Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Int J Cardiol ; 360: 13-20, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35472561

RESUMO

BACKGROUND: incomplete strut coverage determines the risk of stent thrombosis in the first months after stent implantation. AIMS: To evaluate the potential better early healing of a novel probucol coated polymer free ultra-thin strut sirolimus eluting stent (PF-SES). [Clinical trial unique identifier: NCT02785237]. METHODS: Patients with two (angiographically similar) lesions with clinical indication for PCI were enrolled. The investigated stent was compared to a thin strut, bioresorbable polymer, sirolimus eluting stent (BP-SES). Every patient received both stents, one in each lesion, assigned in a randomized sequence. OCT was systematically performed at 3 months. Primary end point was the difference in the proportion of covered struts at 3 months (defined as ≥20 µm of tissue coverage). Secondary end points included differences in percentage of uncovered struts (0 µm coverage), mean strut coverage thickness, and malapposed struts' coverage proportion. Major adverse cardiac events (cardiac death, myocardial infarction, target lesion revascularization, and definite or probable stent thrombosis) at 12 months were also evaluated. RESULTS: 70 patients were included. At 3 months, a consistent and significantly higher strut coverage rate (≥20 µm) was observed in PF-SES as compared to BP-SES, both for well apposed (87.3% versus 79.1%, p < 0.001) and malapposed struts (50.4% vs 37.8%, p 0.00). Uncoverage rate (0 µm) was also significantly lower for the PF-SES (3.1% vs 5.3%, p < 0.001). There were no differences in clinical endpoints. CONCLUSION: The probucol coated non-polymeric ultra-thin strut sirolimus eluting stent showed a significantly better early strut coverage at 3 months.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Probucol , Desenho de Prótese , Sirolimo , Stents , Tomografia de Coerência Óptica , Resultado do Tratamento
3.
Am Heart J ; 165(1): 65-72, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23237135

RESUMO

BACKGROUND: No randomized studies have thus far evaluated intravascular ultrasound (IVUS) guidance in the drug-eluting stent (DES) era. The aim was to evaluate if IVUS optimized DES implantation was superior to angiographic guidance alone in complex lesions. METHODS: Randomized, multicentre, international, open label, investigator-driven study evaluating IVUS vs angiographically guided DES implantation in patients with complex lesions (defined as bifurcations, long lesions, chronic total occlusions or small vessels). Primary study endpoint was post-procedure in lesion minimal lumen diameter. Secondary end points were combined major adverse cardiac events (MACE), target lesion revascularization, target vessel revascularization, myocardial infarction (MI), and stent thrombosis at 1, 6, 9, 12, and 24 months. RESULTS: The study included 284 patients. No significant differences were observed in baseline characteristics. The primary study end point showed a statistically significant difference in favor of the IVUS group (2.70 mm ± 0.46 mm vs. 2.51 ± 0.46 mm; P = .0002). During hospitalization, no patient died, had repeated revascularization, or a Q-wave MI. No difference was observed in the occurrence of non-Q wave MI (6.3% in IVUS vs. 7.0% in angio-guided group). At 24-months clinical follow-up, no differences were still observed in cumulative MACE (16.9%vs. 23.2 %), cardiac death (0%vs. 1.4%), MI (7.0%vs. 8.5%), target lesion revascularization (9.2% vs. 11.9%) or target vessel revascularization (9.8% vs. 15.5%), respectively in the IVUS vs. angio-guided groups. In total, only one definite subacute stent thrombosis occurred in the IVUS group. CONCLUSIONS: A benefit of IVUS optimized DES implantation was observed in complex lesions in the post-procedure minimal lumen diameter. No statistically significant difference was found in MACE up to 24 months.


Assuntos
Implante de Prótese Vascular/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Stents Farmacológicos , Ultrassonografia de Intervenção/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Doença da Artéria Coronariana/mortalidade , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio , Estudos Prospectivos , Medição de Risco , Análise de Sobrevida , Trombose , Resultado do Tratamento
4.
EuroIntervention ; 6(8): 1003-10, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21330250

RESUMO

AIMS: Because of the reduction in the rate events related with in-stent restenosis, most events after drug-eluting stent implantation occur shortly after coronary stenting. Cobalt-chromium alloys allow to reduce strut thickness and improve flexibility and deliverability of coronary stent platforms, and thus could be associated with lower short-term events after stenting. The aim of this study was to test the hypothesis that drug-eluting coronary stents with a cobalt-chromium platform reduce the incidence of periprocedural (30-day) myocardial infarction in comparison with stainless steel drug-eluting coronary stents. METHODS AND RESULTS: A meta-analysis from nine randomised trials comparing cobalt-chromium and stainless steel drug-eluting coronary stents that overall included 11,313 patients was performed. The incidence of myocardial infarction, stent thrombosis, and cardiac death at 30 days was compared between both types of stents. At 30 days, the incidence of acute myocardial infarction was significantly lower in patients allocated to cobalt-chromium drug-eluting stents (2.3% vs. 3.9%, respectively; p=0.006; odds ratio 0.72, 95% confidence interval 0.58-0.91), due to a significant reduction in the rate of non-Q-wave myocardial infarction (odds ratio 0.67, 95% confidence interval 0.51-0.88). The incidence of stent thrombosis was similar between both groups of patients, (0.5% vs. 0.5%, p=0.76; odds ratio 1.09, 95% confidence interval 0.63-1.89). CONCLUSIONS: Drug-eluting coronary stents that use cobalt-chromium stent platforms have a better safety profile at 30 days in comparison with stainless steel drug-eluting stents, due to a significant reduction in the rate of myocardial infarction.


Assuntos
Angioplastia Coronária com Balão/estatística & dados numéricos , Ligas de Cromo , Stents Farmacológicos/estatística & dados numéricos , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/terapia , Aço Inoxidável , Humanos , Medição de Risco , Fatores de Risco
5.
Circulation ; 122(10): 1017-25, 2010 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-20733100

RESUMO

BACKGROUND: Predictors of antiplatelet therapy discontinuation (ATD) during the first year after drug-eluting stent implantation are poorly known. METHODS AND RESULTS: This was a prospective study with 3-, 6-, 9-, and 12-month follow-up of patients receiving at least 1 drug-eluting stent between January and April 2008 in 29 hospitals. Individual- and hospital-level predictors of ATD were assessed by hierarchical-multinomial regression analysis. ATD could be assessed in 1622 candidates for follow-up (82.5%). A total of 234 patients (14.4%) interrupted at least 1 antiplatelet therapy drug, predominantly clopidogrel (n=182, 11.8%). Bleeding events or invasive procedures led to ATD in 109 patients. This was predicted by renal impairment (odds ratio [OR] 2.81, 95% confidence interval [CI] 1.48 to 5.34), prior major hemorrhage (OR 3.77, 95% CI 1.41 to 10.03), and peripheral arterial disease (OR 1.78, 95% CI 1.01 to 3.15). Medical decisions led to ATD in 70 patients; this was predicted by long-term use of anticoagulant therapy (OR 3.88, 95% CI 1.26 to 11.98), undergoing the procedure in a private hospital (OR 13.3, 95% CI 1.69 to 105), and not receiving instructions about medication (OR 2.8, 95% CI 1.23 to 6.36). Thirty-nine patients interrupted ATD on their own initiative, mainly immigrants (OR 3.78, 95% CI 1.2 to 11.98) and consumers of psychotropic drugs (OR 2.58, 95% CI 1.3 to 5.12). CONCLUSIONS: ATD during the first year after drug-eluting stent implantation is based mainly on patient decision or a medical decision not associated with major bleeding events or major surgical procedures. Individual- and hospital-level variables are important to predict ATD.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Adesão à Medicação/estatística & dados numéricos , Trombose/prevenção & controle , Ticlopidina/análogos & derivados , Idoso , Clopidogrel , Doença da Artéria Coronariana/epidemiologia , Esquema de Medicação , Feminino , Seguimentos , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Readmissão do Paciente/estatística & dados numéricos , Doenças Vasculares Periféricas/epidemiologia , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Insuficiência Renal/epidemiologia , Automedicação/estatística & dados numéricos , Trombose/epidemiologia , Ticlopidina/administração & dosagem , Ticlopidina/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA