Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Transl Radiat Oncol ; 48: 100835, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39189000

RESUMO

Background and purpose: As preparation for a national randomized study comparing proton radiotherapy to photon radiotherapy, DAHANCA 35, we performed a non-randomized pilot study to investigate patient selection, logistics, planning, and treatment delivery. With the present study, as a comprehensive safety analysis, we want to compare toxicity during and up to two months after therapy to a historically matched group of patients treated with photon radiotherapy. Materials and methods: 62 patients treated with protons were matched to 124 patients who received photon treatment outside a protocol. Available data were retrieved from the DAHANCA database. Patients were matched on treatment centre, concurrent chemotherapy, tumour site, stage, p16 status for oropharynx cancers. Selection of patients for proton therapy was based on comparative treatment plans with a NTCP reduction for dysphagia and xerostomia at six months. Results: Baseline characteristics between groups were well balanced, except for the type of drug used concurrently; more photon patients received Carboplatin (21.2 % vs 5.8 %, p = 0.01). Proton therapy was associated with significantly less weight loss at the end of treatment, mean weight loss of 3 % for protons and 5 % for photons (p < 0.001). There were more grade 3 skin reactions and grade 3 mucositis after proton treatment compared with photons at the end of treatment, Risk Ratio (RR) 1.9 (95 % CI: 1.01-3.5, p = 0.04) and RR 1.5 (95 % CI: 1.3-1.7, p < 0.001), respectively. All differences resolved at follow up two months after treatment. There were no significant differences between groups on opioid use, use of feeding tubes, or hospitalization during the observation period. Conclusion: Proton treatment resulted in excess objective mucositis and dermatitis, which was transient and did not seem to negatively influence weight or treatment compliance and intensity. Selection bias was likely especially since NTCP models were used for selection of proton treatment and photon treated patients were matched manually. We are currently including patients in a randomized controlled trial.

2.
Radiother Oncol ; 190: 109958, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37871751

RESUMO

Proton radiotherapy offers a dosimetric advantage compared to photon therapy in sparing normal tissue, but the clinical evidence for toxicity reductions in the treatment of head and neck cancer is limited. The Danish Head and Neck Cancer Group (DAHANCA) has initiated the DAHANCA 35 randomised trial to clarify the value of proton therapy (NCT04607694). The DAHANCA 35 trial is performed in an enriched population of patients selected by an anticipated benefit of proton therapy to reduce the risk of late dysphagia or xerostomia based on normal tissue complication probability (NTCP) modelling. We present our considerations on the trial design and a test of the selection procedure conducted before initiating the randomised study.


Assuntos
Neoplasias de Cabeça e Pescoço , Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Prótons , Neoplasias de Cabeça e Pescoço/radioterapia , Terapia com Prótons/métodos , Fótons/uso terapêutico , Probabilidade , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica
3.
Acta Oncol ; 58(10): 1410-1415, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31432744

RESUMO

Introduction: Prediction models using logistic regression may perform poorly in external patient cohorts. However, there is a need to standardize and validate models for clinical use. The purpose of this project was to describe a method for validation of external NTCP models used for patient selection in the randomized trial of protons versus photons in head and neck cancer radiotherapy, DAHANCA 35. Material and methods: Organs at risk of 588 patients treated primarily with IMRT in the randomized controlled DAHANCA19 trial were retrospectively contoured according to recent international recommendations. Dose metrics were extracted using MatLab and all clinical parameters were retrieved from the DAHANCA database. The model proposed by Christianen et al. to predict physician-rated dysphagia was validated through the closed testing, where change of the model intercept, slope and individual beta's were tested for significant prediction improvements. Results: Six months prevalence of dysphagia in the validation cohort was 33%. The closed testing procedure for physician-rated dysphagia showed that the Christianen et al. model needed an intercept refitting for the best match for the Danish patients. The intercept update increased the risk of dysphagia for the validation cohort by 7.9 ± 2.5% point. For the raw model performance, the Brier score (mean squared residual) was 0.467, which improved significantly with a new intercept to 0.415. Conclusions: The previously published Dutch dysphagia model needed an intercept update to match the Danish patient cohort. The implementation of a closed testing procedure on the current validation cohort allows quick and efficient validation of external NTCP models for patient selection in the future.


Assuntos
Transtornos de Deglutição/epidemiologia , Neoplasias de Cabeça e Pescoço/terapia , Modelos Biológicos , Lesões por Radiação/epidemiologia , Radioterapia de Intensidade Modulada/efeitos adversos , Carcinoma de Células Escamosas de Cabeça e Pescoço/terapia , Anticorpos Monoclonais Humanizados/uso terapêutico , Quimiorradioterapia/efeitos adversos , Quimiorradioterapia/métodos , Transtornos de Deglutição/etiologia , Dinamarca/epidemiologia , Humanos , Órgãos em Risco/efeitos da radiação , Seleção de Pacientes , Fótons/efeitos adversos , Fótons/uso terapêutico , Prevalência , Probabilidade , Estudos Prospectivos , Terapia com Prótons/efeitos adversos , Terapia com Prótons/métodos , Lesões por Radiação/etiologia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Medição de Risco/métodos
4.
J Radiat Res ; 55(5): 1002-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24907340

RESUMO

The aim of this study was to carry out geometric and dosimetric evaluation of the usefulness of a deformable image registration algorithm utilized for adaptive head-and-neck intensity-modulated radiotherapy. Data consisted of seven patients, each with a planning CT (pCT), a rescanning CT (ReCT) and a cone beam CT (CBCT). The CBCT was acquired on the same day (± 1 d) as the ReCT (i.e. at Fraction 17, 18, 23, 24 or 29). The ReCT served as ground truth. A deformed CT (dCT) with structures was created by deforming the pCT to the CBCT. The geometrical comparison was based on the volumes of the deformed, and the manually delineated structures on the ReCT. Likewise, the center of mass shift (CMS) and the Dice similarity coefficient were determined. The dosimetric comparison was performed by recalculating the initial treatment plan on the dCT and the ReCT. Dose-volume histogram (DVH) points and a range of conformity measures were used for the evaluation. We found a significant difference in the median volume of the dCT relative to that of the ReCT. Median CMS values were ∼ 2-5 mm, except for the spinal cord, where the median CMS was 8 mm. Dosimetric evaluation of target structures revealed small differences, while larger differences were observed for organs at risk. The deformed structures cannot fully replace manually delineated structures. Based on both geometrical and dosimetrical measures, there is a tendency for the dCT to overestimate the need for replanning, compared with the ReCT.


Assuntos
Algoritmos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Humanos , Posicionamento do Paciente/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA