Clin Implant Dent Relat Res ; 15(2): 160-5, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21682842

RESUMO

AIM: The study aims to provide objective data for the displacement of titanium screw implants in trabecular bone specimens. One hundred Semados implants (Bego, Bremen, Germany) were inserted in bovine type IV bone specimens. All implants had a diameter of 3.75 mm; 50 implants had a length of 8.5 mm and 50 implants had a length of 15 mm. Insertion torque was determined at intervals of 10, 20, and 30 Ncm. Implants were loaded horizontally with 10, 20, and 30 N for 2 seconds. An indicator strip was attached to the implant abutment to allow direct observation of implant movement relative to the bone surface. Horizontal displacement was assessed with an accuracy of measurement of 10 µm. Seven implants got lost by visible loosening. Degree of displacement was subject to evaluation with all others. Those implants showed a mean displacement of 59 µm for 10 N (n = 100), 173 µm for 20 N (n = 99), and 211 µm for 30 N (n = 93). The mean displacement of 15-mm implants (16, 37, 51 µm) was significantly lower compared with 8.5-mm implants (103, 311, 396 µm) corresponding to 10, 20, and 30 N as lateral loads. CONCLUSIONS: Displacement of screw implants in trabecular bone can be detected and visualized using commercially available endoscopes with a high magnification. A lateral load of 20 N indicates a mean displacement of over 100 µm and therefore results in a critical displacement.


Assuntos
Osso e Ossos/cirurgia , Implantes Dentários , Retenção em Prótese Dentária , Animais , Densidade Óssea/fisiologia , Bovinos , Materiais Dentários/química , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Endoscópios/classificação , Teste de Materiais , Movimento , Estresse Mecânico , Propriedades de Superfície , Fatores de Tempo , Titânio/química , Torque
2.
Implant Dent ; 20(5): 341-4, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21857232

RESUMO

BACKGROUND: It has previously been demonstrated that immediate full occlusal loading of freestanding anterior implants can be performed using cortical satellite implants, obtaining a success rate similar to conventional protocols. The aim of this report was to present the outcomes after 36 months after initial placement. METHODS: Twenty patients received 2 single-standing titanium screw implants, which were stabilized during healing time with cortical satellite implants. Immediately after surgery, mandibular overdentures were placed using ball attachments. The satellite implants were removed after 3 months. RESULTS: Implant survival analysis showed a 100% success rate. The following parameters were assessed during the study: Periotest values, -5.89 (minimum: -7.00, maximum: -4.00); radiographic assessment of bone resorption, 0.51 mm (minimum: 0.00 mm, maximum: 1.50 mm); and pocket probing depth, 2.60 mm (minimum: 1.00 mm, maximum: 8.00 mm). CONCLUSIONS: The results suggest that immediate loading of freestanding implants stabilized with satellite implants is a successful concept at 3 years observation time.


Assuntos
Implantes Dentários para Um Único Dente , Retenção em Prótese Dentária , Carga Imediata em Implante Dentário/métodos , Idoso , Idoso de 80 Anos ou mais , Perda do Osso Alveolar/classificação , Perda do Osso Alveolar/diagnóstico por imagem , Planejamento de Prótese Dentária , Retenção em Prótese Dentária/instrumentação , Prótese Dentária Fixada por Implante , Retenção de Dentadura/instrumentação , Revestimento de Dentadura , Feminino , Seguimentos , Humanos , Carga Imediata em Implante Dentário/instrumentação , Masculino , Mandíbula/cirurgia , Pessoa de Meia-Idade , Osseointegração/fisiologia , Bolsa Periodontal/classificação , Estudos Prospectivos , Radiografia , Análise de Sobrevida , Resultado do Tratamento