Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Vitreoretin Dis ; 8(5): 577-586, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39318989

RESUMO

Purpose: To review sustained-release intraocular platforms used to treat diseases of the retina and choroid. Methods: A literature review of the current applications of biomaterials for sustained-release therapy in retinal and choroidal diseases was performed. Results: Retinal and choroidal diseases, such as neovascular age-related macular degeneration (nAMD), diabetic retinopathy (DR), diabetic macular edema (DME), and uveitis, are commonly treated using intravitreal (IVT) therapies that require frequent IVT injections. Multiple sustained-release options for IVT therapy have been approved by the US Food and Drug Administration for the treatment of inflammatory eye diseases, including noninfectious uveitis, infectious diseases, and exudative retinal diseases (eg, retinal venous occlusive disease and DME) using drugs such as fluocinolone acetonide, ganciclovir, and dexamethasone. The platforms for these drugs are biodegradable or nonbiodegradable. They use biomaterials such as polymers and hydrogels and are typically implanted surgically or injected into the vitreous, where they release the drug gradually over months or years. Building on these technologies, novel platforms are being studied that are intended to treat conditions including nAMD, DR, DME, and uveitis. These platforms are being tested for their safety, efficacy, and ability to reduce the injection and visit burden. Conclusions: Multiple sustained-release ocular drug-delivery platforms are currently commercially available, and many new sustained-release IVT platforms are being investigated. The hope is that meaningfully reducing the injection burden by extending intervals between treatments while maintaining optimal efficacy will improve long-term outcomes.

2.
PLoS One ; 19(6): e0304782, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38833447

RESUMO

PURPOSE: Pathological angiogenesis and vascular instability are observed in diabetic retinopathy (DR), diabetic macular edema (DME), and wet age-related macular degeneration (wAMD). Many receptor tyrosine kinases (RTKs) including vascular endothelial growth factor receptors (VEGFRs) contribute to angiogenesis, whereas the RTK TIE2 is important for vascular stability. Pan-VEGFR tyrosine kinase inhibitors (TKIs) such as vorolanib, sunitinib, and axitinib are of therapeutic interest over current antibody treatments that target only one or two ligands. This study compared the anti-angiogenic potential of these TKIs. METHODS: A kinase HotSpot™ assay was conducted to identify TKIs inhibiting RTKs associated with angiogenesis and vascular stability. Half-maximal inhibitory concentration (IC50) for VEGFRs and TIE2 was determined for each TKI. In vitro angiogenesis inhibition was investigated using a human umbilical vein endothelial cell sprouting assay, and in vivo angiogenesis was studied using the chorioallantoic membrane assay. Melanin binding was assessed using a melanin-binding assay. Computer modeling was conducted to understand the TIE2-axitinib complex as well as interactions between vorolanib and VEGFRs. RESULTS: Vorolanib, sunitinib, and axitinib inhibited RTKs of interest in angiogenesis and exhibited pan-VEGFR inhibition. HotSpot™ assay and TIE2 IC50 values showed that only axitinib potently inhibited TIE2 (up to 89%). All three TKIs effectively inhibited angiogenesis in vitro. In vivo, TKIs were more effective at inhibiting VEGF-induced angiogenesis than the anti-VEGF antibody bevacizumab. Of the three TKIs, only sunitinib bound melanin. TKIs differ in their classification and binding to VEGFRs, which is important because type II inhibitors have greater selectivity than type I TKIs. CONCLUSIONS: Vorolanib, sunitinib, and axitinib exhibited pan-VEGFR inhibition and inhibited RTKs associated with pathological angiogenesis. Of the three TKIs, only axitinib potently inhibited TIE2 which is an undesired trait as TIE2 is essential for vascular stability. The findings support the use of vorolanib for therapeutic inhibition of angiogenesis observed in DR, DME, and wAMD.


Assuntos
Inibidores da Angiogênese , Axitinibe , Células Endoteliais da Veia Umbilical Humana , Imidazóis , Indazóis , Indóis , Inibidores de Proteínas Quinases , Pirróis , Receptores de Fatores de Crescimento do Endotélio Vascular , Sunitinibe , Axitinibe/farmacologia , Humanos , Sunitinibe/farmacologia , Inibidores da Angiogênese/farmacologia , Imidazóis/farmacologia , Pirróis/farmacologia , Indóis/farmacologia , Receptores de Fatores de Crescimento do Endotélio Vascular/antagonistas & inibidores , Receptores de Fatores de Crescimento do Endotélio Vascular/metabolismo , Indazóis/farmacologia , Animais , Inibidores de Proteínas Quinases/farmacologia , Receptor TIE-2/metabolismo , Receptor TIE-2/antagonistas & inibidores , Neovascularização Patológica/tratamento farmacológico , Neovascularização Patológica/metabolismo
4.
5.
Clin Drug Investig ; 37(12): 1117-1124, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28940174

RESUMO

BACKGROUND AND OBJECTIVE: Extended-release (ER) opioids are associated with high rates of abuse. Recreational opioid users often manipulate ER formulations to achieve a high plasma concentration in a short amount of time, resulting in a more rapid and intense high. Patients may also manipulate ER tablets to facilitate swallowing, without recognizing that manipulation could increase release rate. The goal of this study was to assess the ability of oxycodone DETERx (Xtampza® ER, Collegium Pharmaceutical, Inc., Canton, MA, USA) and other commercially available ER opioid formulations with and without physicochemical abuse-deterrent characteristics to be manipulated by crushing in an in vitro setting. METHODS: In vitro dissolution techniques were used to compare the opioid release from a variety of ER opioid formulations. Dissolution was assessed for intact and crushed dosage forms. Opioid release was quantified using high-performance liquid chromatography. RESULTS: Intact formulations exhibited drug release rates characteristic of 12- or 24-h dosage forms. After crushing using commonly available household tools, only Xtampza ER maintained ER of opioid. CONCLUSIONS: Xtampza ER maintained its ER characteristics after crushing, unlike many other commercially available opioid formulations, including some formulated with abuse-deterrent properties. As such, Xtampza ER may be less appealing to abusers and offer a margin of safety for patients who manipulate dosage forms to facilitate swallowing.


Assuntos
Analgésicos Opioides/administração & dosagem , Liberação Controlada de Fármacos , Oxicodona/administração & dosagem , Administração Oral , Analgésicos Opioides/química , Cromatografia Líquida de Alta Pressão , Preparações de Ação Retardada/administração & dosagem , Humanos , Transtornos Relacionados ao Uso de Opioides , Oxicodona/química , Comprimidos
6.
Pain Pract ; 16(3): 334-44, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25639548

RESUMO

BACKGROUND: Patients who have chronic pain with dysphagia (difficulty swallowing) (CPD) often have difficulty taking oral medication and, as such, alter their medications by crushing or chewing in an attempt to make it easier to swallow. Such manipulation of currently marketed, extended-release (ER) opioid analgesics can significantly alter the pharmacokinetic (PK) properties of the formulations, resulting in poor treatment outcome or serious adverse events. There is an unmet medical need for oral ER opioid formulations suitable for patients with CPD. OBJECTIVE: The primary objectives of this study were to conduct in vitro studies to evaluate alternate means of administration of a new, extended-release (ER), abuse-deterrent, microsphere-in-capsule formulation of oxycodone for patients with CPD. Specifically, these studies investigated the in vitro equivalence of drug release rates from Oxycodone DETERx® ER intact capsules (control condition) and administration via alternate modes-opening the capsule and sprinkling the microspheres onto soft foods or administration through enteral tubes. Secondary objectives were to compare alternate modes of administration of Oxycodone DETERx® to a commercially available ER-morphine product. METHODS: Soft food study: Oxycodone DETERx® microspheres were sprinkled onto and mixed with several soft foods (ie, applesauce, vanilla pudding, strawberry jam, yogurt, and vanilla ice cream); the effect of drug contact time (0, 30, and 60 minutes) on drug release was studied. Enteral tube study: Oxycodone DETERx® microspheres were administered through varying sizes of nasogastric (10 and 12 Fr.) tubes and a 16 Fr. gastrostomy tube using 5 different delivery vehicles (ie, water, liquid nutritional feeds [Jevity®, Ensure®], and milk [whole milk and 2% milk]). Drug release rate was characterized using a standard in vitro dissolution methodology; dissolution of intact Oxycodone DETERx® capsules served as the control for both the soft food and enteral tube studies. Oxycodone concentration was measured using a standardized high-performance liquid chromatography (HPLC) assay. Similarity factor (f2) analysis was used to compare similarity of the dissolution profiles of test and control conditions. RESULTS: The mean dissolution profile of Oxycodone DETERx® microspheres sprinkled onto and mixed with each of the soft foods were similar (f2 > 50) to that of the control. Study drug-food contact time did not impact dissolution profiles. The dissolution data obtained from Oxycodone DETERx® microspheres passed through enteral feeding tubes of varying sizes were similar (f2 > 50) to that of the control. Unlike a marketed morphine sulfate ER pellet formulation, Oxycodone DETERx® did not clog any of the studied enteral tubes. CONCLUSION: A new ER, abuse-deterrent, microsphere-in-capsule formulation of oxycodone can be administered by sprinkling onto soft food without affecting the drug release profile of the formulation. The formulation can also be administered directly via enteral tubes without affecting drug release and without clogging enteral tubes. Oxycodone DETERx® may offer physicians and patients with CPD an alternate treatment option, especially in those patients who have dysphagia or an aversion to swallowing monolithic tablet/capsule formulations and for whom analgesic patches or other opioid formulations are not a viable therapeutic option.


Assuntos
Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/uso terapêutico , Dor Crônica/tratamento farmacológico , Transtornos de Deglutição/complicações , Oxicodona/administração & dosagem , Oxicodona/uso terapêutico , Manejo da Dor/métodos , Adulto , Analgésicos Opioides/farmacocinética , Cápsulas , Química Farmacêutica , Dor Crônica/complicações , Deglutição , Preparações de Ação Retardada , Alimentos , Humanos , Intubação Gastrointestinal , Microesferas , Transtornos Relacionados ao Uso de Opioides , Oxicodona/farmacocinética
7.
J Opioid Manag ; 10(4): 233-46, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25162603

RESUMO

OBJECTIVE: In vitro: To assess the effect of common crushing techniques on particle size reduction (PSR) and in vitro drug-release kinetics of oxycodone DETERx® (herein DETERx) and of a commercially available oxycodone extended-release (ER) tablet. In vivo: To evaluate the impact of the most effective manipulation method identified in the in vitro study and the effect of chewing on the pharmacokinetics (PK) of DETERx relative to oxycodone solution. DESIGN: In vitro: Mechanical manipulation of dosage forms using common household utensils. In vivo: Open-label, randomized, active-controlled, crossover PK study. SUBJECTS: In vivo: Forty-four healthy male and female volunteers. METHODS: In vitro: DETERx capsule contents and marketed comparator tablets were subjected to manipulation (crushing) using 10 different household utensils. Particle size and dissolution analysis were conducted. In vivo: Subjects were randomly assigned to receive DETERx 40-mg capsules intact, crushed, or chewed or oxycodone solution. Serial blood samples were drawn for PK assessment. RESULTS: In vitro: The utensils used to manipulate DETERx capsule contents were either ineffective in reducing the particle size or produced only a small change in the median particle size and dissolution rate relative to the marketed comparator. In vivo: DETERx intact capsules provided significantly lower Cmax and longer Tmax values than oxycodone solution. Manipulation of DETERx by crushing (using the most effective method established in vitro) or chewing resulted in bioequivalent plasma concentration-time profiles to the intact dosage form. CONCLUSION: These mechanical manipulation and PK studies demonstrated that DETERx beads retained their ER properties after mechanical tampering and chewing by study subjects.


Assuntos
Analgésicos Opioides/farmacocinética , Mastigação , Transtornos Relacionados ao Uso de Opioides/prevenção & controle , Oxicodona/farmacocinética , Administração Oral , Adolescente , Adulto , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/sangue , Analgésicos Opioides/química , Disponibilidade Biológica , Química Farmacêutica , Estudos Cross-Over , Preparações de Ação Retardada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oxicodona/administração & dosagem , Oxicodona/sangue , Oxicodona/química , Tamanho da Partícula , Solubilidade , Comprimidos , Adulto Jovem
8.
Drug Dev Ind Pharm ; 28(6): 641-54, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12149956

RESUMO

The quantity and consistency of drug delivery from dry powder inhalation devices that incorporate a pre-measured dose in a hard shell capsule of gelatin or other compatible material can be negatively affected by mold release lubricants used in capsule manufacturing. This paper describes a novel process employing supercritical CO2 for selective extraction of the fraction of lubricant responsible for the observed high and inconsistent drug retention in capsules and the ensuing lack of reproducibility of drug delivery. The process allows for lubricant removal from seemingly inaccessible interior surfaces of assembled capsule shells without altering the structural or chemical properties of the capsules. Diffusion limitations are overcome through repeated pressure increase and decrease to generate significant convective flow of dissolved lubricant out of the capsule. Drug retention is alleviated only if nearly all the retentive fraction of the lubricant is removed. The effect of extraction with supercritical CO2 on the structure of the internal surfaces of the capsules is investigated using scanning electron microscopy. Key performance parameters such as drug and carrier retention and fine particle mass are investigated using simulated inhalation tests. Laboratory and pilot scale extractions yielded similar results.


Assuntos
Dióxido de Carbono/química , Sistemas de Liberação de Medicamentos , Administração por Inalação , Cápsulas , Portadores de Fármacos , Gelatina , Humanos , Lubrificação , Tamanho da Partícula , Solubilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA