Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38729387

RESUMO

BACKGROUND & AIMS: Large language models including Chat Generative Pretrained Transformers version 4 (ChatGPT4) improve access to artificial intelligence, but their impact on the clinical practice of gastroenterology is undefined. This study compared the accuracy, concordance, and reliability of ChatGPT4 colonoscopy recommendations for colorectal cancer rescreening and surveillance with contemporary guidelines and real-world gastroenterology practice. METHODS: History of present illness, colonoscopy data, and pathology reports from patients undergoing procedures at 2 large academic centers were entered into ChatGPT4 and it was queried for the next recommended colonoscopy follow-up interval. Using the McNemar test and inter-rater reliability, we compared the recommendations made by ChatGPT4 with the actual surveillance interval provided in the endoscopist's procedure report (gastroenterology practice) and the appropriate US Multisociety Task Force (USMSTF) guidance. The latter was generated for each case by an expert panel using the clinical information and guideline documents as reference. RESULTS: Text input of de-identified data into ChatGPT4 from 505 consecutive patients undergoing colonoscopy between January 1 and April 30, 2023, elicited a successful follow-up recommendation in 99.2% of the queries. ChatGPT4 recommendations were in closer agreement with the USMSTF Panel (85.7%) than gastroenterology practice recommendations with the USMSTF Panel (75.4%) (P < .001). Of the 14.3% discordant recommendations between ChatGPT4 and the USMSTF Panel, recommendations were for later screening in 26 (5.1%) and for earlier screening in 44 (8.7%) cases. The inter-rater reliability was good for ChatGPT4 vs USMSTF Panel (Fleiss κ, 0.786; 95% CI, 0.734-0.838; P < .001). CONCLUSIONS: Initial real-world results suggest that ChatGPT4 can define routine colonoscopy screening intervals accurately based on verbatim input of clinical data. Large language models have potential for clinical applications, but further training is needed for broad use.

2.
J Clin Gastroenterol ; 58(5): 487-493, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37339277

RESUMO

GOALS: This study aims to investigate associated mortality with inpatient endoscopic retrograde cholangiopancreatography (ERCP) with and without resistant infections. The co-primary objective compares frequencies of inpatient ERCP with resistant infections to overall hospitalizations with resistant infections. BACKGROUND: The risks of inpatient antibiotic-resistant organisms are known, but the associated mortality for inpatient ERCP is unknown. We aim to use a national database of hospitalizations and procedures to understand trends and mortality for patients with antibiotic-resistant infections during inpatient ERCP. STUDY: The largest publicly available all-payer inpatient database in the United States (National Inpatient Sample) was used to identify hospitalizations associated with ERCPs and antibiotic-resistant infections for MRSA, VRE, ESBL, and MDRO. National estimates were generated, frequencies were compared across years, and multivariate regression for mortality was performed. RESULTS: From 2017 to 2020, national weighted estimates of 835,540 inpatient ERCPs were generated, and 11,440 ERCPs had coincident resistant infections. Overall resistant infection, MRSA, VRE, and MDRO identified at the same hospitalization of inpatient ERCPs were associated with higher mortality (OR CI(95%): Overall: 2.2(1.77-2.88), MRSA: 1.90 (1.34-2.69), VRE: 3.53 (2.16-5.76), and MDRO: 2.52 (1.39-4.55)). While overall hospitalizations with resistant infections have been decreasing annually, there has been a yearly increase in admissions requiring ERCPs with simultaneous resistant infections ( P =0.001-0.013), as well as infections with VRE, ESBL, and MDRO ( P =0.001-0.016). Required Research Practices for Studies Using the NIS scoring was 0, or the most optimal. CONCLUSIONS: Inpatient ERCPs have increasing coincident resistant infections and are associated with higher mortality. These rising infections during ERCP highlight the importance of endoscopy suite protocols and endoscopic infection control devices.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Pacientes Internados , Humanos , Estados Unidos/epidemiologia , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Estudos Transversais , Antibacterianos/uso terapêutico , Estudos de Coortes , Estudos Retrospectivos
3.
J Clin Gastroenterol ; 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38112649

RESUMO

OBJECTIVE: Endoscopic ultrasound (EUS) is routinely used for fiducial marker placement (FMP) to guide stereotactic radiation of pancreatic tumors, but EUS-FMP explicitly to guide surgery has not been studied in a prospective, controlled manner. Multipurpose EUS systems have been developed that facilitate simultaneous EUS-FMP at the time of biopsy. We aimed to evaluate the feasibility of EUS-FMP to guide pancreatic resection. METHODS: In this prospective trial, we enrolled patients with resectable pancreas masses undergoing tissue sampling and placed preloaded fiducials immediately after biopsy. Intraprocedure confirmation of carcinoma, neuroendocrine, and nonlymphomatous neoplasia by rapid on-site evaluation and lesion size <4 cm was required. The main outcomes were the feasibility and ease of preoperative placement and intraoperative detection of the markers using predefined Likert scales. RESULTS: In 20 patients, EUS-FMP was successful before planned surgery and placement was technically straightforward (Likert Scale: 9.1 ± 1.3; range: 1, most challenging to 10, most facile). Intraoperative detection was feasible and improved when compared with a pre-established comparator of 5 representing an equivalent lesion without a marker (Likert Scale: 7.8 ± 2.2; range: 1, most difficult to 10, most facile; P = 0.011). The mean tumor size on EUS was 1.7 ± 0.9 (range: 0.5 to 3.6) cm. CONCLUSION: EUS-FMP is feasible and safe for resectable pancreatic tumors before surgery and may assist in perioperative detection. Preloaded fiducials may be considered for placement at the time of initial referral for EUS-fine needle biopsy.

4.
Endosc Int Open ; 11(10): E935-E942, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37818454

RESUMO

Background and study aims Colorectal malignancy is a leading cause of death. Conventional endoscopic mucosal resection (CEMR) is a strategy used to resect precancerous lesions that involves injecting fluid beneath a polyp to create a gap for resection. Underwater endoscopic mucosal resection (UEMR) is a newer method that forgoes injection, instead filling the intestinal cavity with water to facilitate polyp resection. Our aim was to compare the safety and efficacy of these approaches by synthesizing the most contemporary evidence. Methods PubMed, Embase, and Cochrane libraries were searched from inception through November 11, 2022 for randomized controlled trials (RCTs) comparing UEMR and CEMR for resection of colorectal lesions. The primary outcome was the rate of en bloc resection and secondary outcomes included recurrence, procedure time, and adverse events (AEs). Results A total of 2539 studies were identified through our systematic literature search. After screening, seven RCTs with a total of 1581 polyps were included. UEMR was associated with significantly increased rates of en bloc resection (RR 1.18 [1.03, 1.35]; I 2 = 76.6%) versus conventional approaches. No significant differences were found in procedure time, recurrence, or AEs. Conclusions UEMR is a promising effective technique for removal of colorectal lesions. The most contemporary literature indicates that it improves en bloc resection rate without increasing procedure time, recurrence, or AEs (PROSPERO ID CRD42022374935).

5.
VideoGIE ; 8(1): 8-10, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36644241

RESUMO

Video 1Hybrid resection of gastric GI stromal tumor with endoscopic submucosal dissection and the Full-Thickness Resection Device.

6.
Radiol Case Rep ; 17(10): 3504-3510, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35912298

RESUMO

Schwannomas are common peripheral nerve sheath tumors that typically occur on the head, neck, trunk, or extremities. Intra-abdominal schwannomas, however, are rare. We describe a young woman who presented for imaging evaluation of suspected nephrolithiasis and was incidentally found to have a schwannoma centered within the pancreatic parenchyma. In addition, we detail the clinical, imaging, and histopathologic features of pancreatic schwannoma and summarize diagnosis and management of this rare clinical entity.

7.
Endosc Ultrasound ; 11(1): 53-58, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35102901

RESUMO

BACKGROUND AND OBJECTIVES: EUS-guided drainage of pancreatic fluid collections (PFCs) has been increasingly performed using lumen-apposing metal stents (LAMS). However, recent data have suggested higher adverse event rates with LAMS compared to double pigtail plastic stents (DPS) alone. To decrease risks, there has been anecdotal use of placing DPS through the LAMS. We aimed to determine whether the placement of DPS through cautery-enhanced LAMS at time of initial placement decreases adverse events or need for reintervention. METHODS: We performed a multicenter retrospective study between January 2015 and October 2017 examining patients who underwent EUS-guided drainage of pseudocysts (PP), walled-off necrosis (WON), and postsurgical fluid collection using a cautery enhanced LAMS with and without DPS. RESULTS: There were 68 patients identified at 3 US tertiary referral centers: 44 PP (65%), 17 WON (25%), and 7 PFSC (10%). There were 35 patients with DPS placed through LAMS (Group 1) and 33 with LAMS alone (Group 2). Overall technical success was 100%, clinical success was 94%, and adverse events (bleeding, perforation, stent occlusion, and stent migration) occurred in 28% of patients. Subgroup analysis compared specific types of PFCs and occurrence of adverse events between each group with no significant difference detected in adverse event or reintervention rates. CONCLUSION: This multicenter study of various types of PFCs requiring EUS-guided drainage demonstrates that deployment of DPS across cautery-enhanced LAMS at the time of initial drainage does not have a significant effect on clinical outcomes, adverse events, or need for reinterventions.

10.
Clin Colon Rectal Surg ; 33(1): 16-21, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31915421

RESUMO

Bleedings from small intestine account for 5% of all gastrointestinal bleeding. With advanced endoscopic tools, such as video capsule endoscopy and deep enteroscopy, accurate diagnosis and treatment is possible in majority of cases with low mortality and morbidity. Nonoperative management includes endoscopic hemostasis and angiographic embolization. Recurrence after initial treatment is relatively common. Surgery is reserved for the cases that are refractory to endoscopic or angiographic treatment, bleeding from tumor or mass lesions, or hemodynamic instability. At the time of surgical exploration, unless the lesion has been marked by endoscopic tattoo or clip, intraoperative enteroscopy is often necessary to localize the lesion.

12.
Clin Gastroenterol Hepatol ; 18(4): 917-925.e4, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31499247

RESUMO

BACKGROUND & AIMS: Endoscopic ultrasound (EUS) is a sensitive method to evaluate the pancreas but its diagnostic capability for several diseases is limited. We compared the diagnostic yield of unenhanced EUS with that of contrast-enhanced EUS for focal pancreas lesions and identified and tested quantitative parameters of contrast enhancement. METHODS: We performed a prospective tandem-controlled trial in which 101 patients with focal pancreas lesions (48 with masses, 28 with cysts, and 25 with pancreatitis) underwent conventional EUS followed by contrast EUS using intravenous perflutren microspheres. The diagnosis at each stage was scored and compared with a standard (findings from surgical pathology analysis, cytologic, and/or 6-month clinical follow-up evaluations). Quantitative parameters were generated by time-intensity curve analysis. Solid lesions were divided into derivation and testing cohorts for a crossover validation analysis of the quantitative parameters. The primary outcome was diagnostic yield of unenhanced vs contrast EUS in analysis of focal pancreas lesions. RESULTS: Contrast increased the diagnostic yield of EUS from 64% (65/101 lesions accurately assessed) to 91% (92/101 lesions accurately assessed); the odds ratio [OR] was 7.8 (95% CI, 2.7-30.2) for accurate analysis of lesions by contrast-enhanced EUS relative to unenhanced EUS. The contrast increased accuracy of analysis of pancreas masses (OR, 6.0; 95% CI, 1.8-31.8), improving assessment of neuroendocrine and other (non-carcinoma) tumors. Contrast increased the diagnostic yield for pancreas cysts to 96% (27/28) compared with 71.4% (20/28) for unenhanced EUS (P = .02), due to improved differentiation of mural nodules vs debris. Time-intensity curve analysis revealed distinct patterns of relative peak enhancement (rPE) and in-slope (rIS) for different lesions following contrast injection: for adenocarcinomas, values were low rPE and low rIS; for neuroendocrine masses, values were high rPE and normal IS; and for chronic pancreatitis foci, values were normal rPE and low rIS. In the validation cohort, these parameters correctly characterized 91% of lesions and improved yield relative to unenhanced EUS (OR, 10; 95% CI, 1.4-34.0). CONCLUSIONS: Contrast-enhanced EUS improves the accuracy of analysis of focal pancreas lesions, compared with unenhanced EUS. Integration of practical quantitative parameters, specifically relative peak enhancement and in-slope, might increase the diagnostic accuracy of contrast EUS. ClinicalTrials.gov no: 02863770.


Assuntos
Neoplasias Pancreáticas , Meios de Contraste , Endossonografia , Humanos , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Estudos Prospectivos , Sensibilidade e Especificidade
15.
Pancreas ; 48(1): 66-69, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30451795

RESUMO

OBJECTIVES: Distinguishing neuroendocrine tumors (NETs) and other pancreas lesions from adenocarcinomas via endoscopic ultrasound (EUS) requires additional tissue for special staining and processing. Our aim was to determine if main pancreatic duct (PD) diameter on EUS helps to differentiate NET and other unusual tumors from adenocarcinoma. METHODS: We evaluated 30 consecutive patients diagnosed with NET or other pancreas lesions by EUS with 90 matched patients who were found to have adenocarcinoma. Dilated PD was defined as greater than 3 mm. Multivariate logistic regression was used to evaluate associations between lesion type and PD diameter. RESULTS: Among the 30 patients with NET/other pancreas lesions, 21 had NETs, 7 had metastases, and 2 had lymphomas. A dilated PD was demonstrated in only 3.3% of pancreatic NET/other lesions but present in 88.9% of cases of primary adenocarcinoma (P < 0.01). In multivariate analysis, a normal PD diameter and absence of clinical symptoms strongly predicted the presence of pancreatic NET/other versus adenocarcinoma (P < 0.01). CONCLUSIONS: The absence of PD dilation upstream of the lesion suggests NET or other lesions rather than adenocarcinoma. This finding should prompt endosonographers to obtain additional tissue at the time of EUS to send for special studies.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Endossonografia/métodos , Tumores Neuroendócrinos/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Ductos Pancreáticos/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Adenocarcinoma/diagnóstico , Diagnóstico Diferencial , Humanos , Modelos Logísticos , Análise Multivariada , Tumores Neuroendócrinos/diagnóstico , Pâncreas/patologia , Ductos Pancreáticos/anatomia & histologia , Neoplasias Pancreáticas/diagnóstico , Estudos Prospectivos
17.
Gastrointest Endosc Clin N Am ; 28(2): 233-249, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29519335

RESUMO

The development of new endoscopic techniques, such as gastrointestinal (GI) stenting, full-thickness suturing, clip application, and use of tissue adhesives, has had a significant impact on management of GI fistulae. These techniques have shown promising results, but further study is needed to optimize the efficacy of long-term closure. The advancement of endoscopic techniques, including the use of the lumen apposing metal stent (LAMS), has allowed for the deliberate creation of fistula tracts to apply endoscopic therapy that previously could not be achieved. This article examines the rapidly evolving area of endoscopic fistula closure and its relationship to LAMS.


Assuntos
Fístula Anastomótica/terapia , Fístula do Sistema Digestório/terapia , Endoscopia Gastrointestinal/métodos , Fístula Anastomótica/diagnóstico por imagem , Fístula do Sistema Digestório/diagnóstico por imagem , Endoscopia Gastrointestinal/instrumentação , Humanos , Implantação de Prótese/métodos , Stents , Instrumentos Cirúrgicos , Técnicas de Sutura , Adesivos Teciduais/administração & dosagem
19.
Gastrointest Endosc ; 87(4): 1050-1060, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28866457

RESUMO

BACKGROUND AND AIMS: Bile duct stones >1 cm have a decreased incidence of successful endoscopic extraction and often require lithotripsy. Although previous guidelines suggested mechanical lithotripsy for large common bile duct stones, current guidelines suggest cholangioscopy-guided lithotripsy as an adjunct with or without balloon dilation or mechanical lithotripsy. However, no randomized trials have assessed the usefulness of this practice. METHODS: Patients with bile duct stones >1 cm in diameter were randomized in a 2:1 ratio to cholangioscopy-guided laser lithotripsy versus conventional therapy only. Conventional therapies such as mechanical lithotripsy or balloon dilation were also allowed in the laser lithotripsy group. Randomization was stratified by history of ERCP in the past 3 months. The primary outcome was endoscopic clearance of the bile duct stones. RESULTS: Endoscopic clearance was achieved in 39 (93%) of 42 patients treated with cholangioscopy-guided laser lithotripsy and 12 (67%) of 18 treated with conventional therapy only (P = .009). The 9 patients in whom ERCP was unsuccessful underwent surgical common duct exploration with stone removal. Mean procedure time was 120.7 ± 40.2 minutes for the cholangioscopy-guided laser lithotripsy group compared with 81.2 ± 49.3 minutes for the conventional therapy group (P = .0008). There was no significant difference in fluoroscopy time, number of procedures, or adverse events (cholangitis) (cholangioscopy, 2; conventional, 1) and post-ERCP pancreatitis (cholangioscopy, 2; conventional, 1). CONCLUSION: Cholangioscopy-guided laser lithotripsy increases the incidence of endoscopic clearance of large bile duct stones and decreases the need for surgery compared with conventional therapy alone. However, it is associated with longer procedure times. (Clinical trial registration number: NCT0175997.).


Assuntos
Coledocolitíase/terapia , Litotripsia a Laser/métodos , Adulto , Colangite/etiologia , Endoscopia do Sistema Digestório/métodos , Feminino , Fluoroscopia , Humanos , Litotripsia a Laser/efeitos adversos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Pancreatite/etiologia , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
20.
Gastrointest Endosc ; 87(4): 1122-1125, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28843585

RESUMO

BACKGROUND AND AIMS: Pancreatic fistula is a challenging yet common adverse event of partial pancreatectomy. Our objective is to determine the feasibility of endoscopic closure of a pancreatic fistula using a combination of a metallic coil and N-butyl-2-cyanoacrylate (NBCA) glue. METHODS: A patient with a postoperative pancreatic stump leak recalcitrant to conservative management and pancreatic duct stent placement underwent endoscopic/fluoroscopic placement of a metallic coil in the pancreatic duct followed by injection of .5 mL NBCA and lipiodol mixture directed at the coil. The patient's clinical condition, Jackson-Pratt (JP) drain output, and pancreatic enzyme content were monitored daily after the procedure. RESULTS: The patient's clinical condition improved. JP drain output and amylase/lipase levels progressively decreased to resolution within 7 days of the procedure. No adverse events occurred as a result of the procedure. CONCLUSIONS: Endoscopic closure of pancreatic fistula with a metallic coil and NBCA glue is feasible and may be a useful modality for treatment of refractory postpancreatectomy-related fistula.


Assuntos
Embucrilato/uso terapêutico , Fístula Pancreática/terapia , Próteses e Implantes , Adesivos Teciduais/uso terapêutico , Endoscopia do Sistema Digestório , Humanos , Masculino , Pessoa de Meia-Idade , Pancreatectomia/efeitos adversos , Fístula Pancreática/etiologia , Platina , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA