Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Med Image Anal ; 97: 103230, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38875741

RESUMO

Challenges drive the state-of-the-art of automated medical image analysis. The quantity of public training data that they provide can limit the performance of their solutions. Public access to the training methodology for these solutions remains absent. This study implements the Type Three (T3) challenge format, which allows for training solutions on private data and guarantees reusable training methodologies. With T3, challenge organizers train a codebase provided by the participants on sequestered training data. T3 was implemented in the STOIC2021 challenge, with the goal of predicting from a computed tomography (CT) scan whether subjects had a severe COVID-19 infection, defined as intubation or death within one month. STOIC2021 consisted of a Qualification phase, where participants developed challenge solutions using 2000 publicly available CT scans, and a Final phase, where participants submitted their training methodologies with which solutions were trained on CT scans of 9724 subjects. The organizers successfully trained six of the eight Final phase submissions. The submitted codebases for training and running inference were released publicly. The winning solution obtained an area under the receiver operating characteristic curve for discerning between severe and non-severe COVID-19 of 0.815. The Final phase solutions of all finalists improved upon their Qualification phase solutions.


Assuntos
COVID-19 , SARS-CoV-2 , Tomografia Computadorizada por Raios X , Humanos , Inteligência Artificial
2.
IEEE Trans Biomed Eng ; 61(1): 4-15, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24626769

RESUMO

An approach for extracting the radial force load on an implanted stent from medical images is proposed. To exemplify the approach, a system is presented which computes a radial force estimation from computer tomography images acquired from patients who underwent transcatheter aortic valve implantation (TAVI). The deformed shape of the implanted valve prosthesis' Nitinol frame is extracted from the images. A set of displacement vectors is computed that parameterizes the observed deformation. An iterative relaxation algorithm is employed to adapt the information extracted from the images to a finite-element model of the stent, and the radial components of the interaction forces between the stent and the tissue are extracted. For the evaluation of the method, tests were run using the clinical data from 21 patients. Stent modeling and extraction of the radial forces were successful in 18 cases. Synthetic test cases were generated, in addition, for assessing the sensitivity to the measurement errors. In a sensitivity analysis, the geometric error of the stent reconstruction was below 0.3 mm, which is below the image resolution. The distribution of the radial forces was qualitatively and quantitatively reasonable. An uncertainty remains in the quantitative evaluation of the radial forces due to the uncertainty in defining a radial direction on the deformed stent. With our approach, the mechanical situation of TAVI stents after the implantation can be studied in vivo, which may help to understand the mechanisms that lead to the complications and improve stent design.


Assuntos
Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Processamento de Imagem Assistida por Computador/métodos , Stents , Ligas , Valva Aórtica/cirurgia , Fenômenos Biomecânicos , Calcinose , Análise de Elementos Finitos , Humanos , Desenho de Prótese
3.
IEEE Trans Vis Comput Graph ; 20(12): 2704-13, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26356984

RESUMO

Transcatheter aortic valve implantation (TAVI) is a minimally-invasive method for the treatment of aortic valve stenosis in patients with high surgical risk. Despite the success of TAVI, side effects such as paravalvular leakages can occur postoperatively. The goal of this project is to quantitatively analyze the co-occurrence of this complication and several potential risk factors such as stent shape after implantation, implantation height, amount and distribution of calcifications, and contact forces between stent and surrounding structure. In this paper, we present a two-dimensional visualization (stent maps), which allows (1) to comprehensively display all these aspects from CT data and mechanical simulation results and (2) to compare different datasets to identify patterns that are typical for adverse effects. The area of a stent map represents the surface area of the implanted stent - virtually straightened and uncoiled. Several properties of interest, like radial forces or stent compression, are displayed in this stent map in a heatmap-like fashion. Important anatomical landmarks and calcifications are plotted to show their spatial relation to the stent and possible correlations with the color-coded parameters. To provide comparability, the maps of different patient datasets are spatially adjusted according to a corresponding anatomical landmark. Also, stent maps summarizing the characteristics of different populations (e.g. with or without side effects) can be generated. Up to this point several interesting patterns have been observed with our technique, which remained hidden when examining the raw CT data or 3D visualizations of the same data. One example are obvious radial force maxima between the right and non-coronary valve leaflet occurring mainly in cases without leakages. These observations confirm the usefulness of our approach and give starting points for new hypotheses and further analyses. Because of its reduced dimensionality, the stent map data is an appropriate input for statistical group evaluation and machine learning methods.


Assuntos
Gráficos por Computador , Modelos Cardiovasculares , Stents/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Humanos , Processamento de Imagem Assistida por Computador , Modelos Estatísticos
4.
Artigo em Inglês | MEDLINE | ID: mdl-24109786

RESUMO

Transcatheter aortic valve implantation (TAVI) is a minimally invasive off-pump procedure to replace diseased aortic heart valves. Known complications include paravalvular leaks, atrioventricular blocks, coronary obstruction and annular rupture. Careful procedure planning including appropriate stent selection and sizing are crucial. Few patient-specific geometric parameters, like annular diameters, annular perimeter and measurement of the distance to the coronary ostia, are currently used within this process. Biomechanical simulation allows the consideration of extracted anatomy and material parameters for the intervention, which may improve planning and execution phases. We present a simulation workflow using a fully segmented aortic root anatomy, which was extracted from pre-operative CT-scan data and apply individual material models and parameters to predict the procedure outcome. Our results indicate the high relevance of calcification location and size for intervention planning, which are not sufficiently considered at this time. Our analysis can further provide guidance for accurate, patient-specific device positioning and future adaptations to stent design.


Assuntos
Calcinose/patologia , Simulação por Computador , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Calcinose/diagnóstico por imagem , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/patologia , Humanos , Stents , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA