Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Gastroenterol ; 22(1): 424, 2022 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-36115968

RESUMO

BACKGROUND: Colonoscopy is a standard procedure for evaluating colon diseases and screening for colorectal cancer, and bowel cleanliness prior to colonoscopy is key. The aim of this study was to compare the bowel cleansing efficacy of low-volume (2 L) split-dose polyethylene glycol (PEG) plus single-dose (24 µg) lubiprostone (LB) and high-volume (4 L) split-dose PEG. METHODS: Patients scheduled to undergo outpatient colonoscopy between December 2019 and June 2021 at Rajavithi Hospital were enrolled and randomized into two groups: 2 L PEG + LB or 4 L PEG. Colon cleanliness was evaluated using the Boston Bowel Preparation Scale (BBPS) by reviewing images of the colon after completion of colonoscopy. Secondary outcomes comprised cecal intubation rate, procedure time, withdrawal time, polyp detection rate, adenoma detection rate, patient satisfaction, compliance (based on complete ingestion of bowel preparation regimen), willingness to repeat the preparation regimen, and associated adverse events. RESULTS: One hundred and forty patients were included, with 70 in each group. The mean total and segment-specific BBPS scores were not significantly different between groups. However, the rate of adequate bowel preparation was significantly higher in the 2 L PEG + LB group than the 4 L PEG group (100% [95% CI 94.6-100] versus 88.4% [95% CI 78.4-94.9], p = 0.004) in the per-protocol analysis. Colonic polyps were the most common finding. The polyp detection rate, adenoma detection rate, and all secondary outcomes were statistically similar in the two groups (p > 0.05). CONCLUSIONS: The combination of 2 L split-dose PEG plus LB improves bowel cleanliness (based on BBPS scores) to a comparable degree to the standard 4 L split-dose PEG, without additional adverse events and with a lower PEG volume.


Assuntos
Catárticos , Polietilenoglicóis , Catárticos/efeitos adversos , Ceco , Colonoscopia/métodos , Humanos , Lubiprostona , Polietilenoglicóis/efeitos adversos
2.
BMC Gastroenterol ; 21(1): 222, 2021 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-34001027

RESUMO

BACKGROUND: Jackhammer esophagus is a rare esophageal motility disorder that can result in dysphagia, chest pain, and gastro-esophageal reflux symptoms. High-resolution manometry is the gold standard for diagnosis, while corkscrew esophagus on upper gastrointestinal endoscopy is an uncommon manifestation. CASE PRESENTATION: 72-year-old man who presented with progressive dysphagia for three months without symptoms of chest pain or heartburn. Initial workup showed a corkscrew esophagus on upper gastrointestinal endoscopy; subsequently, high-resolution manometry revealed an esophago-gastric junction outflow obstruction with hypercontractile (jackhammer) esophagus. Treatment with calcium channel blockers and proton pump inhibitors was successful and relieved his symptoms near completion. CONCLUSIONS: Even though the corkscrew esophagus is typically for distal esophageal spasm, the hypercontractile (jackhammer) esophagus can appear. The high-resolution manometry can help to distinguish each specific motility disorder.


Assuntos
Transtornos de Deglutição , Transtornos da Motilidade Esofágica , Espasmo Esofágico Difuso , Idoso , Transtornos de Deglutição/etiologia , Humanos , Masculino , Manometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA