Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38741377

RESUMO

PURPOSE: Derotational distal femoral osteotomy (DFO) is the causal treatment for patients with femoral torsional deformity. The fixation is achieved by a unilateral angle-stable plate. Delayed- or non-unions are one of the main risks of the procedure. An additional contralateral fixation may benefit the outcome. Therefore, we hypothesize that primary stability in DFO can be improved by an additional fixation with a hinge screw or an internal plate. METHODS: Derotational DFO was performed in 15 knees and fixed either with an angle-stable plate only (group 'None'), with an additional lateral screw (group 'Screw') or with an additional lateral plate (group 'Plate'). Biomechanical evaluation was carried out under axial loading of 150 N (partial weight bearing) and 800 N (full weight bearing), followed by internal and external rotation. After linear axial loading in step 1, a cyclic torsional load of 5 Nm was applied under constant axial load in step 2. In step 3, the specimens were unloaded. Micromovements between the distal and proximal parts of the osteotomy were recorded at each step for all specimens. RESULTS: In step 1, the extent of micromovements was highest in group 'None' and lowest in group 'Plate' without being significantly different. In step 2, group 'Plate' showed significantly higher stability, reflected by less rotation and lower micromovements. Increasing the axial load from 150 to 800 N at step 2 resulted in increased stability in all groups but only reached significance in group 'None'. CONCLUSION: An additional contralateral plate significantly increased stability in derotational DFO compared to the unilateral angle-stable plate only. Contrary, a contralateral hinge screw did not provide improved stability. STUDY DESIGN: Experimental study. LEVEL OF EVIDENCE: IV.

2.
Materials (Basel) ; 17(8)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38673194

RESUMO

Aseptic implant loosening after a total joint replacement is partially influenced by material-specific factors when cobalt-chromium alloys are used, including osteolysis induced by wear and corrosion products and stress shielding. Here, we aim to characterize a hybrid material consisting of alumina-toughened zirconia (ATZ) ceramics and additively manufactured Ti-35Nb-6Ta (TiNbTa) alloys, which are joined by a glass solder. The structure of the joint, the static and fatigue shear strength, the influence of accelerated aging, and the cytotoxicity with human osteoblasts are characterized. Furthermore, the biomechanical properties of the functional demonstrators of a femoral component for total knee replacements are evaluated. The TiNbTa-ATZ specimens showed a homogenous joint with statistically distributed micro-pores and a slight accumulation of Al-rich compounds at the glass solder-TiNbTa interface. Shear strengths of 26.4 ± 4.2 MPa and 38.2 ± 14.4 MPa were achieved for the TiNbTa-ATZ and Ti-ATZ specimens, respectively, and they were not significantly affected by the titanium material used, nor by accelerated aging (p = 0.07). All of the specimens survived 107 cycles of shear loading to 10 MPa. Furthermore, the TiNbTa-ATZ did not impair the proliferation and metabolic activity of the human osteoblasts. Functional demonstrators made of TiNbTa-ATZ provided a maximum bearable extension-flexion moment of 40.7 ± 2.2 Nm. The biomechanical and biological properties of TiNbTa-ATZ demonstrate potential applications for endoprosthetic implants.

3.
J Exp Orthop ; 11(1): e12011, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38497044

RESUMO

Purpose: Refixation of acute anterior cruciate ligament (ACL) tears represents an increasingly popular treatment option. Systematic evaluations of various suture technique parameters are still pending. We therefore aimed to evaluate the mechanical pull-out outcomes of various suture methods for optimization of ACL refixation. Methods: Sixty fresh knees from mature domestic pigs were dissected and the femoral attachment of the ACL was peeled off. The 60 knees were divided in 10 groups and sutured as follows: (A) one suture (1, 2, 4 and 6 passes), (B) two sutures (2, 4 and 6 passes each; sutures knotted together as a loop) and (C) two sutures (2, 4 and 6 passes each, sutures knotted separately). The pull-out test was conducted using a validated electrodynamic testing machine. First occurrence of failure, maximum pull-out load and stiffness were measured. Suture failure was defined as pull-out of the ACL. Results: Two-point fixation, using two sutures, with at least two passes, showed the most favourable biomechanical stability. The maximum pull-out load was significantly higher with two sutures (529.5 N) used compared to one (310.4 N), p < 0.001. No significant differences were found for maximum pull-out loads between two-point fixation versus one-point fixation but stiffness was significantly higher with two-point fixation (107.4 N/mm vs. 79.4 N/mm, p < 0.001). More passes resulted in higher maximum pull-out loads. Conclusion: The results suggest using two independent sutures, refixed separately and at least two suture passes, is appropriate for ACL refixation. More suture passes provide additional strength but are technically challenging to achieve during surgery. Level of Evidence: Level IV.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38511844

RESUMO

The influence of posterior cruciate ligament (PCL) tension on the clinical outcome of cruciate-retaining total knee replacement (CR-TKR) remains controversial. Various numerical approaches have been used to study this influence systematically, but the models used are limited by certain assumptions and simplifications. Therefore, the objective of this computational study was to develop a combined musculoskeletal multibody and finite-element simulation during a squat motion to 90° knee flexion with a CR-TKR design to overcome previous limitations regarding model inputs. In addition, different PCL tensions (tight, lax, resected) were modeled and the influence on tibiofemoral and resurfaced patellofemoral joint dynamics and contact stresses was evaluated. The effect of the PCL on knee joint dynamics and contact stresses was more pronounced at higher flexion angles. Tibiofemoral joint dynamics were influenced and a tight PCL induced increased posterior femoral translation during flexion. The maximum contact stress in the tibial insert increased from 20.6 MPa to 22.5 MPa for the resected and tightest PCL at 90° knee flexion. Patellofemoral joint dynamics were only slightly affected by PCL tension. However, the maximum contact stress in the patellar component decreased from 58.0 MPa to 53.7 MPa for the resected and tightest PCL at 90° knee flexion. The combination of musculoskeletal multibody and finite-element simulation is a sufficient method to comprehensively investigate knee joint dynamics and contact stresses in CR-TKR. The PCL tension after CR-TKR affects joint dynamics and contact stresses at the articulating implant surfaces.

5.
J Funct Biomater ; 15(2)2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38391899

RESUMO

The additive manufacturing of titanium-niobium-tantalum alloys with nominal chemical compositions Ti-xNb-6Ta (x = 20, 27, 35) by means of laser beam powder bed fusion is reported, and their potential as implant materials is elaborated by mechanical and biological characterization. The properties of dense specimens manufactured in different build orientations and of open porous Ti-20Nb-6Ta specimens are evaluated. Compression tests indicate that strength and elasticity are influenced by the chemical composition and build orientation. The minimum elasticity is always observed in the 90° orientation. It is lowest for Ti-20Nb-6Ta (43.2 ± 2.7 GPa) and can be further reduced to 8.1 ± 1.0 GPa for open porous specimens (p < 0.001). Furthermore, human osteoblasts are cultivated for 7 and 14 days on as-printed specimens and their biological response is compared to that of Ti-6Al-4V. Build orientation and cultivation time significantly affect the gene expression profile of osteogenic differentiation markers. Incomplete cell spreading is observed in specimens manufactured in 0° build orientation, whereas widely stretched cells are observed in 90° build orientation, i.e., parallel to the build direction. Compared to Ti-6Al-4V, Ti-Nb-Ta specimens promote improved osteogenesis and reduce the induction of inflammation. Accordingly, Ti-xNb-6Ta alloys have favorable mechanical and biological properties with great potential for application in orthopedic implants.

6.
Proc Inst Mech Eng H ; 237(10): 1154-1166, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37747115

RESUMO

Primary stability is crucial for implant osseointegration and the long-term stability of cementless total joint replacements. Biomechanical studies have shown the potential of femoral stems for total knee replacements to reduce micromotions at the bone-implant interface. However, approaches such as focusing on the structural elasticity of the femoral stems are rarely described. Three groups with different femoral stem designs were investigated: group 1: flexible surface stem, group 2: flexible surface stem with open-porous structured lamellas, and group 3: solid stem (reference). The stems were implanted into bone substitute material and dynamically loaded for 1000 cycles. Relative movement and subsidence were measured optically, and axial pull-out forces were determined after dynamic testing. Relative movements increased to 0.10 mm (groups 1 and 2) compared to 0.03 mm (group 3). Subsidence increased to 0.08 mm (group 1) and 0.11 mm (group 2) compared to 0.06 mm (group 3). For each group, subsidence mainly occurred during the first 500 cycles. A similar convergence was observed in the further course. Pull-out forces increased to 1815.0 N (group 1) and 1347.1 N (group 2) compared to 1306.4 N (group 3). The flexible surface stem design resulted in higher relative movements and subsidence, but also exhibited increased pull-out forces. The relative movements were below the critical limit of 0.15 mm and represent a superposition of the elastic deformations of the interacting implant components as well as the micromotion at the bone-implant interface. Therefore, the novel flexible surface stem design appears to offer promising primary implant fixation.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Prótese de Quadril , Desenho de Prótese , Osseointegração , Fêmur/cirurgia
7.
J Prosthodont ; 32(4): e71-e80, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35924927

RESUMO

PURPOSE: Zirconium dioxide ceramic has been successfully introduced as a framework material for fixed dental prostheses. To reduce manufacturing constraints, joining of subcomponents could be a promising approach to increase the mechanical performance of long-span fixed dental prostheses. In this experimental study, the biomechanical behavior of monolithic and soldered framework specimens for fixed dental prostheses made of Y-TZP was investigated. MATERIALS AND METHODS: Framework specimens (n = 80) of 5-unit fixed dental prostheses made of Y-TZP were prepared and divided into 10 equal groups. The specimens were monolithic or composed of subcomponents, which were joined using a silicate-based glass solder. Thereby, three joint geometries (diagonal, vertical with an occlusal cap, and dental attachment-based) were investigated. Moreover, the groups differed based on the mechanical test (static vs. dynamic) and further processing (veneered vs. unveneered). The framework specimens were cemented on alumina-based jaw models, where the canine and second molar were acting as abutments before a point-load was applied. In addition, µCT scans and microscopic fractography were used to evaluate the quality of soldered joints and to determine the causes of fracture. RESULTS: The determined fracture loads of the different unveneered framework specimens in static testing did not vary significantly (p = 1). Adding a veneering layer significantly increased the mechanical strength for monolithic framework specimens from 1196.29 ± 203.79 N to 1606.85 ± 128.49 N (p = 0.008). In case of soldered specimens with a dental attachment-based geometry, the mechanical strength increased from 1159.42 ± 85.65 N to 1249.53 ± 191.55 N (p = 1). Within the dynamic testing, no differences were observed between monolithic and soldered framework specimens. µCT scans and fractography proved that the dental attachment-based joining geometry offers the highest quality. CONCLUSION: Using glass soldering technology, subcomponents of 5-unit framework specimens made of Y-TZP could be joined with mechanical properties comparable to those of monolithic frameworks.


Assuntos
Materiais Dentários , Porcelana Dentária , Resistência à Flexão , Falha de Restauração Dentária , Facetas Dentárias , Teste de Materiais , Análise do Estresse Dentário , Cerâmica , Zircônio
8.
Biomed Res Int ; 2018: 6432742, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30175138

RESUMO

In the present study, a newly introduced bovine cross-linked collagen scaffold (test material) was investigated in vivo in an Achilles tendon defect model and compared to a commercially available porcine collagen scaffold (control material). In total, 28 male Sprague Dawley rats (about 400 g) were examined. The defined Achilles tendon defect of 5 mm of the right hind limb was replaced by one of the scaffold materials. After euthanasia, the hind limbs were transected for testing. Biomechanical evaluation was carried out via tensile testing (n = 8 each group, observation time: 28 days). Nonoperated tendons from the bilateral side were used as a control (native tendon, n = 4). For the histological evaluation, 12 animals were sacrificed at 14 and 28 days postoperatively (n = 3 each group and time point). Stained slices (Hematoxylin & Eosin) were evaluated qualitatively in terms of presence of cells and cell migration into scaffolds as well as structure and degradation of the scaffold. All transected hind limbs were additionally analyzed using MRI before testing to verify if the tendon repair using a collagen scaffold was still intact after the observation period. The maximum failure loads of both scaffold materials (test material: 54.5 ± 16.4 N, control: 63.1 ± 19.5 N) were in the range of native tendon (76.6 ± 11.6 N, p ≥ 0.07). The stiffness of native tendons was twofold higher (p ≤ 0.01) and the tear strength was approximately fivefold higher (p ≤ 0.01) compared to the repaired tendons with both scaffolds. Histological findings indicated that neither the test nor the control material induced inflammation, but the test material underwent a slower remodeling process. An overall repair failure rate of 48% was observed via MRI. The experimental data of the newly developed test material showed similar outcomes compared to the commercially available control material. The high repair failure rate indicated that MRI is recommended as an auxiliary measurement tool to validate experimental data.


Assuntos
Tendão do Calcâneo/patologia , Colágeno/química , Alicerces Teciduais , Cicatrização , Animais , Fenômenos Biomecânicos , Bovinos , Masculino , Ratos , Ratos Sprague-Dawley , Ruptura , Suínos , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA