Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Surg Obes Relat Dis ; 10(6): 1028-39, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25443077

RESUMO

BACKGROUND: Bariatric surgery is the most effective treatment for the reduction of weight and resolution of type 2 diabetes mellitus (T2 DM). The objective of this study was to longitudinally assess hormonal and tissue responses after RYGB. METHODS: Eight patients (5 with T2 DM) were studied before and after RYGB. A standardized test meal (STM) was administered before and at 1, 3, 6, 9, 12, and 15 months. Separately, a 2-hour hyperinsulinemic-euglycemic clamp (E-clamp) and a 2-hour hyperglycemic clamp (H-clamp) were performed before and at 1, 3, 6, and 12 months. Glucagon-like peptide-1 (GLP-1) was infused during the last hour of the H-clamp. Body composition was assessed with DXA methodology. RESULTS: Enrollment body mass index was 49±3 kg/m(2) (X±SE). STM glucose and insulin responses were normalized by 3 and 6 months. GLP-1 level increased dramatically at 1, 3, and 6 months, normalizing by 12 and 15 months. Insulin sensitivity (M of E-clamp) increased progressively at 3-12 months as fat mass decreased. The insulin response to glucose alone fell progressively over 12 months but the glucose clearance/metabolism (M of H-clamp) did not change significantly until 12 months. In response to GLP-1 infusion, insulin levels fell progressively throughout the 12 months. CONCLUSION: The early hypersecretion of GLP-1 leads to hyperinsulinemia and early normalization of glucose levels. The GLP-1 response normalizes within 1 year after surgery. Enhanced peripheral tissue sensitivity to insulin starts at 3 months and is associated with fat mass loss. ß-cell sensitivity improves at 12 months and after the loss of ≈33% of excess weight. There is a tightly controlled feedback loop between peripheral tissue sensitivity and ß-cell and L-cell (GLP-1) responses.


Assuntos
Diabetes Mellitus Tipo 2/prevenção & controle , Derivação Gástrica/métodos , Obesidade Mórbida/cirurgia , Absorciometria de Fóton , Biomarcadores/sangue , Glicemia/análise , Composição Corporal , Índice de Massa Corporal , Peptídeo C/sangue , Ensaio de Imunoadsorção Enzimática , Feminino , Glucagon/sangue , Peptídeo 1 Semelhante ao Glucagon/administração & dosagem , Peptídeo 1 Semelhante ao Glucagon/sangue , Técnica Clamp de Glucose , Humanos , Insulina/sangue , Masculino , Pessoa de Meia-Idade , Redução de Peso
2.
J Surg Res ; 167(2): 199-205, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21414635

RESUMO

BACKGROUND: Profound hypoglycemia occurs rarely as a late complication after Roux-en-Y gastric bypass (RYGB). We investigated the role of glucagon-like-peptide-1 (GLP-1) in four subjects who developed recurrent neuro-glycopenia 2 to 3 y after RYGB. METHODS: A standardized test meal (STM) was administered to all four subjects. A 2 h hyperglycemic clamp with GLP-1 infusion during the second hour was performed in one subject, before, during a 4 wk trial of octreotide (Oc), and after 85% distal pancreatectomy. After cessation of both glucose and GLP-1 infusion at the end of the 2 h clamp, blood glucose levels were monitored for 30 min. Responses were compared with a control group (five subjects 12 mo status post-RYGB without hypoglycemic symptoms). RESULTS: During STM, both GLP-1 and insulin levels were elevated 3- to 4-fold in all subjects, and plasma glucose-dependent insulinotropic peptide (GIP) levels were elevated 2-fold. Insulin responses to hyperglycemia ± GLP-1 infusion in one subject were comparable to controls, but after cessation of glucose infusion, glucose levels fell to 40 mg/dL. During Oc, the GLP-1 and insulin responses to STM were reduced (>50%). During the clamp, insulin response to hyperglycemia alone was reduced, but remained unchanged during GLP-1. Glucagon levels during hyperglycemia alone were suppressed and further suppressed after the addition of GLP-1. With the substantial drop in glucose during the 30 min follow-up, glucagon levels failed to rise. Due to persistent symptoms, one subject underwent 85% distal pancreatectomy; postoperatively, the subject remained asymptomatic (blood glucose: 119-220 mg/dL), but a repeat STM showed persistence of elevated levels of GLP-1. Histologically enlarged islets, and ß-cell clusters scattered throughout the acinar parenchyma were seen, as well as ß-cells present within pancreatic duct epithelium. An increase in pancreatic and duodenal homeobox-1 protein (PDX-1) expression was observed in the subject compared with control pancreatic tissue. CONCLUSIONS: A persistent exaggerated hypersecretion of GLP-1, which has been shown to be insulinotropic, insulinomimetic, and glucagonostatic, is the likely cause of post-RYGB hypoglycemia. The hypertrophy and ectopic location of ß-cells is likely due to overexpression of the islet cell transcription factor, PDX-1, caused by prolonged hypersecretion of GLP-1.


Assuntos
Sistema Endócrino/fisiopatologia , Derivação Gástrica/efeitos adversos , Trato Gastrointestinal/fisiopatologia , Hiperinsulinismo/etiologia , Hipoglicemia/etiologia , Obesidade/cirurgia , Pâncreas/fisiopatologia , Glicemia/metabolismo , Feminino , Polipeptídeo Inibidor Gástrico/metabolismo , Peptídeo 1 Semelhante ao Glucagon/metabolismo , Peptídeo 1 Semelhante ao Glucagon/farmacologia , Glicogênio/metabolismo , Proteínas de Homeodomínio/metabolismo , Humanos , Hiperinsulinismo/fisiopatologia , Hipoglicemia/fisiopatologia , Insulina/metabolismo , Pessoa de Meia-Idade , Transativadores/metabolismo
3.
J Diabetes Sci Technol ; 5(6): 1521-8, 2011 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-22226275

RESUMO

INTRODUCTION: The effects of pancreatic polypeptide (PP) infusion were examined in patients on insulin pump therapy to determine whether PP administration can reduce insulin requirements in patients with type 1 diabetes mellitus (T1DM) or type 3c diabetes mellitus (T3cDM; pancreatogenic). METHODS: Ten subjects with long-standing T1DM (n = 7) or T3cDM (n = 3) on insulin pump treatment received a 72 h subcutaneous infusion of 2 pmol/kg/min bovine PP or saline by portable infusion pump in a single-blinded, randomized, crossover design. RESULTS: Pancreatic polypeptide infusion raised plasma PP levels to 450-700 pmol/liter. Daily insulin infusion requirements (I) fell from 48 ± 6.9 to 40 ± 7.5 U on day 2 (p < .05) and from 46 ± 7.7 to 37 ± 6.6 U on day 3 (p < .05) of PP infusion compared with saline. Corrected for average blood glucose concentration (G), I/G fell in 10/10 subjects during the second 24 h period and in 7/10 subjects during the third 24 h period; sensitivity to insulin, calculated as 1/(I/G), increased 45% ± 12% on day 2 (p < .01) and 34% ± 14% on day 3 (p < .05) of PP infusion. Pancreatic polypeptide responses to a test meal were compared with the change in insulin infusion requirements in 5 subjects; the reduction in insulin requirements seen during PP infusion correlated with the degree of baseline PP deficiency (p < .002). CONCLUSIONS: A concurrent subcutaneous infusion of PP enhances insulin sensitivity and reduces insulin requirements in patients with long-standing T1DM and T3cDM on insulin pump therapy. The benefit of PP infusion correlated with the degree of PP deficiency.


Assuntos
Diabetes Mellitus/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Resistência à Insulina/fisiologia , Polipeptídeo Pancreático/administração & dosagem , Adulto , Idoso , Glicemia/análise , Estudos Cross-Over , Feminino , Humanos , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Pessoa de Meia-Idade , Polipeptídeo Pancreático/sangue , Método Simples-Cego , Adulto Jovem
4.
J Diabetes Sci Technol ; 4(5): 1195-201, 2010 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-20920440

RESUMO

AIMS/HYPOTHESIS: The Andres clamp technique, which requires accurate and timely determination of glucose, utilizes the Beckman or Yellow Springs Instruments (YSI) glucose analyzers. Both instruments require maintenance, a dedicated operator, preparation of a plasma sample, and a duplicate measurement that takes ≥2 minutes. The Nova StatStrip glucose meter was evaluated for accuracy, reliability, and near-real-time availability of glucose. METHODS: Blood samples from 24 patients who underwent 6-hour clamp studies and 12 patients who had a standardized meal tolerance test (SMT) were measured. Specimens were analyzed simultaneously and immediately upon collection by Beckman, YSI, and Nova. RESULTS: Of 1004 data pairs for the Nova device versus Beckman, the Nova data points ranged from 32 to 444, while Beckman ranged from 42 to 412. The coefficient for the slope of Beckman versus Nova was 1.009 (r = 0.978). Using error grid analysis, the number and percentage of values for Nova were 976 (97.2%) in the A zone and 28 (2.8%) in the B zone. Of 399 data pairs for the Nova device versus YSI, the Nova data points ranged from 46 to 255, whereas YSI ranged from 47 to 231. The coefficient for the slope of YSI versus Nova was 1.023 (r = 0.989). All Nova readings fell in the A zone. Time required for final reading, in duplicate, was 15 seconds for Nova and 120-180 seconds for Beckman and YSI. CONCLUSIONS: The simplicity of Nova and its reliability, accuracy, and speed make it an acceptable replacement device for Beckman and YSI in the conduct of clamps, especially when perturbations require rapid glucose determination.


Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/metabolismo , Diabetes Mellitus/sangue , Monitorização Fisiológica/instrumentação , Automonitorização da Glicemia/métodos , Técnica Clamp de Glucose , Humanos , Monitorização Fisiológica/métodos , Reprodutibilidade dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA