Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Front Cardiovasc Med ; 11: 1373310, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38601047

RESUMO

Objectives: Patients with atrial fibrillation (AF) have lower left atrial (LA) strain, which is a predictor for LA function. Here, we evaluated the prognostic value of LA strain to predict the rhythm outcome in patients with persistent AF undergoing LA cryoablation concomitant to minimally invasive mitral valve repair. Methods: Between 01/2016 and 12/2020, 72 patients with persistent AF underwent LA cryoablation during minimally invasive mitral valve surgery. All patients received a complete LA lesion set and left atrial appendage (LAA) closure with a clip. All patients received preoperative transthoracic echocardiography (TTE) with LA and left ventricular strain measurements. Preoperative LA and LV strain analysis was correlated with postoperative rhythm outcome. Results: The mean age of the patients was 66.9 ± 7.2 years, of whom 42 (58%) were male patients. No major ablation-related complications occurred in any of the patients. Successful LAA closure was confirmed by intraoperative echocardiography in all patients. The 1-year survival rate was 97%. Freedom from AF at 12 months was 72% and 68% off antiarrhythmic drugs. Preoperative LA strain values were statistically significantly higher in patients with freedom from AF at 12 months of follow-up (12.7% ± 6.9% vs. 4.9% ± 4.1%, p = 0.006). Preoperative LV strain value was not associated with postoperative rhythm outcome. In multivariate logistic regression analysis, LA strain (p < 0.001) and AF duration (p = 0.017) were predictors for freedom from AF at 12 months of follow-up. Conclusions: In our study, LA strain analysis predicted the rhythm outcome in patients with persistent AF undergoing concomitant surgical AF ablation. In the future, LA strain might be a useful tool to guide decision-making on ablation strategies in patients with persistent AF.

2.
Catheter Cardiovasc Interv ; 103(1): 194-201, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38037296

RESUMO

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) using balloon-expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients. METHODS: Between January 2016 and December 2022, 45 patients (100% male, 76.9 ± 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-3 definitions. RESULTS: Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (˂750 mm³) even in aortic annuli of 29.0-30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750-3200 mm³). Accordingly, a low calcification group (˂750 mm³, n = 17) compared to a significant calcification group (≥750 mm³, n = 28), presented with higher overfilling volumina (2.1 ± 1.4 vs. 0.8 ± 1.0; p ˂ 0.001), although aortic annulus diameter was not different (29.8 ± 0.8 vs. 29.9 ± 0.9 mm; p = 0.7). All-cause 30-day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 ± 3.6 mmHg. No case of PVL >mild was documented. CONCLUSION: Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex ˂750 mm³.


Assuntos
Estenose da Valva Aórtica , Calcinose , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/terapia , Desenho de Prótese
3.
Front Immunol ; 12: 761475, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34745137

RESUMO

Introduction: Sphingosine-1-phosphate (S1P) is a signaling lipid and crucial in vascular protection and immune response. S1P mediated processes involve regulation of the endothelial barrier, blood pressure and S1P is the only known inducer of lymphocyte migration. Low levels of circulatory S1P correlate with severe systemic inflammatory syndromes such as sepsis and shock states, which are associated with endothelial barrier breakdown and immunosuppression. We investigated whether S1P levels are affected by sterile inflammation induced by cardiac surgery. Materials and Methods: In this prospective observational study we included 46 cardiac surgery patients, with cardiopulmonary bypass (CPB, n=31) and without CPB (off-pump, n=15). Serum-S1P, S1P-sources and carriers, von-Willebrand factor (vWF), C-reactive protein (CRP), procalcitonin (PCT) and interleukin-6 (IL-6) were measured at baseline, post-surgery and at day 1 (POD 1) and day 4 (POD 4) after surgical stimulus. Results: Median S1P levels at baseline were 0.77 nmol/mL (IQR 0.61-0.99) and dropped significantly post-surgery. S1P was lowest post-surgery with median levels of 0.37 nmol/mL (IQR 0.31-0.47) after CPB and 0.46 nmol/mL (IQR 0.36-0.51) after off-pump procedures (P<0.001). The decrease of S1P was independent of surgical technique and observed in all individuals. In patients, in which S1P levels did not recover to preoperative baseline ICU stay was longer and postoperative inflammation was more severe. S1P levels are associated with its sources and carriers and vWF, as a more specific endothelial injury marker, in different phases of the postoperative course. Determination of S1P levels during surgery suggested that also the anticoagulative effect of heparin might influence systemic S1P. Discussion: In summary, serum-S1P levels are disrupted by major cardiac surgery. Low S1P levels post-surgery may play a role as a new marker for severity of cardiac surgery induced inflammation. Due to well-known protective effects of S1P, low S1P levels may further contribute to the observed prolonged ICU stay and worse clinical status. Moreover, we cannot exclude a potential inhibitory effect on circulating S1P levels by heparin anticoagulation during surgery, which would be a new pro-inflammatory pleiotropic effect of high dose heparin in patients undergoing cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Lisofosfolipídeos/sangue , Esfingosina/análogos & derivados , Idoso , Feminino , Humanos , Inflamação/sangue , Unidades de Terapia Intensiva , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Esfingosina/sangue
4.
Front Cardiovasc Med ; 8: 682321, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34368244

RESUMO

Objectives: Surgical exposure of groin vessels to establish cardiopulmonary bypass (CPB) for minimally-invasive valve surgery (MIS) is standard of care but may result in postoperative wound healing disorders or seroma formation. Therefore, adaption of transcatheter techniques for fully percutaneous insertion of CPB cannulae may improve clinical results. We herein analyze a single center experience with a novel plug-based vascular closure device for MIS. Methods: Between 03/2020 and 02/2021 MIS using the MANTA™ (Teleflex Medical Inc., Wayne, PA, USA) vascular closure device was performed in 28 consecutive patients (58.8 ± 10.6 years, 60.3% male, logEuroSCORE II 1.1 ± 0.8%) receiving mitral and/or tricuspid valve repair/replacement. Concomitant procedures were left atrial appendage occlusion and cryoablation for atrial fibrillation in 21.4% (6/28) and 10.7% (3/28) of patients, respectively. Data were retrospectively analyzed in accordance with standardized M-VARC definitions. MANTA™ device success and early safety was defined as absence of any access site or access related vascular injury and major and life-threatening bleeding complications. Results: MANTA™ device success with immediate hemostasis and early safety were 96.4% (27/28). In one case, device failure necessitated surgical cut down without further complications. Mean aortic cross clamp time and cardiopulmonary bypass were 96.5 ± 24.2 min and 150.2 ± 33.6 min. Stroke, renal failure or myocardial infarction were not observed. Intensive care unit and total hospital stay were 1.7 ± 0.8 days and 10.1 ± 5.7 days. Overall 30-day mortality was 0%. Post-procedure echocardiography presented one case of residual moderate tricuspid regurgitation and competent valves in all other cases. Conclusions: The MANTA™ device is safe and effective in MIS. Its ease of use and effectiveness to achieve immediate hemostasis have further simplified MIS.

5.
Thorac Cardiovasc Surg ; 69(5): 428-436, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32114689

RESUMO

BACKGROUND: We herein aimed for analysis of influence of mitral annular calcification (MAC) and mitral stenosis (MS) on outcomes in transcatheter aortic valve implantation (TAVI). METHODS: Between 11/2009 and 06/2017, 1,058 patients underwent TAVI in the presence of concomitant MAC or MS at our center. Subgroups were built and multivariate logistic regression, COX regression, Kaplan-Meier survival analyses, and receiver operating characteristics method were performed. RESULTS: Thirty-day mortality was 7.5% (79/1,058) with highest mortality in patients severe MS (MAC: 3.4% vs. mild MS: 5.9% vs. moderate MS: 15.0% vs. severe MS: 72.7%; p < 0.001). Moderate-to-severe MS (odds ratio [OR]: 7.75, confidence interval [CI]: 3.94-16.26, p < 0.001), impaired left ventricular ejection fraction (OR: 1.38, CI: 1.10-1.72, p < 0.01), and coronary artery disease (OR: 1.36, CI: 1.11-1.67, p < 0.01) were predictive of 30-day survival. Left ventricular systolic/end-diastolic pressure drop of <59.5 mm Hg / <19.5 mm Hg was associated with increased mortality. CONCLUSIONS: TAVI in the presence of MAC and mild MS is associated with acceptable acute outcomes but should be considered high-risk procedures in patients with moderate and especially those with severe MS. Our results suggest adverse hemodynamics after TAVI with concomitant MS, which may be caused by underfilling of the left ventricle leading to low-cardiac output.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Calcinose/fisiopatologia , Hemodinâmica , Estenose da Valva Mitral/fisiopatologia , Valva Mitral/fisiopatologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Feminino , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/mortalidade , Complicações Pós-Operatórias/etiologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
6.
Thorac Cardiovasc Surg Rep ; 8(1): e33-e36, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31692909

RESUMO

Background In patients treated by left ventricular assist device (LVAD), aortic regurgitation (AR) may occur. Secondary surgery to correct AR is considered high risk. Case Description We report a case of severe AR following LVAD implantation in a patient who was subsequently treated by transcatheter aortic valve implantation (TAVI) using the latest generation self-expandable transcatheter heart valve (THV) (Boston Scientific Acurate neo, size M [Boston Scientific, Marlborough, Massachusetts, United States]). TAVI followed modified procedural protocol and sizing algorithm. THV implantation without prior balloon aortic valvuloplasty resulted in an adequate valve function without leakage. Conclusion This THV may be particularly well suited for TAVI subsequent to LVAD implantation if modified sizing and deployment considerations are appreciated.

7.
Crit Care Med ; 43(7): 1423-8, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25844700

RESUMO

OBJECTIVES: Radial artery applanation tonometry allows completely noninvasive continuous cardiac output estimation. The aim of the present study was to compare cardiac output measurements obtained with applanation tonometry (AT-CO) using the T-Line system (Tensys Medical, San Diego, CA) with cardiac output measured by intermittent pulmonary artery thermodilution using a pulmonary artery catheter (PAC-CO) with regard to accuracy, precision of agreement, and trending ability. DESIGN: A prospective method comparison study. SETTING: The study was conducted in a cardiosurgical ICU of a German university hospital. PATIENTS: We performed cardiac output measurements in 50 patients after cardiothoracic surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Three independent sets of three consecutive thermodilution measurements (i.e., PAC-CO) each were performed per patient, and AT-CO was measured simultaneously. The average of the three thermodilution cardiac output measurements was compared with the average of the corresponding three AT-CO values resulting in 150 paired cardiac output measurements. In 13 patients, cardiac output-modifying maneuvers performed for clinical reasons additionally allowed to evaluate trending ability. For statistical analysis, we used Bland-Altman analysis, the percentage error, four-quadrant plot, and concordance analysis. Mean PAC-CO was 4.7 ± 1.2 L/min and mean AT-CO was 4.9 ± 1.1 L/min. The mean of differences was -0.2 L/min with 95% limits of agreement of -1.8 to + 1.4 L/min. The percentage error was 34%. The concordance rate was 95%. CONCLUSIONS: Continuous cardiac output measurement using the noninvasive applanation tonometry technology is basically feasible in ICU patients after cardiothoracic surgery. The applanation tonometry technology provides cardiac output values with reasonable accuracy and precision of agreement compared with intermittent pulmonary artery thermodilution measurements in a clinical study setting and is able to reliably track cardiac output changes induced by cardiac output-modifying maneuvers.


Assuntos
Débito Cardíaco , Procedimentos Cirúrgicos Cardíacos , Manometria , Cuidados Pós-Operatórios/métodos , Artéria Pulmonar , Artéria Radial/fisiologia , Termodiluição , Idoso , Feminino , Testes de Função Cardíaca/métodos , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA