Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38913845

RESUMO

This study developed a highly sensitive microbiological method utilizing a novel microtiter plate to screen 10 sulfonamides in chicken muscles, eggs, and prawns. This plate was fabricated from agar incorporating trimethoprim and spread with Bacillus megaterium. After residue detection by bioassay, the same test solutions were analyzed by LC-MS/MS for accurate identification and quantification. It also proved eco-friendly compared to using other quantitative methods. The residual drugs were extracted with McIlvaine buffer and purified using an Oasis® MCX cartridge. A triethylamine/methanol/water (0.5:75:24.5, v/v/v) mixture was used as the eluate. The obtained LOD values of the bioassay ranged from 5 to 25 µg kg-1 allowing the detection of the target drugs at the MRLs established in Japan. Adhering to ISO/IEC 17025 standards, the performance of the bioassay was evaluated. Based on the inhibition zone size in bioassay results, quality control yielded a Z score within ±2, indicating reasonable control over the screening process. Proficiency testing of a chicken muscle sample spiked with sulfadimidine demonstrated the inhibition zone detection of the bioassay and quantified value alignment of LC-MS/MS with reference values. In a surveillance study of 91 samples, sulfamethoxazole was detected in one prawn sample.

2.
Forensic Toxicol ; 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38519777

RESUMO

PURPOSE: The presence of cereulide, an emetic toxin produced by Bacillus cereus, in fried rice samples is critical evidence of food poisoning even in situations where B. cereus could not be detected. This study aims to develop a screening method for analyzing cereulide in fried rice using the QuEChERS procedure and liquid chromatography-tandem mass spectrometry (LC-MS/MS). METHODS: Cereulide was identified and quantified in fried rice samples using the QuEChERS extraction method and LC-MS/MS. The accuracies of the methods were determined by analyzing fortified blank samples at two concentrations (10 and 50 µg/kg) conducted on three samples daily for five days. RESULTS: The QuEChERS procedure removed matrix compounds from fried rice. Characteristic MS/MS spectra enabled the identification of cereulide. As the matrix effects in seven fried rice samples were within ± 6%, an external solvent calibration curve could be used for quantification. This method exhibited good accuracy ranging from 88 to 89%. The relative standard deviations for both repeatability and intra-laboratory reproducibility were < 4%. These standard deviations satisfied the criteria of the Japanese validation guidelines for residues (MHLW 2010, Director Notice, Syoku-An No. 1224-1). The limit of quantification was 2 µg/kg. The applicability of this method was confirmed using the analysis of cereulide in fried rice samples incubated with emetic Bacillus cereus. CONCLUSIONS: The QuEChERS extraction procedure described herein showed substantial promise as a reliable screening tool for cereulide in fried rice sample.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38252707

RESUMO

The simultaneous determination of five carbapenems (biapenem, doripenem, ertapenem, imipenem, and meropenem) in raw and pasteurised bovine milk samples using LC-MS/MS was achieved and validated. Chromatographic separation was conducted on an InertSustain® AQ-C18 column using 0.1% formic acid in water and acetonitrile as the mobile phase. Target compounds were extracted using acetonitrile/water (20:80, v/v). After the removal of lipids with acetonitrile-saturated hexane, the dissolved protein was denatured with acetic acid. A portion of the supernatant was passed through an Oasis® PRiME HLB cartridge to remove the matrix. This novel method was validated in accordance with the Japanese validation guidelines and exhibited good trueness, ranging from 86.3% to 96.2%, using matrix-matched calibration curves. The relative standard deviation of repeatability ranged from 1.0% to 6.3%, and that of within-laboratory reproducibility ranged from 1.6% to 7.1%. The limit of quantification was 1.0 µg kg-1 for all analytes. None of the 60 milk samples commercially available in Tokyo contained any analytes. This novel method exhibited high-quality performance and can easily be implemented for the routine monitoring of carbapenems, which are highly polar antibiotics in milk.


Assuntos
Antibacterianos , Carbapenêmicos , Animais , Antibacterianos/análise , Carbapenêmicos/análise , Cromatografia Líquida/métodos , Espectrometria de Massa com Cromatografia Líquida , Espectrometria de Massas em Tandem/métodos , Leite/química , Reprodutibilidade dos Testes , Acetonitrilas , Água/análise , Cromatografia Líquida de Alta Pressão/métodos
4.
Shokuhin Eiseigaku Zasshi ; 64(1): 53-60, 2023.
Artigo em Japonês | MEDLINE | ID: mdl-36858592

RESUMO

A method for the rapid analysis of multiclass residual veterinary drugs in poultry muscle, egg, and raw milk was validated in accordance with Japanese guidelines. Using LC-MS/MS, 20 veterinary drugs, including sulfonamides, coccidiostats, and macrolides were analyzed in one injection. Analytes were extracted from the samples with acetonitrile and then dehydrated and salted out using magnesium sulfate, trisodium citrate, and sodium chloride. This method was assessed by performing recovery tests of chicken muscle, duck muscle, egg, and raw milk spiked with 20 new target analytes at concentrations of 10 and 100 µg/kg. According to this method, 17 out of 20 target analytes satisfied the guideline criteria in chicken muscle and duck muscle, and all 20 target analytes met the criteria in egg and raw milk. The limit of quantification was less than MRLs for all analytes. Residues were detected in 4 out of 99 samples and analyzed using the validated method, finding that the levels of all residues were lower than the limits of quantification. These results suggest that continuous monitoring for a new trend of veterinary drugs is necessary.


Assuntos
Gado , Drogas Veterinárias , Animais , Cromatografia Líquida , Espectrometria de Massas em Tandem , Antibacterianos , Galinhas
5.
Artigo em Inglês | MEDLINE | ID: mdl-36848530

RESUMO

In this study, an immunochromatographic test (using the Charm QUAD2® Test) was used to screen for residual macrolides and lincosamides in raw cow's milk. The validation parameters (selectivity/specificity, detection capability (CCß), and ruggedness) were in agreement with the requirements of[EC] 2021. The selectivity of the immunochromatographic test was verified by the negative results of microbiological tests. The false-positive rate was 0%. The CCß values of the immunochromatographic test for various antibiotics in milk were as follows: erythromycin 0.02 mg/kg, spiramycin 0.1 mg/kg, tilmicosin 0.025 mg/kg, tylosin 0.05 mg/kg, lincomycin 0.15 mg/kg, and pirlimycin 0.15 mg/kg. The determined CCß values were lower than the respective maximum residue limits (MRLs; regulatory limits in Japan) for milk, except for lincomycin (equal to the MRL). The presence of antibiotic groups other than macrolides and lincosamides did not interfere with the specificity of the test. It showed no significant difference in lot-to-lot repeatability. The results obtained by the two researchers showed no significant differences. Finally, the test was applied to milk samples obtained from a tylosin-treated cow. The outcome was positive and in agreement with the results of the chemical analytical and microbiological methods. Therefore, this validated immunochromatographic test is expected to be suitable for routine analysis to ensure milk safety.


Assuntos
Resíduos de Drogas , Leite , Animais , Bovinos , Feminino , Lincosamidas/análise , Leite/química , Macrolídeos/análise , Tilosina/análise , Antibacterianos/análise , Lincomicina/análise , Resíduos de Drogas/análise
6.
Forensic Toxicol ; 41(2): 249-259, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36773219

RESUMO

PURPOSE: Detection of Clostridium perfringens enterotoxin (CPE) in human stool is critical evidence of food poisoning. However, processing patient-derived samples is difficult and very few methods exist to confirm the presence of CPE. In this study, a technique was developed using proteomic analysis to identify and quantify CPE in artificial gut fluid as an alternative. METHODS: The standard CPE was spiked into artificial gut fluids, and effective methods were developed by employing both a stable isotope-labelled internal standard peptide and liquid chromatography-tandem mass spectrometry (LC-MS/MS). RESULTS: Proteotypic peptide EILDLAAATER formed by tryptic digestion was selected for quantitation of CPE. The peptide was identified using product ion spectra. Although the nontoxic peptides originating from CPE showed very low detectability in extraction and tryptic digestion, they could be detected with sufficient sensitivity using the method we developed. Based on a spiked recovery test at two concentrations (50 and 200 µg/kg), the recovery values were 85 and 78%, respectively. The relative standard deviations of repeatability and within-laboratory reproducibility were less than 8 and 11%, respectively. These standard deviations satisfied the criteria of the Japanese validation guidelines for residues (MHLW 2010, Director Notice, Syoku-An No. 1224-1). The limit of quantification (LOQ) was estimated to be 50 µg/kg. The combination of the product ion spectra and relative ion ratio supported CPE identification at the LOQ level. CONCLUSIONS: To the best of our knowledge, this is the first report of proteomic analysis of CPE using LC-MS/MS. The method would greatly help in assessing CPE reliably.


Assuntos
Proteômica , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes , Peptídeos/análise , Isótopos
7.
Shokuhin Eiseigaku Zasshi ; 64(6): 246-252, 2023.
Artigo em Japonês | MEDLINE | ID: mdl-38171897

RESUMO

This study developed a method that simultaneously detected 283 pesticide residues in brown rice using GC-MS/MS and LC-MS/MS. In this method, we examined the desirable amount of sodium chloride required for salting out and the SPE cartridge required for clean-up. Pesticide residues from the sample were extracted with acetonitrile using a homogenizer and mixed with salts including anhydrous magnesium, two types of citrate, and sodium chloride. The sample solution of the acetonitrile layer was cleaned up using the GCB/NH2 (200 mg/200 mg, 6 mL) SPE cartridge. The determination method was validated using two concentrations (0.01 and 0.1 µg/g) of 283 pesticides based on the validation guideline of the Ministry of Health, Labor and Welfare in Japan. Of the 283 pesticides, 250 were detected satisfactorily. In addition, 59 brown rice samples sold in Tokyo were surveyed using the same method. Out of 44 samples, 12 pesticide residues below MRLs were detected. Therefore, this developed method is useful for the simultaneous determination of pesticide residues in brown rice.


Assuntos
Oryza , Resíduos de Praguicidas , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Espectrometria de Massa com Cromatografia Líquida , Resíduos de Praguicidas/análise , Cloreto de Sódio , Análise de Alimentos/métodos , Contaminação de Alimentos/análise , Acetonitrilas
8.
Shokuhin Eiseigaku Zasshi ; 63(2): 92-96, 2022.
Artigo em Japonês | MEDLINE | ID: mdl-35650034

RESUMO

By using the LC-MS/MS method developed by us, we determined the residual amounts of acaricides in honey samples commercially available in Tokyo from April 2015 to March 2021. The results of analyzing 127 honey samples, amitraz was detected in 85 samples at the level of 1.1-34.1 µg/kg. Propargite was detected in 3 samples at 2.4-3.8 µg/kg. None of them was beyond the Japanese MRLs or uniform limits. In these survey for 6 years, amitraz was detected in high rate throughout the year. But, the present results imply that amitraz has been used properly in actual bee-keeping because of no violation of MRL and less fluctuation in the detected levels. On the other hand, propargite was detected at the levels over LOQ in domestic honey samples for the first time in 2020, which may suggest a new trend of acaricide use in apiculture in Japan.


Assuntos
Acaricidas , Mel , Acaricidas/análise , Cromatografia Líquida/métodos , Mel/análise , Japão , Espectrometria de Massas em Tandem/métodos
9.
Shokuhin Eiseigaku Zasshi ; 62(4): 119-124, 2021.
Artigo em Japonês | MEDLINE | ID: mdl-34470940

RESUMO

A simultaneous determination method for caffeine, theobromine, and theophylline in chocolate was developed. Three compounds were ultrasonically extracted twice (15 min at 50℃) in an acetonitrile-water (1 : 1, v/v). The extract was purified using Oasis HLB SPE cartridge, and the purified processed by LC-MS. The method exhibited recoveries of 97.4-100.2%, RSDs of repeatability of 1.0-2.8%, and RSDs of within-laboratory reproducibility of 2.0-7.9%. This method was simpler and more selective than existing methods, and was practical for caffeine, theobromine, and theophylline analysis in chocolate.


Assuntos
Chocolate , Teobromina , Cafeína , Cromatografia Líquida , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Teofilina
10.
Food Addit Contam Part B Surveill ; 14(1): 66-73, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33441056

RESUMO

Residual antibacterial agents in 5909 animal and fishery products in Tokyo, Japan, were investigated over 17 consecutive years (2003-2019). Monitoring of 32 antibacterial agents (lincosamides, macrolides, penicillins, quinorones and tetracyclines) per product was accomplished via two steps: screening (by microbiological methods) and confirmation (by instrumental methods). Microbiological screening methods identified presumptive groups and determined semi-quantitative values. The instrumental methods quantified 81 residues of 11 different antibacterial agents in 72 samples. The screening strategy based on microbiological methods demonstrated the following: (i) the majority of the samples (over 99%) met Japanese regulations, (ii) using multiple methods provided a reliable inspection system with accurate quantitative values and (iii) there was a constant presence of tetracyclines and unexpected residues (lincomycin and norfloxacin) in various products. Thus, this long-term monitoring and screening strategy provided evidence that the frequencies and trends of residual antibacterial agents not only enhance food safety but also help to prevent antimicrobial resistance.


Assuntos
Antibacterianos , Pesqueiros , Animais , Antibacterianos/análise , Contaminação de Alimentos/análise , Tetraciclinas/análise , Tóquio
11.
Food Chem ; 338: 127712, 2021 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-32829295

RESUMO

Herein, a new method for quantifying the brominated vegetable oil content in commercial soft drinks was developed, which accelerated the sample preparation process and improved analytical efficiency. First, simple and accurate chromatographic separation techniques were performed using a VF-5ht column for both GC-FID (quantitative) and APGC-QTOF (qualitative) analyses. The samples were subjected to chromatography on a reversed-phase solid-phase extraction cartridge. (PoraPak™RxnRP). Transesterification using a boron trifluoride methanol complex in methanol solution was performed. When validating this method, the analyte recovery percentages were between 82.2% and 99.9%, and the recovery and standard deviation of repeatability values were between 1.2% and 3.5%. Using an isotope library, the bromostearic acid methyl esters (9,10-dibromostearic acid methyl ester, 9,10,12,13-tetrabromostearic acid methyl ester, and hexabromostearic acid methyl ester) in the sample mixtures were qualitatively confirmed via APGC-QTOF. A novel aqueous ammonium adduct, which has not been previously reported, was also confirmed. These results indicated that this new method was simple, accurate, and also allowed for precise qualitative and quantitative confirmation as well as high reproducibility.


Assuntos
Bebidas Gaseificadas/análise , Cromatografia Gasosa/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Óleos de Plantas/química , Ionização de Chama , Halogenação , Óleos de Plantas/isolamento & purificação , Reprodutibilidade dos Testes , Extração em Fase Sólida
12.
Shokuhin Eiseigaku Zasshi ; 61(4): 109-118, 2020.
Artigo em Japonês | MEDLINE | ID: mdl-33012764

RESUMO

The determination of antibacterial agents for animals in swine muscles was improved by microbiological screening and liquid chromatography-mass spectrometry (LC-MS/MS) analyses. In the first instance, the residual drugs were extracted from the samples using the Na2EDTA-McIlvaine buffer (pH 6.0). Subsequently, the agents were purified utilizing a PLS-3 cartridge and extracted with acetonitrile. Considering the microbiological methods, the sensitivities of the investigated drugs were higher and the test plate conditions were improved using a new reference organism Geobacillus stearothermophilus. As a result, a microbiological screening approach able to detect 33 drugs at MRL was developed in Japan. Remarkable, no false positives were detected. Moreover, the same preparation method enabled rapid and reliable microbiological screening, resulting in efficient screening with no undeterminable results.


Assuntos
Antibacterianos , Cromatografia Líquida , Análise de Alimentos , Músculo Esquelético , Espectrometria de Massas em Tandem , Animais , Antibacterianos/análise , Análise de Alimentos/métodos , Japão , Músculo Esquelético/química , Músculo Esquelético/microbiologia , Suínos
13.
Artigo em Inglês | MEDLINE | ID: mdl-32618500

RESUMO

Amygdalin, prunasin, total cyanide and free cyanide concentrations in 12 powdered loquat seeds were investigated. Loquat (Eriobotrya japonica) is a species of flowering plant in the family Rosaceae, and its fruit is quite popular in Japan. Amygdalin and prunasin were measured using LC-MS/MS. Total cyanide was measured by enzymatic treatment, steam distillation and colorimetric quantification using the pyridine-pyrazolone method. Free cyanide was measured without enzymatic treatment. The mean concentrations of amygdalin, prunasin, total cyanide and free cyanide in powdered loquat seeds were 5900, 760, 410 and 44 mg/kg, respectively. The range of each quantitative value was extensive. Seven out of twelve samples were at risk for exceeding the acute reference dose (ARfD) of cyanide.


Assuntos
Amigdalina/análise , Cianetos/análise , Eriobotrya/química , Nitrilas/análise , Pós/química , Sementes/química , Cromatografia Líquida , Espectrometria de Massas em Tandem
14.
Artigo em Inglês | MEDLINE | ID: mdl-32515305

RESUMO

In this study, we developed a reference labelled protein containing the partial amino acid sequence of botulinum neurotoxin type A (BoNTA). We also applied it as an internal standard to detect specific and non-toxic peptides originated from BoNTA in honey with the use of liquid chromatography-tandem mass spectrometry (LC-MS/MS). Original proteins in the honey sample were collected through a two-step process that included solubilisation and trichloroacetic acid (TCA) precipitation. Solubilisation by adding water enabled processing of proteins in honey. TCA precipitation collected proteins without specific binding. The combination of protein alkylation and an appropriate enzyme-to-protein ratio ensured feasibility of tryptic digestion. A desalting process eliminated a large amount of salts and other tryptic peptides in the honey sample. The use of the reference labelled protein enabled compensation for tryptic digestion efficiency and electrospray ionisation efficiency based on LC-MS/MS measurement. After the peptide selection and protein BlastP analysis, five unique peptides were chosen. The non-toxic peptides originating from BoNTA were reliably detected using LC-MS/MS based on a multiple-reaction monitoring mode. Detection of several peptides ensured screening of BoNTA in honey samples. Based on the responses, the proteotypic peptide LYGIAINPNR was selected as the quantitative peptide. Due to maintaining the relative ion ratios, the selective transition completely identified the non-toxic peptides. The intensity of the transitions established a detection limit of BoNTA estimated to be 9.4 ng mL-1. Although extraction efficiency was not evaluated using the BoNTA standard, the results suggested this method may be used for quantification of BoNTA in honey. The method was applied to 19 honey samples purchased in Tokyo; none of them was found to contain the target toxin. Overall, the method is expected to accelerate BoNTA monitoring for food safety.


Assuntos
Toxinas Botulínicas Tipo A/análise , Análise de Alimentos , Contaminação de Alimentos/análise , Mel/análise , Peptídeos/análise , Proteínas de Plantas/química , Cromatografia Líquida , Espectrometria de Massas em Tandem
15.
Shokuhin Eiseigaku Zasshi ; 61(6): 223-228, 2020.
Artigo em Japonês | MEDLINE | ID: mdl-33390530

RESUMO

A determination method for tributyltin (TBT) and triphenyltin (TPT) in fish and shellfish using an accelerated solvent extractor (ASE) and LC-MS/MS was developed. The chromatographic separation was conducted on a Poroshell 120 EC-C18 column using an isocratic mobile phase of 0.1% formic acid in 70% methanol. Sample preparation was performed using ASE at 125℃ with n-hexane and a cleanup using a Florisil cartridge. Internal calibration curves using deuterium-labeled TBT and TPT were employed for quantification. For both TBT and TPT, the calibration curves were linear in the range of 0.2-250 ng/mL, and the method quantification limits were 0.8 ng/g for both TBT and TPT. A National Institute for Environmental Studies certified reference material, No. 15 (adductor muscle of scallop), was analyzed to assess the performance of the developed method. The trueness, relative standard deviations of repeatability, and within laboratory reproducibility of this method, evaluated using a recovery test with four spiked fish species and one shellfish, ranged from 89.3 to 105.3%, 1.0 to 4.5%, and 1.3 to 7.6%, respectively.


Assuntos
Cromatografia Líquida , Peixes , Análise de Alimentos , Compostos Orgânicos de Estanho , Frutos do Mar , Espectrometria de Massas em Tandem , Compostos de Trialquitina , Animais , Poluentes Ambientais/análise , Análise de Alimentos/métodos , Limite de Detecção , Compostos Orgânicos de Estanho/análise , Reprodutibilidade dos Testes , Frutos do Mar/análise , Solventes/química , Compostos de Trialquitina/análise
16.
Shokuhin Eiseigaku Zasshi ; 60(3): 52-60, 2019.
Artigo em Japonês | MEDLINE | ID: mdl-31391411

RESUMO

We developed an analytical method for determining 15 antifungal drugs, 2 antiparasitic drugs, and 3 veterinary drugs in fish and livestock products using LC-MS/MS. First, 50% ethanol was added to their products, and the mixture was homogenized to reduce drug degradation. Thereafter, 20 drugs were extracted from the pretreated sample mixture using acetonitrile. Cleanup was performed using an alumina-N SPE cartridge. Finally, chromatographic separation was performed using a fully porous octadecyl silanized silica column. The new method is applicable to fish in which the matrix hampers accurate analysis. It was validated on 8 fish and livestock products. Drug recovery rates ranged from 70.2 to 109.3%, RSDs of repeatability were <18.0%, and RSDs of within-laboratory reproducibility were <18.7%. It fulfills the Japanese guideline criteria. The limits of quantification were estimated as 3 ng/g.


Assuntos
Antifúngicos/análise , Contaminação de Alimentos/análise , Carne/análise , Alimentos Marinhos/análise , Drogas Veterinárias/análise , Animais , Cromatografia Líquida , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
17.
Artigo em Inglês | MEDLINE | ID: mdl-31094669

RESUMO

In this study, the staphylococcal enterotoxin type A (SEA) contaminant was quantified in cow milk by liquid chromatography-tandem mass spectrometry (LC-MS/MS) with the use of a stable isotope-labelled peptide of SEA as an internal standard. SEA was cleaned up in a two-step process that included pH control and trichloroacetic acid (TCA) precipitation. The pH control phase eliminated other proteins. TCA precipitation cleaned up SEA without special equipment. An appropriate enzyme-to-protein ratio maximised tryptic digestion. A desalting process guaranteed the stable retention of SEA-digested peptides. The coverage of amino-acid sequences (>10%) clearly identified the toxin's presence. SEA was accurately quantified using LC-MS/MS based on a multiple-reaction monitoring mode. The developed method was validated based on spiked recovery tests at 50 and 100 µg kg-1 conducted with two samples collected on a daily basis for five days based on Japanese validation guidelines. The new method exhibited good accuracy which ranged from 80% to 82%. The relative standard deviations of repeatability were 13-14% and the relative standard deviations of within-laboratory reproducibility were 13-18%. These standard deviations satisfied the criteria of the Japanese validation guidelines. The quantification limit was estimated to be 10 µg kg-1.


Assuntos
Enterotoxinas/análise , Contaminação de Alimentos/análise , Leite/química , Peptídeos/química , Animais , Bovinos , Cromatografia Líquida , Marcação por Isótopo , Espectrometria de Massas em Tandem
18.
Artigo em Inglês | MEDLINE | ID: mdl-31100042

RESUMO

In this study, a new method was developed for simultaneously determining nine preservatives, that is, benzoic acid (BA), sorbic acid (SOA), dehydroacetic acid (DHA) and PHBAs (methyl p-hydroxybenzoate [PHBA-me], ethyl p-hydroxybenzoate [PHBA-et], isopropyl p-hydroxybenzoate [PHBA-ipro], propyl p-hydroxybenzoate [PHBA-npro]), isobutyl p-hydroxybenzoate [PHBA-ibut] and butyl p-hydroxybenzoate [PHBA-nbut]), in processed foods, employing liquid chromatography (LC). This procedure accelerated sample preparation and improved efficiency by employing modified quick, easy, cheap, effective, rugged and safe (QuEChERS) extraction without clean-up. Samples were prepared with 20 mL of acetonitrile/water (1:1) with the assistance of a ceramic stone. The extract solutions were diluted 10 times or according to the detection amount and then injected into an LC-PDA. This method showed good linearity, and the LOQs were 10 mg/kg for BA, SOA and DHA and 5 mg/kg for the PHBAs. When validating this method, the recoveries of the nine preservatives were in the range 77.0-99.6%, RSDr values were in the range 0.7-5.3% and those of RSDwr were in the range 2.3-8.4%. These results suggest that this new method is highly reproducible.


Assuntos
Conservantes de Alimentos/análise , Extração em Fase Sólida , Cromatografia Líquida de Alta Pressão
19.
Artigo em Inglês | MEDLINE | ID: mdl-30427268

RESUMO

We developed a method for the simultaneous determination of acaricides in comb honey using LC/MS/MS. Because methods for honey analysis had not previously been applied to comb honey, we modified three techniques for sample preparation and LC/MS/MS conditions. First, we used a modified QuEChERS method that changed the extraction solution from ethyl acetate to acetonitrile. Second, we replaced the InertSep® MA-1 (30 mg, 1 ml) clean-up cartridge with an Oasis® HLB (60 mg, 3 ml). Third, we changed the ionisation mode from ESI to atmospheric pressure chemical ionisation (APCI). With these modifications, sample matrices had no effect on the identification and quantification of analytes, using an external solvent calibration curve. We verified this new method with nine acaricides and two metabolites on comb honey and honey samples from three different honey origins. The trueness ranged from 74.0 to 99.4%. The relative standard deviation of repeatability (RSDr) ranged from 0.8 to 14.8% and that of within-laboratory reproducibility (RSDWR) ranged from 1.3 to 14.8%. All criteria met Japanese validation guidelines. The LOQ was 1.0 µg kg-1 for all analytes. We applied this method to 10 comb honey and 31 honey samples commercially available in Tokyo. From the results of the analysis of 41 samples, we observed that amitraz remained as N-(2,4-dimethylphenyl)-N-methylformamidine (DMPF) in 9 comb honey and 23 honey samples and that their residual concentrations were less than 20 µg kg-1. Using this new method, we improved recovery and precision, which enabled precise quantitative determination. Furthermore, the residual amitraz value in honey determined by both this new and the previous method were in good agreement.


Assuntos
Acaricidas/análise , Mel/análise , Acaricidas/metabolismo , Cromatografia Líquida , Espectrometria de Massas em Tandem
20.
Artigo em Inglês | MEDLINE | ID: mdl-30475679

RESUMO

In this study, the presence of cereulide in cow's milk was identified and quantified using our validated method with liquid chromatography-tandem mass spectrometry. Cereulide was concentrated using protein acid-precipitation and extracted from the precipitate by using acetonitrile twice. The combination of protein acid-precipitation and extraction sufficiently eliminated the matrix compounds from the milk and a further clean-up step utilising solid-phase extraction could be omitted. For robustly measuring the samples and keeping the MS devices clean, the extraction solution was diluted 10-fold using methanol. Owing to the minimisation of the interferences caused by fragmentation patterns, multiple reaction monitoring information-dependent acquisition-enhanced product ion spectra enabled the characterisation and identification of cereulide. Besides the matrix effect (-4%), an external solvent calibration curve was adapted for accurate quantification. The method was validated using fortified recovery tests, at two concentrations (10 and 50 µg kg-1), using three samples daily on five different days based on the Japanese guidelines. This new method exhibited good accuracy ranging from 91% to 94%. The relative standard deviations of repeatability ranged from 2% to 5%, and the relative standard deviation of within-laboratory reproducibility ranged from 5% to 6%. These standard deviations satisfied the criteria for the Japanese validation guidelines. The limit of quantification (LOQ) was estimated to be 2 µg kg-1. On the product ion spectra at the LOQ level, the library match was satisfactory with a purity fit value of >70%. The method was applied to 14 raw milk and three milk samples pasteurised using the low-temperature, long-time process and collected in Tokyo. None of the samples was found to contain the target toxin.


Assuntos
Depsipeptídeos/análise , Contaminação de Alimentos/análise , Leite/química , Animais , Calibragem , Bovinos , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA