Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Artif Organs ; 46(4): 705-709, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35080023

RESUMO

BACKGROUND: Thrombotic complications continue to pose challenges to patients on left ventricular assist device (LVAD) support. The Hoplon system was developed to administer catheter-based lytic therapy with a novel approach to embolic protection. METHODS: Two porcine non-survival surgeries were performed in which off-pump LVAD insertion was followed by injection of thrombus into the impeller, isolation of the pump using the Hoplon system, and administration of lytic therapy to the pump chamber. Successful thrombus resolution was confirmed by pathological examination of the LVAD and brain tissue after animal sacrifice. RESULTS: Limitations of the prototype design resulted in the extrusion of thrombus from around the catheter in the first animal. Subsequent device modifications resulted in the resolution of LVAD thrombus as confirmed on removal and examination of the pump. Pathological examination of the brain tissue revealed the absence of any embolic or hemorrhagic complications. CONCLUSIONS: Early animal studies suggest feasibility in restoring function to an LVAD while at the same time preventing cerebroembolic events using the Hoplon system.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Trombose , Animais , Catéteres/efeitos adversos , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Suínos , Trombose/etiologia , Trombose/prevenção & controle , Resultado do Tratamento
2.
J Cardiol Cases ; 24(3): 140-143, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34466179

RESUMO

Patent foramen ovale (PFO) closure is indicated in cryptogenic stroke. Percutaneous PFO closure is both feasible and highly efficacious with low incidence of device-related complications. When complications occur, they are usually discovered within 6 weeks of device deployment. We describe the case of a partially embolised and fractured Gore Helex Septal Occluder device recognised nearly 9 years after placement requiring surgical explant. .

3.
JACC Cardiovasc Interv ; 14(8): 830-845, 2021 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-33888229

RESUMO

OBJECTIVES: The aim of this study was to evaluate 1-year outcomes of valve-in-mitral annular calcification (ViMAC) in the MITRAL (Mitral Implantation of Transcatheter Valves) trial. BACKGROUND: The MITRAL trial is the first prospective study evaluating the feasibility of ViMAC using balloon-expandable aortic transcatheter heart valves. METHODS: A multicenter prospective study was conducted, enrolling high-risk surgical patients with severe mitral annular calcification and symptomatic severe mitral valve dysfunction at 13 U.S. sites. RESULTS: Between February 2015 and December 2017, 31 patients were enrolled (median age 74.5 years [interquartile range (IQR): 71.3 to 81.0 years], 71% women, median Society of Thoracic Surgeons score 6.3% [IQR: 5.0% to 8.8%], 87.1% in New York Heart Association functional class III or IV). Access was transatrial (48.4%), transseptal (48.4%), or transapical (3.2%). Technical success was 74.2%. Left ventricular outflow tract obstruction (LVOTO) with hemodynamic compromise occurred in 3 patients (transatrial, n = 1; transseptal, n = 1; transapical, n = 1). After LVOTO occurred in the first 2 patients, pre-emptive alcohol septal ablation was implemented to decrease risk in high-risk patients. No intraprocedural deaths or conversions to open heart surgery occurred during the index procedures. All-cause mortality at 30 days was 16.7% (transatrial, 21.4%; transseptal, 6.7%; transapical, 100% [n = 1]; p = 0.33) and at 1 year was 34.5% (transatrial, 38.5%; transseptal, 26.7%; p = 0.69). At 1-year follow-up, 83.3% of patients were in New York Heart Association functional class I or II, the median mean mitral valve gradient was 6.1 mm Hg (IQR: 5.6 to 7.1 mm Hg), and all patients had ≤1+ mitral regurgitation. CONCLUSIONS: At 1 year, ViMAC was associated with symptom improvement and stable transcatheter heart valve performance. Pre-emptive alcohol septal ablation may prevent transcatheter mitral valve replacement-induced LVOTO in patients at risk. Thirty-day mortality of patients treated via transseptal access was lower than predicted by the Society of Thoracic Surgeons score. Further studies are needed to evaluate safety and efficacy of ViMAC.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
4.
JACC Cardiovasc Interv ; 14(8): 859-872, 2021 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-33888231

RESUMO

OBJECTIVES: The aim of this study was to assess 1-year clinical outcomes among high-risk patients with failed surgical mitral bioprostheses who underwent transseptal mitral valve-in-valve (MViV) with the SAPIEN 3 aortic transcatheter heart valve (THV) in the MITRAL (Mitral Implantation of Transcatheter Valves) trial. BACKGROUND: The MITRAL trial is the first prospective study evaluating transseptal MViV with the SAPIEN 3 aortic THV in high-risk patients with failed surgical mitral bioprostheses. METHODS: High-risk patients with symptomatic moderate to severe or severe mitral regurgitation (MR) or severe mitral stenosis due to failed surgical mitral bioprostheses were prospectively enrolled. The primary safety endpoint was technical success. The primary THV performance endpoint was absence of MR grade ≥2+ or mean mitral valve gradient ≥10 mm Hg (30 days and 1 year). Secondary endpoints included procedural success and all-cause mortality (30 days and 1 year). RESULTS: Thirty patients were enrolled between July 2016 and October 2017 (median age 77.5 years [interquartile range (IQR): 70.3 to 82.8 years], 63.3% women, median Society of Thoracic Surgeons score 9.4% [IQR: 5.8% to 12.0%], 80% in New York Heart Association functional class III or IV). The technical success rate was 100%. The primary performance endpoint in survivors was achieved in 96.6% (28 of 29) at 30 days and 82.8% (24 of 29) at 1 year. Thirty-day all-cause mortality was 3.3% and was unchanged at 1 year. The only death was due to airway obstruction after swallowing several pills simultaneously 29 days post-MViV. At 1-year follow-up, 89.3% of patients were in New York Heart Association functional class I or II, the median mean mitral valve gradient was 6.6 mm Hg (interquartile range: 5.5 to 8.9 mm Hg), and all patients had MR grade ≤1+. CONCLUSIONS: Transseptal MViV in high-risk patients was associated with 100% technical success, low procedural complication rates, and very low mortality at 1 year. The vast majority of patients experienced significant symptom alleviation, and THV performance remained stable at 1 year.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
5.
JACC Cardiovasc Interv ; 14(8): 846-858, 2021 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-33888230

RESUMO

OBJECTIVES: The authors report 1-year outcomes of high-risk patients with failed surgical annuloplasty rings undergoing transseptal mitral valve-in-ring (MViR) with the SAPIEN 3 aortic transcatheter heart valve (THV). BACKGROUND: The MITRAL (Mitral Implantation of Transcatheter Valves) trial is the first prospective study evaluating transseptal MViR with the SAPIEN 3 aortic THV in high-risk patients with failed surgical annuloplasty rings. METHODS: Prospective enrollment of high-risk patients with symptomatic moderate to severe or severe mitral regurgitation (MR) or severe mitral stenosis and failed annuloplasty rings at 13 U.S. sites. The primary safety endpoint was technical success. The primary THV performance endpoint was absence of MR grade ≥2+ or mean mitral valve gradient ≥10 mm Hg (30 days and 1 year). Secondary endpoints included procedural success and all-cause mortality (30 days and 1 year). RESULTS: Thirty patients were enrolled between January 2016 and October 2017 (median age 71.5 years [interquartile range: 67.0 to 76.8 years], 36.7% women, median Society of Thoracic Surgeons score 7.6% [interquartile range: 5.1% to 11.8%], 76.7% in New York Heart Association functional class III or IV). Technical success was 66.7% (driven primarily by need for a second valve in 6 patients). There was no intraprocedural mortality or conversion to surgery. The primary performance endpoint was achieved in 85.7% of survivors at 30 days (24 of 28) and 89.5% of patients alive at 1 year with echocardiographic data available (17 of 19). All-cause mortality at 30 days was 6.7% and at 1 year was 23.3%. Among survivors at 1-year follow-up, 84.2% were in New York Heart Association functional class I or II, the median mean mitral valve gradient was 6.0 mm Hg (interquartile range: 4.7 to 7.3 mm Hg), and all had ≤1+ MR. CONCLUSIONS: Transseptal MViR was associated with a 30-day mortality rate lower than predicted by the Society of Thoracic Surgeons score. At 1 year, transseptal MViR was associated with symptom improvement and stable THV performance.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Idoso , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
6.
J Am Coll Cardiol ; 77(16): 1994-2003, 2021 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-33888249

RESUMO

BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic has impacted many aspects of ST-segment elevation myocardial infarction (STEMI) care, including timely access to primary percutaneous coronary intervention (PPCI). OBJECTIVES: The goal of the NACMI (North American COVID-19 and STEMI) registry is to describe demographic characteristics, management strategies, and outcomes of COVID-19 patients with STEMI. METHODS: A prospective, ongoing observational registry was created under the guidance of 3 cardiology societies. STEMI patients with confirmed COVID+ (group 1) or suspected (person under investigation [PUI]) (group 2) COVID-19 infection were included. A group of age- and sex-matched STEMI patients (matched to COVID+ patients in a 2:1 ratio) treated in the pre-COVID era (2015 to 2019) serves as the control group for comparison of treatment strategies and outcomes (group 3). The primary outcome was a composite of in-hospital death, stroke, recurrent myocardial infarction, or repeat unplanned revascularization. RESULTS: As of December 6, 2020, 1,185 patients were included in the NACMI registry (230 COVID+ patients, 495 PUIs, and 460 control patients). COVID+ patients were more likely to have minority ethnicity (Hispanic 23%, Black 24%) and had a higher prevalence of diabetes mellitus (46%) (all p < 0.001 relative to PUIs). COVID+ patients were more likely to present with cardiogenic shock (18%) but were less likely to receive invasive angiography (78%) (all p < 0.001 relative to control patients). Among COVID+ patients who received angiography, 71% received PPCI and 20% received medical therapy (both p < 0.001 relative to control patients). The primary outcome occurred in 36% of COVID+ patients, 13% of PUIs, and 5% of control patients (p < 0.001 relative to control patients). CONCLUSIONS: COVID+ patients with STEMI represent a high-risk group of patients with unique demographic and clinical characteristics. PPCI is feasible and remains the predominant reperfusion strategy, supporting current recommendations.


Assuntos
COVID-19/epidemiologia , Intervenção Coronária Percutânea/estatística & dados numéricos , SARS-CoV-2 , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Canadá/epidemiologia , Feminino , Mortalidade Hospitalar , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte/epidemiologia , Estudos Prospectivos , Recidiva , Sistema de Registros/estatística & dados numéricos , Reoperação/estatística & dados numéricos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Estados Unidos/epidemiologia , Adulto Jovem
7.
JACC Cardiovasc Imaging ; 13(9): 1945-1957, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32417332

RESUMO

OBJECTIVES: This study aims to establish a computed tomography (CT)-based scoring system for grading mitral annular calcification (MAC) severity and potentially aid in predicting valve embolization during transcatheter mitral valve (MV) replacement using balloon-expandable aortic transcatheter heart valves. BACKGROUND: Transcatheter MV replacement is emerging as an alternative treatment for patients with severe MAC who are not surgical candidates. Although cardiac CT is the imaging modality of choice in the evaluation of candidates for valve-in-MAC (ViMAC), a standardized grading system to quantify MAC severity has not been established. METHODS: We performed a multicenter retrospective review of cardiac CT and clinical outcomes of patients undergoing ViMAC. A CT-based MAC score was created using the following features: average calcium thickness (mm), degrees of annulus circumference involved, calcification at one or both fibrous trigones, and calcification of one or both leaflets. Features were assigned points according to severity (total maximum score = 10) and severity grade was assigned based on total points (mild ≤3, moderate 4 to 6, and severe ≥7 points). The association between MAC score and device migration/embolization was evaluated. RESULTS: Of 117 patients in the TMVR in MAC registry, 87 had baseline cardiac CT of adequate quality. Of these, 15 were treated with transatrial access and were not included. The total cohort included 72 (trans-septal = 37, transapical = 35). Mean patient age was 74 ± 12 years, 66.7% were female, and the mean Society of Thoracic Surgery risk score was 15.4 ± 10.5%. The mean MAC score was 7.7 ± 1.4. Embolization/migration rates were lower in higher scores: Patients with a MAC score of 7 had valve embolization/migration rate of 12.5%, MAC score ≥8 had a rate of 8.7%, and a MAC score of ≥9 had zero (p = 0.023). Patients with a MAC score of ≤6 had 60% embolization/migration rate versus 9.7% in patients with a MAC score ≥7 (p < 0.001). In multivariable analysis, a MAC score ≤6 was in independent predictor of valve embolization/migration (odds ratio [OR]: 5.86 [95% CI: 1.00 to 34.26]; p = 0.049). CONCLUSIONS: This cardiac CT-based score provides a systematic method to grade MAC severity which may assist in predicting valve embolization/migration during trans-septal or transapical ViMAC procedures.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
8.
Circ Cardiovasc Interv ; 13(3): e008425, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32138529

RESUMO

BACKGROUND: Transcatheter mitral valve replacement using aortic transcatheter heart valves has recently become an alternative for patients with degenerated mitral bioprostheses, failed surgical repairs with annuloplasty rings or severe mitral annular calcification who are poor surgical candidates. Outcomes of these procedures are collected in the Society of Thoracic Surgeons/American College of Cardiology/Transcatheter Valve Therapy Registry. A comprehensive analysis of mitral valve-in-valve (MViV), mitral valve-in-ring (MViR), and valve-in-mitral annular calcification (ViMAC) outcomes has not been performed. We sought to evaluate short-term outcomes of early experience with MViV, MViR, and ViMAC in the United States. METHODS: Retrospective analysis of data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. RESULTS: Nine hundred three high-risk patients (median Society of Thoracic Surgeons score 10%) underwent MViV (n=680), MViR (n=123), or ViMAC (n=100) between March 2013 and June 2017 at 172 hospitals. Median age was 75 years, 59.2% female. Technical and procedural success were higher in MViV. Left ventricular outflow tract obstruction occurred more frequently with ViMAC (ViMAC=10%, MViR=4.9%, MViV=0.7%; P<0.001). In-hospital mortality (MViV=6.3%, MViR=9%, ViMAC=18%; P=0.004) and 30-day mortality (MViV=8.1%, MViR=11.5%, ViMAC=21.8%; P=0.003) were higher in ViMAC. At 30-day follow-up, median mean mitral valve gradient was 7 mm Hg, most patients (96.7%) had mitral regurgitation grade ≤1 (+) and were in New York Heart Association class I to II (81.7%). CONCLUSIONS: MViV using aortic balloon-expandable transcatheter heart valves is associated with a low complication rate, a 30-day mortality lower than predicted by the Society of Thoracic Surgeons score, and superior short-term outcomes than MViR and ViMAC. At 30 days, patients in all groups experienced improvement of symptoms, and valve performance remained stable. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02245763.


Assuntos
Calcinose/cirurgia , Cateterismo Cardíaco/instrumentação , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/instrumentação , Valva Mitral/cirurgia , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Calcinose/etiologia , Calcinose/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Feminino , Doenças das Valvas Cardíacas/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Masculino , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/mortalidade , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
10.
JTCVS Tech ; 3: 263-264, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34317894
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA