Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
3.
Endoscopy ; 54(1): 16-24, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33395714

RESUMO

BACKGROUND: Endoscopic resection of lesions involving the appendiceal orifice remains a challenge. We aimed to report outcomes with the full-thickness resection device (FTRD) for the resection of appendiceal lesions and identify factors associated with the occurrence of appendicitis. METHODS: This was a retrospective study at 18 tertiary-care centers (USA 12, Canada 1, Europe 5) between November 2016 and August 2020. Consecutive patients who underwent resection of an appendiceal orifice lesion using the FTRD were included. The primary outcome was the rate of R0 resection in neoplastic lesions, defined as negative lateral and deep margins on post-resection histologic evaluation. Secondary outcomes included the rates of: technical success (en bloc resection), clinical success (technical success without need for further surgical intervention), post-resection appendicitis, and polyp recurrence. RESULTS: 66 patients (32 women; mean age 64) underwent resection of colonic lesions involving the appendiceal orifice (mean [standard deviation] size, 14.5 (6.2) mm), with 40 (61 %) being deep, extending into the appendiceal lumen. Technical success was achieved in 59/66 patients (89 %), of which, 56 were found to be neoplastic lesions on post-resection pathology. Clinical success was achieved in 53/66 (80 %). R0 resection was achieved in 52/56 (93 %). Of the 58 patients in whom EFTR was completed who had no prior history of appendectomy, appendicitis was reported in 10 (17 %), with six (60 %) requiring surgical appendectomy. Follow-up colonoscopy was completed in 41 patients, with evidence of recurrence in five (12 %). CONCLUSIONS: The FTRD is a promising non-surgical alternative for resecting appendiceal lesions, but appendicitis occurs in 1/6 cases.


Assuntos
Apêndice , Ressecção Endoscópica de Mucosa , Colonoscopia , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
5.
Gastrointest Endosc ; 94(4): 727-732, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33957105

RESUMO

BACKGROUND AND AIMS: EUS-directed transgastric ERCP (the EDGE procedure) is a simplified method of performing ERCP in Roux-en-Y gastric bypass patients. The EDGE procedure involves placement of a lumen-apposing metal stent (LAMS) into the excluded stomach to serve as a conduit for passage of the duodenoscope for pancreatobiliary intervention. Originally a multistep process, urgent indications for ERCP have led to the development of single-session EDGE (SS-EDGE) with LAMS placement and ERCP performed in the same session. The goal of this study was to identify predictive factors of intraprocedural LAMS migration in SS-EDGE. METHODS: We conducted a multicenter retrospective review that included 9 tertiary medical centers across the United States. Data were collected and analyzed from 128 SS-EDGE procedures. The primary outcome was intraprocedural LAMS migration. Secondary outcomes were other procedural adverse events such as bleeding and perforation. RESULTS: Eleven LAMS migrations were observed in 128 procedures (8.6%). Univariate analysis of clinically relevant variables was performed, as was a binary logistic regression analysis of stent diameter and stent dilation. This revealed that use of a smaller (15 mm) diameter LAMS was an independent predictor of intraprocedural stent migration (odds ratio, 5.36; 95% confidence interval, 1.29-22.24; P = .021). Adverse events included 3 patients who required surgery and 2 who experienced intraprocedural bleeding. CONCLUSIONS: Use of a larger-diameter LAMS is a predictive factor for a nonmigrated stent and improved procedural success in SS-EDGE. Although larger patient cohorts are needed to adequately assess these findings, performance of LAMS dilation and fixation may also decrease risk of intraprocedural LAMS migration and improve procedural success.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Derivação Gástrica , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Derivação Gástrica/efeitos adversos , Humanos , Estudos Retrospectivos , Stents , Estômago/cirurgia
6.
VideoGIE ; 6(5): 215-218, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34027251

RESUMO

Video 1Percutaneous transcystic cholangioscopy-assisted rendezvous ERCP in a hostile abdomen.

7.
Endosc Int Open ; 9(2): E116-E121, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33532547

RESUMO

Background and study aims The use of fluoroscopy during pregnancy should be minimized given that a clear-cut safe radiation dose in pregnancy is unknown. The role of digital single-operator cholangioscopy (D-SOC) as an alternative to standard enodoscopic retrograde cholangiopancreatography (ERCP) in pregnant patients has not been comprehensively studied. This study assessed 1 Technical success defined as performance of ERCP with D-SOC without the use of fluoroscopy in pregnant patients; 2 safety of D-SOC in pregnancy; and 3 maternal and neonatal outcomes after D-SOC during/after pregnancy. Patients and methods This was an international, multicenter, retrospective study at 6 tertiary centers. Pregnant patients who underwent D-SOC for the treatment of bile duct stones and/or strictures were included. Results A total of 10 patients underwent D-SOC. Indications for ERCP were choledocholithiasis, strictures, previous stent removal, and choledocholithiasis/stent removal. Bile duct cannulation without fluoroscopy was achieved in 10 of 10 patients (100 %). Moreover, 50 % of patients (5/10) completed a fluoroless ERCP with D-SOC. Mean fluoroscopy dose and fluoroscopy time were 3.4 ±â€Š7.2 mGy and 0.5 ±â€Š0.8 min, respectively. One case of mild bleeding and one case of moderate post-ERCP pancreatitis occurred. The mean gestational age at delivery was 36.2 ±â€Š2.6 weeks. Median birth weight was 2.5 kg [IQR: 2.2-2.8]. No birth defects were noted. Conclusion ERCP guided by D-SOC appears to be a feasible and effective alternative to standard ERCP in pregnant patients. It enables avoidance of radiation in half of cases.

8.
Endoscopy ; 53(6): 611-618, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32882722

RESUMO

BACKGROUND: Endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (ERCP; EDGE) is an alternative to enteroscopy- and laparoscopy-assisted ERCP in patients with Roux-en-Y gastric bypass anatomy. Although short-term results are promising, the long-term outcomes are not known. The aims of this study were: (1) to determine the rates of long-term adverse events after EDGE, with a focus on rates of persistent gastrogastric or jejunogastric fistula; (2) to identify predictors of persistent fistula; (3) to assess the outcomes of endoscopic closure when persistent fistula is encountered. METHODS: This was a multicenter retrospective study involving 13 centers between February 2015 and March 2019. Adverse events were defined according to the ASGE lexicon. Persistent fistula was defined as an upper gastrointestinal series or esophagogastroduodenoscopy showing evidence of fistula. RESULTS: 178 patients (mean age 58 years, 79 % women) underwent EDGE. Technical success was achieved in 98 % of cases (175/178), with a mean procedure time of 92 minutes. Periprocedural adverse events occurred in 28 patients (15.7 %; mild 10.1 %, moderate 3.4 %, severe 2.2 %). The four severe adverse events were managed laparoscopically. Persistent fistula was diagnosed in 10 % of those sent for objective testing (9/90). Following identification of a fistula, 5 /9 patients underwent endoscopic closure procedures, which were successful in all cases. CONCLUSIONS: The EDGE procedure is associated with high clinical success rates and an acceptable risk profile. Persistent fistulas after lumen-apposing stent removal are uncommon, but objective testing is recommended to identify their presence. When persistent fistulas are identified, endoscopic treatment is warranted, and should be successful in closing the fistula.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Derivação Gástrica , Endoscopia Gastrointestinal , Endossonografia , Feminino , Derivação Gástrica/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
ACG Case Rep J ; 7(7): e00419, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32766361

RESUMO

Heterotopic pancreas is pancreatic tissue present outside of the normal location of the pancreas. In the presence of cystic degeneration, heterotopic pancreas is clinically significant because of the symptoms it causes and its physical resemblance to cancerous growth. A diagnosis of heterotopic pancreas is achieved with the aid of various endoscopic techniques for tissue removal. Submucosal tunneling endoscopic resection has proven successful for the resection of gastric subepithelial masses. We present a 53-year-old woman undergoing submucosal tunneling endoscopic resection for the resection of a subepithelial gastric cyst caused by heterotopic pancreas with cystic degeneration.

14.
VideoGIE ; 5(6): 260-263, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32529164

RESUMO

BACKGROUND AND AIMS: Accessing the pancreatobiliary region in patients with a history of Roux-en-Y gastric bypass (RYGB) can be challenging. Traditionally, techniques such as percutaneous biliary drainage, enteroscopy-assisted ERCP, and laparoscopy-assisted ERCP have been used. However, each technique has its limitations. EUS-directed transgastric ERCP (EDGE) using a lumen-apposing metal stent (LAMS) has emerged as a novel endoscopic technique for ERCP in patients who have undergone RYGB. The aim of this case series was to highlight LAMS-related shortcomings and adverse events during the periprocedural period. METHODS: This was a retrospective review of 4 patients with RYGB anatomy who underwent EDGE for the management of pancreaticobiliary disease and experienced LAMS-related adverse events. Techniques for managing and avoiding these events are discussed. RESULTS: Four patients underwent EDGE with both technical and clinical success. Slight LAMS migration with partial mucosal overgrowth was encountered in 1 case and was managed by LAMS removal. A large, bleeding, distal marginal ulcer after the EDGE procedure was encountered in the second case and was managed with proton pump inhibitor and removal of the LAMS, with fistula treatment with argon plasma coagulation used to enhance closure. The third case was complicated by moderate intraprocedural bleeding after LAMS dilation, which was managed by applying balloon tamponade and placing a through-the-scope esophageal stent across the LAMS. Last, preferential food passage to the excluded stomach was noted in the fourth case and resulted in symptomatic distention. The symptomatic distention was managed by another de novo jejunogastrostomy using a LAMS for drainage. CONCLUSIONS: Despite its feasibility and acceptable safety profile, the use of LAMSs during EDGE could be associated with several procedure-specific adverse events, which can be avoided or managed endoscopically with no further consequence.

20.
Obes Surg ; 30(5): 2056-2060, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31858398

RESUMO

INTRODUCTION AND AIM: Endoscopic sleeve gastroplasty (ESG) is a procedure in which endoscopically placed sutures involute the stomach and promote weight loss. There is limited data on the durability of these sutures. PATIENTS AND METHODS: This was a single center series of 5 patients who underwent ESG performed by a single endoscopist. Patients underwent repeat endoscopy for different clinical indications. RESULTS: ESGs were successfully reversed at 3 weeks and 1 month following index ESG without significant fibrosis or scaring. At 8 and 14 months, a few sutures had dehisced though there were extensive areas of fibrosis. By 2 years, most of the sutures had dehisced; however, the gastric volume remained reduced. CONCLUSION: This case series offers an intriguing evaluation of the anatomical changes induced by ESG.


Assuntos
Gastroplastia , Obesidade Mórbida , Endoscopia , Gastroplastia/efeitos adversos , Humanos , Obesidade/cirurgia , Obesidade Mórbida/cirurgia , Estômago/cirurgia , Suturas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA