Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
J Nucl Med ; 65(9): 1409-1415, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39142827

RESUMO

Recurrence of meningiomas after surgery and radiotherapy deserves specific attention because of the lack of active third-line therapies. Somatostatin receptors are usually overexpressed on the cell membrane of meningiomas, and this has led the way to a radionuclide theranostic approach. Diagnoses with 68Ga-DOTA-octreotide and peptide receptor radionuclide therapy (PRRT) with 90Y/177Lu-DOTA-octreotide are currently possible options within experimental protocols or as compassionate use in small patient groups. Methods: From October 2009 to October 2021, 42 meningioma patients with radiologic recurrence after standard therapies were treated with 90Y-DOTATOC (dosage of 1.1 or 5.5 GBq) or with 177Lu-DOTATATE (dosage of 3.7 or 5.5 GBq) in a mean of 4 cycles. All patients showed intense uptake at diagnostic 68Ga-DOTATOC PET/CT or in an 111In-octreotide scan. Results: Of 42 patients treated, 5 patients received 90Y-DOTATOC with a cumulative activity of 11.1 GBq and 37 patients received 177Lu-DOTATATE with a cumulative activity of 22 GBq. The disease control rate was 57%. With a median follow-up of 63 mo, median progression-free survival was 16 mo, and median overall survival was 36 mo. Retreatment 177Lu-PRRT was performed in 6 patients with an administered median activity of 13 GBq in a mean of 5 cycles. With a 75.8-mo follow-up, median progression-free survival and overall survival were 6.5 and 17 mo, respectively. Only 1 patient discontinued the treatment because of grade 3 platelet toxicity. A rapidly transient grade 2 neutropenia was recorded in 1 retreated patient. Conclusion: PRRT in patients with advanced meningiomas overexpressing somatostatin receptor 2 was active and well tolerated, showing a 57% disease control rate. Furthermore, PRRT could represent a potential retreatment option. Further studies, also in combination with other treatments, are warranted.


Assuntos
Neoplasias Meníngeas , Meningioma , Octreotida , Humanos , Meningioma/radioterapia , Meningioma/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Octreotida/análogos & derivados , Octreotida/uso terapêutico , Octreotida/efeitos adversos , Seguimentos , Adulto , Resultado do Tratamento , Neoplasias Meníngeas/radioterapia , Neoplasias Meníngeas/diagnóstico por imagem , Receptores de Peptídeos/metabolismo , Receptores de Somatostatina/metabolismo , Compostos Organometálicos/uso terapêutico , Idoso de 80 Anos ou mais
2.
Cancers (Basel) ; 16(13)2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-39001374

RESUMO

The initial favorable efficacy and safety profile for Alpha DaRT have been demonstrated (NCT04377360); however, the longer-term safety and durability of the treatment are unknown. This pooled analysis of four prospective trials evaluated the long-term safety and efficacy of Alpha DaRT for the treatment of head and neck or skin tumors. A total of 81 lesions in 71 patients were treated across six international institutions, with a median follow-up of 14.1 months (range: 2-51 months). Alpha DaRT sources were delivered via a percutaneous interstitial technique and placed to irradiate the tumor volume with the margin. The sources were removed two to three weeks following implantation. A complete response was observed in 89% of treated lesions (n = 72) and a partial response in 10% (n = 8). The two-year actuarial local recurrence-free survival was 77% [95% CI 63-87]. Variables, including recurrent versus non-recurrent lesions, baseline tumor size, or histology, did not impact long-term outcomes. Twenty-seven percent of patients developed related acute grade 2 or higher toxicities, which resolved with conservative measures. No grade 2 or higher late toxicities were observed. These data support the favorable safety profile of Alpha DaRT, which is currently being explored in a pivotal US trial.

3.
Phys Med ; 117: 103188, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38042710

RESUMO

Radionuclide therapy, also called molecular radiotherapy (MRT), has come of age, with several novel radiopharmaceuticals being approved for clinical use or under development in the last decade. External beam radiotherapy (EBRT) is a well-established treatment modality, with about half of all oncologic patients expected to receive at least one external radiation treatment over their disease course. The efficacy and the toxicity of both types of treatment rely on the interaction of radiation with biological tissues. Dosimetry played a fundamental role in the scientific and technological evolution of EBRT, and absorbed doses to the target and to the organs at risk are calculated on a routine basis. In contrast, in MRT the usefulness of internal dosimetry has long been questioned, and a structured path to include absorbed dose calculation is missing. However, following a similar route of development as EBRT, MRT treatments could probably be optimized in a significant proportion of patients, likely based on dosimetry and radiobiology. In the present paper we describe the differences and the similarities between internal and external-beam dosimetry in the context of radiation treatments, and we retrace the main stages of their development over the last decades.


Assuntos
Tartarugas , Animais , Humanos , Radiometria , Compostos Radiofarmacêuticos/uso terapêutico , Dosagem Radioterapêutica
4.
Eur Radiol ; 34(1): 422-432, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37566266

RESUMO

OBJECTIVES: In this study, we developed a radiomic signature for the classification of benign lipid-poor adenomas, which may potentially help clinicians limit the number of unnecessary investigations in clinical practice. Indeterminate adrenal lesions of benign and malignant nature may exhibit different values of key radiomics features. METHODS: Patients who had available histopathology reports and a non-contrast-enhanced CT scan were included in the study. Radiomics feature extraction was done after the adrenal lesions were contoured. The primary feature selection and prediction performance scores were calculated using the least absolute shrinkage and selection operator (LASSO). To eliminate redundancy, the best-performing features were further examined using the Pearson correlation coefficient, and new predictive models were created. RESULTS: This investigation covered 50 lesions in 48 patients. After LASSO-based radiomics feature selection, the test dataset's 30 iterations of logistic regression models produced an average performance of 0.72. The model with the best performance, made up of 13 radiomics features, had an AUC of 0.99 in the training phase and 1.00 in the test phase. The number of features was lowered to 5 after performing Pearson's correlation to prevent overfitting. The final radiomic signature trained a number of machine learning classifiers, with an average AUC of 0.93. CONCLUSIONS: Including more radiomics features in the identification of adenomas may improve the accuracy of NECT and reduce the need for additional imaging procedures and clinical workup, according to this and other recent radiomics studies that have clear points of contact with current clinical practice. CLINICAL RELEVANCE STATEMENT: The study developed a radiomic signature using unenhanced CT scans for classifying lipid-poor adenomas, potentially reducing unnecessary investigations that scored a final accuracy of 93%. KEY POINTS: • Radiomics has potential for differentiating lipid-poor adenomas and avoiding unnecessary further investigations. • Quadratic mean, strength, maximum 3D diameter, volume density, and area density are promising predictors for adenomas. • Radiomics models reach high performance with average AUC of 0.95 in the training phase and 0.72 in the test phase.


Assuntos
Adenoma Adrenocortical , Radiômica , Humanos , Benchmarking , Tomografia Computadorizada por Raios X , Lipídeos , Estudos Retrospectivos
5.
Pharmaceuticals (Basel) ; 16(8)2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37631057

RESUMO

Molecular Radiation Therapy (MRT) is a valid therapeutic option for a wide range of malignancies, such as neuroendocrine tumors and liver cancers. In its practice, it is generally acknowledged that there is a need to evaluate the influence of different factors affecting the accuracy of dose estimates and to define the actions necessary to maintain treatment uncertainties at acceptable levels. The present study addresses the problem of uncertainty propagation in 90Y-PET quantification. We assessed the quantitative accuracy in reference conditions of three PET scanners (namely, Siemens Biograph mCT, Siemens Biograph mCT flow, and GE Discovery DST) available at three different Italian Nuclear Medicine centers. Specific aspects of uncertainty within the quantification chain have been addressed, including the uncertainty in the calibration procedure. A framework based on the Guide to the Expression of Uncertainty in Measurement (GUM) approach is proposed for modeling the uncertainty in the quantification processes, and ultimately, an estimation of the uncertainty achievable in clinical conditions is reported.

6.
Sci Data ; 9(1): 695, 2022 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-36371503

RESUMO

In radiology and oncology, radiomic models are increasingly employed to predict clinical outcomes, but their clinical deployment has been hampered by lack of standardisation. This hindrance has driven the international Image Biomarker Standardisation Initiative (IBSI) to define guidelines for image pre-processing, standardise the formulation and nomenclature of 169 radiomic features and share two benchmark digital phantoms for software calibration. However, to better assess the concordance of radiomic tools, more heterogeneous phantoms are needed. We created two digital phantoms, called ImSURE phantoms, having isotropic and anisotropic voxel size, respectively, and 90 regions of interest (ROIs) each. To use these phantoms, we designed a systematic feature extraction workflow including 919 different feature values (obtained from the 169 IBSI-standardised features considering all possible combinations of feature aggregation and intensity discretisation methods). The ImSURE phantoms will allow to assess the concordance of radiomic software depending on interpolation, discretisation and aggregation methods, as well as on ROI volume and shape. Eventually, we provide the feature values extracted from these phantoms using five open-source IBSI-compliant software.

7.
Sci Data ; 9(1): 412, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35840608

RESUMO

In a clinical contest, it is common to use dedicated phantoms to perform quality assurance test to check the performance of a SPECT system. Some of these phantoms are also used to calibrate the system for dosimetric evaluation of patients undergoing radiometabolic cancer therapy. In this work, a 3D-OSEM reconstructed 177Lu SPECT dataset of a homogeneous cylindrical phantom is described. This dataset was acquired to investigate the variation of the SPECT calibration factor, counts convergence, noise and uniformity by varying the number of subsets and iterations. In particular, the dataset is composed of images reconstructed using five different numbers of subsets and sixteen different numbers of iterations, for a total of 80 different configurations. The dataset is suitable for comparison with other reconstruction algorithms (e.g. FBP, MLEM, etc.) and radionuclides (e.g. technetium, yttrium). In regards to the uniformity issue, the same dataset allows the user to perform radiomic investigations on the influence of the border effect on the reconstructed images.


Assuntos
Algoritmos , Tomografia Computadorizada de Emissão de Fóton Único , Calibragem , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/métodos
9.
Cancers (Basel) ; 14(8)2022 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-35454793

RESUMO

Prostate cancer (PCa) risk categorization based on clinical/PSA testing results in a substantial number of men being overdiagnosed with indolent, early-stage PCa. Clinically non-significant PCa is characterized as the presence of ISUP grade one, where PCa is found in no more than two prostate biopsy cores.MRI-ADC and [68Ga]Ga-PSMA-11 PET have been proposed as tools to predict ISUP grade one patients and consequently reduce overdiagnosis. In this study, Radiomics analysis is applied to MRI-ADC and [68Ga]Ga-PSMA-11 PET maps to quantify tumor characteristics and predict histology-proven ISUP grades. ICC was applied with a threshold of 0.6 to assess the features' stability with variations in contouring. Logistic regression predictive models based on imaging features were trained on 31 lesions to differentiate ISUP grade one patients from ISUP two+ patients. The best model based on [68Ga]Ga-PSMA-11 PET returned a prediction efficiency of 95% in the training phase and 100% in the test phase whereas the best model based on MRI-ADC had an efficiency of 100% in both phases. Employing both imaging modalities, prediction efficiency was 100% in the training phase and 93% in the test phase. Although our patient cohort was small, it was possible to assess that both imaging modalities add information to the prediction models and show promising results for further investigations.

10.
Radiology ; 303(3): 533-541, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35230182

RESUMO

Background The translation of radiomic models into clinical practice is hindered by the limited reproducibility of features across software and studies. Standardization is needed to accelerate this process and to bring radiomics closer to clinical deployment. Purpose To assess the standardization level of seven radiomic software programs and investigate software agreement as a function of built-in image preprocessing (eg, interpolation and discretization), feature aggregation methods, and the morphological characteristics (ie, volume and shape) of the region of interest (ROI). Materials and Methods The study was organized into two phases: In phase I, the two Image Biomarker Standardization Initiative (IBSI) phantoms were used to evaluate the IBSI compliance of seven software programs. In phase II, the reproducibility of all IBSI-standardized radiomic features across tools was assessed with two custom Italian multicenter Shared Understanding of Radiomic Extractors (ImSURE) digital phantoms that allowed, in conjunction with a systematic feature extraction, observations on whether and how feature matches between program pairs varied depending on the preprocessing steps, aggregation methods, and ROI characteristics. Results In phase I, the software programs showed different levels of completeness (ie, the number of computable IBSI benchmark values). However, the IBSI-compliance assessment revealed that they were all standardized in terms of feature implementation. When considering additional preprocessing steps, for each individual program, match percentages fell by up to 30%. In phase II, the ImSURE phantoms showed that software agreement was dependent on discretization and aggregation as well as on ROI shape and volume factors. Conclusion The agreement of radiomic software varied in relation to factors that had already been standardized (eg, interpolation and discretization methods) and factors that need standardization. Both dependences must be resolved to ensure the reproducibility of radiomic features and to pave the way toward the clinical adoption of radiomic models. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Steiger in this issue. An earlier incorrect version appeared online and in print. This article was corrected on March 2, 2022.


Assuntos
Benchmarking , Processamento de Imagem Assistida por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Software
11.
Cancers (Basel) ; 14(4)2022 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-35205825

RESUMO

Previously published studies combined external beam radiotherapy (EBRT) treatments with different activities of 223Ra. The data of two-year overall survival (2y-OS) and neutropenia (TOX) incidence when combining EBRT and 223Ra are not homogeneous in literature. We adapted the linear-quadratic model (LQ) to 223Ra therapy using brachytherapy formalism for a mixture of radionuclides, considering the contribution of all daughter isotopes in the decay chain. A virtual cohort of patients undergoing 223Ra therapy was derived using data from the literature. The doses delivered using 223Ra and EBRT were converted into biologically equivalent doses. Fixed-effect logistic regression models were derived for both the 2y-OS and TOX and compared with available literature. Based on the literature search, four studies were identified to have reported the 223Ra injection activity levels varying from the placebo (0) to 80 kBq/kg, associated or not with EBRT. Logistic regression models revealed a dose-dependent increase in both the 2y-OS (intercept = -1.364; slope = 0.006; p-value ≤ 0.05) and TOX (-5.035; 0.018; ≤0.05) using the EBRT schedule of 8 Gy in 1 fr. Similar results were obtained for other schedules. Discrepancies between our TOX model and those derived for EBRT combined with chemotherapy are discussed. Radiobiological models allow us to estimate dose-dependent relationships, to predict the OS and TOX following combined 223Ra + EBRT treatment, which will guide future treatment optimization.

12.
Sci Rep ; 12(1): 14, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34996956

RESUMO

The majority of local recurrences, after conservative surgery of breast cancer, occurs in the same anatomical area where the tumour was originally located. For the treatment of ductal carcinoma in situ (DCIS), a new medical device, named BAT-90, (BetaGlue Technologies SpA) has been proposed. BAT-90 is based on the administration of 90Y ß-emitting microspheres, embedded in a bio-compatible matrix. In this work, the Geant4 simulation toolkit is used to simulate BAT-90 as a homogenous cylindrical 90Y layer placed in the middle of a bulk material. The activity needed to deliver a 20 Gy isodose at a given distance z from the BAT-90 layer is calculated for different device thicknesses, tumour bed sizes and for water and adipose bulk materials. A radiobiological analysis has been performed using both the Poisson and logistic Tumour Control Probability (TCP) models. A range of radiobiological parameters (α and ß), target sizes, and densities of tumour cells were considered. Increasing α values, TCP increases too, while, for a fixed α value, TCP decreases as a function of clonogenic cell density. The models predict very solid results in case of limited tumour burden while the activity/dose ratio could be further optimized in case of larger tumour beds.


Assuntos
Neoplasias da Mama/radioterapia , Carcinoma Ductal de Mama/radioterapia , Carcinoma Intraductal não Infiltrante/radioterapia , Radioterapia/métodos , Simulação por Computador , Feminino , Humanos , Modelos Logísticos , Radioterapia/instrumentação , Dosagem Radioterapêutica , Carga Tumoral
13.
Cancers (Basel) ; 14(1)2022 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-35008404

RESUMO

The purpose of this study is to discuss how to use an external radio-opaque template in the Diffusing Alpha-emitters Radiation Therapy (DaRT) technique's pre-planning and treatment stages. This device would help to determine the proper number of sources for tumour coverage, accounting for subcutaneous invasion and augmenting DaRT safety. The procedure will be carried out in a first phase on a phantom and then applied to a clinical case. A typical DaRT procedure workflow comprises steps like tumour measurements and delineation, source number assessment, and therapy administration. As a first step, an adhesive fiberglass mesh (spaced by 2 mm) tape was applied on the skin of the patient and employed as frame of reference. A physician contoured the lesion and marked the entrance points for the needles with a radio opaque ink marker. According to the radio opaque marks and metabolic uptake the clinical target volume was defined, and with a commercial brachytherapy treatment planning system (TPS) it was possible to simulate and adjust the spatial seeds distribution. After the implant procedure a CT was again performed to check the agreement between simulations and seeds positions. With the procedure described above it was possible to simulate a DaRT procedure on a phantom in order to train physicians and subsequently apply the novel approach on patients, outlining the major issues involved in the technique. The present work innovates and supports DaRT technique for the treatment of cutaneous cancers, improving its efficacy and safety.

14.
Cell Death Dis ; 13(1): 80, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35075119

RESUMO

Glioblastoma (GBM) is the most lethal brain tumor in adults. Radiation, together with temozolomide is the standard treatment, but nevertheless, relapse occurs in nearly all cases. Understanding the mechanisms underlying radiation resistance may help to find more effective therapies. After radiation treatment, ATP is released into the tumor microenvironment where it binds and activates purinergic P2 receptors, mainly of the P2X7 subtype. Two main P2X7 splice variants, P2X7A and P2X7B, are expressed in most cell types, where they associate with distinct biochemical and functional responses. GBM cells widely differ for the level of P2X7 isoform expression and accordingly for sensitivity to stimulation with extracellular ATP (eATP). Irradiation causes a dramatic shift in P2X7 isoform expression, with the P2X7A isoform being down- and the P2X7B isoform up-modulated, as well as extensive cell death and overexpression of stemness and senescence markers. Treatment with P2X7 blockers during the post-irradiation recovery potentiated irradiation-dependent cytotoxicity, suggesting that P2X7B activation by eATP generated a trophic/growth-promoting stimulus. Altogether, these data show that P2X7A and B receptor isoform levels are inversely modulated during the post-irradiation recovery phase in GBM cells.


Assuntos
Trifosfato de Adenosina , Glioblastoma , Receptores Purinérgicos P2X7 , Trifosfato de Adenosina/metabolismo , Glioblastoma/genética , Glioblastoma/metabolismo , Glioblastoma/radioterapia , Humanos , Recidiva Local de Neoplasia , Isoformas de Proteínas/genética , Isoformas de Proteínas/metabolismo , Receptores Purinérgicos P2X7/genética , Microambiente Tumoral
15.
Semin Nucl Med ; 52(2): 191-214, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34996594

RESUMO

Radioimmunotherapy (RIT) is a safe and active treatment available for non-Hodgkin lymphomas (NHLs). In particular, two monoclonal antibodies raised against CD20, that is Zevalin (90Y-ibritumomab-tiuxetan) and Bexxar (131I-tositumomab) received FDA approval for the treatment of relapsing/refractory indolent or transformed NHLs. RIT is likely the most effective and least toxic anticancer agent in NHLs. However, its use in the clinical setting is still debated and, in case of relapse after optimized rituximab-containing regimens, the efficacy of RIT at standard dosage is suboptimal. Thus, clinical trials were based on the hypothesis that the inclusion of RIT in myeloablative conditioning would allow to obtain improved efficacy and toxicity profiles when compared to myeloablative total-body irradiation and/or high-dose chemotherapy regimens. Standard-activity RIT has a safe toxicity profile, and the utility of pretherapeutic dosimetry in this setting can be disputed. In contrast, dose-escalation clinical protocols require the assessment of radiopharmaceutical biodistribution and dosimetry before the therapeutic injection, as dose constrains for critical organs may be exceeded when RIT is administered at high activities. The aim of the present study was to review and discuss the internal dosimetry protocols that were adopted for non-standard RIT administration in the myeloablative setting before hematopoietic stem cell transplantation in patients with NHLs.


Assuntos
Linfoma não Hodgkin , Radioimunoterapia , Antígenos CD20/uso terapêutico , Humanos , Linfoma não Hodgkin/tratamento farmacológico , Linfoma não Hodgkin/radioterapia , Recidiva Local de Neoplasia/tratamento farmacológico , Radioimunoterapia/métodos , Distribuição Tecidual , Radioisótopos de Ítrio/uso terapêutico
16.
Q J Nucl Med Mol Imaging ; 65(4): 342-352, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34881852

RESUMO

In the last few decades, the incidence and prevalence of neuroendocrine tumors has been increasing. The theragnostic approach, that allows the diagnosis and treatment of different neoplasms with the same ligand, is a typical nuclear medicine tool. Applied for years, is also pivotal in neuroendocrine tumors (NETs) where it has improved the diagnostic accuracy and the therapeutic efficacy with impact on patient's survival. Theragnostic also allows the identification of important prognostic factors such as tumor location and burden, presence of liver metastases and intensity of somatostatin receptors (SSTR) expression to consider in new and possibly combined studies to ameliorate patient's outcome. Moreover, the possibility to evaluate receptor expression even in non-NET malignancies has de facto widened the possible indications for PRRT. We believe that this innovative therapeutic approach will be implemented in next years by radiomics and biological tumors characterization to better address PRRT applications.


Assuntos
Tumores Neuroendócrinos , Octreotida , Humanos , Tumores Neuroendócrinos/diagnóstico por imagem , Cintilografia , Receptores de Somatostatina
17.
Sci Data ; 8(1): 209, 2021 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-34354085

RESUMO

Testicular cancer is a rare tumor with a worldwide incidence that has increased over the last few decades. The majority of these tumors are testicular non-germ (TNGCTs) and germ cell tumors (TGCTs); the latter divided into two broad classes - seminomatous (SGCTs) and non-seminomatous germ cell tumors (NSGCTs). Although ultrasonography (US) maintains a primary role in the diagnostic workup of scrotal pathology, magnetic resonance imaging (MRI) has emerged as the imaging modality recommended for challenging cases, providing additional information to clarify inconclusive/equivocal US. In this work we describe and publicly share a collection of 44 images of annotated T2-weighted MRI lesions from 42 patients. Given that testicular cancer is a rare tumor, we are confident that this collection can be used to validate statistical models and to further investigate TNGCT and TGCT peculiarities using medical imaging features.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias Embrionárias de Células Germinativas/diagnóstico por imagem , Neoplasias Testiculares/diagnóstico por imagem , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Seminoma/diagnóstico por imagem , Testículo/diagnóstico por imagem , Testículo/patologia , Adulto Jovem
18.
Pharmaceuticals (Basel) ; 14(7)2021 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-34206461

RESUMO

Radiopharmaceuticals targeting the prostate-specific membrane antigen (PSMA) has become the gold standard for PET imaging of prostate cancer. [68Ga]Ga-PSMA-11 has been the forerunner but a [18F]F-PSMA ligand has been developed because of the intrinsic advantages of Fluorine-18. Fluorine-18 labelled compounds are usually prepared in centers with an on-site cyclotron. Since our center has not an on-site cyclotron, we decided to verify the feasibility of producing the experimental 18F-labelled radiopharmaceutical [18F]F-PSMA-1007 with [18F]F- from different external suppliers. A quality agreement has been signed with two different suppliers, and a well-established and correctly implemented quality assurance protocol has been followed. The [18F]F- was produced with cyclotrons, on Nb target, but with different beam energy and current. Extensive validation of the [18F]F-PSMA-1007 synthesis process has been performed. The aim of this paper was the description of all the quality documentation which allowed the submission and approval of the Investigational Medicinal Product Dossier (IMPD) to the Competent Authority, addressing the quality problems due to different external suppliers. The result indicates that no significant differences have been found between the [18F]F- from the two suppliers in terms of radionuclidic and radiochemical purity and [18F]F- impacted neither the radiochemical yield of the labelling reaction nor the quality control parameters of the IMP [18F]F-PSMA-1007. These results prove how a correct quality assurance system can overcome some Regulatory Authorities issue that may represent an obstacle to the clinical use of F-18-labelled radiopharmaceuticals without an on-site cyclotron.

19.
Front Oncol ; 11: 601053, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34249671

RESUMO

PURPOSE: The objective of this study was to evaluate a set of radiomics-based advanced textural features extracted from 18F-FLT-PET/CT images to predict tumor response to neoadjuvant chemotherapy (NCT) in patients with locally advanced breast cancer (BC). MATERIALS AND METHODS: Patients with operable (T2-T3, N0-N2, M0) or locally advanced (T4, N0-N2, M0) BC were enrolled. All patients underwent chemotherapy (six cycles every 3 weeks). Surgery was performed within 4 weeks of the end of NCT. The MD Anderson Residual Cancer Burden calculator was used to evaluate the pathological response. 18F-FLT-PET/CT was performed 2 weeks before the start of NCT and approximately 3 weeks after the first cycle. The evaluation of PET response was based on EORTC criteria. Standard uptake value (SUV) statistics (SUVmax, SUVpeak, SUVmean), together with 148 textural features, were extracted from each lesion. Indices that are robust against contour variability (ICC test) were used as independent variables to logistically model tumor response. LASSO analysis was used for variable selection. RESULTS: Twenty patients were included in the study. Lesions from 15 patients were evaluable and analyzed: 9 with pathological complete response (pCR) and 6 with pathological partial response (pPR). Concordance between PET response and histological examination was found in 13/15 patients. LASSO logistic modelling identified a combination of SUVmax and the textural feature index IVH_VolumeIntFract_90 as the most useful to classify PET response, and a combination of PET response, ID range, and ID_Coefficient of Variation as the most useful to classify pathological response. CONCLUSIONS: Our study suggests the potential usefulness of FLT-PET for early monitoring of response to NCT. A model based on PET radiomic characteristics could have good discriminatory capacity of early response before the end of treatment.

20.
Front Oncol ; 11: 643469, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33859944

RESUMO

BACKGROUND: The presence of hypoxic cells in high-grade glioma (HGG) is one of major reasons for failure of local tumour control with radiotherapy (RT). The use of hyperbaric oxygen therapy (HBO) could help to overcome the problem of oxygen deficiency in poorly oxygenated regions of the tumour. We propose an innovative approach to improve the efficacy of hypofractionated stereotactic radiotherapy (HSRT) after HBO (HBO-RT) for the treatment of recurrent HGG (rHGG) and herein report the results of an ad interim analysis. METHODS: We enrolled a preliminary cohort of 9 adult patients (aged >18 years) with a diagnosis of rHGG. HSRT was administered in daily 5-Gy fractions for 3-5 consecutive days a week. Each fraction was delivered up to maximum of 60 minutes after HBO. RESULTS: Median follow-up from re-irradiation was 11.6 months (range: 3.2-11.6 months). The disease control rate (DCR) 3 months after HBO-RT was 55.5% (5 patients). Median progression-free survival (mPFS) for all patients was 5.2 months (95%CI: 1.34-NE), while 3-month and 6-month PFS was 55.5% (95%CI: 20.4-80.4) and 27.7% (95%CI: 4.4-59.1), respectively. Median overall survival (mOS) of HBO-RT was 10.7 months (95% CI: 7.7-NE). No acute or late neurologic toxicity >grade (G)2 was observed in 88.88% of patients. One patient developed G3 radionecrosis. CONCLUSIONS: HSRT delivered after HBO appears to be effective for the treatment of rHGG, it could represent an alternative, with low toxicity, to systemic therapies for patients who cannot or refuse to undergo such treatments. CLINICAL TRIAL REGISTRATION: www.ClinicalTrials.gov, identifier NCT03411408.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA