Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38367698

RESUMO

OBJECTIVES: The HeartMate 3 (Abbott) left ventricular assist device provides substantial improvement in long-term morbidity and mortality in patients with advanced heart failure. The Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study compares thoracotomy-based implantation clinical outcomes with standard median sternotomy. METHODS: We conducted a prospective, multicenter, single-arm study in patients eligible for HeartMate 3 implantation with thoracotomy-based surgical technique (bilateral thoracotomy or partial upper sternotomy with left thoracotomy). The composite primary end point was survival free of disabling stroke (modified Rankin score >3), or reoperation to remove or replace a malfunctioning device, or conversion to median sternotomy at 6-months postimplant (elective transplants were treated as a success). The primary end point (noninferiority, -15% margin) was assessed with >90% power compared with a propensity score-matched cohort (ratio 1:2) derived from the Multi-Center Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 continued access protocol. RESULTS: The study enrolled 102 patients between December 2020 and July 2022 in the thoracotomy-based arm at 23 North American centers. Follow-up concluded in December 2022. In the Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study group, noninferiority criteria was met (absolute between-group difference, -1.2%; Farrington Manning lower 1-sided 95% CI, -9.3%; P < .0025) and event-free survival was not different (85.0% vs 86.2%; hazard ratio, 1.01; 95% CI, 0.58-2.10). Length of stay with thoracotomy-based implant was longer (median, 20 vs 17 days; P = .03). No differences were observed for blood product utilization, adverse events (including right heart failure), functional status, and quality of life between cohorts. CONCLUSIONS: Thoracotomy-based implantation of the HeartMate 3 left ventricular assist device is noninferior to implantation via standard full sternotomy. This study supports thoracotomy-based implantation as an additional standard for surgical implantation of the HeartMate 3 left ventricular assist device.

2.
JACC Heart Fail ; 12(3): 438-447, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38276933

RESUMO

BACKGROUND: Extended criteria donor (ECD) hearts available with donation after brain death (DBD) are underutilized for transplantation due to limitations of cold storage. OBJECTIVES: This study evaluated use of an extracorporeal perfusion system on donor heart utilization and post-transplant outcomes in ECD DBD hearts. METHODS: In this prospective, single-arm, multicenter study, adult heart transplant recipients received ECD hearts using an extracorporeal perfusion system if hearts met study criteria. The primary outcome was a composite of 30-day survival and absence of severe primary graft dysfunction (PGD). Secondary outcomes were donor heart utilization rate, 30-day survival, and incidence of severe PGD. The safety outcome was the mean number of heart graft-related serious adverse events within 30 days. Additional outcomes included survival through 2 years benchmarked to concurrent nonrandomized control subjects. RESULTS: A total of 173 ECD DBD hearts were perfused; 150 (87%) were successfully transplanted; 23 (13%) did not meet study transplantation criteria. At 30 days, 92% of patients had survived and had no severe PGD. The 30-day survival was 97%, and the incidence of severe PGD was 6.7%. The mean number of heart graft-related serious adverse events within 30 days was 0.17 (95% CI: 0.11-0.23). Patient survival was 93%, 89%, and 86% at 6, 12, and 24 months, respectively, and was comparable with concurrent nonrandomized control subjects. CONCLUSIONS: Use of an extracorporeal perfusion system resulted in successfully transplanting 87% of donor hearts with excellent patient survival to 2 years post-transplant and low rates of severe PGD. The ability to safely use ECD DBD hearts could substantially increase the number of heart transplants and expand access to patients in need. (International EXPAND Heart Pivotal Trial [EXPANDHeart]; NCT02323321; Heart EXPAND Continued Access Protocol; NCT03835754).


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Adulto , Humanos , Sobrevivência de Enxerto , Insuficiência Cardíaca/cirurgia , Transplante de Coração/métodos , Preservação de Órgãos/métodos , Estudos Prospectivos , Estudos Retrospectivos , Doadores de Tecidos
5.
J Cardiothorac Surg ; 18(1): 288, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37828522

RESUMO

BACKGROUND: Tricuspid regurgitation(TR) following heart transplantation could adversely affect clinical outcomes. In an effort to reduce the incidence of TR, prophylactic donor heart tricuspid valve annuloplasty has been performed during heart transplantation in our institution. We assessed early and long-term outcomes. METHODS: Between August 2011 and August 2021, 349 patients who underwent prophylactic tricuspid valve annuloplasty were included. Tricuspid valve annuloplasty was performed using the DeVega annuloplasty technique. The clinical outcomes of the interests included complete atrioventricular block requiring pacemaker implantation, the occurrence of significant TR(defined as moderate or greater), and survival. Long-term survival was compared in patients with and without significant TR using the Kaplan-Meier method. The Cox proportional hazards regression with time-dependent covariate analysis was used to see if significant TR affected the long-term survival. RESULTS: There was one patient(0.3%) who required pacemaker implantation for complete atrioventricular block. No patients developed tricuspid valve stenosis that required intervention. Significant TR developed in 31 patients(8.9%) during the follow-up period. The survival rate of patients who developed significant TR was significantly lower than that of those who did not(log rank < 0.01). Significant TR was associated with the long-term mortality(HR2.92, 95%CI 1.47-5.82, p < 0.01). CONCLUSIONS: Prophylactic donor heart tricuspid valve annuloplasty has the potential to reduce the occurrence of significant TR and can be performed safely. The significant TR that developed in patients with prophylactic annuloplasty negatively affected survival and was an independent predictor of long-term mortality.


Assuntos
Bloqueio Atrioventricular , Anuloplastia da Valva Cardíaca , Transplante de Coração , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Valva Tricúspide/cirurgia , Transplante de Coração/efeitos adversos , Estudos Retrospectivos , Doadores de Tecidos , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/etiologia , Anuloplastia da Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento
6.
J Am Coll Cardiol ; 82(9): 771-781, 2023 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-37612008

RESUMO

BACKGROUND: In advanced heart failure patients implanted with a fully magnetically levitated HeartMate 3 (HM3, Abbott) left ventricular assist device (LVAD), it is unknown how preimplant factors and postimplant index hospitalization events influence 5-year mortality in those able to be discharged. OBJECTIVES: The goal was to identify risk predictors of mortality through 5 years among HM3 LVAD recipients conditional on discharge from index hospitalization in the MOMENTUM 3 pivotal trial. METHODS: This analysis evaluated 485 of 515 (94%) patients discharged after implantation of the HM3 LVAD. Preimplant (baseline), implant surgery, and index hospitalization characteristics were analyzed individually, and as multivariable predictors for mortality risk through 5 years. RESULTS: Cumulative 5-year mortality in the cohort (median age: 62 years, 80% male, 65% White, 61% destination therapy due to transplant ineligibility) was 38%. Two preimplant characteristics (elevated blood urea nitrogen and prior coronary artery bypass graft or valve procedure) and 3 postimplant characteristics (hemocompatibility-related adverse events, ventricular arrhythmias, and estimated glomerular filtration rate <60 mL/min/1.73 m2 at discharge) were predictors of 5-year mortality. In 171 of 485 patients (35.3%) without any risk predictors, 5-year mortality was reduced to 22.6% (95% CI: 15.4%-32.7%). Even among those with 1 or more predictors, mortality was <50% at 5 years (45.7% [95% CI: 39.0%-52.8%]). CONCLUSIONS: Long-term survival in successfully discharged HM3 LVAD recipients is largely influenced by clinical events experienced during the index surgical hospitalization in tandem with baseline factors, with mortality of <50% at 5 years. In patients without identified predictors of risk, long-term 5-year mortality is low and rivals that achieved with heart transplantation, even though most were implanted with destination therapy intent. (MOMENTUM 3 IDE Clinical Study Protocol, NCT02224755; MOMENTUM 3 Pivotal Cohort Extended Follow-up PAS, NCT03982979).


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ponte de Artéria Coronária , Insuficiência Cardíaca/terapia , Hospitalização , Alta do Paciente
7.
J Heart Lung Transplant ; 42(11): 1510-1514, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37499959

RESUMO

In June 2021, HVAD System distribution ceased due to observational data demonstrating increased mortality and neurological events compared to another commercial device, and a device malfunction with delay or failure to restart, especially in certain subpopulations. To assess ongoing risk for patients on support following subsequent device recalls, the manufacturer's Intermacs HVAD System 2022 Quarterly Reports were queried to identify mortality and adverse events trends in a contemporary cohort of 3110 primary HVAD implantations since October 2017, stratified by year-of-implant. Mean duration of support was 21 ± 16 months, with 33% alive on original device, 25% transplanted, 6% undergoing device exchange, 4% recovered, and 32% expired. Kaplan-Meier and event-per-patient-year estimates for survival, freedom from device explant, stroke, and pump thrombus were similar across year-of-implant. Following market withdrawal and recent device recalls, there appears to be no increase in mortality, stroke, pump thrombus, or explant for HVAD-supported patients. Quarterly report monitoring is ongoing.

8.
Artigo em Inglês | MEDLINE | ID: mdl-37421402

RESUMO

OBJECTIVES: It remains unknown if the left atrial appendage closure (LAAC) at the time of left ventricular assist device (LVAD) surgery can reduce ischaemic cerebrovascular accidents. METHODS: Consecutive 310 patients who underwent LVAD surgery with HeartMate II or 3 between January 2012 and November 2021 were included in this study. The cohort was divided into 2 groups: patients with LAAC (group A) and without LAAC (group B). We compared the clinical outcomes including the incidence of cerebrovascular accident between 2 groups. RESULTS: Ninety-eight patients were included in group A, and 212 patients in group B. There were no significant differences between 2 groups in age, preoperative CHADS2 score and history of atrial fibrillation. In-hospital mortality did not differ significantly between the 2 groups (group A: 7.1%, group B: 12.3%, P = 0.16). Thirty-seven patients (11.9%) experienced ischaemic cerebrovascular accident (5 patients in group A and 32 patients in group B). The cumulative incidence from ischaemic cerebrovascular accidents in group A (5.3% at 12 months and 5.3% at 36 months) was significantly lower than that in group B (8.2% at 12 months and 16.8% at 36 months; P = 0.017). In a multivariable competing risk analysis, LAAC was associated with reducing ischaemic cerebrovascular accidents (hazard ratio 0.38, 95% confidence interval 0.15-0.97, P = 0.043). CONCLUSIONS: Concomitant LAAC in LVAD surgery can reduce ischaemic cerebrovascular accidents without increasing perioperative mortality and complications.

9.
N Engl J Med ; 388(23): 2121-2131, 2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37285526

RESUMO

BACKGROUND: Data showing the efficacy and safety of the transplantation of hearts obtained from donors after circulatory death as compared with hearts obtained from donors after brain death are limited. METHODS: We conducted a randomized, noninferiority trial in which adult candidates for heart transplantation were assigned in a 3:1 ratio to receive a heart after the circulatory death of the donor or a heart from a donor after brain death if that heart was available first (circulatory-death group) or to receive only a heart that had been preserved with the use of traditional cold storage after the brain death of the donor (brain-death group). The primary end point was the risk-adjusted survival at 6 months in the as-treated circulatory-death group as compared with the brain-death group. The primary safety end point was serious adverse events associated with the heart graft at 30 days after transplantation. RESULTS: A total of 180 patients underwent transplantation; 90 (assigned to the circulatory-death group) received a heart donated after circulatory death and 90 (regardless of group assignment) received a heart donated after brain death. A total of 166 transplant recipients were included in the as-treated primary analysis (80 who received a heart from a circulatory-death donor and 86 who received a heart from a brain-death donor). The risk-adjusted 6-month survival in the as-treated population was 94% (95% confidence interval [CI], 88 to 99) among recipients of a heart from a circulatory-death donor, as compared with 90% (95% CI, 84 to 97) among recipients of a heart from a brain-death donor (least-squares mean difference, -3 percentage points; 90% CI, -10 to 3; P<0.001 for noninferiority [margin, 20 percentage points]). There were no substantial between-group differences in the mean per-patient number of serious adverse events associated with the heart graft at 30 days after transplantation. CONCLUSIONS: In this trial, risk-adjusted survival at 6 months after transplantation with a donor heart that had been reanimated and assessed with the use of extracorporeal nonischemic perfusion after circulatory death was not inferior to that after standard-care transplantation with a donor heart that had been preserved with the use of cold storage after brain death. (Funded by TransMedics; ClinicalTrials.gov number, NCT03831048.).


Assuntos
Morte Encefálica , Transplante de Coração , Obtenção de Tecidos e Órgãos , Adulto , Humanos , Sobrevivência de Enxerto , Preservação de Órgãos , Doadores de Tecidos , Morte , Segurança do Paciente
10.
J Am Coll Cardiol ; 82(1): 70-81, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37380306

RESUMO

Left ventricular assist devices (LVADs) provide lifesaving therapy for patients with advanced heart failure. The recognition of pump thrombosis, stroke, and nonsurgical bleeding as hemocompatibility-related adverse events (HRAEs) led to pump design improvements and reduced adverse event rates. However, continuous flow can predispose patients to right-sided heart failure (RHF) and aortic insufficiency (AI), especially as patients live longer with their device. Given the hemodynamic contributions to AI and RHF, these comorbidities can be classified as hemodynamic-related events (HDREs). Hemodynamic-driven events are time dependent and often manifest later than HRAEs. This review examines the emerging strategies to mitigate HDREs, with a focus on defining best practices for AI and RHF. As we head into the next generation of LVAD technology, it is important to differentiate HDREs from HRAEs so that we can continue to advance the field and improve the true durability of the pump-patient continuum.


Assuntos
Insuficiência da Valva Aórtica , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Coração Auxiliar/efeitos adversos , Hemodinâmica
13.
Artif Organs ; 47(3): 574-581, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36305735

RESUMO

BACKGROUND: Invasive hemodynamic variables obtained from right heart catheterization have been used for risk-stratifying patients with advanced heart failure (HF). However, there is a paucity of data on the prognostic value of invasive hemodynamic variables in patients with left ventricular assist devices (LVAD). We hypothesized that cardiac power output (CPO), cardiac power efficiency (CPE), and left ventricular stroke work index (LVSWI) can serve as prognostic markers in patients with LVADs. METHODS: Baseline hemodynamic data from patients who had LVAD ramp studies at our institution from 4/2014 to 7/2018 were prospectively collected, from which advanced hemodynamic variables (CPO, CPE, and LVSWI) were retrospectively analyzed. Univariate and multivariable analyses were performed for hemocompatibility-related adverse events (HRAE), HF admissions, and mortality. RESULTS: Ninety-one participants (age 61 ± 11 years, 34% women, 40% Black or African American, and 38% ischemic cardiomyopathy) were analyzed. Low CPE was significantly associated with mortality (HR 2.42, 95% CI 1.02-5.74, p = 0.045) in univariate analysis and Kaplan-Meier analysis (p = 0.04). Low LVSWI was significantly associated with mortality (HR 2.13, 95% CI 1.09-4.17, p = 0.03) in univariate analysis and Kaplan-Meier analysis (p = 0.02). CPO was not associated with mortality. CPO, CPE, and LVSWI were not associated with HRAE or HF admissions. CONCLUSIONS: Advanced hemodynamic variables can serve as prognostic indicators for patients with LVADs. Low CPE and LVSWI are prognostic for higher mortality, but no variables were associated with HF admissions or HRAEs.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Prognóstico , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Hemodinâmica , Débito Cardíaco
14.
J Thorac Cardiovasc Surg ; 166(6): 1684-1694.e18, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35643769

RESUMO

BACKGROUND: Correction of valvular disease is often undertaken during left ventricular assist device (LVAD) implantation with uncertain benefit. We analyzed clinical outcomes with HeartMate 3 (HM3; Abbott) LVAD implantation in those with various concurrent valve procedures (HM3+VP) with those with an isolated LVAD implant (HM3 alone). METHODS: The study included 2200 patients with HM3 implanted within the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) trial portfolio who underwent 820 concurrent procedures among which 466 (21.8%) were HM3+VP. VPs included 101 aortic, 61 mitral, 163 tricuspid; 85 patients had multiple VPs. Perioperative complications, major adverse events, and survival were analyzed. RESULTS: Patients who underwent HM3+VP had higher-acuity Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profiles (1-2: 41% vs 31%) compared with no VPs (P < .05). The cardiopulmonary bypass time (124 vs 76 minutes; P < .0001) and hospital length of stay (20 vs 18 days; P < .0001) were longer in HM3+VP. A higher incidence of stroke (4.9% vs 2.4%), bleeding (33.9% vs 23.8%), and right heart failure (41.5% vs 29.6%) was noted in HM3+VP at 0 to 30 days (P < .01), with no difference in 30-day mortality (3.9% vs 3.3%) or 2-year survival (81.7% vs 80.8%). Analysis of individual VP showed no differences in survival compared to HM3 alone. No differences were noted among patients with either significant mitral (moderate or worse) or tricuspid (moderate or worse) regurgitation with or without corrective surgery. CONCLUSIONS: Concurrent VPs, commonly performed during LVAD implantation, are associated with increased morbidity during the index hospitalization, with no effect on short- and long-term survival. There is sufficient equipoise to consider a randomized trial on the benefit of commonly performed VPs (such as mitral or tricuspid regurgitation correction), during LVAD implantation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Procedimentos Cirúrgicos Torácicos , Humanos , Catéteres , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Estudos Multicêntricos como Assunto
15.
J Card Surg ; 37(12): 5011-5018, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36349705

RESUMO

BACKGROUND: The Organ Care System (OCS) is a revolutionary ex vivo organ perfusion technology that can potentially expand the organ retrieval range. The OCS Lung device uses packed red blood cells (pRBC) with a proprietary solution. We report the ability to reduce blood waste during this procedure by using a thermal packaging solution in conjunction with the OCS platform. METHODS: We retrospectively reviewed all OCS Lung recoveries performed by our recovery team, using pRBCfrom May 2019 to January 2021. Initially, units were stored using passive refrigeration with the Performance cooler at a temperature range of 1-6°C for 4 h. Subsequently, thermal control technology with the ProMed cooler was utilized to maintain the same temperature range for 72 h. RESULTS: Twenty-three recoveries were initiated with 63 pRBC. The Performance cooler was used for 8, while the ProMed cooler for 13. 37.5% of pRBC transported with the Performance cooler was used within the validated time range, while 25.0% were used beyond the validated time range based on clinical judgment. In addition, 37.5% of pRBC transported with the Performance cooler were returned to the institution after canceled recoveries with an estimated loss of $1800; the ProMed cooler had no wastage. CONCLUSIONS: This study showed that using an advanced thermal packaging solution facilitates proper storage of pRBC and represents an advancement for extended donor lung preservation. The elimination of blood wastage in this initial study portends ongoing benefits for the limited blood supply and reduced cost.


Assuntos
Transplante de Pulmão , Preservação de Órgãos , Humanos , Preservação de Órgãos/métodos , Estudos Retrospectivos , Pulmão , Circulação Extracorpórea , Transplante de Pulmão/métodos , Perfusão/métodos
16.
JAMA ; 328(12): 1233-1242, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-36074476

RESUMO

Importance: Although durable left ventricular assist device (LVAD) therapy has emerged as an important treatment option for patients with advanced heart failure refractory to pharmacological support, outcomes, including survival, beyond 2 years remain poorly characterized. Objective: To report the composite end point of survival to transplant, recovery, or LVAD support free of debilitating stroke (Modified Rankin Scale score >3) or reoperation to replace the pump 5 years after the implant in participants who received the fully magnetically levitated centrifugal-flow HeartMate 3 or axial-flow HeartMate II LVAD in the MOMENTUM 3 randomized trial and were still receiving LVAD therapy at the 2-year follow-up. Design, Setting, and Participants: This observational study was a 5-year follow-up of the MOMENTUM 3 trial, conducted in 69 US centers, that demonstrated superiority of the centrifugal-flow LVAD to the axial-flow pump with respect to survival to transplant, recovery, or LVAD support free of debilitating stroke or reoperation to replace the pump at 2 years. A total of 295 patients were enrolled between June 2019 to April 2021 in the extended-phase study, with 5-year follow-up completed in September 2021. Exposures: Of 1020 patients in the investigational device exemption per-protocol population, 536 were still receiving LVAD support at 2 years, of whom 289 received the centrifugal-flow pump and 247 received the axial-flow pump. Main Outcomes and Measures: There were 10 end points evaluated at 5 years in the per-protocol population, including a composite of survival to transplant, recovery, or LVAD support free of debilitating stroke or reoperation to replace the pump between the centrifugal-flow and axial-flow pump groups and overall survival between the 2 groups. Results: A total of 477 patients (295 enrolled and 182 provided limited data) of 536 patients still receiving LVAD support at 2 years contributed to the extended-phase analysis (median age, 62 y; 86 [18%] women). The 5-year Kaplan-Meier estimate of survival to transplant, recovery, or LVAD support free of debilitating stroke or reoperation to replace the pump in the centrifugal-flow vs axial-flow group was 54.0% vs 29.7% (hazard ratio, 0.55 [95% CI, 0.45-0.67]; P < .001). Overall Kaplan-Meier survival was 58.4% in the centrifugal-flow group vs 43.7% in the axial-flow group (hazard ratio, 0.72 [95% CI, 0.58-0.89]; P = .003). Serious adverse events of stroke, bleeding, and pump thrombosis were less frequent in the centrifugal-flow pump group. Conclusions and Relevance: In this observational follow-up study of patients from the MOMENTUM 3 randomized trial, per-protocol analyses found that receipt of a fully magnetically levitated centrifugal-flow LVAD vs axial-flow LVAD was associated with a better composite outcome and higher likelihood of overall survival at 5 years. These findings support the use of the fully magnetically levitated LVAD. Trial Registration: ClinicalTrials.gov Identifier: NCT02224755 and NCT03982979.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Feminino , Seguimentos , Coração Auxiliar/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
18.
Heart Vessels ; 37(12): 1995-2001, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35794489

RESUMO

OBJECTIVES: The purpose of this study is to investigate the early and late outcomes of axillary intra-aortic balloon pump (IABP) implantation as a bridge to heart transplantation, comparing the grafted technique with the percutaneous technique. METHODS: Between July 2009 and January 2020, 163 patients underwent an axillary IABP insertion as a bridge to heart transplantation. Among them, 97 patients underwent axillary IABP implantation through a graft sutured onto the axillary artery (Group A) and 66 patients underwent percutaneously (Group B). Propensity matching identified 53 matched pairs for analysis (C-statistics 0.741). The primary outcomes of interest included IABP-related complications, success rate of a bridge to transplantation, in-hospital mortality, and late survival. RESULTS: In the propensity-score matched cohort, there were no significant differences in the baseline characteristics between the two groups. The operation time was significantly longer in Group A than in Group B (141.5 ± 38.3 min vs 42.7 ± 19.3 min, p < 0.01). The complication rates including stroke, re-exploration for bleeding, and aortic event were not significantly different between Group A and B. However, Group A required more transfusion and re-exploration for bleeding. The success rate of a bridge to transplantation was similar between Group A (47/53, 88.7%) and Group B (47/53, 88.7%). There were no significant differences in in-hospital mortality and late survival between two groups. CONCLUSION: In the propensity score matching analysis, there were not any significant differences between the two groups in IABP-related complications, in-hospital mortality, and late survival. The percutaneous technique provided a shorter operation time and less requirement of transfusion and re-exploration for bleeding compared to the grafted technique. The percutaneous technique might be favorable when feasible.


Assuntos
Transplante de Coração , Coração Auxiliar , Humanos , Pontuação de Propensão , Estudos Retrospectivos , Balão Intra-Aórtico/efeitos adversos , Resultado do Tratamento
19.
J Thorac Cardiovasc Surg ; 164(4): 1120-1137.e2, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35624053

RESUMO

OBJECTIVES: Six months after withdrawal of the HeartWare HVAD System (HVAD; Medtronic) from sale, approximately 4000 patients continue ongoing support with this device. In light of the diminishing experience, this global consensus document summarizes key management recommendations. METHODS: International experts with experience in the management of patients with ongoing HVAD support were invited to summarize key aspects of patient and pump management and highlight differences in the current HeartMate 3 (Abbott Laboratories) ventricular assist device. Clinicians from high-implanting HVAD sites reviewed current literature and reported experience to generate a consensus statement. RESULTS: Specific guidelines to assist in the management of ongoing HVAD patients are developed. Key management protocols and helpful techniques developed from experienced clinicians are combined into a short guideline document. As experience with HeartMate 3 increases, key differences in approach to management are highlighted, where appropriate. CONCLUSIONS: With decreasing worldwide experience in the ongoing management of HVAD-supported patients, this consensus guideline provides a summary of best practice techniques from international centers. Differences in HeartMate 3 management are highlighted.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Estudos Retrospectivos
20.
Ann Thorac Surg ; 114(6): 2262-2269, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35452663

RESUMO

BACKGROUND: Outcomes in patients with smaller body size after HeartMate 3 left ventricular assist device (HM3) implantation are not well characterized. We sought to evaluate outcomes in smaller vs larger body surface area (BSA) patients in the MOMENTUM 3 pivotal trial and its Continued Access Protocol cohort. METHODS: The analysis cohort included 1015 HM3 patients divided into 2 groups: BSA ≤1.70 m2 (small patients, n = 82) and BSA >1.70 m2 (large patients, n = 933). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or to remove a malfunctioning device. Adverse events were compared between groups. RESULTS: Smaller patients were more frequently women (56.1% vs 17.7%; P < .001) and had lower prevalence of diabetes (28.1% vs 43.9%; P = .005) and hypertension (51.2% vs 71.9%; P < .001), larger median indexed LVEDD (normalized by BSA, 40 vs 33 mm/m2; P < .001), and lower median serum creatinine concentration (1.1 vs 1.3 mg/dL; P < .001). The proportion of patients achieving the composite end point at 2 years was 77% in both groups (adjusted hazard ratio, 1.14; 95% CI, 0.68-1.91; P = .62). Two-year adverse event rates were also similar between groups except for sepsis (6.1% vs 14.9%; P = .029) and cardiac arrhythmias (24.4% vs 35.3%; P = .005), which were higher in the larger patients. CONCLUSIONS: Outcomes after HM3 implantation were comparable between small and large patients. Smaller body size should not be used to deny HM3 implantation in patients who are otherwise suitable candidates for durable mechanical circulatory support.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Feminino , Humanos , Tamanho Corporal , Insuficiência Cardíaca/etiologia , Coração Auxiliar/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA