Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Clin Imaging ; 110: 110142, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38696997

RESUMO

PURPOSE: The purpose of this study was to evaluate long-term morphologic changes occurring in the liver after TIPS creation with correlation with hepatic function to gain insight on the physiologic impact of TIPS on the liver. METHODS: This retrospective study included patients who underwent TIPS creation between 2005 and 2022 and had contrasted CT or MRI studies prior to and between 1 and 2 years post procedure. Strict exclusion criteria were applied to avoid confounding. Parenchymal volume and vessel measurements were assessed on the pre- and post-TIPS CT or MRI and MELD scores calculated. RESULTS: Of 580 patients undergoing TIPS creation, 65 patients (mean age, 55 years; 36 males) had pre-TIPS and post-TIPS imaging meeting inclusion criteria at median 16.5 months. After TIPS, the mean MELD score increased (12.9 to 15.4; p = 0.008) and total liver volume decreased (1730 to 1432 mL; p < 0.001). However, the magnitude of volume change did not correlate with MELD change. Neither portosystemic gradient nor TIPS laterality correlated with total or lobar hepatic volume changes or MELD changes. The main portal vein diameter increased (15.0 to 18.7 mm; p < 0.001). Thrombosis of the hepatic vein used for TIPS creation resulted in a mean increase in MELD of +4.1 compared to -2.1 in patients who had a patent and normal hepatic vein (p = 0.007). CONCLUSIONS: Given lack of correlation between portosystemic gradient, hepatic atrophy, hepatic function, and TIPS laterality, the alterations in portal flow dynamics after TIPS may not be impactful to hepatic function. However, hepatic vein patency after TIPS correlated with improved hepatic function.


Assuntos
Fígado , Imageamento por Ressonância Magnética , Derivação Portossistêmica Transjugular Intra-Hepática , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Resultado do Tratamento
2.
Artigo em Inglês | MEDLINE | ID: mdl-38335943

RESUMO

OBJECTIVE: Cement volumes are increasingly linked to orthopedic oncology and neurosurgical outcomes (construct durability, adjacent fracture), but manual cement volumetry remains time prohibitive. The authors aim to report performance of PACS-integrated volumetric software specifically for barium-enhanced polymethylmethacrylate cement. METHODS: Institutional review board-approved single-institution retrospective review of patients from 2019-2022 undergoing kyphoplasty for pathological compression fractures with a quantitative cement infuser providing true cement volume. An operator blinded to true cement volumes retrospectively performed software-assisted volumetry on follow-up computed tomography scans. RESULTS: Included were 91 kyphoplasty levels in 56 patients: mean age, 62 years (range, 34-85 years), 73% female. True cement volume (available for 44 of 66 procedures) was mean 4.5 mL per level (range, 1.2-15.6 mL). Measured cement volume (available for all procedures) yielded a mean of 6.1 mL per level (range, 1.5-27.9 mL). For the 57 levels (39 patients) where both true and measured cement volumes were available, linear regression intercept and slope were 1.46 (95% CI = 0.97-1.95, P < 0.001) and 0.52 (CI = 0.47-0.57, P < 0.001), respectively, suggesting measured volume averaged 1.46 mL greater than true volume, with each additional milliliter of measured volume corresponding to approximately 0.52 mL of true volume. There was no significant difference in the relationship between estimated and actual cement volume in thoracic levels (intercept = -0.24, CI = -1.13 to 0.66, P = 0.61; slope = 0.03, CI = -0.14 to 0.19, P = 0.73) compared with lumbar levels. The goodness-of-fit of the regression model was strong (R2 = 0.81). Discrepancies ranged from 90% underestimation to 52% overestimation; average, 17% overestimation. CONCLUSIONS: Semi-automated volumetry maintained a strong correlation with true volumes across the thoracic and lumbar curvatures, overestimating cement volume by a mean of 17% or 1.46 mL.

5.
J Vasc Interv Radiol ; 33(12): 1594-1600, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36007783

RESUMO

PURPOSE: To measure the ablation zone temperature and nontarget tissue temperature during radiofrequency (RF) ablation in bone containing metal instrumentation versus no metal instrumentation (control group). MATERIALS AND METHODS: Ex vivo experiments were performed on 15 swine vertebrae (control, n = 5; titanium screw, n = 5; stainless steel screw, n = 5). Screws and RF ablation probe were inserted identically under fluoroscopy. During RF ablation (3 W, 5 minutes), temperature was measured 10 mm from RF ablation centerpoint and in muscle contacting the screw. Magnetic resonance (MR) imaging, gross pathologic, and histopathologic analyses were performed on 1 specimen from each group. RESULTS: Ablation zone temperatures at 2.5 and 5 minutes increased by 12.2 °C ± 2.6 °C and 21.5 °C ± 2.1 °C (control); 11.0 °C ± 4.1 °C and 20.0 °C ± 2.9 °C (juxta-titanium screw), and 10.0 °C ± 3.4 °C and 17.2 °C ± 3.5 °C (juxta-stainless steel) screw; differences among groups did not reach significance by analysis of variance (P = .87). Mixed-effects linear regression revealed a statistically significant increase in temperature over time in all 3 groups (4.2 °C/min ± 0.4 °C/min, P < .001). Compared with the control, there was no significant difference in the temperature change over time for titanium (-0.3 °C/min ± 0.5 °C/min, P = .53) or steel groups (-0.4 °C/min ± 0.5 °C/min, P = .38). The mean screw temperature at the final time point did not show a statistically significant change compared with baseline in either the titanium group (-1.2 °C ± 2.3 °C, P = .50) or steel group (2.6 °C ± 2.9 °C, P = .11). MR imaging and pathologic analyses revealed homogeneous ablation without sparing of the peri-hardware zones. CONCLUSIONS: Adjacent metallic instrumentation did not affect the rate of or absolute increase in temperature in the ablation zone, did not create peri-metallic ablation inhomogeneities, and did not result in significant nontarget heating of muscle tissue in contact with the metal instrumentation.


Assuntos
Ablação por Cateter , Aço Inoxidável , Suínos , Animais , Titânio , Ablação por Cateter/métodos , Fígado/cirurgia , Imageamento por Ressonância Magnética
6.
Tech Vasc Interv Radiol ; 25(2): 100823, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35551806

RESUMO

Autonomously functioning thyroid nodules (AFTN) are a common cause of hyperthyroid symptoms. While hemithyroidectomy or radioactive iodine ablation have historically been used to treat AFTNs, percutaneous thyroid radiofrequency ablation (RFA) is emerging as a promising option for outpatient therapy. The technique is compared to medical therapy, radioactive iodine therapy, and surgery, with an emphasis on technical differences in the ablation procedure for AFTN vs other benign thyroid nodules.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Ablação por Cateter/efeitos adversos , Humanos , Radioisótopos do Iodo , Ablação por Radiofrequência/efeitos adversos , Neoplasias da Glândula Tireoide/cirurgia , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/cirurgia , Resultado do Tratamento
7.
Tech Vasc Interv Radiol ; 25(1): 100798, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35248325

RESUMO

Oncology patients, particularly those with breast, colorectal, prostate, renal and pancreatic cancers, are living longer due to advances in detection, and treatment. Unfortunately, this has come with a commensurate increase in the prevalence of osseous metastases and skeletal related events approaching 100,000 new patients each year. Patients are now experiencing serious morbidity and mortality due to pathologic fractures, altered structural mechanics, and cancer related bone pain. This patient population poses challenges for conventional open surgical and/or medical management often due to disease extent, location, and, in general, poor surgical candidacy. Percutaneous techniques may also be challenging under image guidance due to limited ability to use traditional orthopedic corridors, loss of cortical landmarks with destructive lesions, and need for live image guidance. Modern angiography suites with cone beam computed tomography (CBCT) and advanced imaging applications including needle guidance, 3D fusion, tumor segmentation, and angio-CT have facilitated the development of novel minimally invasive techniques for pain palliation and stabilization. The interventional radiologist is uniquely positioned to harness these advanced imaging applications and offer effective, safe, minimally invasive treatment options to patients with neoplastic disease within the axial, and appendicular skeletons. The focus of this article is to address the technical aspects of patient preparation, positioning, advanced imaging system capabilities, guidance strategies, and pitfalls during osteoplasty and fixation procedures.


Assuntos
Neoplasias Ósseas , Neoplasias/patologia , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Manejo da Dor , Resultado do Tratamento
8.
Clin Imaging ; 85: 14-21, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35228170

RESUMO

PURPOSE: To evaluate patient outcomes after sacroplasty (percutaneous sacral augmentation) with guidance using CT compared to fluoroscopy with augmented reality overlay using fluoroscopic cone-beam CT and FDA-approved software (CBCT-AF). MATERIALS AND METHODS: Retrospective IRB-approved study of all patients undergoing sacroplasty between 3/2019-9/2020 was performed. Procedural details were collected including whether the procedure was performed with CT-fluoroscopic guidance versus cone beam CT with vector navigation and real-time neuroforaminal contour overlay. Clinical details collected included Visual Analogue Scale (VAS) pain scores within 6-months post intervention. Images were analyzed on PACS to measure exact volumes of implanted cement. RESULTS: Twelve patients underwent sacroplasty using either CT (n = 13 hemisacra) or CBCT-AF (n = 10 hemisacra). No clinically significant complications occurred. Comparing CT versus CBCT-AF guidance there was no significant difference in radiation dose (CBCT-AF trended toward lower dose, p = 0.20), total anesthesia time (p = 0.71), or infused cement volume (p = 0.21). VAS pain scores decreased an average of 6.14 and 5.25 points for the CT and CBCT-AF groups respectively (p = 0.46, no significant difference between groups). CONCLUSION: Sacroplasty improved back pain in all patients, while CBCT-AF safely provided similar outcomes with trends toward lower radiation dose and cement volume compared to CT-fluoroscopy.


Assuntos
Realidade Aumentada , Fraturas da Coluna Vertebral , Vertebroplastia , Tomografia Computadorizada de Feixe Cônico/métodos , Fluoroscopia/métodos , Humanos , Estudos Retrospectivos , Sacro , Resultado do Tratamento , Vertebroplastia/efeitos adversos , Vertebroplastia/métodos
9.
Eur J Clin Invest ; 52(5): e13765, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35267195

RESUMO

INTRODUCTION: Chronic kidney disease (CKD) which is a common cause of death has an increasing trend, but there is no established approach for predicting CKD progression yet. Functional magnetic resonance imaging (fMRI) studies such as blood oxygenation level-dependent MRI (BOLD-MRI), diffusion-weighted MRI (DWI-MRI), diffusion-tensor MRI (DTI-MRI) and arterial spin labelling MRI (ASL-MRI) are rising methods for the assessment of kidney functions in native and transplanted kidneys as well as the estimation of CKD progression. METHODS: Systematic literature review was performed through the Embase (Elsevier), Cochrane Central Register of Controlled Trials (Wiley), PubMed/Medline and Web of Science databases, and studies investigating the role of fMRI methods assessing kidney functions in native and transplanted kidneys, as well as the value of fMRI methods to predict CKD progression, were included. Working mechanisms, advantages and limitations of the fMRI modalities were reviewed, and three studies investigating the role of fMRI studies in kidney functions were analysed. RESULTS AND CONCLUSION: BOLD-MRI signal was found to be inversely correlated with annual eGFR change, and DWI/ADC (apparent diffusion coefficient map) values were shown to be correlated with annual eGFR decline. fMRI methods which are currently used for other systems can be utilized to provide more detailed information about kidney functions, and doctors should be ready to interpret kidney MRIs.


Assuntos
Rim , Insuficiência Renal Crônica , Progressão da Doença , Taxa de Filtração Glomerular , Humanos , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Insuficiência Renal Crônica/diagnóstico por imagem
10.
Eur J Clin Invest ; 52(6): e13748, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35040119

RESUMO

BACKGROUND: Metabolic syndrome is a growing twenty-first century pandemic associated with multiple clinical comorbidities ranging from cardiovascular diseases, non-alcoholic fatty liver disease and polycystic ovary syndrome to kidney dysfunction. A novel area of research investigates the concept of fatty kidney in the pathogenesis of chronic kidney disease, especially in patients with diabetes mellitus or metabolic syndrome. AIM: To review the most updated literature on fatty kidney and provide future research, diagnostic and therapeutic perspectives on a disease increasingly affecting the contemporary world. MATERIALS AND METHOD: We performed an extensive literature search through three databases including Embase (Elsevier) and the Cochrane Central Register of Controlled Trials (Wiley) and PubMed/Medline Web of Science in November 2021 by using the following terms and their combinations: 'fatty kidney', 'ectopic fat', 'chronic kidney disease', 'cardiovascular event', 'cardio-metabolic risk', 'albuminuria' and 'metabolic syndrome'. Each study has been individually assessed by the authors. RESULTS: Oxidative stress and inflammation, Klotho deficiency, endoplasmic reticulum stress, mitochondrial dysfunction and disruption of cellular energy balance appear to be the main pathophysiological mechanisms leading to tissue damage following fat accumulation. Despite the lack of large-scale comprehensive studies in this novel field of research, current clinical trials demonstrate fatty kidney as an independent risk factor for the development of chronic kidney disease and cardiovascular events. CONCLUSION: The requirement for future studies investigating the pathophysiology, clinical outcomes and therapeutics of fatty kidney is clear.


Assuntos
Síndrome Metabólica , Hepatopatia Gordurosa não Alcoólica , Insuficiência Renal Crônica , Albuminúria , Feminino , Humanos , Rim , Síndrome Metabólica/complicações , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Hepatopatia Gordurosa não Alcoólica/terapia , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/etiologia
11.
J Vasc Interv Radiol ; 33(3): 286-294, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34798292

RESUMO

PURPOSE: To assess ischemic adverse events following particle embolization when used as a second-line embolic to coil embolization for the treatment of acute lower gastrointestinal bleeding (LGIB). MATERIALS AND METHODS: The single-institution retrospective study examined 154 procedures where embolization was attempted for LGIB. In 122 patients (64 men; mean age, 69.9 years), embolization was successfully performed using microcoils in 73 procedures, particles in 34 procedures, and both microcoils and particles in 27 procedures. Particles were used as second-line only when coil embolization was infeasible or inadequate. Technical success was defined as angiographic cessation of active extravasation after embolization. Clinical success was defined as the absence of recurrent bleeding within 30 days of embolization. RESULTS: Technical success for embolization of LGIB was achieved in 87% of the cases (134/154); clinical success rate was 76.1% (102/134) among the technically successful cases. Clinical success was 82.2% (60/73) for coils alone and 68.9% (42/61) for particles with or without coils. Severe adverse events involving embolization-induced bowel ischemia occurred in 3 of 56 (5.3%) patients who underwent particle embolization with or without coils versus zero of 66 patients when coils alone were used (P = .09). In patients who had colonoscopy or bowel resection within 2 weeks of embolization, ischemic findings attributable to the procedure were found in 3 of the 15 who underwent embolization with coils alone versus 8 of 18 who underwent embolization with particles with or without coils (P = .27). CONCLUSIONS: Particle embolization for the treatment of LGIB as second-line to coil embolization was associated with a 68.9% clinical success rate and a 5.3% rate of ischemia-related adverse events.


Assuntos
Embolização Terapêutica , Hemorragia Gastrointestinal , Idoso , Angiografia , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
12.
Clin Kidney J ; 14(3): 756-767, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34512957

RESUMO

Despite massive government and private sector investments into prevention of cardiovascular disease, diabetes mellitus and obesity, efforts have largely failed, and the burden of cost remains in the treatment of downstream morbidity and mortality, with overall stagnating outcomes. A new paradigm shift in the approach to these patients may explain why existing treatment strategies fail, and offer new treatment targets. This review aims to provide a clinician-centred primer on metabolic memory, defined as the sum of irreversible genetic, epigenetic, cellular and tissue-level alterations that occur with long-time exposure to metabolic derangements.

13.
Diagn Interv Radiol ; 27(5): 639-643, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34318752

RESUMO

PURPOSE: There is increasing interest in the distal radial artery in the anatomic snuffbox as an alternative arterial access point, but the durability of the distal radial artery to support repetitive accesses over multiple procedures is not well established. The purpose of this study was therefore to evaluate success rates for repeated left-sided distal transradial access (ldTRA) in the anatomic snuffbox. METHODS: In this single institution retrospective study, all patients undergoing radioembolization treatments from January 1st, 2019 to May 1st, 2020 were prospectively evaluated for ldTRA. ldTRA was performed by 15 different operators. Exclusion criteria were a left radiocephalic hemodialysis fistula, inability to properly position the arm, Barbeau D waveform, or failed prior ldTRA due to tortuosity. Barbeau patterns, arterial sizes, and success rates at the first, second, and third ldTRA were compared. RESULTS: Fifty patients were evaluated for ldTRA and 44, 39, and 10 underwent one, two, and three ldTRA attempts for a total of 93 procedures. There was no significant change in Barbeau patterns between the first and second (p = 0.13) or first and third (p = 1.0) ldTRA. There was no significant change in artery size between the first (mean, 2.3 mm; range, 1.5-3.4 mm) and second (mean, 2.3 mm; range, 1.6-3.3 mm) (p = 0.59) and first and third (mean, 2.4 mm; range, 1.9-3.3) (p = 0.45) ldTRA. The success rate was not significantly different between the first (93%, 41/44, 95% CI 81%-99%), second (95%, 37/39, 95% CI 83%-99%), and third (100%, 10/10, 95% CI 69%-100%) procedure (p = 1.0). The asymptomatic occlusion rate was 4.1% (2/49, 95% CI 0%-14%), and subsequent ldTRA was successfully completed in both patients with occlusions. There were no hemorrhagic or ischemic complications. CONCLUSION: Success rates are indistinguishable among first, second, and third time ldTRA suggesting that this is a durable access point.


Assuntos
Artéria Radial , Punho , Hemorragia , Humanos , Artéria Radial/diagnóstico por imagem , Diálise Renal , Estudos Retrospectivos
14.
J Vasc Interv Radiol ; 32(9): 1310-1318.e2, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34058351

RESUMO

PURPOSE: To report initial clinical experience with intravascular ultrasound (US)-guided transvenous biopsy (TVB) for perivascular target lesions in the abdomen and pelvis using side-viewing phased-array intracardiac echocardiography catheters. MATERIALS AND METHODS: In this single-institution, retrospective study, 48 patients underwent 50 intravascular US-guided TVB procedures for targets close to the inferior vena cava or iliac veins deemed difficult to access by conventional percutaneous needle biopsy (PNB). In all procedures, side-viewing phased-array intracardiac echocardiography intravascular US catheters and transjugular liver biopsy sets were inserted through separate jugular or femoral vein access sheaths, and 18-gauge core needle biopsy specimens were obtained under real-time intravascular US guidance. Diagnostic yield, diagnostic accuracy, and complications were analyzed. RESULTS: Intravascular US-guided TVB was diagnostic of malignancy in 40 of 50 procedures for a diagnostic yield of 80%. There were 5 procedures in which biopsy was correctly negative for malignancy, with a per-procedure diagnostic accuracy of 90% (45/50). Among the 5 false negatives, 2 patients underwent repeat intravascular US-guided TVB, which was diagnostic of malignancy for a per-patient diagnostic accuracy of 94% (45/48). There were 1 (2%) mild, 2 (4%) moderate, and 1 (2%) severe adverse events, with 1 moderate severity adverse event (venous thrombosis) directly attributable to the intravascular US-guided TVB technique. CONCLUSIONS: Intravascular US-guided TVB performed on difficult-to-approach perivascular targets in the abdomen and pelvis resulted in a high diagnostic accuracy, similar to accepted thresholds for PNB. Complication rates may be slightly higher but should be weighed relative to the risks of difficult PNB, surgical biopsy, or clinical management without biopsy.


Assuntos
Biópsia Guiada por Imagem , Pelve , Abdome , Biópsia com Agulha de Grande Calibre/efeitos adversos , Humanos , Estudos Retrospectivos , Ultrassonografia de Intervenção
15.
Clin Imaging ; 77: 187-192, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33940357

RESUMO

PURPOSE: Proton pump inhibitor (PPI) use is a potential risk factor for hepatic encephalopathy (HE), but few studies have examined the effect on post-TIPS HE. The purpose of this study was to determine whether PPIs are associated with increased rates of post-TIPS HE in an independent patient cohort. MATERIALS AND METHODS: This single-institution retrospective study analyzed 86 patients (54 male, mean age 58.2) following TIPS from 1/1/2017 to 12/31/2019. Dates of PPI usage and episodes of new or worsening HE were recorded. Poisson regression with generalized estimating equations was used to test for association between PPI use and post-TIPS HE and to test for dose dependence. Post-TIPS HE was also analyzed using the Andersen-Gill survival model for recurrent events. RESULTS: There were 1.88 episodes of new or worsening post-TIPS HE per person-year among 35 patients on uninterrupted PPIs therapy, 1.95 on PPIs and 0.94 off PPIs among 35 patients on intermittent therapy, and 0.47 among 16 patients never on PPIs. PPI use was significantly associated with post-TIPS HE in both univariable (incidence rate ratio (IRR) = 2.62; CI = 1.41-4.84; p = 0.002) and multivariable (IRR = 2.31; CI = 1.37-3.89; p = 0.002) regression. Analysis of only those patients on PPIs showed increased rates of HE with higher doses (IRR = 1.17 per 10 mg omeprazole equivalent; CI = 1.04-1.33; p = 0.011). Recurrent events survival analysis supported the association between PPI use and HE in univariable (hazard ratio (HR) = 2.17; CI = 1.19-3.95; p = 0.011) and multivariable (HR = 1.87; CI = 1.12-3.13; p = 0.017) analysis. CONCLUSION: In an independent patient cohort PPI use was associated with increased rates of new or worsening post-TIPS HE.


Assuntos
Encefalopatia Hepática , Derivação Portossistêmica Transjugular Intra-Hepática , Encefalopatia Hepática/induzido quimicamente , Encefalopatia Hepática/epidemiologia , Humanos , Cirrose Hepática , Masculino , Pessoa de Meia-Idade , Inibidores da Bomba de Prótons/efeitos adversos , Estudos Retrospectivos , Fatores de Risco
16.
PLoS One ; 16(1): e0234535, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33507942

RESUMO

Focal tumor ablation with ethanol could provide benefits in low-resource settings because of its low overall cost, minimal imaging technology requirements, and acceptable clinical outcomes. Unfortunately, ethanol ablation is not commonly utilized because of a lack of predictability of the ablation zone, caused by inefficient retention of ethanol at the injection site. To create a predictable zone of ablation, we have developed a polymer-assisted ablation method using ethyl cellulose (EC) mixed with ethanol. EC is ethanol-soluble and water-insoluble, allowing for EC-ethanol to be injected as a liquid and precipitate into a solid, occluding the leakage of ethanol upon contact with tissue. The aims of this study were to compare the 1) safety, 2) release kinetics, 3) spatial distribution, 4) necrotic volume, and 5) overall survival of EC-ethanol to conventional ethanol ablation in a murine breast tumor model. Non-target tissue damage was monitored through localized adverse events recording, ethanol release kinetics with Raman spectroscopy, injectate distribution with in vivo imaging, target-tissue necrosis with NADH-diaphorase staining, and overall survival by proxy of tumor growth. EC-ethanol exhibited decreased localized adverse events, a slowing of the release rate of ethanol, more compact injection zones, 5-fold increase in target-tissue necrosis, and longer overall survival rates compared to the same volume of pure ethanol. A single 150 µL dose of 6% EC-ethanol achieved a similar survival probability rates to six daily 50 µL doses of pure ethanol used to simulate a slow-release of ethanol over 6 days. Taken together, these results demonstrate that EC-ethanol is safer and more effective than ethanol alone for ablating tumors.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Depressores do Sistema Nervoso Central/administração & dosagem , Etanol/administração & dosagem , Animais , Apoptose , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Proliferação de Células , Feminino , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Células Tumorais Cultivadas , Ensaios Antitumorais Modelo de Xenoenxerto
17.
Int Urol Nephrol ; 53(9): 1839-1849, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33392884

RESUMO

Diuretic volume reduction continues to be the mainstay of congestive heart failure (CHF) management globally. However, diuretic resistance is a critical topic that lacks standardized evidence-based management guidelines accounting for mechanisms of diuretic resistance, renal function, and co-morbidities. Major healthcare utilization consequences result from this. The authors herein reconcile the definition of renal functional decline with emphasis on biomarker-driven assessment. Novel goal-directed treatment approaches are reviewed including hypertonic saline, acetazolamide, sodium-glucose transporter inhibition, sequential nephron blockade and Elabela-APJ axis targeting are reviewed, as well as percutaneous visceral splanchnic sympathectomy (converting a volume-focused to a distribution-focused paradigm).


Assuntos
Diuréticos/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Resistência a Medicamentos , Insuficiência Cardíaca/terapia , Humanos
18.
Cardiovasc Intervent Radiol ; 44(5): 784-788, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33388871

RESUMO

PURPOSE: To evaluate the technical success and safety of a steerable coaxial sharp recanalization technique that utilizes routine needles in patients with refractory thoracic central venous occlusions. MATERIALS AND METHODS: This retrospective study was performed on 36-attempted sharp recanalizations in 35 patients (mean age 50 years, 23 male) performed via a supraclavicular approach. In all cases, an 18-gauge trocar needle was custom curved to provide directional control during fluoroscopic triangulation. A 22-gauge Chiba needle was then advanced coaxially across the occlusion. A tractogram was performed to assess for traversal of unintended structures. Procedures were completed by catheter placement, angioplasty, or stenting follow successful recanalizations. RESULTS: Sharp recanalization using this steerable coaxial needle technique demonstrated a technical success rate of 94% (34/36). The mean occlusion length was 30 mm (range 3-53 mm). In 11 patients, success was achieved using this technique after failure of other advanced techniques. In five procedures, stent interstices were traversed. Sharp recanalization was the direct cause of one major complication consisting of pleural transgression causing mild hemothorax treated successfully with a stent graft. CONCLUSION: The proposed technique is effective and safe for patients who have failed traditional blunt recanalization techniques. LEVEL OF EVIDENCE: Level 4, Case Series.


Assuntos
Angioplastia/métodos , Stents , Tórax/irrigação sanguínea , Doenças Vasculares/cirurgia , Adulto , Idoso , Cateterismo Venoso Central , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
19.
J Nephrol ; 34(3): 649-659, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32440840

RESUMO

The most common cause of liver disease worldwide is now non-alcoholic fatty liver disease (NAFLD). NAFLD refers to a spectrum of disease ranging from steatosis to non-alcoholic steatohepatitis, causing cirrhosis, and ultimately hepatocellular carcinoma. However, the impact of NAFLD is not limited to the liver. NAFLD has extra-hepatic consequences, most notably, cardiovascular and renal disease. NAFLD and chronic kidney disease share pathogenic mechanisms including insulin resistance, lipotoxicity, inflammation and oxidative stress. Not surprisingly, there has been a recent surge in efforts to manage NAFLD in an integrated way that not only protects the liver but also delays comorbidities such as chronic kidney disease. This concept of simultaneously addressing the main disease target and comorbidities is key to improve outcomes, as recently demonstrated by clinical trials of SGLT2 inhibitors and GLP1 receptor agonists in diabetes. HIF activators, already marketed in China, also have the potential to protect both liver and kidney, as suggested by preclinical data. This review concisely discusses efforts at identifying common pathogenic pathways between NAFLD and chronic kidney disease with an emphasis on potential paradigm shifts in diagnostic workup and therapeutic management.


Assuntos
Resistência à Insulina , Hepatopatia Gordurosa não Alcoólica , Insuficiência Renal Crônica , Inibidores do Transportador 2 de Sódio-Glicose , China , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Hepatopatia Gordurosa não Alcoólica/tratamento farmacológico , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Insuficiência Renal Crônica/terapia
20.
Br J Nutr ; 125(11): 1201-1214, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-32921320

RESUMO

Energy restriction (ER) has anti-ageing effects and probably protects from a range of chronic diseases including cancer, diabetes and chronic kidney disease (CKD). Specifically, ER has a positive impact on experimental kidney ageing, CKD (diabetic nephropathy, polycystic kidney disease) and acute kidney injury (nephrotoxic, ischaemia-reperfusion injury) through such mechanisms as increased autophagy, mitochondrial biogenesis and DNA repair, and decreased inflammation and oxidative stress. Key molecules contributing to ER-mediated kidney protection include adenosine monophosphate-activated protein kinase, sirtuin-1 and PPAR-γ coactivator 1α. However, CKD is a complex condition, and ER may potentially worsen CKD complications such as protein-energy wasting, bone-mineral disorders and impaired wound healing. ER mimetics are drugs, such as metformin and Na-glucose co-transporter-2 which mimic the action of ER. This review aims to provide comprehensive data regarding the effect of ER on CKD progression and outcomes.


Assuntos
Restrição Calórica , Ingestão de Energia/fisiologia , Insuficiência Renal Crônica/dietoterapia , Adenosina Quinase/metabolismo , Animais , Reparo do DNA/fisiologia , Progressão da Doença , Humanos , Rim , Biogênese de Organelas , Estresse Oxidativo/fisiologia , Coativador 1-alfa do Receptor gama Ativado por Proliferador de Peroxissomo/metabolismo , Fatores de Proteção , Insuficiência Renal Crônica/metabolismo , Sirtuína 1/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA