Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Lancet Reg Health Am ; 11: None, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35865654

RESUMO

Background: In January 2018, Ecuador changed its routine immunization schedule by replacing one full dose of inactivated poliovirus vaccine (IPV) administered intramuscularly at 2 months of age with two doses of fractional IPV (1/5th of full dose, fIPV) administered intradermally at 2 and 4 months of age; and bivalent oral poliovirus vaccine (serotypes 1 and 3, bOPV) continues to be used. We compared seroprevalence and titres of polio antibodies achieved by the past and the current immunization schedules. Methods: This was a cross-sectional serological survey in children in Ecuador who received bOPV and either one IPV dose in 2017 or two fIPV doses in 2018. One blood sample was collected between October 2020 and March 2021 and analysed for presence of poliovirus neutralizing antibodies at CDC, Atlanta by microneutralization assay. Findings: We obtained 321 analysable samples from 329 (97·6%) enrolled children (160 received IPV and 161 fIPV). For serotype 2, seroprevalence was 50·0% (CI95%= 44·2-55·8%) for IPV and 83·2% (CI95%=78·5-87·1%) for fIPV recipients (p<0·001). Median antibody titers for serotype 2 were significantly lower for IPV than for fIPV recipients (3·0, CI95%= 3 - 3·5 vs. 4·8, CI95%= 4·5 - 5·2, p<0·001). Seroprevalence for serotypes 1 and 3 was above 90% and was not significantly different between IPV and fIPV recipients. Interpretation: Ecuador achieved significantly better poliovirus serotype 2 immunogenicity with two fIPV doses than with one IPV dose, while preserving vaccine supply and reducing costs. Our data provide further evidence that fIPV is a beneficial and potentially a cost-effective option in polio immunization. Funding: WHO obtained funds for the study from Rotary International.

2.
Europace ; 24(11): 1788-1799, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-35851611

RESUMO

AIMS: To determine the spectral dynamics of early spontaneous polymorphic ventricular tachycardia and ventricular fibrillation (PVT/VF) in humans. METHODS AND RESULTS: Fifty-eight self-terminated and 173 shock-terminated episodes of spontaneously initiated PVT/VF recorded by Medtronic implanted cardiac defibrillators (ICDs) in 87 patients with various cardiac pathologies were analyzed by short fast Fourier transform of shifting segments to determine the dynamics of dominant frequency (DF) and regularity index (RI). The progression in the intensity of DF and RI accumulations further quantified the time course of spectral characteristics of the episodes. Episodes of self-terminated PVT/VF lasted 8.6 s [95% confidence interval (CI): 8.1-9.1] and shock-terminated lasted 13.9 s (13.6-14.3) (P < 0.001). Recordings from patients with primarily electrical pathologies displayed higher DF and RI values than those from patients with primarily structural pathologies (P < 0.05) independently of ventricular function or antiarrhythmic drug therapy. Regardless of the underlying pathology, the average DF and RI intensities were lower in self-terminated than shock-terminated episodes [DF: 3.67 (4.04-4.58) vs. 4.32 (3.46-3.93) Hz, P < 0.001; RI: 0.53 (0.48-0.56) vs. 0.63 (0.60-0.65), P < 0.001]. In a multivariate analysis controlled by the type of pathology and clinical variables, regularity remained an independent predictor of self-termination [hazard ratio: 0.954 (0.928-0.980)]. Receiver operating characteristic (ROC) curve analysis of DF and RI intensities demonstrated increased predictability for self-termination in time with 95% CI above the 0.5 cut-off limit at about t = 8.6 s and t = 6.95 s, respectively. CONCLUSION: Consistent with the notion that fast organized sources maintain PVT/VF in humans, reduction of frequency and regularity correlates with early self-termination. Our findings might help generate ICD methods aiming to reduce inappropriate shock deliveries.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Arritmias Cardíacas , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA