Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ophthalmol Ther ; 13(9): 2393-2404, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39028450

RESUMO

INTRODUCTION: This study aimed to analyze corneal sensitivity with a new noncontact and handheld esthesiometer (Brill Engines, Spain) in patients with dry eye disease (DED) and patients on hypotensive drops, and to compare it with healthy subjects. METHODS: A total of 31 patients (57 eyes) with DED, 23 patients (46 eyes) with glaucoma, and 21 healthy patients (33 eyes) were recruited. In all patients, corneal sensitivity was measured. Subsequently, a keratography test (Keratograph 5M, Oculus) was carried out to measure tear meniscus height (TMH), non-invasive breakup time (NIBUT), bulbar redness (Jenvis scale), and corneal staining (CS, Oxford scale). Both corneal sensitivity and ocular surface parameters were compared between DED, glaucoma, and healthy subjects. Linear mixed models were constructed to utilize data from both eyes of patients. An alpha level of 0.05 was considered statistically significant. RESULTS: The mean age was 56.1 ± 16.1 years in the DED group, 69.5 ± 11.7 years in the glaucoma group, and 37.190 ± 11.677 years in the control group. After adjustment for age and sex, corneal sensitivity was significantly reduced in DED and glaucoma vs control group (P = 0.02 and P = 0.009, respectively). NIBUT was lower in DED and glaucoma groups (P < 0.001 and P = 0.001, respectively). Redness and CS values were higher in the DED group (P = 0.04 and P = 0.001, respectively). TMH was lower in the glaucoma group (P = 0.03). CONCLUSIONS: Corneal sensitivity measured with a novel noncontact esthesiometer was reduced in DED and glaucoma groups compared to controls. In clinical practice, this esthesiometer could be an easy-to-use device to screen for patients with subclinical neurotrophic keratopathy.

2.
Res Sq ; 2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37292809

RESUMO

Objectives: To analyze corneal sensitivity with a new noncontact and hand-held esthesiometer (Brill Engines, Spain) in patients with dry eye disease (DED) and patients on hypotensive drops, and to compare it with healthy subjects. Methods: 31 patients (57 eyes) with DED, 23 patients (46 eyes) with glaucoma and 21 healthy patients (33 eyes) were recruited. In all patients, corneal sensitivity was measured. Subsequently, a keratography test (Keratograph 5M, Oculus) was carried out to measure tear meniscus height (TMH), non-invasive break up time (NIBUT), bulbar redness (Jenvis scale) and corneal staining (CS, Oxford scale). Both corneal sensitivity and ocular surface parameters were compared between DED, glaucoma, and healthy subjects. Linear mixed models were constructed to utilize data from both eyes of patients. A 95% confidence level was considered statistically significant. Results: The mean age was 56.1±16.1 years in DED group, 69.5±11.7 years in the glaucoma group and 36.3±10.5 years in the control group. Adjusting for age and sex, esthesiometry was significantly worse in DED and glaucoma vs control group (p = 0.02 and p = 0.009, respectively). NIBUT was lower in DED and glaucoma patients (p < 0.001 and p = 0.001, respectively). Redness and CS values were higher in DED group (p = 0.04 and p = 0.001, respectively). TMH was lower in the glaucoma patients (p = 0.03). Conclusions: Corneal sensitivity measured with a novel noncontact esthesiometer was reduced in DED and glaucoma patients compared to controls. In clinical practice, this esthesiometer could be an easy-to-use device to evaluate for patients with subclinical neurotrophic keratopathy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA