Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
J Clin Med ; 13(5)2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38592316

RESUMO

Background. The significance of concomitant tricuspid regurgitation (TR) in the context of transcatheter aortic valve replacement (TAVR) remains unclear. This study aimed to analyze the severity of TR before and after TAVR with regard to short- and long-term survival and to analyze the influencing factors. Methods. In our retrospective analysis, TR before and after TAVR was examined and patients were classified into groups accordingly. Special attention was paid to patients with post-interventional changes in TR. Mortality after TAVR was considered the primary endpoint of the analysis and major complications according to the Valve Academic Research Consortium 3 (VARC3) were compared. Moreover, biomarkers and risk factors for worsening or improvement of TR through TAVR were analyzed. Results. Among 775 patients who underwent TAVR in our center between January 2009 and December 2019, 686 patients (89%) featured low- and 89 patients (11%) high-grade TR. High-grade pre-TAVR TR was associated with worse short- (30-day), mid- (2-year) and long-term survival up to 8 years. Even though in nearly half of the patients with high-grade TR the regurgitation improved within seven days after TAVR (n = 42/89), this did not result in a survival benefit for this subgroup. On the other hand, a worsening of low-grade TR was seen in more than 10% of the patients (n = 73/686), which was also associated with a worse prognosis. Predictors of worsening of TR after TAVR were adipositas, impaired right ventricular function and the presence of mild TR. Age, atrial fibrillation, COPD, impaired renal function and elevated cardiac biomarkers were risk factors for mortality after TAVR independent from the grade of TR. Conclusions. Not only pre-interventional, but also post-TAVR high-grade TR is associated with a worse prognosis after TAVR. TAVR can change concomitant tricuspid regurgitation, but improvement does not have any impact on short- and long-term survival. Worsening of TR after TAVR is possible and impairs the prognosis.

2.
Clin Neuroradiol ; 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38289376

RESUMO

PURPOSE: Multiple sclerosis (MS) is a prevalent autoimmune inflammatory disease. Besides cerebral manifestations, an affection of the spinal cord is typical; however, imaging of the spinal cord is difficult due to its anatomy. The aim of this study was to assess the diagnostic value of a 3D PSIR pulse sequencing at a 1.5 T magnetic field strength for both the cervical and thoracic spinal cord. METHODS: Phase sensitive inversion recovery (PSIR), short tau inversion recovery (STIR) and T2-weighted (T2-w) images of the spinal cord of 50 patients were separately evaluated by three radiologists concerning the number and location of MS lesions. Furthermore, lesion to cord contrast ratios were determined for the cervical and thoracic spinal cord. RESULTS: Of the lesions 54.81% were located in the cervical spinal cord, 42.26% in the thoracic spinal cord and 2.93% in the conus medullaris. The PSIR images showed a higher sensitivity for lesion detection in the cervical and thoracic spinal cord (77.10% and 72.61%, respectively) compared to the STIR images (58.63% and 59.10%, respectively) and the T2-w images (59.95% and 59.52%, respectively). The average lesion to cord contrast ratio was significantly higher in the PSIR images compared to the STIR images (p < 0.001) and the T2-w images (p < 0.001). CONCLUSION: Evaluation of the spinal cord with a 3D PSIR sequence at a magnetic field strength of 1.5 T is feasible with a high sensitivity for the detection of spinal MS lesions for the cervical as well as the thoracic segments. In combination with other pulse sequences it might become a valuable addition in an advanced imaging protocol.

4.
Artigo em Inglês | MEDLINE | ID: mdl-37341633

RESUMO

OBJECTIVES: Pulmonary valve regurgitation is a common problem after relief of right ventricular outflow tract (RVOT) obstruction with a transannular patch. Pulmonary valve replacement with a homograft or xenograft is the routine treatment. Longevity of biological valves and the availability of homografts are limited. Alternatives to restore RVOT competence are evaluated. The goal of this study was to present intermediate-term results for pulmonary valve reconstruction (PVr) in patients with severe regurgitation. METHODS: PVr was performed in 24 patients (August 2006‒July 2018). We analysed perioperative data, pre- and postoperative cardiac magnetic resonance (CMR) imaging studies, freedom from valve replacement and risk factors for pulmonary valve dysfunction. RESULTS: The underlying diagnoses were tetralogy of Fallot (n = 18, 75%), pulmonary stenosis (n = 5, 20.8%) and the double outlet right ventricle post banding procedure (n = 1, 4.2%). The median age was 21.5 (14.8-23.7) years. Main (n = 9, 37.5%) and branch pulmonary artery procedures (n = 6, 25%) and surgery of the RVOT (n = 16, 30.2%) were often part of the reconstruction. The median follow-up after the operation was 8.0 (4.7-9.7) years. Freedom from valve failure was 96% at 2 and 90% at 5 years. The mean longevity of the reconstructive surgery was 9.9 years (95% confidence interval: 8.8-11.1 years). CMR before and 6 months after surgery showed a reduction in the regurgitation fraction [41% (33-55) vs 20% (18-27) P = 0.00] and of the indexed right ventricular end-diastolic volume [156 ml/m2 (149-175) vs 116 ml/m2 (100-143), P = 0.004]. Peak velocity across the pulmonary valve (determined by CMR) half a year after surgery was 2.0, unchanged. CONCLUSIONS: PVr can be achieved with acceptable intermediate-term results and may delay pulmonary valve replacement.

5.
Appl Psychophysiol Biofeedback ; 48(4): 393-401, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37341838

RESUMO

The value of biofeedback before elective coronary computed tomography angiography (CCTA) to reduce patients' heart rates (HR) was investigated in the current work. Sixty patients who received CCTA to exclude coronary artery disease were included in our study and separated into two groups: with biofeedback (W-BF) and without biofeedback (WO-BF). The W-BF group used a biofeedback device for 15 min before CCTA. HR was determined in each patient at four measurement time points (MTP): during the pre-examination interview (MTP1), positioning on the CT patient table before CCTA (MTP2), during CCTA image acquisition (MTP3), and after completing CCTA (MTP4). If necessary, beta-blockers were administered in both groups after MTP2 until a HR of less than 65 bpm was achieved. Two board-certified radiologists subsequently assessed the image quality and analyzed the findings. Overall, the need for beta-blockers was significantly lower in patients in the W-BF group than the WO-BF group (p = 0.032). In patients with a HR of 81-90, beta-blockers were not required in four of six cases in the W-BF group, whereas in the WO-BF group all patients needed beta-blockers (p = 0.03). The amount of HR reduction between MTP1 and MTP2 was significantly higher in the W-BF compared to the WO-BF group (p = 0.028). There was no significant difference between the W-BF and WO-BF groups regarding image quality (p = 0.179). By using biofeedback prior to elective CCTA, beta-blocker use could be decreased without compromising CT image quality and analysis, especially in patients with an initial HR of 81-90 bpm.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Humanos , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Frequência Cardíaca/fisiologia , Doença da Artéria Coronariana/terapia , Tomografia Computadorizada por Raios X
6.
J Clin Med ; 12(4)2023 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-36836170

RESUMO

(1) Background: Preoperative imaging of the lower leg arteries is essential for planning fibular grafting. The aim of this study was to evaluate the feasibility and clinical value of non-contrast-enhanced (CE) Quiescent-Interval Slice-Selective (QISS)-magnetic resonance angiography (MRA) for reliably visualizing the anatomy and patency of the lower leg arteries and for preoperatively determining the presence, number, and location of fibular perforators. (2) Methods: The anatomy and stenoses of the lower leg arteries and the presence, number, and location of fibular perforators were determined in fifty patients with oral and maxillofacial tumors. Postoperative outcomes of patients after fibula grafting were correlated with preoperative imaging, demographic, and clinical parameters. (3) Results: A regular three-vessel supply was present in 87% of the 100 legs. QISS-MRA was able to accurately assign the branching pattern in patients with aberrant anatomy. Fibular perforators were found in 87% of legs. More than 94% of the lower leg arteries had no relevant stenoses. Fibular grafting was performed in 50% of patients with a 92% success rate. (4) Conclusions: QISS-MRA has the potential to be used as a preoperative non-CE MRA technique for the diagnosis and detection of anatomic variants of lower leg arteries and their pathologies, as well as for the assessment of fibular perforators.

7.
J Clin Med ; 11(21)2022 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-36362779

RESUMO

PURPOSE: Contrast-enhanced (CE) angiographic techniques, such as computed tomographic angiography (CE-CTA), are most commonly used for follow-up imaging after endovascular aneurysm repair. In this study, CE-CTA and non-CE QISS-MRA were compared for the first time for assessing endoleaks and aneurysms at follow-up after abdominal EVAR. METHODS: Our study included 20 patients (17 male, median age 79.8 years) who underwent radial QISS-MRA and CE-CTA after EVAR at their first follow-up examination. Two interventional radiologists evaluated datasets from both techniques in each patient concerning presence of endoleaks, types of endoleaks, aneurysm diameter, and image quality. Interobserver and intermodal agreement were assessed with Cohen's Kappa. RESULTS: Image quality was rated as excellent or good for both modalities by both observers. Ferromagnetic embolization materials cause hyperdense artifacts in CE-CTA causing aneurysm sac diameter measurements to be inaccurate by up to 1 cm. Type 2 endoleaks with low-flow characteristics in CE-CTA were overlooked compared to radial QISS-MRA. Compared to CE-CTA, all endoleaks after abdominal EVAR were detected and classified correctly on QISS-MRA. The interobserver agreement between CE-CTA and QISS-MRA was almost perfect, except for type 2 endoleaks, where agreement was substantial. Intermodal aneurysm diameter correlate "very strongly" for both observers. CONCLUSIONS: Radial QISS-MRA is a contrast agent free technique for diagnosing and monitoring all types of endoleaks and aneurysms in patients after abdominal EVAR. It provides information about specific clinical questions concerning aneurysm diameter and presence and types of endoleaks without radiation exposure and the side effects associated with iodine-based contrast agents.

8.
J Clin Med ; 11(3)2022 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-35160094

RESUMO

(1) Background: Deep hypothermic circulatory arrest (DHCA) with selective antegrade cerebral perfusion (ACP) is an established cerebral protection technique for the conduction of complex surgical procedures involving the aortic arch. It is controversial whether the duration of DHCA is associated with adverse outcome in patients with acute type A aortic dissection (AAAD). Our goal was to investigate whether DHCA time was associated with surgical outcome in patients undergoing a surgical treatment of AAAD. (2) Methods: A total of 410 patients were divided into two groups based on the DHCA time less than 60 min and equal to or longer than 60 min. (3) Results: Patients with longer DHCA times were significantly younger (p = 0.001). Intraoperatively, complex procedures with aortic arch surgery were more common in patients with longer DHCA times (p < 0.001). Accordingly, cardiopulmonary bypass (p < 0.001), cross-clamping (p < 0.001) and DHCA times (p < 0.001) were significantly longer in this group. Postoperatively, only the duration of mechanical ventilation (p < 0.001) and the rate of tracheotomy were significantly higher in these patients. Thirty-day mortality was satisfactory for both groups (p = 0.746). (4) Conclusions: Our results showed that improvements in perioperative management including ACP allow for the successful performance of surgical treatment of AAAD under DHCA with a duration of even longer than 60 min.

9.
Tomography ; 8(1): 457-478, 2022 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-35202203

RESUMO

Four-dimensional (4D) flow MRI allows quantifying flow in blood vessels-non invasively and in vivo. The clinical use of 4D flow MRI in small vessels, however, is hampered by long examination times and limited spatial resolution. Compressed SENSE (CS-SENSE) is a technique that can accelerate 4D flow dramatically. Here, we investigated the effect of spatial resolution and CS acceleration on flow measurements by using 4D flow MRI in small vessels in vitro at 3 T. We compared the flow in silicon tubes (inner diameters of 2, 3, 4, and 5 mm) measured with 4D flow MRI, accelerated with four CS factors (CS = 2.5, 4.5, 6.5, and 13) and three voxel sizes (0.5, 1, and 1.5 mm3) to 2D flow MRI and a flow sensor. Additionally, the velocity field in an aneurysm model acquired with 4D flow MRI was compared to the one simulated with computational fluid dynamics (CFD). A strong correlation was observed between flow sensor, 2D flow MRI, and 4D flow MRI (rho > 0.94). The use of fewer than seven voxels per vessel diameter (nROI) resulted in an overestimation of flow in more than 5% of flow measured with 2D flow MRI. A negative correlation (rho = -0.81) between flow error and nROI were found for CS = 2.5 and 4.5. No statistically significant impact of CS factor on differences in flow rates was observed. However, a trend of increased flow error with increased CS factor was observed. In an aneurysm model, the peak velocity and stagnation zone were detected by CFD and all 4D flow MRI variants. The velocity difference error in the aneurysm sac did not exceed 11% for CS = 4.5 in comparison to CS = 2.5 for all spatial resolutions. Therefore, CS factors from 2.5-4.5 can appear suitable to improve spatial or temporal resolution for accurate quantification of flow rate and velocity. We encourage reporting the number of voxels per vessel diameter to standardize 4D flow MRI protocols.


Assuntos
Aneurisma , Imageamento por Ressonância Magnética , Aceleração , Velocidade do Fluxo Sanguíneo , Humanos , Hidrodinâmica , Imageamento por Ressonância Magnética/métodos
10.
Acta Radiol ; 63(5): 642-651, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-33853376

RESUMO

BACKGROUND: Soft-tissue sarcomas (STS) are rare malignancies of the soft tissue. PURPOSE: To assess whether the magnetic resonance imaging (MRI) configuration of primary STS can predict the configuration of a recurring tumor and whether the MRI configuration of multiple recurrences differs in one and the same patient. MATERIAL AND METHODS: Thirty-nine patients with histologically proven recurrent STS were included in this retrospective study and underwent pre- and post-treatment MRI. Three main configurations of primary and recurrent tumors were identified: polycyclic/multilobulated; ovoid/nodular; and streaky. RESULTS: Sixty recurrent lesions were detected: 34 ovoid/nodular; 15 polycyclic/multilobulated; and 11 streaky. Five recurrences were multifocal and eight were bifocal. Of 39 patients, 28 (71.8%) presented one recurrence within the MRI follow-up period (P = 0.006); in 10 patients (25.6%), up to three different configurations of recurring STS were identified in one patient. Recurrences of polycyclic/multilobulated primaries were mostly ovoid/nodular (48%; P = 0.003) or polycyclic/multilobulated (37%; P = 0.014), and recurring ovoid/nodular STS significantly most often showed the same configuration as the primary tumor (85%; P < 0.001). Primary STS with a streaky configuration recurred in all three configurations in roughly equal proportions. Homogeneity/heterogeneity and tumor borders are significantly associated with the configuration of recurrences. CONCLUSION: Primary STS configuration may help predict recurrent tumor configuration when the primary STS had a polycyclic/multilobulated or ovoid/nodular configuration. However, recurrent STS configuration can also differ from primary STS configuration, especially when the primary STS had a streaky configuration, rendering recurrent STS difficult to predict. Different configurations of recurrent STS in one and the same patient are common.


Assuntos
Sarcoma , Neoplasias de Tecidos Moles , Humanos , Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Recidiva , Estudos Retrospectivos , Sarcoma/diagnóstico por imagem , Neoplasias de Tecidos Moles/diagnóstico por imagem , Neoplasias de Tecidos Moles/patologia
11.
Int J Cardiol ; 349: 48-54, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-34808211

RESUMO

OBJECTIVES: To evaluate the ability of non-contrast enhanced magnetic resonance imaging (MRI) techniques to characterize Fontan associated liver disease (FALD) in adolescent and adult Fontan patients. METHODS: Fontan patients (n = 29) and healthy controls (n = 13) underwent an MRI protocol with T1, T2 and Apparent Diffusion Coefficient (ADC) mapping. Routine FALD screening included abdominal ultrasound and laboratory testing. RESULTS: Median follow-up after Fontan operation was 15.1 (IQR 12.0-16.8) years. Distinct differences in tissue characteristics were visualized. T1 and T2 relaxation times were prolonged in Fontan patients, particularly of the right lobe (T1: 745 (IQR 715-784) ms vs. 586 (IQR 555-602) ms, p < 0.001; T2: 63 (IQR 59-64) ms vs. 58 (IQR 56-60) ms, p = 0.002). Left lobe ADC was lower in Fontan patients (1.10 (IQR 1.06-1.18) x 10-3 mm2/s vs. 1.23 (IQR 1.19-1.29) x 10-3 mm2/s, p < 0.001). T2 mapping was able to differentiate between controls and Fontan patients with different FALD severity. Right lobe T2 was higher in patients with moderate or severe in comparison to those with no or mild changes and healthy controls (64 (IQR 61-67) ms vs. 60 (IQR 59-63) ms vs. 58 (IQR 56-60) ms, p = 0.001). CONCLUSIONS: Non-contrast enhanced MRI methods are able to visualize regional differences in liver tissue characteristics. T1 and T2 relaxation times were prolonged in Fontan patients suggestive of fibrosis or congestive hepatopathy, while reduced ADC might reflect impaired microperfusion. These methods have promising clinical potential for detection of liver abnormalities in Fontan patients. The usefulness of T2 mapping to grade FALD severity merits further investigation.


Assuntos
Técnica de Fontan , Hepatopatias , Adolescente , Adulto , Imagem de Difusão por Ressonância Magnética , Técnica de Fontan/efeitos adversos , Humanos , Hepatopatias/diagnóstico por imagem , Hepatopatias/cirurgia , Imageamento por Ressonância Magnética
13.
Clin Imaging ; 78: 256-261, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34171598

RESUMO

This work focuses on implementing a standardized and symptom-oriented flowchart for advanced cardiac imaging in a 24/7 emergency setting using a dual-layer spectral detector CT system. This flowchart was designed to optimize patient management and standardize imaging workflow. It includes acquisition parameters and contrast agent protocols for the most relevant clinical questions regarding cardiac CT imaging in the interdisciplinary emergency department. The automated reconstruction of symptom-oriented spectral images represents an additional strength here. This implementation is designed to be time-efficient and user-friendly and improves diagnostic quality, independent of the qualification level of clinical and technical personnel.


Assuntos
Meios de Contraste , Tomografia Computadorizada por Raios X , Serviço Hospitalar de Emergência , Humanos , Design de Software
14.
Int J Cardiovasc Imaging ; 37(8): 2549-2559, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33788063

RESUMO

Ventricular dysfunction is a well-known complication in single ventricle patients in Fontan circulation. As studies exclusively examining patients with a single left ventricle (SLV) are sparse, we assessed left ventricular (LV) function in SLV patients by using 2D-cardiovascular magnetic resonance (CMR) feature tracking (2D-CMR-FT) and 2D-speckle tracking echocardiography (2D-STE). 54 SLV patients (11.4, 3.1-38.1 years) and 35 age-matched controls (12.3, 6.3-25.8 years) were included. LV global longitudinal, circumferential and radial strain (GLS, GCS, GRS) and strain rate (GLSR, GCSR, GRSR) were measured using 2D-CMR-FT. LV volumes, ejection fraction (LVEF) and mass were determined from short axis images. 2D-STE was applied in patients to measure peak systolic GLS and GLSR. In a subgroup analysis, we compared double inlet left ventricle (DILV) with tricuspid atresia (TA) patients. The population consisted of 19 DILV patients, 24 TA patients and 11 patients with diverse diagnoses. 52 patients were in NYHA class I and 2 patients were in class II. Most SLV patients had a normal systolic function but median LVEF in patients was lower compared to controls (55.6% vs. 61.2%, p = 0.0001). 2D-CMR-FT demonstrated reduced GLS, GCS and GCSR values in patients compared to controls. LVEF correlated with GS values in patients (p < 0.05). There was no significant difference between GLS values from 2D-CMR-FT and 2D-STE in the patient group. LVEF, LV volumes, GS and GSR (from 2D-CMR-FT) were not significantly different between DILV and TA patients. Although most SLV patients had a preserved EF derived by CMR, our results suggest that, LV deformation and function may behave differently in SLV patients compared to healthy subjects.


Assuntos
Ventrículos do Coração , Função Ventricular Esquerda , Estudos de Casos e Controles , Ventrículos do Coração/diagnóstico por imagem , Humanos , Recém-Nascido , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
15.
Clin Neuroradiol ; 31(4): 911-920, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33688981

RESUMO

PURPOSE: Recurrent stroke is considered to increase the incidence of severe disability and death. For correct risk assessment and patient management it is essential to identify the origin of stroke at an early stage. Transthoracic echocardiography (TTE) is the initial standard of care for evaluating patients in whom a cardioembolic source of stroke (CES) is suspected but its diagnostic capability is limited. Transesophageal echocardiography (TEE) is considered as gold standard; however, this approach is time consuming, semi-invasive and not always feasible. We hypothesized that adding a delayed-phase cardiac computed tomography (cCT) to initial multimodal CT might represent a valid alternative to routine clinical echocardiographic work-up. MATERIAL AND METHODS: Patients with suspected acute cardioembolic stroke verified by initial multimodal CT and subsequently examined with cCT were included. The cCT was evaluated for presence of major CES and compared to routine clinical echocardiographic work-up. RESULTS: In all, 102 patients with suspected acute CES underwent cCT. Among them 60 patients underwent routine work-up with echocardiography (50 TTE and only 10 TEE). By cCT 10/60 (16.7%) major CES were detected but only 4 (6.7%) were identified by echocardiography. All CES observed by echocardiography were also detected by cCT. In 8 of 36 patients in whom echocardiography was not performed cCT also revealed a major CES. CONCLUSION: These preliminary results show the potential diagnostic yield of delayed-phase cCT to detect major CES and therefore could accelerate decision-making to prevent recurrence stroke. To confirm these results larger studies with TEE as the reference standard and also compared to TTE would be necessary.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Isquemia Encefálica/diagnóstico por imagem , Humanos , Estudo de Prova de Conceito , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Tomografia Computadorizada por Raios X
16.
Magn Reson Imaging ; 78: 58-68, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33582146

RESUMO

PURPOSE: Non-contrast-enhanced (CE) magnetic resonance angiography (MRA) techniques are of considerable interest for diagnosing vascular diseases in the upper extremities owing to the possibility of repeated examinations, sufficient coverage of the measurement volume, and because possible side effects of administering iodine- or gadolinium-based contrast agents and radiation exposure can be avoided. The aim of this study was to investigate the feasibility of an optimized electrocardiogram (ECG) triggered Cartesian quiescent interval slice selective (QISS) technique for MRA of hand arteries. MATERIAL AND METHODS: Both hands of 20 healthy volunteers (HVs) were examined using an optimized QISS-MRA pulse sequence at 1.5 Tesla. The wrist and hand arterial trees were divided into 36 segments. Cross-sectional areas (CSA) of all arterial segments were measured. For the technical evaluation of the pulse sequence, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were computed and six imaging artifacts were graded. Two experienced observers used an ordinal scoring system to assess the image quality of each arterial segment. Interobserver agreement was determined. RESULTS: The median CSA was 7.3 mm2 in the ulnar and radial artery, 3.2 mm2 in the four common digital arteries, and 1.5 mm2 in five proper digital arteries. The median SNR and CNR of the third common proper arteries were 45.9 and 20.3, respectively. None of the arterial segments were contaminated by venous enhancement. The image quality of arterial segments for both hands was considered as diagnostic in 87.2% of all 1440 segments. An interobserver agreement of 0.67 for both hands was determined for image quality of arterial segments using a five-grade scoring system. Optimized QISS-MRA allows as the first MRA technique the classification of superficial palmar arch (SPA) and deep palmar arch (DPA) variants. 5 new SPA and 6 new DPA variants could be classified using QISS-MRA in comparison with previous studies using CE computed tomography angiography and using fixed cadaver hands. CONCLUSIONS: By using this optimized 2D Cartesian QISS-MRA protocol, contrast agent-free angiography of the wrist and hand arteries provided a high in-plane spatial resolution and an excellent visualization of small digital arteries.


Assuntos
Artérias/diagnóstico por imagem , Meios de Contraste , Mãos/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Punho/diagnóstico por imagem , Adulto , Idoso , Feminino , Mãos/irrigação sanguínea , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Punho/irrigação sanguínea
17.
Radiol Oncol ; 55(2): 158-163, 2021 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-33600679

RESUMO

BACKGROUND: The aim of the study was to assess whether the configuration of primary soft-tissue sarcoma (STS) on MRI correlates with the grade of malignancy. PATIENTS AND METHODS: 71 patients with histologically proven STS were included. Primary STS were examined for configuration, borders, and volume on MRI. The tumors were divided into high-grade (G3), intermediate-grade (G2) and low-grade (G1) STS according to the grading system of the French Federation of Cancer Centers Sarcoma Group (FNCLCC). RESULTS: 30 high-grade, 22 intermediate-grade and 19 low-grade primary STS lesions were identified. High- and intermediate-grade (G3/2) STS significantly most often appeared as polycyclic/multilobulated tumors (p < 0.001 and p = 0.002, respectively). Low-grade (G1) STS mainly showed an ovoid/nodular or streaky configuration (p = 0.008), and well-defined borders. The appearance of high-, intermediate- and low-grade STS with an ovoid/nodular configuration were mainly the same on MRI. All streaky G3/2 sarcoma and 17 of 20 patients with polycyclic/multilobulated G3 sarcoma showed infiltrative borders. High-grade streaky and polycyclic/multilobulated STS are larger in volume, compared to intermediate- and low-grade STS. CONCLUSIONS: Configuration of STS on MRI can indicate the grade of malignancy. Higher-grade (G2/3) STS most often show a polycyclic/multilobulated configuration, while low-grade STS are mainly ovoid/nodular or streaky. Infiltrative behavior might suggest higher-grade STS in streaky and polycyclic/multilobulated STS.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias de Tecidos Moles/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Gradação de Tumores , Neoplasias de Tecidos Moles/patologia , Adulto Jovem
18.
J Thorac Dis ; 13(12): 6769-6778, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35070361

RESUMO

BACKGROUND: It is controversial if the type or the size of aortic dissection is associated with the mortality in patients with acute aortic dissection (AAD) type I or type II according to DeBakey. Due to the pronounced aortic pathology in DeBakey type I compared to DeBakey type II, it is to be expected, that the DeBakey type I is associated with a significant higher morbidity and mortality. But we hypothesize that the current advances in surgical techniques, circulatory management, and postoperative care improve the clinical outcome of patients with DeBakey type I and II. The purpose of this study was to evaluate retrospectively the effect of these parameters on surgical outcome in patients with DeBakey type I and type II in a large cohort study. METHODS: From 2001 to 2019, 395 consecutive patients (34.2% female) underwent surgical aortic repair at our institution. Patients were retrospectively classified into 2 groups: patients with type 1 dissection (group 1: n=309, median age of 62.0 years) and patients with type 2 dissection (group 2: n=86, 67.5 years). Survival was estimated by Kaplan-Meier estimator. Risk factors were analyzed by logistic regression analysis. RESULTS: The patients in group 1 suffered significantly more often from coronary heart disease [43 (13.9%) vs. 20 (23.3%), P=0.036]. Otherwise, there were no significant differences between both groups concerning preoperative risk factors. The median surgical duration (279 vs. 263 min, P=0.026) and the circulatory arrest time (35 vs. 27 min, P<0.001) in group 1 were significantly higher. In a significantly higher number of patients in group 1, the aortic arch was completely replaced (18.4% vs. 1.2%, P<0.001) and a simultaneous coronary artery bypass grafting [18 (5.8%) vs. 11 (12.8%), P=0.028] was performed. The rate of re-thoracotomy [62 (20.1%) vs. 9 (10.5%), P=0.040], of postoperative delirium [66 (21.4%) vs. 9 (10.6%), P=0.024], and of tracheotomy [85 (27.5%) vs. 14 (16.3%), P=0.034] were significantly higher in group 1. Thirty-day mortality was 15.7% and did not differ significantly between both groups (P=0.867), as well as the long-term survival rates (P=0.956). CONCLUSIONS: Due to the pronounced aortic pathology in type I compared to type II, it is to be expected, that the type I is associated with a significant higher morbidity and mortality. DeBakey type I was an independent predictor for 30-day mortality in our study, however, based on our 17-year single center experience there was no difference between the long-term survival in both groups.

20.
J Magn Reson Imaging ; 52(5): 1510-1524, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32537799

RESUMO

BACKGROUND: Free-breathing noncontrast-enhanced (non-CE) magnetic resonance angiography (MRA) techniques are of considerable interest for the diagnosis of acute pulmonary embolism (APE), due to the possibility for repeated examinations, avoidance of side effects from iodine-based contrast agents, and the absence of ionizing radiation exposure as compared to CE-computed tomographic angiography (CTA). PURPOSE: To analyze the clinical performance of free-breathing and electrocardiogram (ECG)-gated radial quiescent-interval slice-selective (QISS)-MRA compared to CE-CTA and to Cartesian balanced steady-state free precession (bSSFP)-MRA. STUDY TYPE: Prospective. SUBJECTS: Thirty patients with confirmed APE and 30 healthy volunteers (HVs). FIELD STRENGTH/SEQUENCE: Radial QISS- and bSSFP-MRA at 1.5T. ASSESSMENT: Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were computed to compare the pulmonary imaging quality between MRA methods. The pulmonary arterial tree was divided into 25 branches and an ordinal scoring system was used to assess the image quality of each pulmonary branch. The clinical performance of the two MRA techniques in accurately assessing APE was evaluated with respect to CE-CTA as the clinical reference standard. STATISTICAL TESTS: Wilcoxon signed-rank and Spearman's correlation tests were performed. Sensitivity and specificity of the MRA techniques were determined using CE-CTA as the clinical reference standard. RESULTS: Thrombus-mimicking artifacts appeared more frequently in lobar and peripheral arteries of patients with Cartesian bSSFP than with radial QISS-MRA (pulmonary trunk: 12.2% vs. 14.0%, P = 0.64; lobar arteries: 35.6% vs. 22.0%, P = 0.005, peripheral arteries: 74.4% vs. 49.0%, P < 0.001). The relative increases in SNR and of CNR provided by radial QISS-MRA with respect to Cartesian bSSFP-MRA were 30-35% (P-values of SNR/CNR, HVs: 0.09/0.09, patients: 0.03/0.02). The image quality of pulmonary arterial branches was considered good to excellent in 77.2% of patients with radial QISS-MRA and in 43.2% with Cartesian bSSFP-MRA (P < 0.0001). The clinical performance of radial QISS-MRA was higher than Cartesian bSSFP-MRA for grading embolism, with a total sensitivity of 86.0% vs. 80.6% and a specificity of 93.3% vs. 84.0%, respectively. DATA CONCLUSION: Radial QISS-MRA is a reliable and safe non-CE angiographic technique with promising clinical potential compared to Cartesian bSSFP-MRA and as an alternative technique to CE-CTA for the diagnosis of APE. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 3.


Assuntos
Angiografia por Ressonância Magnética , Embolia Pulmonar , Angiografia por Tomografia Computadorizada , Meios de Contraste , Humanos , Estudos Prospectivos , Embolia Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA