Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 94(4)2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38081262

RESUMO

We describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion-photon couplings above 10-13 Ge V-1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7-4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

2.
Phys Rev Lett ; 131(10): 101002, 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37739367

RESUMO

We report the first result of a direct search for a cosmic axion background (CaB)-a relativistic background of axions that is not dark matter-performed with the axion haloscope, the Axion Dark Matter eXperiment (ADMX). Conventional haloscope analyses search for a signal with a narrow bandwidth, as predicted for dark matter, whereas the CaB will be broad. We introduce a novel analysis strategy, which searches for a CaB induced daily modulation in the power measured by the haloscope. Using this, we repurpose data collected to search for dark matter to set a limit on the axion photon coupling of a CaB originating from dark matter cascade decay via a mediator in the 800-995 MHz frequency range. We find that the present sensitivity is limited by fluctuations in the cavity readout as the instrument scans across dark matter masses. Nevertheless, we suggest that these challenges can be surmounted using superconducting qubits as single photon counters, and allow ADMX to operate as a telescope searching for axions emerging from the decay of dark matter. The daily modulation analysis technique we introduce can be deployed for various broadband rf signals, such as other forms of a CaB or even high-frequency gravitational waves.

3.
Phys Rev Lett ; 131(10): 102502, 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37739382

RESUMO

The absolute scale of the neutrino mass plays a critical role in physics at every scale, from the subatomic to the cosmological. Measurements of the tritium end-point spectrum have provided the most precise direct limit on the neutrino mass scale. In this Letter, we present advances by Project 8 to the cyclotron radiation emission spectroscopy (CRES) technique culminating in the first frequency-based neutrino mass limit. With only a cm^{3}-scale physical detection volume, a limit of m_{ß}<155 eV/c^{2} (152 eV/c^{2}) is extracted from the background-free measurement of the continuous tritium beta spectrum in a Bayesian (frequentist) analysis. Using ^{83m}Kr calibration data, a resolution of 1.66±0.19 eV (FWHM) is measured, the detector response model is validated, and the efficiency is characterized over the multi-keV tritium analysis window. These measurements establish the potential of CRES for a high-sensitivity next-generation direct neutrino mass experiment featuring low background and high resolution.

4.
Phys Rev Lett ; 131(8): 082502, 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37683153

RESUMO

We present an apparatus for detection of cyclotron radiation yielding a frequency-based ß^{±} kinetic energy determination in the 5 keV to 2.1 MeV range, characteristic of nuclear ß decays. The cyclotron frequency of the radiating ß particles in a magnetic field is used to determine the ß energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 Collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of ß^{-}'s from ^{6}He and ß^{+}'s from ^{19}Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for ß spectroscopy over the full (MeV) energy range. To our knowledge, this is the first direct observation of cyclotron radiation from individual highly relativistic ß's in a waveguide. This work establishes the application of CRES to a variety of nuclei, opening its reach to searches for new physics beyond the TeV scale via precision ß-decay measurements.

5.
Rev Sci Instrum ; 94(3): 033102, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37012755

RESUMO

This paper reports on a surface impedance measurement of a bulk metal niobium-titanium superconducting radio frequency (SRF) cavity in a magnetic field (up to 10 T). A novel method is employed to decompose the surface resistance contributions of the cylindrical cavity end caps and walls using measurements from multiple TM cavity modes. The results confirm that quality factor degradation of a NbTi SRF cavity in a high magnetic field is primarily from surfaces perpendicular to the field (the cavity end caps), while parallel surface resistances (the walls) remain relatively constant. This result is encouraging for applications needing high Q cavities in strong magnetic fields, such as the Axion Dark Matter eXperiment because it opens the possibility of hybrid SRF cavity construction to replace conventional copper cavities.

6.
Phys Rev Lett ; 129(20): 201301, 2022 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-36462025

RESUMO

Microwave cavities have been deployed to search for bosonic dark matter candidates with masses of a few µeV. However, the sensitivity of these cavity detectors is limited by their volume, and the traditionally employed half-wavelength cavities suffer from a significant volume reduction at higher masses. Axion dark matter experiment (ADMX)-Orpheus mitigates this issue by operating a tunable, dielectrically loaded cavity at a higher-order mode, which allows the detection volume to remain large. The ADMX-Orpheus inaugural run excludes dark photon dark matter with kinetic mixing angle χ>10^{-13} between 65.5 µeV (15.8 GHz) and 69.3 µeV (16.8 GHz), marking the highest-frequency tunable microwave cavity dark matter search to date.

7.
Phys Rev Lett ; 127(26): 261803, 2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-35029490

RESUMO

We report the results from a haloscope search for axion dark matter in the 3.3-4.2 µeV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the Kim-Shifman-Vainshtein-Zakharov model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.

8.
Rev Sci Instrum ; 92(12): 124502, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34972408

RESUMO

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66-3.1 µeV mass range with Dine-Fischler-Srednicki-Zhitnisky sensitivity [Du et al., Phys. Rev. Lett. 120, 151301 (2018) and Braine et al., Phys. Rev. Lett. 124, 101303 (2020)]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

9.
Phys Rev Lett ; 124(24): 241101, 2020 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-32639799

RESUMO

Axions are a promising cold dark matter candidate. Haloscopes, which use the conversion of axions to photons in the presence of a magnetic field to detect axions, are the basis of microwave cavity searches such as the Axion Dark Matter eXperiment (ADMX). To search for lighter, low frequency axions in the sub- 2×10^{-7} eV (50 MHz) range, a tunable lumped-element LC circuit has been proposed. For the first time, through ADMX SLIC (Superconducting LC Circuit Investigating Cold Axions), a resonant LC circuit was used to probe this region of axion mass-coupling space. The detector used a superconducting LC circuit with piezoelectric driven capacitive tuning. The axion mass and corresponding frequency ranges 1.7498-1.7519×10^{-7} eV (42.31-42.36 MHz), 1.7734-1.7738×10^{-7} eV (42.88-42.89 MHz), and 1.8007-1.8015×10^{-7} eV (43.54-43.56 MHz) were covered at magnetic fields of 4.5 T, 5.0 T, and 7.0 T, respectively. Exclusion results from the search data, for coupling below 10^{-12} GeV^{-1}, are presented.

10.
Phys Rev Lett ; 124(10): 101303, 2020 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-32216421

RESUMO

This Letter reports on a cavity haloscope search for dark matter axions in the Galactic halo in the mass range 2.81-3.31 µeV. This search utilizes the combination of a low-noise Josephson parametric amplifier and a large-cavity haloscope to achieve unprecedented sensitivity across this mass range. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics.

11.
Phys Rev Lett ; 120(15): 151301, 2018 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-29756850

RESUMO

This Letter reports the results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 µeV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at subkelvin temperatures, thereby reducing thermal noise as well as the excess noise from the ultralow-noise superconducting quantum interference device amplifier used for the signal power readout. Ongoing searches will provide nearly definitive tests of the invisible axion model over a wide range of axion masses.

12.
Phys Rev Lett ; 121(26): 261302, 2018 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-30636160

RESUMO

The µeV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, higher mass, searches. This testbed experiment lives inside of and operates in tandem with the main ADMX experiment. The Sidecar experiment excludes masses in three widely spaced frequency ranges (4202-4249, 5086-5799, and 7173-7203 MHz). In addition, Sidecar demonstrates the successful use of a piezoelectric actuator for cavity tuning. Finally, this publication is the first to report data measured using both the TM_{010} and TM_{020} modes.

13.
Phys Rev Lett ; 114(16): 162501, 2015 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-25955048

RESUMO

It has been understood since 1897 that accelerating charges must emit electromagnetic radiation. Although first derived in 1904, cyclotron radiation from a single electron orbiting in a magnetic field has never been observed directly. We demonstrate single-electron detection in a novel radio-frequency spectrometer. The relativistic shift in the cyclotron frequency permits a precise electron energy measurement. Precise beta electron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay end point, and this work demonstrates a fundamentally new approach to precision beta spectroscopy for future neutrino mass experiments.

14.
Phys Rev Lett ; 105(5): 051801, 2010 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-20867906

RESUMO

Scalar fields with a "chameleon" property, in which the effective particle mass is a function of its local environment, are common to many theories beyond the standard model and could be responsible for dark energy. If these fields couple weakly to the photon, they could be detectable through the afterglow effect of photon-chameleon-photon transitions. The ADMX experiment was used in the first chameleon search with a microwave cavity to set a new limit on scalar chameleon-photon coupling ßγ excluding values between 2×10(9) and 5×10(14) for effective chameleon masses between 1.9510 and 1.9525 µeV.

15.
Phys Rev Lett ; 104(4): 041301, 2010 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-20366699

RESUMO

Axions in the microeV mass range are a plausible cold dark-matter candidate and may be detected by their conversion into microwave photons in a resonant cavity immersed in a static magnetic field. We report the first result from such an axion search using a superconducting first-stage amplifier (SQUID) replacing a conventional GaAs field-effect transistor amplifier. This experiment excludes KSVZ dark-matter axions with masses between 3.3 microeV and 3.53 microeV and sets the stage for a definitive axion search utilizing near quantum-limited SQUID amplifiers.

16.
Phys Rev Lett ; 105(17): 171801, 2010 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-21231034

RESUMO

Hidden U(1) gauge symmetries are common to many extensions of the standard model proposed to explain dark matter. The hidden gauge vector bosons of such extensions may mix kinetically with standard model photons, providing a means for electromagnetic power to pass through conducting barriers. The axion dark matter experiment detector was used to search for hidden vector bosons originating in an emitter cavity driven with microwave power. We exclude hidden vector bosons with kinetic couplings χ>3.48×10⁻8 for masses less than 3 µeV. This limit represents an improvement of more than 2 orders of magnitude in sensitivity relative to previous cavity experiments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA