Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Echocardiography ; 40(6): 562-567, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37212377

RESUMO

BACKGROUND: For severe mitral valve (MV) degenerative disease, repair is recommended. Prediction of repair complexity and referral to high volume centers can increase rates of successful repair. This study sought to demonstrate that TEE is a feasible imaging modality to predict the complexity of surgical MV repair. METHODS: Two hundred TEE examinations of patients who underwent MV repair (2009-2011) were retrospectively reviewed and scored by two cardiac anesthesiologists. TEE scores were compared to surgical complexity scores, which were previously assigned based on published methods. Kappa values were reported for the agreement of TEE and surgical scores. McNemar's tests were used to test the homogeneity of the marginal probabilities of different scoring categories. RESULTS: TEE scores were slightly lower (2[1,3]) than surgical scores (3[1,4]). The agreement was 66% between the scoring methods, with a moderate kappa (.46). Using surgical scores as the gold standard, 70%, 71%, and 46% of simple, intermediate and complex surgical scores, respectively, were correctly scored by TEE. P1, P2, P3, and A2 prolapse were easiest to identify with TEE and had the highest agreement with surgical scoring (P1 agreement 79% with kappa .55, P2 96% [kappa .8], P3 77% [kappa .51], A2 88% [kappa .6]). The lowest agreement between the two scores occurred with A1 prolapse (kappa .05) and posteromedial commissure prolapse (kappa .14). In the presence of significant disagreement, TEE scores were more likely to be of higher complexity than surgical. McNemar's test was significant for prolapse of P1 (p = .005), A1 (p = .025), A2 (p = .041), and the posteromedial commissure (p < .0001). CONCLUSION: TEE-based scoring is feasible for prediction of the complexity of MV surgical repair, thus allowing for preoperative stratification.


Assuntos
Ecocardiografia Tridimensional , Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Ecocardiografia Transesofagiana/métodos , Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Estudos Retrospectivos , Ecocardiografia Tridimensional/métodos , Insuficiência da Valva Mitral/cirurgia , Prolapso
3.
Nat Rev Cardiol ; 20(4): 263-277, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36357709

RESUMO

Originally intended for life-saving salvage therapy, the use of temporary mechanical circulatory support (MCS) devices has become increasingly widespread in a variety of clinical settings in the contemporary era. Their use as a short-term, prophylactic support vehicle has expanded to include procedures in the catheterization laboratory, electrophysiology suite, operating room and intensive care unit. Accordingly, MCS device design and technology continue to develop at a rapid pace. In this Review, we describe the functionality, indications, management and complications associated with temporary MCS, together with scenario-specific utilization, goal-directed development and bioengineering of future devices. We address various considerations for the use of temporary MCS devices in both prophylactic and rescue scenarios, with input from stakeholders from various cardiovascular specialties, including interventional and heart failure cardiology, electrophysiology, cardiothoracic anaesthesiology, critical care and cardiac surgery.


Assuntos
Cardiologia , Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Insuficiência Cardíaca/cirurgia , Coração , Choque Cardiogênico/terapia
5.
J Thorac Cardiovasc Surg ; 163(5): 1818-1825, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-32891452

RESUMO

OBJECTIVE: The leadless cardiac pacemaker is typically implanted percutaneously and has been widely used for patients who have already undergone valve surgery. We sought to determine the feasibility and safety of implanting the leadless pacemaker under direct visualization during valve surgery. METHODS: We performed a retrospective analysis of consecutive adult patients (n = 15) who underwent implantation of a leadless pacemaker under direct visualization at the time of valve surgery. Indications for single-chamber pacing were sick sinus syndrome with pauses (53.3%), atrial fibrillation with slow ventricular rates (13.3%) or complete heart block (6.6%), and elevated risk for postoperative heart block (26.6%). Leadless pacemaker performance and pacing percentage were assessed. RESULTS: Patients' age was 67.5 ± 17 years, 6 patients (40%) were male, and 14 patients (93%) had atrial fibrillation. Isolated tricuspid valve replacement was performed in 5 patients (33.3%), and the remainder underwent multivalve surgery that included concomitant tricuspid valve repair/replacement. In 93% of the patients (n = 14), the immediate post-cardiopulmonary bypass pacing thresholds were normal (≤2.0 V at 0.24 ms) and normalized in the remaining patient by the next morning. The impedance/sensing values were normal and stable through follow-up (151 ± 119 days) in all patients. Reliable leadless pacemaker performance allowed for deferral of temporary epicardial wires in 11 patients (73%). There were no procedural complications or device malfunction. CONCLUSIONS: Leadless cardiac pacemaker implantation during valve surgery is feasible and safe. This hybrid approach to pacing may simplify the perioperative management of patients undergoing valve surgery who have an indication for single-chamber pacing.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
6.
J Anesth ; 35(3): 366-373, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33006071

RESUMO

In March 2020, the New York City metropolitan area became the epicenter of the United States' SARS-CoV-2 pandemic and the surge of new cases threatened to overwhelm the area's hospital systems. This article describes how an anesthesiology department at a large urban academic hospital rapidly adapted and deployed to meet the threat head-on. Topics included are preparatory efforts, development of a team-based staffing model, and a new strategy for resource management. While still maintaining a fully functioning operating theater, discrete teams were deployed to both COVID-19 and non-COVID-19 intensive care units, rapid response/airway management team, the difficult airway response team, and labor and delivery. Additional topics include the creation of a temporary 'pop-up' anesthesiology-run COVID-19 intensive care unit utilizing anesthesia machines for monitoring and ventilatory support as well as the development of a simulation and innovation team that was instrumental in the rapid prototyping of a controlled split-ventilation system and conversion of readily available BIPAP units into emergency ventilators. As the course of the disease is uncertain, the goal of this article is to assist others in preparation for what may come next with COVID-19 as well as potential future pandemics.


Assuntos
COVID-19 , Humanos , Unidades de Terapia Intensiva , Cidade de Nova Iorque , Pandemias , SARS-CoV-2 , Estados Unidos
8.
J Cardiovasc Electrophysiol ; 30(1): 141-148, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30230098

RESUMO

INTRODUCTION: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is most commonly implanted under general anesthesia (GA), due to the intraoperative discomfort associated with tunneling and dissection. Postoperative pain can be substantial and is often managed with opioids. There is a growing interest in transitioning away from the routine use of GA during S-ICD implantation, while also controlling perioperative discomfort without the use of narcotics. As such, we assessed the feasibility of a multimodal analgesia regimen that included regional anesthesia techniques in patients undergoing S-ICD implantation. METHODS AND RESULTS: Twenty patients received truncal plane block (TBL) immediately before S-ICD implantation. The first 10 patients were implanted under general anesthesia (GA + TBL), and the next 10 patients were implanted under deep sedation (DS + TBL). Additionally, the DS + TBL patients were also prescribed a structured regimen of nonopioid analgesics in the perioperative period. Opioid consumption was calculated as milligram morphine equivalents (MME). In-hospital opioid consumption was significantly lower in the patients implanted with DS + TBL (MME = 0) as compared with patients receiving GA + TBL (MME = 60; P = 0.004). CONCLUSIONS: Subcutaneous ICD implantation with anesthesia-delivered DS and a multimodal anesthetic regimen that includes TBL is feasible and associated with significantly less perioperative opioid consumption.


Assuntos
Analgésicos não Narcóticos/administração & dosagem , Analgésicos Opioides/administração & dosagem , Anestesia Geral , Bloqueio Nervoso Autônomo , Sedação Profunda , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Dor Pós-Operatória/prevenção & controle , Implantação de Prótese/instrumentação , Adulto , Idoso , Analgésicos não Narcóticos/efeitos adversos , Analgésicos Opioides/efeitos adversos , Anestesia Geral/efeitos adversos , Bloqueio Nervoso Autônomo/efeitos adversos , Sedação Profunda/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
10.
J Am Coll Cardiol ; 67(21): 2519-32, 2016 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-27230048

RESUMO

Heparin-induced thrombocytopenia is a profoundly dangerous, potentially lethal, immunologically mediated adverse drug reaction to unfractionated heparin or, less commonly, to low-molecular weight heparin. In this comprehensive review, the authors highlight heparin-induced thrombocytopenia's risk factors, clinical presentation, pathophysiology, diagnostic principles, and treatment. The authors place special emphasis on the management of patients requiring procedures using cardiopulmonary bypass or interventions in the catheterization laboratory. Clinical vigilance of this disease process is important to ensure its recognition, diagnosis, and treatment. Misdiagnosis of the syndrome, as well as misunderstanding of the disease process, continues to contribute to its morbidity and mortality.


Assuntos
Anticoagulantes/efeitos adversos , Heparina/efeitos adversos , Trombocitopenia/induzido quimicamente , Antitrombinas/farmacocinética , Antitrombinas/uso terapêutico , Arginina/análogos & derivados , Ponte Cardiopulmonar , Fondaparinux , Hirudinas/farmacocinética , Humanos , Incidência , Fragmentos de Peptídeos/farmacocinética , Fragmentos de Peptídeos/uso terapêutico , Intervenção Coronária Percutânea , Ácidos Pipecólicos/farmacocinética , Ácidos Pipecólicos/uso terapêutico , Plasmaferese , Testes de Função Plaquetária , Transfusão de Plaquetas , Polissacarídeos/uso terapêutico , Proteínas Recombinantes/farmacocinética , Proteínas Recombinantes/uso terapêutico , Fatores de Risco , Sulfonamidas , Trombocitopenia/diagnóstico , Trombocitopenia/terapia
11.
J Thorac Dis ; 7(12): E678-81, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26793389

RESUMO

We describe a rare case of esophageal perforation following cervical mediastinoscopy on a patient with mediastinal lymphadenopathy and right upper lobe (RUL) mass. The patient was successfully treated with esophageal stenting and bilateral pleural exploration and drainage with eventual discharge tolerating a regular diet. This report details an uncommon but noteworthy complication to keep in mind when performing this procedure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA