV, thus supporting the spectral findings. We can conclude that basic stochastic processing techniques should be scrutinized with caution and from basic to elaborated techniques, but they can provide us with useful information on the biosignals from both ventricles during VF.


Assuntos
Fibrilação Ventricular , Arritmias Cardíacas , Desfibriladores Implantáveis , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Insuficiência Cardíaca , Ventrículos do Coração , Humanos , Fibrilação Ventricular/diagnóstico
9.
Rev Esp Cardiol (Engl Ed) ; 73(8): 664, 2020 Aug.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32711841
10.
Rev Esp Cardiol (Engl Ed) ; 73(7): 580, 2020 Jul.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32605844
11.
J Arrhythm ; 36(3): 542-543, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32528587

RESUMO

Electrocardiogram showing a regular wide QRS tachycardia with left branch block (LBBB) like in morphology at 200 beats per minute (bpm). During electrophysiology study, it suddenly gets narrow and faster. What is the mechanism of the switch from a broad complex to a narrow complex tachycardia?

12.
Rev Esp Cardiol (Engl Ed) ; 73(11): 952, 2020 11.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-34756206
13.
Europace ; 22(2): 314-319, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31713631

RESUMO

AIMS: Reflex vasovagal syncope (VVS) is the most common cause of syncope and patients with recurrent episodes may severely impair quality of life (QoL). This pre-specified analysis evaluated whether the clinically significant reduction in syncope burden demonstrated by dual-chamber pacing with closed loop stimulation (DDD-CLS) reported in the SPAIN trial translates into improved QoL. METHODS AND RESULTS: Patients aged ≥40 years with ≥5 VVS episodes and cardioinhibitory response induced by head-up tilt testing were included. Patients were randomized 1:1 to active DDD-CLS pacing algorithm for 12 months followed by sham DDI mode for the remaining 12 months (Group A) or vice versa (Group B). QoL was assessed using the Short Form-36 (SF-36) health survey, Physical Component Score (PCS), and Mental Component Score (MCS) before randomization (baseline) and at 12- and 24-month follow-up. Fifty-four patients were enrolled from 11 participating centres. No significant carryover effect was detected for any variable, and the only period effect was observed in the vitality subdomain (P = 0.033). Mean SF-36 scores were higher in the DDD-CLS group vs. the DDI group for the eight subdomains and significantly different in physical role, bodily pain, and vitality (P < 0.05). The analysis of component summary scores indicated that DDD-CLS benefited both mental and physical components with significant differences in PCS when compared with the DDI group. CONCLUSION: Dual-chamber pacing with closed loop stimulation determined a significant and clinically relevant improvement in QoL across both mental and physical components in patients with recurrent VVS. REGISTRATION: Closed Loop Stimulation for Neuromediated Syncope (SPAIN Study); NCT01621464.


Assuntos
Qualidade de Vida , Síncope Vasovagal , Estimulação Cardíaca Artificial , Humanos , Recidiva , Reflexo , Espanha , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/terapia
15.
J Cardiovasc Electrophysiol ; 30(9): 1483-1490, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31115940

RESUMO

INTRODUCTION: Recurrences after atrial fibrillation (AF) ablation are still common. Among the reported clinical and imaging predictors of recurrences, diagnosis-to-ablation time (DAT) has been defined as a predictor of ablation outcome in single-center studies. We aimed to validate DAT in a multicenter real-life cohort. METHODS: This was a multicenter study including consecutive patients undergoing first paroxysmal and persistent AF ablation with radiofrequency or cryoballoon catheters during 2013. Cox proportional hazard regression models were performed to identify predictors of recurrence. RESULTS: In total, 309 patients were included across nine centers (71% men, 57 ± 10 years old, 46% with hypertension, and 66% with CHA2 DS2 -VASc ≤ 1). Most patients had paroxysmal AF (67%) and underwent radiofrequency ablation (68%) with a median DAT of 51 (43) months. Patients with DAT ≤ 1 year (16.6%) were less likely to have repeat procedures (4% vs 18%; P = .017). The adjusted proportional hazards Cox model identified hypertension (P = .005), heart failure (P = .011), nonparoxysmal AF (P = .038), DAT > 1 year (P = .007), and LA diameter (P = .026) as independent predictors for AF recurrence. DAT > 1 year was the only modifiable factor independently associated with recurrence (HR 4.2 [95% CI, 1.5-11.9]) CONCLUSION: Diagnosis-to-ablation time is a modifiable factor independently associated with recurrent arrhythmia and repeat ablation after first AF ablation. An early intervention strategy during the first year from AF diagnosis might improve outcomes.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Veias Pulmonares/cirurgia , Tempo para o Tratamento , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Medição de Risco , Fatores de Risco , Espanha , Fatores de Tempo , Resultado do Tratamento
16.
Heart Rhythm ; 16(9): 1429-1435, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30910709

RESUMO

BACKGROUND: Inappropriate shocks (IS) continue to have a major negative impact on patients implanted with defibrillators. OBJECTIVE: The purpose of this study was to assess IS reduction with the PARAD+ discrimination algorithm in a general population implanted for primary or secondary prevention. METHODS: ISIS-ICD (Inappropriate Shock Reduction wIth PARAD+ Rhythm DiScrimination-Implantable Cardioverter Defibrillator) was a 2-year international, interventional study in patients implanted with a dual implantable cardioverter-defibrillator (ICD) or triple-chamber defibrillator (cardiac resynchronization therapy-defibrillator [CRT-D]) featuring PARAD+. IS (shocks not delivered for ventricular tachycardia or fibrillation) were independently adjudicated. The primary endpoint was percentage of IS-free patients at 24 months. Primary and worst-case analyses of annual incidence rates of patients with ≥1 IS, overall and per defibrillator type, were conducted. RESULTS: In total, 1013 patients (80.7% male; age 67.1 ± 11.4 years; 68%/30%/2% primary/secondary/other indication) were enrolled and followed for a median of 552 days (interquartile range 354; 725). Of 993 analyzed patients programmed with PARAD+, 14 had ≥1 IS, corresponding to a percentage free from IS of 98.1% (95% confidence interval [CI] 96.8%- 98.9%). Annual incidence rates (per 100 person-years) of patients with IS were 1.0 (95% CI 0.59-1.69) and 2.1 (95% CI 1.46-3.02) in the primary and worst-case analyses, respectively. In ICD patients, rates were 1.2 (95% CI 0.68-2.23) and 2.3 (95% CI 1.47-3.53), and in CRT-D patients 0.59 (95% CI 0.19-1.83) and 1.8 (95% CI 0.93-3.44) per 100 person-years. CONCLUSION: The annual rate of defibrillator patients with IS using the enhanced PARAD+ discrimination algorithm alone ranged from 1.0 to 2.1 per 100 person-years in a general population implanted for primary or secondary prevention.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica , Falha de Equipamento/estatística & dados numéricos , Taquicardia Ventricular/terapia , Fibrilação Ventricular/prevenção & controle , Algoritmos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Segurança de Equipamentos/métodos , Segurança de Equipamentos/estatística & dados numéricos , Feminino , Análise do Modo e do Efeito de Falhas na Assistência à Saúde/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde
17.
Eur Geriatr Med ; 10(1): 129-133, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-32720280

RESUMO

BACKGROUND/OBJECTIVES: Syncope in octogenarians represents an important problem in terms of comorbidity, quality of life and substantial medical costs, resulting from studies and treatments. An implantable loop ecorder (ILR) may improve diagnostic performance. The objective of the study was to evaluate the results of the ILR in a population of octogenarians. DESIGN: Prospective registry of patients receiving an implantable loop recorder in 40 Spanish centers. PARTICIPANTS: 128 octogenarians implanted with a device for clinical evaluation of syncope. METHODS: Prospective registry recording the incidence of new symptoms or device activations within the first year after the implant, the incidence of new diagnosis and treatments, and an evaluation of the safety of this strategy in this population. Dedicated database for the registry. RESULTS: Forty-two patients (33% of the population) obtained a final etiological diagnosis of the syncope, which led to a specific treatment in 39 (31%) patients. No differences regarding the presence of conduction disturbances or structural heart disease were found in this population. A mortality of 4% was recorded during follow-up. CONCLUSION: The implantable loop recorder seems to be an effective and safe tool in the management of syncope in the octogenarian population.

19.
Europace ; 21(2): 250-258, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30321320

RESUMO

AIMS: Atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) is usually associated to conduction gaps in pulmonary veins (PVs). Our objective was to characterize gaps in patients with recurrences after a first radiofrequency (RF) or cryoballoon (CB) PVI procedure, using a high-density mapping (HDM) system. METHODS AND RESULTS: Fifty patients with AF recurrence after a first PVI procedure (pre-RF 25 patients; pre-CB 25 patients) were included at two centres. Activation map (AM) and voltage map (VM) of the left atrium and PVs were built using the HDM Rhythmia® system. Superior PVs were reconnected more frequently in both groups. Right PVs were reconnected more frequently in pre-RF patients. Pre-RF patients had more reconnected veins than pre-CB patients (mean ± standard deviation: 3.00 ± 0.96 vs. 1.88 ± 1.13; P < 0.001) and more gaps (4.84 ± 2.06 vs. 2.16 ± 1.49; P < 0.001). Gaps in the VM were wider in pre-CB patients (16.5 ± 9.5 mm vs. 12.1 ± 4.8 mm; P = 0.006). There was a gap in 179 of the 800 PV segments analysed (22%); 52% were identified in both AM and VM maps; 39% only in the AM and 8% only in the VM. The highest sensitivity and specificity for gap detection was obtained with VM in pre-CB patients and with AM in pre-RF patients. CONCLUSION: In conclusion, HDM seems to be a useful and precise tool to detect conduction gaps after a first PVI procedure. The anatomical pattern and location of gaps depends on the technique used previously, usually being multiple, smaller, and better detected by AM after RF, and fewer, wider, and better detected by VM after CB.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Cicatriz/etiologia , Criocirurgia/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cicatriz/diagnóstico , Cicatriz/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Risco , Espanha , Fatores de Tempo , Resultado do Tratamento
20.
Eur Heart J Cardiovasc Imaging ; 19(9): 1002-1009, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29659784

RESUMO

Aims: Left atrial (LA) remodelling is a key determinant of atrial fibrillation (AF) ablation outcome. Optimal methods to assess this process are scarce. LA sphericity is a shape-based parameter shown to be independently associated to procedural success. In a multicentre study, we aimed to test the feasibility of assessing LA sphericity and evaluate its capability to predict procedural outcomes. Methods and results: This study included consecutive patients undergoing first AF ablation during 2013. A 3D model of the LA chamber, excluding pulmonary veins and LA appendage, was used to quantify LA volume (LAV) and LA sphericity (≥82.1% was considered spherical LA). In total, 243 patients were included across 9 centres (71% men, aged 56 ± 10 years, 44% with hypertension and 76% CHA2DS2-VASc ≤ 1). Most patients had paroxysmal AF (66%) and underwent radiofrequency ablation (60%). Mean LA diameter (LAD), LAV, and LA sphericity were 42 ± 6 mm, 100 ± 33 mL, and 82.6 ± 3.5%, respectively. Adjusted Cox models identified paroxysmal AF [hazard ratio (HR 0.54, P = 0.032)] and LA sphericity (HR 1.87, P = 0.035) as independent predictors for AF recurrence. A combined clinical-imaging score [Left Atrial Geometry and Outcome (LAGO)] including five items (AF phenotype, structural heart disease, CHA2DS2-VASc ≤ 1, LAD, and LA sphericity) classified patients at low (≤2 points) and high risk (≥3 points) of procedural failure (35% vs. 82% recurrence at 3-year follow-up, respectively; HR 3.10, P < 0.001). Conclusion: In this multicentre, real-life cohort, LA sphericity and AF phenotype were the strongest predictors of AF ablation outcome after adjustment for covariates. The LAGO score was easy to implement, identified high risk of procedural failure, and could help select optimal candidates. Clinical Trial Registration Information: NCT02373982 (http://clinicaltrials.gov/ct2/show/NCT02373982).


Assuntos
Fibrilação Atrial/cirurgia , Remodelamento Atrial/fisiologia , Ablação por Cateter/métodos , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Fatores Etários , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Cuidados Pós-Operatórios , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Recidiva , Medição de Risco , Fatores Sexuais , Análise de Sobrevida , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA