Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Langmuir ; 39(46): 16422-16431, 2023 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-37934460

RESUMO

Herein, a sensitive and selective electrochemical sensor based on aptamer folding was constructed to detect aflatoxin B1 (AFB1) in peanuts. Specifically, polyethylenimine-functionalized multiwalled carbon nanotubes modified with molybdenum disulfide (MoS2@MWCNTs-PEI) were used as the electrode matrix to enable a large specific surface area, which were characterized by the Randles-Sevcik equation. Additionally, AuNPs were used to immobilize the aptamer via the Au-S covalent bond and provide a favorable microenvironment for signal enhancement. Methylene blue (MB) was modified at the proximal 3' termini of the aptamer as the capture probe, while the signal transduction of the sensor was obtained through changes in conformation and position of MB induced by the binding between AFB1 and the probe. Changes in spatial conformation could be recorded by electrochemical methods more readily. This electrochemical aptasensor demonstrated remarkable sensitivity to AFB1 with an extensive detection range (1 pg/mL to 100 ng/mL) and a lower limit detection (1.0 × 10-3 ng/mL). Moreover, using the constructed aptasensor, AFB1 was identified successfully in peanut samples, with recoveries ranging from 95.83 to 107.53%, illustrating its potential use in determining AFB1 in food.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Nanopartículas Metálicas , Nanotubos de Carbono , Arachis/química , Aflatoxina B1/análise , Aflatoxina B1/química , Aptâmeros de Nucleotídeos/química , Ouro/química , Molibdênio , Nanopartículas Metálicas/química , Técnicas Biossensoriais/métodos , Limite de Detecção , Técnicas Eletroquímicas/métodos
2.
Anal Bioanal Chem ; 415(23): 5833-5844, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37477648

RESUMO

A highly selective and sensitive "on-off-on" electrochemiluminescence (ECL) aptasensor based on a self-enhanced luminophore was developed for the detection of ochratoxin A (OTA). Specifically, polyethyleneimine functionalized multi-walled carbon nanotubes decorated with gold nanoparticles (AuNPs-PEI-MWCNTs) were used as the electrode matrix to accelerate electron transfer and provide a favorable microenvironment for self-enhanced luminophore loading and ECL signal enhancement. In addition, black phosphorus quantum dots (BPQDs) were used as co-reactants of the ECL reagent tris (2,2'-bipyridyl) ruthenium(II) (Ru(bpy)32+) in ECL experiments, and the reaction mechanism was investigated. The self-enhanced luminophore Ru@SiO2-BPQDs was obtained by encapsulating Ru(bpy)32+ in silica (SiO2) nanoparticles and then combining it with BPQDs through electrostatic interaction. In conventional ECL systems, the emitter and its co-reactants reacted via the inter-nanoparticle pathway, leading to long distance electron transfer. However, the electron transfer distance in the self-enhanced luminophore was significantly shortened due to the intra-nanoparticle electron transfer pathway because BPQDs and oxidized Ru(bpy)32+ were bound within one nanoparticle, thereby improving ECL efficiency to achieve the first "switch-on" state. Then, the luminophore was quenched using ferrocenes (Fc) modified on an aptamer to achieve the "switch-off" state. Finally, OTA was specifically identified by the adapter, causing Fc to be released from the sensor interface, restoring the ECL intensity to achieve the second "switch-on" state. Under optimal conditions, the aptasensor exhibited good sensitivity, stability, and reproducibility, with a linear detection range from 0.1 to 320 ng/mL and a detection limit of 0.03 ng/mL. The novel ECL aptasensor provided a common analytical tool for the detection of mycotoxins and other small molecules.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Nanopartículas Metálicas , Nanotubos de Carbono , Ouro , Dióxido de Silício , Reprodutibilidade dos Testes , Medições Luminescentes , Metalocenos , Técnicas Eletroquímicas
3.
Opt Lett ; 48(7): 1882-1885, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37221790

RESUMO

The application of plasmonic structure has been demonstrated to improve the performance of infrared photodetectors. However, the successful experimental realization of the incorporation of such optical engineering structure into HgCdTe-based photodetectors has rarely been reported. In this paper, we present a HgCdTe infrared photodetector with integrated plasmonic structure. The experimental results show that the device with plasmonic structure has a distinct narrowband effect with a peak response rate close to 2 A/W, which is nearly 34% higher compared with the reference device. The simulation results are in good agreement with the experiment, and an analysis of the effect of the plasmonic structure is given, demonstrating the crucial role of the plasmonic structure in the enhancement of the device performance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA