Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Pediatr Orthop ; 44(7): e588-e591, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38869022

RESUMO

BACKGROUND: Fractures of the distal tibial epiphysis in children are often accompanied by articular surface disruption. With increased displacement, internal fixation is frequently performed with an epiphyseal screw to close the fracture gap. Despite limited, high-level clinical evidence to support implant removal, epiphyseal screws are commonly removed after fracture healing due to potentially increased contact forces on the tibiotalar joint. The purpose of this study was to investigate and compare outcomes and complications in children that underwent surgical treatment of distal tibial epiphyseal fractures with placement of an epiphyseal screw(s) and had the implant(s) retained versus removed at a minimum of 2-year postoperative follow-up. METHODS: Children younger than 18 years from two urban tertiary care centers who underwent operative management of distal tibia Salter-Harris III and IV fractures using epiphyseal screws (2013-2020) were divided into two cohorts: retained epiphyseal screws and implant removed. Demographics, intraoperative, postoperative, and radiographic data were collected. Patient-reported outcomes (PROs) using the Foot and Ankle Ability Measure (FAAM) and Single Assessment Numeric Evaluation (SANE) questionnaires were collected at the final follow-up. Statistical analysis, including power analysis, was performed. RESULTS: Fifty-two children were included (30 males, 22 females) with a mean age of 13.3 years at the time of injury (range, 7.7-16.4 years). Thirty-five children retained the implants; seventeen had implants removed. All completed the FAAM questionnaires at a mean follow-up of 4.4 ± 1.9 years, while 29 completed the SANE questionnaire at a mean follow-up of 4.4 ± 1.7 years. No statistically significant difference in patient demographics, surgical variables, or PROs was observed. Six children experienced complications from the initial surgery, including infections and complex regional pain syndrome, with no difference in complication rates between the cohorts ( P =0.08). Furthermore, no complication was observed as a result of implant removal. CONCLUSIONS: Children with retained epiphyseal implants have similar functional outcomes as compared with those who had implants removed after distal tibial epiphyseal fracture fixation and union. LEVEL OF EVIDENCE: Level III-Retrospective comparative study.


Assuntos
Parafusos Ósseos , Remoção de Dispositivo , Epífises , Fixação Interna de Fraturas , Fraturas da Tíbia , Humanos , Feminino , Masculino , Criança , Fraturas da Tíbia/cirurgia , Adolescente , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/efeitos adversos , Epífises/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Consolidação da Fratura , Seguimentos , Medidas de Resultados Relatados pelo Paciente , Complicações Pós-Operatórias/etiologia
2.
Am J Sports Med ; 52(6): 1498-1504, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38619042

RESUMO

BACKGROUND: Recent adult studies have demonstrated that decreased posterior tibial slope angle (PTSA) may be a risk factor for posterior cruciate ligament (PCL) injury. However, there is no study investigating this phenomenon in a pediatric population. Understanding risk factors for PCL injuries among a pediatric population is important given the recent rise in athletic competition/specialization and sports-related injuries. HYPOTHESIS/PURPOSE: The purpose of this study was to compare PTSA between pediatric patients sustaining a primary PCL tear compared with age- and sex-matched controls. It was hypothesized that pediatric patients sustaining a PCL tear would have a decreased PTSA compared with controls, with decreased PTSA being associated with higher odds of PCL injury. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: The records of all patients sustaining a PCL injury between 2006 and 2021 at a level 1 pediatric trauma center were reviewed. Patients aged ≤18 years with magnetic resonance imaging-confirmed PCL tear were included. Excluded were patients with concomitant anterior cruciate ligament tears, previous PCL reconstruction, or previous coronal plane realignment. A control cohort, with their ligament shown as intact on magnetic resonance imaging scans, was matched based on age and sex. PTSA was measured on lateral radiographs of the injured knee or tibia. The mean PTSA was compared between cohorts, and odds ratios were calculated based on the normal slope range (7°-10°) described in the literature, an upper range (>10°), and a lower range (<7°). Inter- and intrarater reliability were determined via calculation of an intraclass correlation coefficient. RESULTS: Of the 98 patients who sustained a PCL injury in this study period, 59 (60%) met inclusion criteria, and 59 healthy knee controls were matched. There were no differences between the cohorts for age (P = .90), sex (P > .99), or body mass index (P = .74). The PCL cohort had a lower mean ± SD PTSA compared with the control group (5.9°± 2.7° vs 7.3°± 4.3°; P = .03). PTSA <7° was associated with a 2.8 (95% CI, 1.3-6.0; P = .01) times risk of PCL tear. Conversely, PTSA >10° was associated with a 0.27 (95% CI, 0.09-0.81; P = .02) times risk of PCL tear. These PTSA measurements demonstrated acceptable intrarater and interrater reliability. CONCLUSION: PTSA <7° was associated with an increased odds of PCL injury, whereas a slope >10° was associated with a decreased odds of PCL injury in a pediatric population. These findings corroborate similar outcomes in adult studies; however, further studies are needed to elucidate PTSA as a risk factor for PCL injury.


Assuntos
Ligamento Cruzado Posterior , Tíbia , Humanos , Feminino , Masculino , Ligamento Cruzado Posterior/lesões , Ligamento Cruzado Posterior/diagnóstico por imagem , Adolescente , Criança , Tíbia/diagnóstico por imagem , Traumatismos do Joelho/diagnóstico por imagem , Fatores de Risco , Estudos Retrospectivos , Estudos de Casos e Controles , Imageamento por Ressonância Magnética , Radiografia , Estudos de Coortes
3.
J Pediatr Orthop ; 44(5): 316-321, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38385205

RESUMO

BACKGROUND: Patients with developmental dysplasia of the hip may require pelvic osteotomies to improve acetabular coverage. The purpose of this study was to compare the changes in acetabular version, tilt, and regional coverage angles following the San Diego acetabuloplasty (SDA), the modified San Diego acetabuloplasty (mSDA), and the Pemberton acetabuloplasty (PA). METHODS: Fourteen patients with developmental dysplasia of the hip and computed tomography (CT) imaging were identified. From CT images, 2 identical pelvises were 3-dimensional-printed for each patient. Bone was printed with rigid material, and cartilage with flexible material. For each model pair, the SDA was performed on one and the PA was performed on the other. CT scans were obtained before and after acetabuloplasties. Next, the bone graft in the SDA model was moved anteriorly, representing the mSDA, and the model was rescanned. Acetabular version, tilt, and coverage angles (posterior, superior-posterior, superior, superior-anterior, and anterior) were calculated. Preoperative to postoperative differences were compared (repeated measures analysis of variance or Wilcoxon signed rank test). The significance was set to P <0.05. RESULTS: The mean age at CT was 5.8±1.2 years (range: 3.9 to 7.5 y). All 3 procedures (SDA, mSDA, and PA) significantly increased acetabular tilt; P <0.045), with a similar change observed for all 3 ( P =0.868). PA was the only procedure to significantly decrease relative acetabular version (6.5±6.5 degrees, preoperative: 12.9±5.3 degrees; P =0.004). Both the SDA and mSDA procedures significantly increased coverage in the superior-posterior octant (SDA: 92.6±9.3 degrees, mSDA: 92.3±9.8 degrees, preoperative: 81.9±9.5 degrees; P <0.02), with a similar percent change among the 2 ( P =1.0). All 3 procedures significantly increased superior coverage ( P <0.04); the increase was similar among the 3 ( P =0.205). The PA was the only procedure to produce a significant increase in coverage in the superior-anterior octant (91.0±16.7 degrees, preoperative: 74.0±12.1 degrees; P =0.005) or the anterior octant (50.7±11.7 degrees, preoperative: 45.8±8.9 degrees; P =0.012). CONCLUSIONS: The SDA and mSDA procedures produced similar postoperative changes, primarily in the superior and superior-posterior acetabular octants. Placing the graft more anteriorly did not increase anterior coverage in the mSDA, and only the PA increased coverage in the superior and superior-anterior acetabular octants.


Assuntos
Acetabuloplastia , Displasia do Desenvolvimento do Quadril , Humanos , Pré-Escolar , Criança , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Pelve/cirurgia , Impressão Tridimensional , Estudos Retrospectivos
4.
Orthop J Sports Med ; 12(1): 23259671231222281, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38264411

RESUMO

Background: Despite the posterior cruciate ligament (PCL) being an essential stabilizer of the knee, there is a paucity of data regarding injury management in pediatric patients. Purpose/Hypothesis: The purpose of this study was to evaluate differences in outcomes after operative (OP) versus nonoperative (NOP) management of pediatric isolated (single-ligament) PCL tears. It was hypothesized that managing PCL tears operatively would lead to improved functional outcomes compared with NOP management, especially in the setting of an associated meniscal tear. Study Design: Cohort study; Level of evidence, 3. Methods: Pediatric patients with an isolated PCL injury between 2006 and 2020 were identified and grouped according to whether they had a concomitant meniscal tear (PCL+M) or no meniscal tear (PCL-M). These cohorts were further sorted into OP, NOP, and nonoperative converted to operative (NOP2OP) treatment cohorts. Outcome data collected included Lysholm score, current activity level, and whether the patient returned to sports after treatment. Results: A total of 48 patients (49 knees) met study inclusion criteria (31 male, 18 female; mean age at injury, 15.6 years; age range, 8.3-18.9 years). There were 37 knees in the PCL-M cohort (30 NOP, 2 NOP2OP, and 5 OP) and 12 knees in the PCL+M cohort (4 NOP, 4 NOP2OP, and 4 OP). The mean duration of follow-up was 6.2 years (range, 2.4-15.7 years). The mean Lysholm scores were not significantly different between the OP and NOP knees in either the PCL-M cohort (P = .582) or the PCL+M cohort (P = .570); however, the PCL-M cohort overall had significantly higher scores compared with the PCL+M cohort (92.7 ± 13.0 vs 82.8 ± 18.8, respectively; P = .019). Conclusion: The pediatric patients in this series had similar functional outcomes when managed operatively or nonoperatively for their single-ligament PCL tear. When considering concomitant meniscal injury, the results indicated that children with meniscal injury had a worse outcome than those without a meniscal injury. Shared decision-making with patients and their family should take these results into consideration.

5.
JCO Clin Cancer Inform ; 8: e2300119, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38166233

RESUMO

PURPOSE: Pancreatic cancer currently holds the position of third deadliest cancer in the United States and the 5-year survival rate is among the lowest for major cancers at just 12%. Thus, continued research efforts to better understand the clinical and molecular underpinnings of pancreatic cancer are critical to developing both early detection methodologies as well as improved therapeutic options. This study introduces Pancreatic Cancer Action Network's (PanCAN's) SPARK, a cloud-based data and analytics platform that integrates patient health data from the PanCAN's research initiatives and aims to accelerate pancreatic cancer research by making real-world patient health data and analysis tools easier to access and use. MATERIALS AND METHODS: The SPARK platform integrates clinical, molecular, multiomic, imaging, and patient-reported data generated from PanCAN's research initiatives. The platform is built on a cloud-based infrastructure powered by Velsera. Cohort exploration and browser capabilities are built using Velsera ARIA, a specialized product for leveraging clinicogenomic data to build cohorts, query variant information, and drive downstream association analyses. Data science and analytic capabilities are also built into the platform allowing researchers to perform simple to complex analysis. RESULTS: Version 1 of the SPARK platform was released to pilot users, who represented diverse end users, including molecular biologists, clinicians, and bioinformaticians. Included in the pilot release of SPARK are deidentified clinical (including treatment and outcomes data), molecular, multiomic, and whole-slide pathology images for over 600 patients enrolled in PanCAN's Know Your Tumor molecular profiling service. CONCLUSION: The pilot release of the SPARK platform introduces qualified researchers to PanCAN real-world patient health data and analytical resources in a centralized location.


Assuntos
Computação em Nuvem , Neoplasias Pancreáticas , Humanos , Estados Unidos/epidemiologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/epidemiologia , Neoplasias Pancreáticas/genética , Ciência de Dados , Taxa de Sobrevida
6.
J Am Med Inform Assoc ; 30(7): 1293-1300, 2023 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-37192819

RESUMO

Research increasingly relies on interrogating large-scale data resources. The NIH National Heart, Lung, and Blood Institute developed the NHLBI BioData CatalystⓇ (BDC), a community-driven ecosystem where researchers, including bench and clinical scientists, statisticians, and algorithm developers, find, access, share, store, and compute on large-scale datasets. This ecosystem provides secure, cloud-based workspaces, user authentication and authorization, search, tools and workflows, applications, and new innovative features to address community needs, including exploratory data analysis, genomic and imaging tools, tools for reproducibility, and improved interoperability with other NIH data science platforms. BDC offers straightforward access to large-scale datasets and computational resources that support precision medicine for heart, lung, blood, and sleep conditions, leveraging separately developed and managed platforms to maximize flexibility based on researcher needs, expertise, and backgrounds. Through the NHLBI BioData Catalyst Fellows Program, BDC facilitates scientific discoveries and technological advances. BDC also facilitated accelerated research on the coronavirus disease-2019 (COVID-19) pandemic.


Assuntos
COVID-19 , Computação em Nuvem , Humanos , Ecossistema , Reprodutibilidade dos Testes , Pulmão , Software
7.
Gland Surg ; 12(4): 548-554, 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37200930

RESUMO

Background: Ectopic parathyroid tissue can pose difficulties in diagnosis, management, and resection of adenomas in patients with hyperparathyroidism. The use of multimodal pre-operative imaging is recommended due to the diverse anatomic presentation of parathyroid adenomas and the potential presence of multiple adenomas. Resection failure still can occur, however, indocyanine green (ICG) fluorescence imaging is an intraoperative tool that has potential to help address this challenge. In the case which follows we demonstrate the use of ICG fluorescence imaging to assist in successful resection of a parathyroid adenoma located within the carotid sheath. Case Description: We present the case of a 75-year-old woman with primary hyperparathyroidism due to a parathyroid adenoma localized to the left carotid sheath, posterior to the carotid artery. Careful resection was aided by ICG fluorescence guidance allowing for complete resection and immediate postoperative restoration of normal parathyroid hormone and calcium levels. The patient had no peri-operative complications and had an unremarkable post-operative course. Conclusions: The anatomical heterogeneity of parathyroid gland adenomas within and around the carotid sheath presents a unique diagnostic and surgical scenario; however, the use of intra-operative ICG, as presented in this case, has important implications for endocrine surgeons and surgical trainees alike. This tool provides improved intra-operative identification of the parathyroid tissue allowing for safe resection, especially in cases involving critical anatomical structures.

8.
J Pediatr Orthop B ; 31(5): 434-441, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34678852

RESUMO

The ideal technique to measure medial epicondyle humerus fracture displacement minimizes radiation exposure while maximizing measurement accuracy and reliability. This study compares the radiation exposure and accuracy of displacement measurements of the four-view X-ray examination (XR), computed tomography (CT) and in-clinic cone-beam CT (CBCT). A cadaveric humerus underwent medial epicondyle osteotomy. The fragment was fixed to the humerus at clinically relevant displacements (6 to 18 mm). Dosimeters were placed around the distal humerus and simulating thyroid location. XR, CT and CBCT were performed at each displacement. Four pediatric orthopedists measured the maximum linear displacement on each XR and 3D reconstruction of the CT and CBCT images. Focal (elbow location) and thyroid radiation exposure was compared between modalities. Intra- and interclass correlation coefficients (ICC) for displacement measurements were determined. Mean focal radiation exposures for XR, CT and CBCT were 0.008, 2.061 and 0.478 rad, respectively (P = 0.001). Exposures 10 inches from the elbow for XR, CT and CBCT were 0.001, 0.066 and 0.010 rad, respectively (P = 0.006). At 12 inches, there was no significant difference in exposure between XR and CBCT ( P = 0.114). Intra- and interobserver reliabilities were excellent for all measures, except lateral x-ray. CBCT and CT had significantly less deviation from the actual displacement compared to XR ( P < 0.05). In-office CBCT of the elbow exposes patients to significantly less radiation than conventional CT. All X-ray images (except lateral), CT and CBCT had equal reliability in evaluating medial epicondyle fractures, which contrasts with previous evidence.


Assuntos
Fraturas do Úmero , Criança , Tomografia Computadorizada de Feixe Cônico , Humanos , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Úmero/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA