Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Sci Rep ; 13(1): 18122, 2023 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-37872272

RESUMO

The ability to perform accurate continuous glucose monitoring without blood sampling has revolutionised the management of diabetes. Newer methods that can allow measurements during longer periods are necessary to substantially improve patients' quality of life. This paper presents an alternative method for glucose monitoring which is based on electrical impedance spectroscopy. A battery-less implantable bioimpedance spectroscope was designed, built, and used in an in vivo study on pigs. After a recovery period of 14 days post surgery, a total of 236 subcutaneous bioimpedance measurements obtained from intravenous glucose tolerance tests, with glucose concentration ranges between 77.4 and 523.8 mg/dL, were analyzed. The results show that glucose concentrations estimated by subcutaneous bioimpedance measurements correlate very well to the blood glucose reference values. The pigs were clinically healthy throughout the study, and the postmortem examinations revealed no signs of adverse effects related to the sensor. The implantation of the sensor requires minor surgery. The implant, being externally powered, could in principle last indefinitely. These encouraging results demonstrate the potential of the bioimpedance method to be used in future continuous glucose monitoring systems.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Humanos , Animais , Suínos , Automonitorização da Glicemia/métodos , Espectroscopia Dielétrica , Qualidade de Vida
2.
J Equine Vet Sci ; 121: 104204, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36586522

RESUMO

Streptococcus equi subsp. equi (S. equi) is transmitted via contact with infected horses or fomites such as equipment or surfaces of the stable environment. Effective cleaning and sanitation is essential to minimize risk of fomite-associated infections. This study assessed the effectiveness of cleaning and sanitation of experimentally S. equi contaminated materials and equipment found in stables. Wood, concrete, plastic, leather halters, leather gloves and polyester webbing halters were inoculated with a 24-hour culture S. equi laboratory strain. In addition, selected materials were inoculated with a clinical strain of S. equi. Three days post inoculation all materials were sampled for retention of viable S. equi and a subset of each material was cleaned and sanitized. After an additional 2 days all treated and untreated materials were sampled for continued retention of viable S. equi. Separate subsets of contaminated polyester halter material were washed at 40°C with or without drying at 70°C, or washed at 60°C. After cleaning and sanitation, all samples except polyester halters were culture negative. Even before cleaning and sanitation leather appears to poorly support survival of S. equi. After washing at 40°C and tumble drying, 14 of 16 halters were culture positive, however culture negative when washed at 60°C. Routine cleaning and sanitation of fomites contaminated with S. equi was generally effective to eliminate viable bacteria. However, survival between materials and strains differed, with leather poorly permissive to S. equi survival even without cleaning, whereas polyester webbing halters retained viable S. equi even after washing at temperatures of 40°C.


Assuntos
Infecções Estreptocócicas , Streptococcus equi , Animais , Cavalos , Infecções Estreptocócicas/epidemiologia , Infecções Estreptocócicas/microbiologia , Infecções Estreptocócicas/veterinária , Saneamento , Poliésteres
4.
Lab Anim ; 55(6): 540-550, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34325556

RESUMO

Pig experiments often require anaesthesia, and a rapid stress-free induction is desired. Induction drugs may alter the subsequent anaesthesia. Therefore, the aim of the present study was to compare, in pigs, the effects of two different injectable anaesthetic techniques on the induction and on the physiological variables in a subsequent eight hours of total intravenous anaesthesia (TIVA). Twelve domestic castrates (Swedish Landrace/Yorkshire) 27‒31 kg were used. The pigs were randomly assigned to different induction drug combinations of zolazepam-tiletamine and medetomidine intramuscularly (ZTMe) or midazolam, ketamine intramuscularly and fentanyl intravenously (MiKF). Time from injection to unconsciousness was recorded and the ease of endotracheal intubation assessed. The TIVA infusion rate was adjusted according to the response exhibited from the nociceptive stimulus delivered by mechanically clamping the dewclaw. The time from injection to unconsciousness was briefer and intubation was easier in the ZTMe group. Results from the recorded heart rate, cardiac index and arterial blood pressure variables were satisfactorily preserved and cardiovascular function was maintained in both groups. Shivering was not observed in the ZTMe group, but was observed in four of the pigs in the MiKF group. The requirement of TIVA was lower in the ZTMe group. In conclusion, ZTMe had better results than MiKF in areas such as shorter induction time, better intubation scoring results and less adjustment and amount of TIVA required up to six hours of anaesthesia. The results may have been due to a greater depth of anaesthesia achieved with the ZTMe combination at the dose used.


Assuntos
Anestésicos , Zolazepam , Animais , Anestesia Geral , Medetomidina , Suínos , Tiletamina
5.
Animals (Basel) ; 11(6)2021 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-34063808

RESUMO

Reliable protocols for short-term anesthetics are essential to safeguard animal welfare during medical investigations. The aim of the study was to assess the adequacy and reliability of an anesthetic protocol and to evaluate physiological and clinical responses, in relation to the drug plasma concentrations, for pigs undergoing short-term anesthesia. A second aim was to see whether an intravenous dosage could prolong the anesthesia. The anesthesia was induced by an intramuscular injection of dexmedetomidine, tiletamine-zolazepam, and butorphanol in 12 pigs. In six of the pigs, a repeated injection intravenously of one-third of the initial dose was given after one hour. The physiological and clinical effects from induction to recovery were examined. Plasma concentrations of the drugs were analyzed and pharmacokinetic parameters were calculated. Each drug's absorption and time to maximal concentration were rapid. All pigs were able to maintain spontaneous respiration. The route of administration did not alter the half-life of the drug. The results suggest that intramuscular administration of the four-drug combination provides up to two hours of anesthesia with stable physiological parameters and an acceptable level of analgesia while maintaining spontaneous respiration. A repeated intravenous injection may be used to extend the time of anesthesia by 30 min.

6.
Equine Vet J ; 52(6): 884-890, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32052491

RESUMO

BACKGROUND: Endoscopic examinations are essential for diagnosis and treatment of strangles (S equi infection) in horses. However, even after disinfection, endoscopes may retain viable bacteria or bacterial DNA. Twitches are commonly used during endoscopic examinations and can thus also potentially transmit the organism to other horses. OBJECTIVES: To evaluate the efficacy of different disinfectant methods to eliminate S equi from experimentally contaminated endoscopes and twitches and the effectiveness of field disinfection of endoscopes used in sampling carriers of S equi. STUDY DESIGN: Experimental contamination and observational field study. METHODS: One endoscope and 30 twitches were contaminated with standardised S equi broth solutions. The endoscope was disinfected following three protocols using various disinfectants for manual disinfection. A fourth protocol used an automated endoscope reprocessor (AER). The twitches (n = 30) were disinfected following eight different disinfecting protocols. Three endoscopes used in sampling for silent carriers were disinfected following a field-based protocol. After each protocol the endoscopes and twitches were sampled for S equi by culture and qPCR. RESULTS: Following experimental contamination all endoscope disinfection protocols, apart from 1/6 of the ethanol protocol were S equi culture negative. However, no endoscope disinfection protocol completely eliminated retention of S equi DNA. Field disinfection of endoscopes after sampling carriers yielded no culture positives and all but one (13/14) were qPCR negative. All twitches disinfected following experimental contamination were culture negative but sodium hypochlorite was the only disinfectant that completely eliminated detection of S equi DNA. MAIN LIMITATIONS: Experimental contamination may not reflect the numbers of S equi transferred to endoscopes or twitches during use on silent carriers and purulent secretions from infected horses may influence survival of S equi. CONCLUSIONS: While most disinfection methods appear to ensure removal of cultivable S equi, residual DNA can remain on both endoscopes and twitches.


Assuntos
Desinfetantes/farmacologia , Doenças dos Cavalos/diagnóstico , Doenças dos Cavalos/prevenção & controle , Infecções Estreptocócicas/veterinária , Streptococcus equi , Animais , Desinfecção , Endoscópios , Cavalos
7.
Lab Anim ; 54(5): 469-478, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31648591

RESUMO

The pig is commonly used in renal transplantation studies since the porcine kidney resembles the human kidney. To meet the requirements of intense caretaking and examination without stress, a 2-week socialisation and training programme was developed. Conventional cross-breed pigs (n = 36) with high health status were trained for 15 min/day in a four-step training programme before kidney transplantation. The systematic training resulted in calm animals, which allowed for ultrasound examination, blood sampling and urine sampling without restraint. When a 2-methacryloyloxyethyl phosphorylcholine polymer-coated jugular catheter introduced via the auricular vein was used for post-operative blood sampling, clotting was avoided. To assess renal function, urinary output was observed and creatinine and cystatin C were measured; the latter was not found to be useful in recently transplanted pigs. The results presented contribute to the 3Rs (refine, reduce, replace).


Assuntos
Aclimatação , Transplante de Rim , Período Pós-Operatório , Período Pré-Operatório , Sus scrofa/fisiologia , Criação de Animais Domésticos , Animais , Biomarcadores/urina , Coleta de Amostras Sanguíneas , Cateterismo , Cistatina C/sangue , Feminino , Taxa de Filtração Glomerular , Rim/diagnóstico por imagem , Lactação , Masculino , Modelos Animais , Socialização , Ultrassonografia/estatística & dados numéricos , Bexiga Urinária/diagnóstico por imagem , Coleta de Urina
8.
Acta Diabetol ; 56(10): 1113-1120, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31028528

RESUMO

AIMS: Perfusion of the pancreas and the islets of Langerhans is sensitive to physiological stimuli and is dysregulated in metabolic disease. Pancreatic perfusion can be assessed by both positron emission tomography (PET) and magnetic resonance imaging (MRI), but the methods have not been directly compared or benchmarked against the gold-standard microsphere technique. METHODS: Pigs (n = 4) were examined by [15O]H2O PET and intravoxel incoherent motion (IVIM) MRI technique simultaneously using a hybrid PET/MRI scanner. The pancreatic perfusion was measured both at basal conditions and after intravenous (IV) administration of up to 0.5 g/kg glucose. RESULTS: Pancreatic perfusion increased by 35%, 157%, and 29% after IV 0.5 g/kg glucose compared to during basal conditions, as assessed by [15O]H2O PET, IVIM MRI, and microspheres, respectively. There was a correlation between pancreatic perfusion as assessed by [15O]H2O PET and IVIM MRI (r = 0.81, R2 = 0.65, p < 0.01). The absolute quantification of pancreatic perfusion (ml/min/g) by [15O]H2O PET was within a 15% error of margin of the microsphere technique. CONCLUSION: Pancreatic perfusion by [15O]H2O PET was in agreement with the microsphere technique assessment. The IVIM MRI method has the potential to replace [15O]H2O PET if the pancreatic perfusion is sufficiently large, but not when absolute quantitation is required.


Assuntos
Glucose/farmacologia , Pâncreas/irrigação sanguínea , Pâncreas/efeitos dos fármacos , Pâncreas/diagnóstico por imagem , Imagem de Perfusão/métodos , Animais , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Movimento (Física) , Isótopos de Oxigênio/farmacocinética , Radioisótopos de Oxigênio/farmacocinética , Pâncreas/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Suínos , Água/química , Água/metabolismo
9.
Macromol Biosci ; 19(5): e1800485, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30786149

RESUMO

Artificial surfaces that come into contact with blood induce an immediate activation of the cascade systems of the blood, leading to a thrombotic and/or inflammatory response that can eventually cause damage to the biomaterial or the patient, or to both. Heparin coating has been used to improve hemocompatibility, and another approach is 2-methacryloyloxyethyl phosphorylcholine (MPC)-based polymer coatings. Here, the aim is to evaluate the hemocompatibility of MPC polymer coating by studying the interactions with coagulation and complement systems using human blood in vitro model and pig in vivo model. The stability of the coatings is investigated in vitro and MPC polymer-coated catheters are tested in vivo by insertion into the external jugular vein of pigs to monitor the catheters' antithrombotic properties. There is no significant activation of platelets or of the coagulation and complement systems in the MPC polymer-coated one, which was superior in hemocompatibility to non-coated matrix surfaces. The protective effect of the MPC polymer coat does not decline after incubation in human plasma for up to 2 weeks. With MPC polymer-coated catheters, it is possible to easily draw blood from pig for 4 days in contrast to the case for non-coated catheters, in which substantial clotting is seen.


Assuntos
Coagulação Sanguínea , Catéteres , Materiais Revestidos Biocompatíveis/química , Proteínas do Sistema Complemento/metabolismo , Teste de Materiais , Metacrilatos/química , Fosforilcolina/análogos & derivados , Animais , Plaquetas/metabolismo , Feminino , Humanos , Masculino , Fosforilcolina/química , Suínos
11.
Nucl Med Biol ; 43(7): 397-402, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27179248

RESUMO

INTRODUCTION: Radiolabeled Exendin-4, a synthetic glucagon-like peptide-1 (GLP-1) analog, is used as a tracer for diagnostic purposes of ß-cells and in experimental animal research. Exendin-4 can be radiolabeled with (68)Ga, (111)In or (99m)Tc and used for positron emission tomography (PET) and single-photon emission computed tomography (SPECT) imaging to diagnose insulinomas, visualization of pancreatic ß-cell mass and transplanted Islets of Langerhans. In humans, Exendin-4 is widely used as a therapeutic agent for treatment of type 2 diabetes (T2D). The compound, which is administered subcutaneously (SC) may cause nausea, vomiting and a minor increase in the heart rate (HR). However, possible side-effects on cardiovascular functions after intravenous (IV) administration have not been reported. This study describes the Exendin-4 dose at which cardiovascular side-effects occur in pigs and cynomolgus monkeys. The IV effect of the tracer on insulin secretion is also investigated in pigs. METHODS: Seven clinically healthy littermate pigs (40days old) were used; three of them were made diabetic by streptozotocin (STZ). All pigs underwent PET imaging under general anesthesia to examine the glucagon-like peptide-1 receptor (GLP-1R) in ß-cells with radiolabeled Exendin-4. A baseline tracer dose IV [(68)Ga]Exendin-4 (0.025±0.010µg/kg) followed by a competition dose IV [(68)Ga]Exendin-4 (3.98±1.33µg/kg) 60min later were administered. Blood samples were taken and analyzed for insulin secretion by using ELISA. Cardiovascular and respiratory variables were monitored throughout the experiment. RESULTS: Immediately after administration of the high dose [(68)Ga]Exendin-4 the HR rose from 122±14 to 227±40bpm (p<0.01) and from 100±5 to 181±13bpm (p<0.01) in healthy non-diabetic and diabetes-induced pigs, respectively. The tachycardia was observed for >2h and one healthy non-diabetic pig suffered cardiac arrest 3h after the IV [(68)Ga]Exendin-4. Arrhythmia was detected by listening to the heart with a stethoscope up to 4days after the [(68)Ga]Exendin-4 injection. In all animals, no effect on the cardiovascular system was registered after the low dose of IV [(68)Ga]Exendin-4. Insulin secretion increased (p<0.05) when IV [(68)Ga]Exendin-4 was given in dosages ≥0.14µg/kg. CONCLUSIONS: Intravenous administration of ≥2.8µg/kg [(68)Ga]Exendin-4 resulted in severe tachycardia and arrhythmias in healthy non-diabetic and diabetes-induced pigs, and the insulin secretion was stimulated in healthy non-diabetic animals when ≥0.14µg/kg [(68)Ga]Exendin-4 was given.


Assuntos
Sistema Cardiovascular/efeitos dos fármacos , Insulina/metabolismo , Peptídeos/administração & dosagem , Peptídeos/efeitos adversos , Peçonhas/administração & dosagem , Peçonhas/efeitos adversos , Administração Intravenosa , Animais , Pressão Arterial/efeitos dos fármacos , Glicemia/metabolismo , Sistema Cardiovascular/diagnóstico por imagem , Relação Dose-Resposta a Droga , Exenatida , Feminino , Frequência Cardíaca/efeitos dos fármacos , Insulina/sangue , Secreção de Insulina , Masculino , Tomografia por Emissão de Pósitrons , Suínos
12.
Am J Vet Res ; 75(11): 949-55, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25350084

RESUMO

OBJECTIVE: To image the spatial distribution of pulmonary blood flow by means of scintigraphy, evaluate ventilation-perfusion (VA/Q) matching and pulmonary blood shunting (Qs/Qt) by means of the multiple inert gas elimination technique (MIGET), and measure arterial oxygenation and plasma endothelin-1 concentrations before, during, and after pulse-delivered inhaled nitric oxide (PiNO) administration to isoflurane-anesthetized horses in dorsal recumbency. ANIMALS: 3 healthy adult Standardbreds. PROCEDURES: Nitric oxide was pulsed into the inspired gases in dorsally recumbent isoflurane-anesthetized horses. Assessment of VA/Q matching, Qs/Qt, and Pao2 content was performed by use of the MIGET, and spatial distribution of pulmonary blood flow was measured by perfusion scintigraphy following IV injection of technetium Tc 99m-labeled macroaggregated human albumin before, during, and 30 minutes after cessation of PiNO administration. RESULTS: During PiNO administration, significant redistribution of blood flow from the dependent regions to the nondependent regions of the lungs was found and was reflected by improvements in VA/Q matching, decreases in Qs/Qt, and increases in Pao2 content, all of which reverted to baseline values at 30 minutes after PiNO administration. CONCLUSIONS AND CLINICAL RELEVANCE: Administration of PiNO in anesthetized dorsally recumbent horses resulted in redistribution of pulmonary blood flow from dependent atelectatic lung regions to nondependent aerated lung regions. Because hypoxemia is commonly the result of atelectasis in anesthetized dorsally recumbent horses, the addition of nitric oxide to inhaled gases could be used clinically to alleviate hypoxemia in horses during anesthesia.


Assuntos
Anestésicos Inalatórios , Cavalos/fisiologia , Hipóxia/veterinária , Isoflurano , Pulmão/irrigação sanguínea , Óxido Nítrico/administração & dosagem , Administração por Inalação , Adulto , Anestésicos Inalatórios/farmacologia , Animais , Artérias/efeitos dos fármacos , Gasometria/veterinária , Feminino , Frequência Cardíaca/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Humanos , Hipóxia/etiologia , Hipóxia/terapia , Isoflurano/farmacologia , Pulmão/diagnóstico por imagem , Masculino , Perfusão/veterinária , Atelectasia Pulmonar/fisiopatologia , Atelectasia Pulmonar/veterinária , Cintilografia , Respiração/efeitos dos fármacos
13.
Eur J Nucl Med Mol Imaging ; 41(9): 1800-10, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24643781

RESUMO

PURPOSE: The glucagon-like peptide-1 receptor (GLP-1R) has been proposed as a target for molecular imaging of beta cells. The feasibility of non-invasive imaging and quantification of GLP-1R in pancreas using the positron emission tomography (PET) tracer [(68)Ga]Ga-DO3A-VS-Cys(40)-Exendin-4 in non-diabetic and streptozotocin (STZ)-induced diabetic pigs treated with insulin was investigated. METHODS: Non-diabetic (n = 4) and STZ-induced diabetic pigs (n = 3) from the same litter were examined. Development of diabetes was confirmed by blood glucose values, clinical examinations and insulin staining of pancreatic sections post mortem. Tissue perfusion in the pancreas and kidneys was evaluated by [(15)O]water PET/computed tomography (CT) scans. The in vivo receptor specificity of [(68)Ga]Ga-DO3A-VS-Cys(40)-Exendin-4 was assessed by administration of either tracer alone or by competition with 3-6.5 µg/kg of Exendin-4. Volume of distribution and occupancy in the pancreas were quantified with a single tissue compartment model. RESULTS: [(15)O]water PET/CT examinations showed reduced perfusion in the pancreas and kidneys in diabetic pigs. [(68)Ga]Ga-DO3A-VS-Cys(40)-Exendin-4 uptake in the pancreas of both non-diabetic and diabetic pigs was almost completely abolished by co-injection of unlabeled Exendin-4 peptide. [(68)Ga]Ga-DO3A-VS-Cys(40)-Exendin-4 uptake did not differ between non-diabetic and diabetic pigs. In all animals, administration of the tracer resulted in an immediate increase in the heart rate (HR). CONCLUSION: Pancreatic uptake of [(68)Ga]Ga-DO3A-VS-Cys(40)-Exendin-4 was not reduced by destruction of beta cells in STZ-induced diabetic pigs.


Assuntos
Diabetes Mellitus Experimental/diagnóstico por imagem , Diabetes Mellitus Experimental/metabolismo , Saúde , Tomografia por Emissão de Pósitrons/métodos , Receptores de Glucagon/metabolismo , Animais , Biomarcadores/metabolismo , Diabetes Mellitus Experimental/tratamento farmacológico , Diabetes Mellitus Experimental/patologia , Feminino , Receptor do Peptídeo Semelhante ao Glucagon 1 , Frequência Cardíaca/efeitos dos fármacos , Insulina/farmacologia , Insulina/uso terapêutico , Células Secretoras de Insulina/diagnóstico por imagem , Células Secretoras de Insulina/efeitos dos fármacos , Células Secretoras de Insulina/metabolismo , Rim/diagnóstico por imagem , Rim/efeitos dos fármacos , Rim/metabolismo , Masculino , Tomografia por Emissão de Pósitrons/efeitos adversos , Traçadores Radioativos , Suínos , Água/metabolismo
14.
Vet Anaesth Analg ; 40(6): e9-e18, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22805284

RESUMO

OBJECTIVE: To assess oxygenation, ventilation-perfusion (V/Q) matching and plasma endothelin (ET-1) concentrations in healthy horses recovering from isoflurane anaesthesia administered with or without pulse-delivered inhaled nitric oxide (iNO). STUDY DESIGN: Prospective experimental trial. ANIMALS: Healthy adult Standardbred horses. METHODS: Horses were anaesthetized with isoflurane in oxygen and placed in lateral recumbency. Six control (C group) horses were anaesthetized without iNO delivery and six horses received pulse-delivered iNO (NO group). After 2.5 hours of anaesthesia isoflurane and iNO were abruptly discontinued, inhaled oxygen was reduced from 100% to approximately 30%, and the horses were moved to the recovery stall. At intervals during a 30-minute period following the discontinuation of anaesthesia, arterial and mixed venous blood gas values, shunt fraction (Qs/Qt), plasma ET-1 concentration, pulse rate and respiratory rate were measured or calculated. Repeated measures anova and a Bonferroni post hoc test was used to analyze data with significance set at p < 0.05. RESULTS: At all time points in the recovery period, NO horses maintained better arterial oxygenation (oxygen partial pressure: NO 13.2 ± 2.7-11.1 ± 2.7 versus C 6.7 ± 1.1-7.1 ± 1.1 kPa) and better V/Q matching (Qs/Qt NO 0.23 ± 0.05-0.14 ± 0.06 versus C 0.48 ± 0.03-0.32 ± 0.08%) than C horses. Mixed venous oxygenation was higher in NO for 25 minutes following the discontinuation of anaesthesia (NO 6.3 ± 0.2-4.5 ± 0.07 versus C 4.7 ± 0.6-3.7 ± 0.3 kPa). In both groups of horses arterial oxygenation remained fairly stable; venous oxygenation declined over this time period in the NO group but still remained higher than venous oxygen in the C group. ET-1 concentrations were higher at most time points in C than NO. Changes in other parameters were either minor or absent. CONCLUSIONS AND CLINICAL RELEVANCE: Delivery of iNO to healthy horses during anaesthesia results in better arterial and venous oxygenation and V/Q matching (as determined by lower Qs/Qt) and lower ET-1 concentrations throughout a 30-minute anaesthetic recovery period.


Assuntos
Anestesia por Inalação/veterinária , Anestésicos Inalatórios , Endotelina-1/sangue , Cavalos/sangue , Isoflurano , Óxido Nítrico , Oxigênio/sangue , Anestesia por Inalação/métodos , Animais , Gasometria/veterinária , Feminino , Cavalos/cirurgia , Masculino , Óxido Nítrico/administração & dosagem
15.
Am J Vet Res ; 69(3): 423-30, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18312143

RESUMO

OBJECTIVE: To assess physiologic responses and plasma endothelin (ET)-1 concentrations associated with abrupt cessation of nitric oxide (NO) inhalation in isoflurane-anesthetized horses. ANIMALS: 6 healthy adult Standardbreds. PROCEDURES: Horses were anesthetized with isoflurane in oxygen and placed in dorsal recumbency. Nitric oxide was pulsed into the respiratory tract for 2.5 hours, and then administration was abruptly discontinued. Just prior to commencement and at cessation of NO administration, and at intervals during a 30-minute period following cessation of NO inhalation, several variables including PaO(2), mean pulmonary artery pressure, venous admixture or pulmonary shunt fraction (Qs/Qt), and plasma ET-1 concentration were recorded or calculated. RESULTS: After cessation of NO inhalation, PaO(2) decreased slowly but significantly (172.7 +/- 29.8 mm Hg to 84.6 +/- 10.9 mm Hg) and Qs/Qt increased slowly but significantly (25 +/- 2% to 40 +/- 3%) over a 30-minute period. Mean pulmonary artery pressure increased slightly (14.0 +/- 1.3 mm Hg to 16.8 +/- 1 mm Hg) over the same time period. No change in serum ET-1 concentration was detected, and other variables did not change or underwent minor changes. CONCLUSIONS AND CLINICAL RELEVANCE: The improvement in arterial oxygenation during pulsed inhalation of NO to healthy isoflurane-anesthetized horses decreased only gradually during a 30-minute period following cessation of NO inhalation, and serum ET-1 concentration was not affected. Because a rapid rebound response did not develop, inhalation of NO might be clinically useful in the treatment of hypoxemia in healthy isoflurane-anesthetized horses.


Assuntos
Anestesia por Inalação/veterinária , Broncodilatadores/administração & dosagem , Endotelina-1/sangue , Cavalos/fisiologia , Óxido Nítrico/administração & dosagem , Administração por Inalação , Animais , Gasometria/veterinária , Pressão Sanguínea/efeitos dos fármacos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Cavalos/sangue , Masculino , Respiração/efeitos dos fármacos
16.
Vet Anaesth Analg ; 33(5): 307-12, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16916353

RESUMO

OBJECTIVE: To evaluate the effects of preoperative extradural morphine on the end-tidal isoflurane (Fe'ISO) concentration and on physiological variables in pigs undergoing abdominal surgery. STUDY DESIGN: Prospective, randomized, blinded study. ANIMALS: Fourteen healthy pigs (20 +/- 4 kg) undergoing intestinal cannulation. MATERIALS AND METHODS: Anaesthesia was induced with a combination of medetomidine (50 microg kg(-1)) and tiletamine-zolazepam (2.5 mg kg(-1)) injected intramuscularly, and was maintained with isoflurane in air and oxygen (FiO(2) = 50% O(2)). In the first group, morphine (0.1 mg kg(-1)) was administered extradurally before surgery. The second group received an equivalent volume of extradural saline as control. During the experiment, heart and respiratory rates, mean arterial blood pressure, tidal volume and minute ventilation were recorded every 10 minutes. The concentration of Fe'ISO was adjusted, according to the depth of anaesthesia, by an experienced animal nurse. Within treatment groups, time-related changes in Fe'ISO and physiological variables were analysed using a repeated measurement anova. Differences in data between treatment groups were analysed at specific time points using a Mann-Whitney U-test. Results are presented as mean +/- SD; p < 0.05 was considered as significant. RESULTS: After the onset of action of the morphine, the Fe'ISO required to maintain anaesthesia was significantly lower in the extradural morphine group compared with control. During the expected maximal effect of the drug, Fe'ISO was significantly lower in the morphine group (0.6 +/- 0.2%) than in the control group (0.9 +/- 0.2%). The decrease in Fe'ISO indicated that the onset of action of morphine was approximately 30 minutes after injection. No significant differences in other clinical variables were found between the groups. CONCLUSION: Pigs that received extradural morphine before abdominal surgery achieved surgical anaesthetic depth at a lower Fe'ISO concentration. CLINICAL RELEVANCE: Extradural morphine allows abdominal surgery to be performed at a lower Fe'ISO concentrations.


Assuntos
Abdome/cirurgia , Anestesia por Inalação/veterinária , Anestésicos Inalatórios/farmacocinética , Isoflurano/farmacocinética , Morfina/administração & dosagem , Morfina/farmacologia , Suínos/cirurgia , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/farmacologia , Anestesia por Inalação/métodos , Animais , Feminino , Injeções Epidurais , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA