Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Hazard Mater ; 287: 162-70, 2015 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-25644032

RESUMO

Methyl tert-butyl ether (MTBE) is used at significant percentages as an additive of unleaded gasoline. The physical-chemical properties of the substance (water solubility, soil organic carbon-water partition coefficient) cause high mobility and high concentrations in groundwater. Laboratory scale batch and column tests and mathematical modeling were performed to study the feasibility of a biobarrier (BB), that is an in situ permeable biological barrier with or without inoculation, for the remediation of MTBE and other gasoline-derived pollutants (benzene, toluene, ethylbenzene, o-xylene and m+p-xylenes, BTEXs) polluted groundwater and to estimate kinetic constants. The experimental results showed simultaneous biodegradation of MTBE and BTEXs, with similar removals in the uninoculated and the inoculated systems. Ranges for the first order kinetic removal were obtained for MTBE ((0.18±0.02)/(0.28±0.11d(-1))), B ((0.39±0.12)/(0.56±0.12d(-1))), T ((0.51±0.03)/(0.78±0.15d(-1))), E ((0.46±0.18)/(1.57±0.21d(-1))), o-X ((0.24±0.08)/(0.64±0.09d(-1))) and m+p-X ((0.20±0.04)/(1.21±0.04d(-1))). The results of the laboratory tests allowed to improve mathematical modeling in order to design a full-scale BB at a gasoline-contaminated site.


Assuntos
Derivados de Benzeno/metabolismo , Betaproteobacteria/metabolismo , Éteres Metílicos/metabolismo , Poluição por Petróleo , Rhodococcus/metabolismo , Simulação por Computador , Recuperação e Remediação Ambiental/métodos , Gasolina , Água Subterrânea , Consórcios Microbianos , Modelos Teóricos , Poluentes Químicos da Água/metabolismo
2.
Environ Technol ; 36(9-12): 1114-22, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25354811

RESUMO

This paper reports the results of a road pavement full-scale test track built by using stabilized bottom ash (SBA) from an Italian municipal solid waste incinerator as the aggregate in granular foundation, cement-bound mixes and asphalt concretes. The investigation focused on both the performance and the environmental compatibility of such mixes, especially with regard to the effects of mixing, laying and compaction. From the road construction point of view, the performance related to the effects of mixing, laying and compaction on constructability was assessed, as well as the volumetric and the mechanical properties. Environmental aspects were investigated by leaching tests. The results suggested that SBA meets the environmental Italian law for the reuse of non-hazardous waste and could be used as road material with the procedures, plants and equipment currently used for road construction.


Assuntos
Materiais de Construção , Incineração , Teste de Materiais
3.
Water Sci Technol ; 67(3): 453-68, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23202548

RESUMO

Biobarriers (BBs) are a new type of in situ technology for the remediation of contaminated groundwater. In recent years, this remediation technique has been more and more used in place of traditional Pump & Treat systems or other in situ technologies both in the USA and Europe. This work reviews the main experiences of BBs. The literature contains reports about tests and application at different scales (laboratory, pilot and full scale), which have been analyzed according to the aim of the study, the operative conditions adopted, the filling material, the inoculation procedure, the electron acceptor and the nutrient delivery systems. Operative conditions were extremely varied. Lab scale experiments pointed out good results in terms of pollutant removal efficiency. Pilot scale tests and full-scale applications confirmed the results obtained at lab scale, but also pointed out the importance of design for a proficient remediation system. The experiences underlined some possible critical issues: (a) the filling material must ensure proper hydraulic properties, but it also must be capable of keeping biomass in the reactive zone; (b) inoculation is a critical step and measurements should be carried out to check the initial distribution of microorganisms and its evolution over time; (c) electron acceptor and nutrient supply is usually required, but oxygenation into anaerobic aquifers can be critical.


Assuntos
Recuperação e Remediação Ambiental/instrumentação , Água Subterrânea , Purificação da Água/instrumentação , Poluentes da Água , Poluição da Água/prevenção & controle
4.
Environ Technol ; 30(8): 817-23, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19705665

RESUMO

This paper presents preliminary results of laboratory tests aimed at evaluating the easibility of the remediation of marine sediments, which are polluted by mercury and petroleum hydrocarbons, dredged at the bay of Augusta (SR, Italy). The treatment is composed of two sequential steps: in the first, a cement-based granular material is produced (based on a high performance concrete approach); then, the volatile and the semi-volatile compounds in the granular material are removed by a thermal desorption step. Treated materials could be reused or put into caissons, according to their mechanical properties and environmental compatibility. The experiments were focused on evaluating the effect of the process parameter values on: (i) the evolution of cement hydration reactions, (ii) thermal desorption removal efficiencies, (iii) leaching behaviour of the treated material.


Assuntos
Sedimentos Geológicos/química , Gerenciamento de Resíduos/métodos , Poluentes Químicos da Água/análise , Materiais de Construção/análise , Recuperação e Remediação Ambiental , Estudos de Viabilidade , Cinética , Microscopia Eletrônica de Varredura , Oceanos e Mares , Compostos Orgânicos Voláteis/análise
6.
Phys Med Biol ; 44(1): 1-11, 1999 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10071871

RESUMO

The propagation of light emitted by a linear light diffuser in a cylindrical hollow organ was investigated by means of the Monte Carlo (MC) method. The height and radius of the cavity, scattering (mu(s)) (or reduced scattering, mu'(s)) and absorption (mu(a)) coefficients, anisotropy (g), and refractive indices of the media involved (n1, n2) are required as input data by the MC code, as are characteristics of the light diffuser (length, delivered power and emission profile). Results of our MC model were tested by measuring the light fluence rate in a tissue-simulating phantom (mu(a) = 0.5 cm(-1), mu(s) = 23 cm(-1) and g = 0.75) irradiated at 633 nm with a cylindrical diffuser. Since geometric and optical parameters determine the behaviour of light propagation in tissue, MC simulations with different sets of input parameters were carried out to provide qualitative as well as quantitative data useful in planning photodynamic therapy. Data are reported on light penetration and fluence rate build-up at mu(a) and mu'(s) values ranging between 0.1 and 5 cm(-1) and 2.5 and 50 cm(-1), respectively. Furthermore, results suggest that a shift and spread could occur in the isofluence curves along the symmetry axis, which depend on the diameter of the treated lumen as well as on the emission profile of the light diffuser. Using our data it is possible to estimate how inaccuracy in knowledge of the optical coefficients can affect (i.e. usually by increasing) the light dose scheduled at a certain depth into tissue.


Assuntos
Método de Monte Carlo , Fotoquimioterapia , Espalhamento de Radiação , Anisotropia , Simulação por Computador , Humanos , Luz , Modelos Teóricos , Imagens de Fantasmas
7.
J Neuroimaging ; 4(1): 48-50, 1994 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8136582

RESUMO

Cerebral venous outflow obstruction and anomalies in cerebral venous circulation predispose to dural sinus thrombosis. This case report illustrates the magnetic resonance and angiographic findings in a patient who had superior sagittal sinus thrombosis secondary to idiopathic bilateral internal jugular vein stenosis, a previously unrecognized entity. The findings suggest that bilateral stenosis of the internal jugular veins at their junction with the innominate veins causes obstruction to cerebral venous outflow leading to dural sinus thrombosis.


Assuntos
Dura-Máter/irrigação sanguínea , Embolia e Trombose Intracraniana/etiologia , Veias Jugulares/patologia , Constrição Patológica/complicações , Lateralidade Funcional/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade
8.
Invest Radiol ; 26(12): 1041-52, 1991 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-1765436

RESUMO

In vitro animal and human models were used to evaluate the potential of chemical shift magnetic resonance imaging (MRI) for assessing fatty liver. Phantoms of varying fat content were created from mayonnaise-agar preparations. Fatty liver was induced in eight rats by feeding them ethanol for three to six weeks (36% of total calories), whereas eight control rats were fed a normal diet. T1-weighted in-phase and opposed-phase MR images were obtained of the phantoms animals, and 28 human subjects. Additional images obtained in animals included long TR images with in-phase and opposed-phase technique, and hybrid chemical shift water and fat suppression. The rats were killed and histologic status was graded blindly by a hepatopathologist as normal, mild, moderate, or severe fatty change, for correlation with MR grading. Quantitative analysis of MR images included fat signal fraction for animals, and relative signal decrease between in-phase and opposed-phase images for phantom and human data. Phantom in-phase signal increased linearly with respect to fat content, whereas opposed-phase signal decreased linearly. MRI and histologic grading of rat livers were highly correlated, especially when based on water suppression images (r = 0.91, P = .0001). Opposed-phase images were also highly correlated, while fat suppression images were less effective. There was no overlap between MR-derived fat fractions for control (2.6%-5.7%) versus ethanol-fed rats (7.7%-17.9%, P = .0002). Human liver considered to be fatty by visual inspection (n = 8) had higher relative signal decrease than nonfatty liver (n = 22) (P less than .001). Phantom, animal, and human data demonstrate that comparison of T1-weighted in-phase and opposed-phase images is both practical and sensitive in the detection and grading of fatty liver.


Assuntos
Fígado Gorduroso/diagnóstico , Fígado/patologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Animais , Fígado Gorduroso Alcoólico/diagnóstico , Feminino , Humanos , Fígado/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Modelos Estruturais , Ratos , Ratos Endogâmicos
9.
Radiology ; 178(1): 67-71, 1991 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-1984328

RESUMO

T1-weighted spin-echo magnetic resonance (MR) images have had limited soft-tissue contrast at 1.5 T. The authors investigated the effects of echo-time (TE) minimization and fat suppression on MR images of the liver and pancreas. Two sets of MR images were obtained with identical repetition times and other parameters. In 10 subjects with seven liver lesions, images with TEs of 20 and 12 msec were compared. In 18 additional subjects with seven liver lesions and five pancreatic carcinomas, images with identical TEs but with and without fat suppression were compared. Contrast-to-noise ratios (CNRs) were greater with a TE of 12 msec than with a TE of 20 msec for liver versus spleen (7.6 vs 4.9, P = .014) and liver versus lesion (6.9 vs 3.9, P = .031). In patients without fatty liver, CNR for six lesions versus liver was greater (9.5 vs 6.0, P = .014) with fat suppression. CNR between glandular pancreas and cancer was most conspicuous with fat suppression, but fat planes were less distinct. Minimization of TE improves T1-weighted images significantly. Fat suppression also improves CNR, but the disadvantages of fat suppression do not allow elimination of conventional T1-weighted images.


Assuntos
Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Pâncreas/patologia , Fígado Gorduroso/diagnóstico , Humanos , Neoplasias Hepáticas/diagnóstico , Neoplasias Pancreáticas/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA