Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
PLoS One ; 19(5): e0303752, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753866

RESUMO

BACKGROUND: First metatarsophalangeal joint arthrodesis is a typical medical treatment performed in cases of arthritis or joint deformity. The gold standard for this procedure is arthrodesis stabilisation with the dorsally positioned plate. However, according to the authors' previous studies, medially positioned plate provides greater bending stiffness. It is worth to compare the mechanical conditions for bone formation in the fracture callus for both placements of the locking plate. METHODS: Two finite element models of the first metatarsophalangeal joint with the dorsally and medially positioned plate were defined in the Abaqus software to simulate differentiation of the fracture callus. A simplified load application, i.e. one single step per each day and the diffusion of the mesenchymal stem cells into the fracture region were assumed in an iterative hardening process. The changes of the mesenchymal stem cells into different phenotypes during the callus stiffening were governed by the octahedral shear strain and interstitial fluid velocity according to Prendergast mechanoregulation theory. Basing on the obtained results the progress of the cartilage and bone tissues formation and their distribution within the callus were compared between two models. FINDINGS: The obtained results suggest that after 6 weeks of simulation the healing progress is in general comparable for both plates. However, earlier closing of external callus was observed for the medially positioned plate which had greater vertical bending stiffness. This process enables faster internal callus hardening and promotes symmetrical bridging.


Assuntos
Artrodese , Placas Ósseas , Análise de Elementos Finitos , Articulação Metatarsofalângica , Artrodese/métodos , Humanos , Articulação Metatarsofalângica/cirurgia , Fenômenos Biomecânicos , Calo Ósseo , Consolidação da Fratura
2.
J Biomech ; 157: 111736, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37517283

RESUMO

Connective fibrous tissues, such as tendons and ligaments, in humans and animals exhibit hyperelastic behaviour. The constitution of the material of these tissues is anisotropic due to the presence of the collagen fibres, where one family of fibres is the typical case. Traumatic events and/or aging may sometimes lead to the damage of the tissue. The study of motion of affected joints or limbs is usually not permitted in vivo. This is where finite element method (FEM) becomes useful as a premise for general analysis, surgical planning or designing of implants and medical treatment. One of the most often used FEM commercial programs is the field of the biomechanics is Abaqus. The present study discusses the potential of user subroutine UANISOHYPER_INV in this code to analyse response of transversely isotropic tissue with damage in quasi-static range. This subroutine requires providing the material energy function and its derivatives only. The stress tensor and constitutive matrix are computed by the software automatically. To the best of the Authors' knowledge this procedure provides the easiest way to simulate the anisotropic hyperelastic material behaviour in Abaqus. In this study its usage is extended onto the damage response simulation. The verification of the approach and its validation against experimental data indicates its efficiency.


Assuntos
Ligamentos , Software , Animais , Humanos , Elasticidade , Análise de Elementos Finitos , Estresse Mecânico , Simulação por Computador , Ligamentos/fisiologia , Modelos Biológicos
3.
PLoS One ; 16(5): e0250397, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33945554

RESUMO

BACKGROUND: Soft tissue tension is treated as a crucial factor influencing the post-THA dislocation. The femoral offset is regarded as one of the major parameters responsible for the stabilization of the prosthesis. It is unclear which soft tissue is mostly affected by the offset changes. METHODS: A finite element model of the hip was created. The model comprised muscles, bones, a stem, the acetabular component and a liner. The muscles were modelled as a Hill-type musculo-tendon nonlinear springs. Nonlinear analyses of the hip flexion and internal rotation were performed for the two values of the femoral stem offset. RESULTS: We observed that the quadratus femoris and gluteus medius produce the largest resisting moment opposing the external load excreted by the surgeon during the intraoperative hip dislocation test. CONCLUSIONS: An increased femoral offset increases the stretching of the quadratus femoris muscle significantly and provides the growth of its initial passive force. This muscle serves as a stiff band, providing stabilisation of the hip prosthesis, measured during the simulated intraoperative test.


Assuntos
Artroplastia de Quadril/métodos , Simulação por Computador , Fêmur/fisiologia , Músculo Esquelético/fisiologia , Falha de Prótese/etiologia , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Fêmur/cirurgia , Análise de Elementos Finitos , Quadril/fisiologia , Quadril/cirurgia , Humanos , Músculo Esquelético/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA