Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Space Sci Rev ; 219(6): 46, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37636325

RESUMO

The Galileo mission to Jupiter revealed that Europa is an ocean world. The Galileo magnetometer experiment in particular provided strong evidence for a salty subsurface ocean beneath the ice shell, likely in contact with the rocky core. Within the ice shell and ocean, a number of tectonic and geodynamic processes may operate today or have operated at some point in the past, including solid ice convection, diapirism, subsumption, and interstitial lake formation. The science objectives of the Europa Clipper mission include the characterization of Europa's interior; confirmation of the presence of a subsurface ocean; identification of constraints on the depth to this ocean, and on its salinity and thickness; and determination of processes of material exchange between the surface, ice shell, and ocean. Three broad categories of investigation are planned to interrogate different aspects of the subsurface structure and properties of the ice shell and ocean: magnetic induction, subsurface radar sounding, and tidal deformation. These investigations are supplemented by several auxiliary measurements. Alone, each of these investigations will reveal unique information. Together, the synergy between these investigations will expose the secrets of the Europan interior in unprecedented detail, an essential step in evaluating the habitability of this ocean world.

2.
Exp Astron (Dordr) ; 54(2-3): 473-519, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36915623

RESUMO

The smallest characteristic scales, at which electron dynamics determines the plasma behaviour, are the next frontier in space and astrophysical plasma research. The analysis of astrophysical processes at these scales lies at the heart of the research theme of electron-astrophysics. Electron scales are the ultimate bottleneck for dissipation of plasma turbulence, which is a fundamental process not understood in the electron-kinetic regime. In addition, plasma electrons often play an important role for the spatial transfer of thermal energy due to the high heat flux associated with their velocity distribution. The regulation of this electron heat flux is likewise not understood. By focussing on these and other fundamental electron processes, the research theme of electron-astrophysics links outstanding science questions of great importance to the fields of space physics, astrophysics, and laboratory plasma physics. In this White Paper, submitted to ESA in response to the Voyage 2050 call, we review a selection of these outstanding questions, discuss their importance, and present a roadmap for answering them through novel space-mission concepts.

3.
Thorax ; 76(4): 380-386, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33593931

RESUMO

BACKGROUND: Multiple breath washout (MBW) using sulfur hexafluoride (SF6) has the potential to reveal ventilation heterogeneity which is frequent in patients with obstructive lung disease and associated small airway dysfunction. However, reference data are scarce for this technique and mostly restricted to younger cohorts. We therefore set out to evaluate the influence of anthropometric parameters on SF6-MBW reference values in pulmonary healthy adults. METHODS: We evaluated cross-sectional data from 100 pulmonary healthy never-smokers and smokers (mean 51 (SD 20), range 20-88 years). Lung clearance index (LCI), acinar (Sacin) and conductive (Scond) ventilation heterogeneity were derived from triplicate SF6-MBW measurements. Global ventilation heterogeneity was calculated for the 2.5% (LCI2.5) and 5% (LCI5) stopping points. Upper limit of normal (ULN) was defined as the 95th percentile. RESULTS: Age was the only meaningful parameter influencing SF6-MBW parameters, explaining 47% (CI 33% to 59%) of the variance in LCI, 32% (CI 18% to 47%) in Sacin and 10% (CI 2% to 22%) in Scond. Mean LCI increases from 6.3 (ULN 7.4) to 8.8 (ULN 9.9) in subjects between 20 and 90 years. Smoking accounted for 2% (CI 0% to 8%) of the variability in LCI, 4% (CI 0% to 13%) in Sacin and 3% (CI 0% to 13%) in Scond. CONCLUSION: SF6-MBW outcome parameters showed an age-dependent increase from early adulthood to old age. The effect was most pronounced for global and acinar ventilation heterogeneity and smaller for conductive ventilation heterogeneity. No influence of height, weight and sex was seen. Reference values can now be provided for all important SF6-MBW outcome parameters over the whole age range. TRIAL REGISTRATION NUMBER: NCT04099225.


Assuntos
Antropometria , Testes Respiratórios , Pneumopatias Obstrutivas/fisiopatologia , Hexafluoreto de Enxofre/análise , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Testes de Função Respiratória , Fumantes
4.
Am J Hypertens ; 34(4): 383-393, 2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33140085

RESUMO

BACKGROUND: Central blood pressure becomes increasingly accepted as an important diagnostic and therapeutic parameter. Accuracy of widespread applanation tonometry can be affected by calibration and operator training. To overcome this, we aimed to evaluate novel VascAssist 2 using automated oscillometric radial pulse wave analysis and a refined multi-compartment model of the arterial tree. METHODS: Two hundred and twenty-five patients were prospectively enrolled. Invasive aortic root measurements served as reference in MEASURE-cBP 1 (n = 106) whereas applanation tonometry (SphygmoCor) was used in MEASURE-cBP 2 (n = 119). RESULTS: In MEASURE-cBP 1, we found a mean overestimation for systolic values of 4 ± 12 mmHg (3 ± 10%) and 6 ± 10 mmHg (9 ± 14%) for diastolic values. Diabetes mellitus and low blood pressure were associated with larger variation. In MEASURE-cBP 2, mean overestimation of systolic values was 4 ± 4 mmHg (4 ± 4%) and 1 ± 4 mmHg (1 ± 7%) of diastolic values. Arrhythmia was significantly more frequent in invalid measurements (61 vs. 18%, P < 0.0001) which were most often due to a low quality index of SphygmoCor. CONCLUSIONS: Central blood pressure estimates using VascAssist 2 can be considered at least as accurate as available techniques, even including diabetic patients. In direct comparison, automated measurement considerably facilitates application not requiring operator training and can be reliably applied even in patients with arrhythmias.


Assuntos
Determinação da Pressão Arterial , Análise de Onda de Pulso , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Humanos , Oscilometria , Estudos Prospectivos , Artéria Radial/fisiologia , Reprodutibilidade dos Testes
5.
Sci Rep ; 10(1): 1527, 2020 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-32001782

RESUMO

Ventilation heterogeneity is frequent in bronchial asthma and can be assessed using multiple breath wash-out testing (MBW). Most data is available in paediatric patients and using nitrogen as a tracer gas. We aimed to evaluate sulphur hexafluoride (SF6) MBW in adult asthmatics. Spirometry, whole-body plethysmography, impulse oscillometry and SF6-MBW were prospectively performed. MBW parameters reflecting global (lung clearance index, LCI), acinar (Sacin) and conductive (Scond) ventilation heterogeneity were derived from three consecutive wash-outs. LCI was calculated for the traditional 2.5% and an earlier 5% stopping point that has the potential to reduce wash-out times. 91 asthmatics (66%) and 47 non-asthmatic controls (34%) were included in final analysis. LCI2.5 and LCI5 were higher in asthmatics (p < 0.001). Likewise, Sacin and Scond were elevated (p < 0.001 and p < 0.01). Coefficient of variation was 3.4% for LCI2.5 and 3.5% for LCI5 in asthmatics. Forty-one asthmatic patients had normal spirometry. ROC analysis revealed an AUC of 0.906 for the differentiation from non-asthmatic controls exceeding diagnostic performance of individual and conventional parameters (AUC = 0.819, p < 0.05). SF6-MBW is feasible and reproducible in adult asthmatics. Ventilation heterogeneity is increased as compared to non-asthmatic controls persisting in asthmatic patients with normal spirometry. Diagnostic performance is not affected using an earlier LCI stopping point while reducing wash-out duration considerably.


Assuntos
Ventilação Pulmonar/fisiologia , Testes de Função Respiratória/métodos , Hexafluoreto de Enxofre/metabolismo , Adulto , Idoso , Asma/diagnóstico , Asma/metabolismo , Asma/fisiopatologia , Testes Respiratórios/métodos , Estudos de Viabilidade , Feminino , Humanos , Pulmão/metabolismo , Masculino , Pessoa de Meia-Idade , Respiração , Espirometria/métodos
6.
Space Sci Rev ; 216(1): 9, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32025060

RESUMO

The icy satellites of Jupiter and Saturn are perhaps the most promising places in the Solar System regarding habitability. However, the potential habitable environments are hidden underneath km-thick ice shells. The discovery of Enceladus' plume by the Cassini mission has provided vital clues in our understanding of the processes occurring within the interior of exooceans. To interpret these data and to help configure instruments for future missions, controlled laboratory experiments and simulations are needed. This review aims to bring together studies and experimental designs from various scientific fields currently investigating the icy moons, including planetary sciences, chemistry, (micro-)biology, geology, glaciology, etc. This chapter provides an overview of successful in situ, in silico, and in vitro experiments, which explore different regions of interest on icy moons, i.e. a potential plume, surface, icy shell, water and brines, hydrothermal vents, and the rocky core.

7.
Biomed Rep ; 11(3): 98-102, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31423303

RESUMO

In postural stress, an increased preload volume leads to higher stroke volume (SV) according to the Frank-Starling law of the heart. The present study aimed to evaluate the hemodynamic response to postural stress using non-invasive inert gas rebreathing (IGR) in patients with normal as well as impaired left ventricular function. Hemodynamic measurements were performed in 91 patients undergoing cardiac magnetic resonance imaging (CMR). Mean cardiac output and SV determined by IGR were 4.4±1.3 l/min and 60±19 ml in the upright position, which increased significantly to 5.0±1.2 l/min and 75±23 ml in the supine position (P<0.01). Left ventricular systolic function was normal [ejection fraction (EF) ≥55%] in 42 patients as determined by CMR. In 21 patients, EF was mildly abnormal (45-54%), in 16 patients moderately abnormal (30-44%) and in 12 patients severely abnormal (<30%). An overall trend for a lower percentage change in SV (%ΔSV) was indicated with increasing impairment of ejection fraction. In patients with abnormal EF in comparison to those with normal EF, the %ΔSV was significantly lower (13% vs. 22%; P=0.03). Non-invasive measurement of cardiac function using IGR during postural changes may be feasible and detected significant difference in %ΔSV in patients with normal and impaired EF according to the Frank-Starling law of the heart. Several clinical scenarios including cases of heart rhythm disturbances or pulmonary or congenital heart disease are worthy of further investigation.

8.
J Clin Med ; 8(1)2019 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-30634565

RESUMO

In patients with chronic obstructive pulmonary disease (COPD), cardiovascular comorbidities are highly prevalent and associated with considerable morbidity and mortality. This coincidence is increasingly seen in context of a "cardiopulmonary continuum" rather than being simply attributed to shared risk factors such as cigarette smoking. Overlapping symptoms such as dyspnea or chest pain lead to a worse prognosis due to missed concomitant diagnoses. Moreover, medication is often withheld as a result of unfounded concerns about side effects. Despite the frequent coincidence, current guidelines are still mostly restricted to the management of the individual disease. Future diagnostic and therapeutic strategies should therefore be guided by an integrative perspective as well as a refined phenotyping of disease entities.

9.
J Clin Med ; 7(12)2018 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-30544842

RESUMO

Airways obstruction is frequent in patients with pulmonary hypertension (PH). Small airway disease (SAD) was identified as a major contributor to resistance and symptoms. However, it is easily missed using current diagnostic approaches. We aimed to evaluate more elaborate diagnostic tests such as impulse oscillometry (IOS) and SF6-multiple-breath-washout (MBW) for the assessment of SAD in PH. Twenty-five PH patients undergoing body-plethysmography, IOS and MBW testing were prospectively included and equally matched to pulmonary healthy and non-healthy controls. Lung clearance index (LCI) and acinar ventilation heterogeneity (Sacin) differed significantly between PH, healthy and non-healthy controls. Likewise, differences were found for all IOS parameters between PH and healthy, but not non-healthy controls. Transfer factor corrected for ventilated alveolar volume (TLCO/VA), frequency dependency of resistance (D5-20), resonance frequency (Fres) and Sacin allowed complete differentiation between PH and healthy controls (AUC (area under the curve) = 1.0). Likewise, PH patients were separated from non-healthy controls (AUC 0.762) by D5-20, LCI and conductive ventilation heterogeneity (Scond). Maximal expiratory flow (MEF) values were not associated with additional diagnostic values. MBW and IOS are feasible in PH patients both providing additional information. This can be used to discriminate PH from healthy and non-healthy controls. Therefore, further research targeting SAD in PH and evaluation of therapeutic implications is justified.

10.
Can Respir J ; 2018: 9493504, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29686742

RESUMO

Objectives: Diagnostic guidelines for chronic obstructive pulmonary disease (COPD) are based on spirometry and clinical criteria. However, this does not address the pathophysiological complexity of the disease sufficiently. Until now, inspiratory chest computed tomography (CT) has been considered as the preferred imaging method in these patients. We hypothesized that expiratory CT may be superior to demonstrate pathophysiological changes. The aim of this prospective study was to systematically compare lung function tests with quantified CT parameters in inspiration and expiration. Materials and Methods: Forty-six patients with diagnosed COPD underwent spirometry, body plethysmography, and dose-optimized CT in maximal inspiration and expiration. Four quantified CT parameters were acquired in inspiration, expiration, and their calculated delta values. These parameters were correlated with seven established lung function parameters. Results: For inspiratory scans, a weak-to-moderate correlation with the lung function parameters was found. These correlations significantly improved when adding the expiratory scan (p < 0.05). Moreover, some parameters showed a significant correlation only in expiratory datasets. Calculated delta values showed even stronger correlation with lung function testing. Conclusions: Expiratory quantified CT and calculated delta values significantly improve the correlation with lung function parameters. Thus, an additional expiratory CT may improve image-based phenotyping of patients with COPD.


Assuntos
Expiração , Pulmão/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Inalação , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Pletismografia Total , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Espirometria
11.
BMC Pulm Med ; 17(1): 185, 2017 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-29228942

RESUMO

BACKGROUND: Multiple breath washout (MBW) became a valuable research tool assessing ventilation heterogeneity. However, routine clinical application still faces several challenges. Deriving MBW parameters from three technically acceptable measurements according to current recommendations prolongs test times. We therefore aimed to evaluate reporting only duplicate measurements in healthy adults and pulmonary disease. METHODS: One hundred and fifty-three subjects prospectively underwent conventional lung function testing and closed-circuit SF6-MBW. Three technically acceptable MBW-measurements were obtained in 103 subjects. RESULTS: Lung clearance index (LCI) differed significantly among 19 controls (7.4 ± 0.8), 19 patients with sarcoidosis (8.1 ± 1.2), 32 with bronchial asthma (9.2 ± 1.9) and 33 with COPD (10.8 ± 2.2, p < 0.001). Within-test repeatability was high (coefficient of variation between 2.5% in controls and 3.6% in COPD) and remained unchanged when only including the first two measurements. Likewise, LCI remained stable with mean absolute changes ranging from 0.9 ± 0.8% in controls to 1.5 ± 0.9% in COPD (p = 0.1). Mean test time reduction differed significantly between groups reaching 200 s in COPD (p = 0.01). CONCLUSIONS: Duplicate SF6-MBW-measurements are sufficient in adult patients with pulmonary disease and healthy controls. LCI values and intra-test repeatability are not affected reducing total test time statistically significant. Our findings have the potential to further facilitate application of MBW in research and clinical routine. TRIAL REGISTRATION: NCT03176745 , June 2, 2017 retrospectively registered.


Assuntos
Asma/diagnóstico , Pulmão , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Sarcoidose Pulmonar/diagnóstico , Adulto , Feminino , Humanos , Pulmão/patologia , Pulmão/fisiopatologia , Masculino , Reprodutibilidade dos Testes , Testes de Função Respiratória/métodos
13.
Physiol Meas ; 37(9): 1422-35, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27480359

RESUMO

Electrical velocimetry (EV) is one of the most recent adaptions of impedance cardiography. Previous studies yielded diverging results identifying several factors negatively influencing accuracy. Although electrode arrangement is suspected to be an influencing factor for impedance cardiography in general, no data for EV is available. We aimed to prospectively assess the influence of electrode position on the accuracy and reproducibility of cardiac output (CO) measurements obtained by EV. Two pairs of standard electrocardiographic electrodes were placed at predefined positions of the thorax in 81 patients. The inter-electrode gap was varied between either 5 or 15 cm by caudal movement of the lowest electrode. Measurements were averaged over 20 s and performed twice at each electrode position. Reference values were determined using cardiac magnetic resonance imaging (CMR). Mean bias was 1.2 ± 1.6 l min(-1) (percentage error 22 ± 28%) between COCMR and COEV at the 5 cm gap significantly improving to 0.5 ± 1.6 l min(-1) (8 ± 28%) when increasing the gap (p < 0.0001). The mean difference between repeated measurements was 0.0 ± 0.3 l min(-1) for the 5 cm and 0.1 ± 0.3 l min(-1) for the 15 cm gap, respectively (p = 0.3). The accuracy of EV can be significantly improved when increasing the lower inter-electrode gap still exceeding the Critchley and Critchley recommendations. Therefore, absolute values should not be used interchangeably in clinical routine. As the reproducibility was not negatively affected, serial hemodynamic measurements can be reliably acquired in stable patients when the electrode position remains unchanged.


Assuntos
Débito Cardíaco , Reologia/instrumentação , Cardiografia de Impedância , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
14.
J Clin Monit Comput ; 30(4): 399-408, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26115774

RESUMO

A novel algorithm of impedance cardiography referred to as electrical velocimetry (EV) has been introduced for non-invasive determination of cardiac output (CO). Previous validation studies yielded diverging results and no comparison with the non-invasive gold standard cardiac magnetic resonance imaging (CMR) has been performed. We therefore aimed to prospectively assess the accuracy and reproducibility of EV compared to CMR. 152 consecutive stable patients undergoing CMR were enrolled. EV measurements were taken twice before or after CMR in supine position and averaged over 20 s (AESCULON(®), Osypka Medical, Berlin, Germany). Bland-Altman analysis showed insufficient agreement of EV and CMR with a mean bias of 1.2 ± 1.4 l/min (bias 23 ± 26 %, percentage error 51 %). Reproducibility was high with 0.0 ± 0.3 l/min (bias 0 ± 8 %, percentage error 15 %). Outlier analysis revealed gender, height, CO and stroke volume (SV) by CMR as independent predictors for larger variation. Stratification of COCMR in quintiles demonstrated a good agreement for low values (<4.4 l/min) with bias increasing significantly with quintile as high as 3.1 ± 1.1 l/min (p < 0.001). Reproducibility was not affected (p = 0.71). Subgroup analysis in patients with arrhythmias (p = 0.19), changes in thoracic fluid content (p = 0.51) or left heart failure (p = 0.47) could not detect significant differences in accuracy. EV showed insufficient agreement with CMR and good reproducibility. Gender, height and increasing CO and SV were associated with increased bias while not affecting reproducibility. Therefore, absolute values should not be used interchangeably in clinical routine. EV yet may find its place for clinical application with further investigation on its trending ability pending.


Assuntos
Débito Cardíaco , Cardiografia de Impedância/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas , Estatura , Impedância Elétrica , Feminino , Coração/fisiologia , Insuficiência Cardíaca , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Estudos Prospectivos , Reprodutibilidade dos Testes , Reologia/métodos , Volume Sistólico , Fatores de Tempo , Adulto Jovem
15.
Proc Natl Acad Sci U S A ; 111(48): E5123-32, 2014 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-25404343

RESUMO

We report far-ultraviolet observations of Jupiter's moon Europa taken by Space Telescope Imaging Spectrograph (STIS) of the Hubble Space Telescope (HST) in January and February 2014 to test the hypothesis that the discovery of a water vapor aurora in December 2012 by local hydrogen (H) and oxygen (O) emissions with the STIS originated from plume activity possibly correlated with Europa's distance from Jupiter through tidal stress variations. The 2014 observations were scheduled with Europa near the apocenter similar to the orbital position of its previous detection. Tensile stresses on south polar fractures are expected to be highest in this orbital phase, potentially maximizing the probability for plume activity. No local H and O emissions were detected in the new STIS images. In the south polar region where the emission surpluses were observed in 2012, the brightnesses are sufficiently low in the 2014 images to be consistent with any H2O abundance from (0-5)×10(15) cm(-2). Large high-latitude plumes should have been detectable by the STIS, independent of the observing conditions and geometry. Because electron excitation of water vapor remains the only viable explanation for the 2012 detection, the new observations indicate that although the same orbital position of Europa for plume activity may be a necessary condition, it is not a sufficient condition. However, the December 2012 detection of coincident HI Lyman-α and OI 1304-Å emission surpluses in an ∼200-km high region well separated above Europa's limb is a firm result and not invalidated by our 2014 STIS observations.


Assuntos
Meio Ambiente Extraterreno , Júpiter , Vapor , Água/análise , Exobiologia/métodos , Hidrogênio/análise , Hidrogênio/química , Gelo , Oxigênio/análise , Oxigênio/química , Telescópios , Água/química
16.
Science ; 343(6167): 171-4, 2014 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-24336567

RESUMO

In November and December 2012, the Hubble Space Telescope (HST) imaged Europa's ultraviolet emissions in the search for vapor plume activity. We report statistically significant coincident surpluses of hydrogen Lyman-α and oxygen OI 130.4-nanometer emissions above the southern hemisphere in December 2012. These emissions were persistently found in the same area over the 7 hours of the observation, suggesting atmospheric inhomogeneity; they are consistent with two 200-km-high plumes of water vapor with line-of-sight column densities of about 10(20) per square meter. Nondetection in November 2012 and in previous HST images from 1999 suggests varying plume activity that might depend on changing surface stresses based on Europa's orbital phases. The plume was present when Europa was near apocenter and was not detected close to its pericenter, in agreement with tidal modeling predictions.

17.
Lung ; 191(5): 467-73, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23884622

RESUMO

PURPOSE: Non-invasive inert gas rebreathing (IGR) has shown promising results in the determination of pulmonary blood flow. The volume of the rebreathing bag (V bag) is proposed by the system. However, elderly patients or those with severe pulmonary disease may be unable to rebreathe this volume entirely. We evaluated the effect of adapting V bag on the reproducibility of IGR. METHODS: A total of 270 valid measurements were obtained from 45 patients with obstruction (group A), restriction (group B), and in healthy controls (group C). Two measurements for each of three different V bag of 1,200, 1,700, and 2,200 ml were conducted in the supine position. RESULTS: We found no statistically significant difference of the repeated measurements neither between the different V bag in groups A to C nor between the three groups for identical V bag. There was a weak yet significantly worse coefficient of variation between a V bag of 2,200 ml in group A compared with group C with 2,200 and 1,200 ml, respectively. Intraclass correlation coefficient and repeatability coefficient yielded significantly worse values in group A for a V bag of 2,200 ml compared with healthy controls and lower bag volumes. No difference could be found intraclass nor interclass in groups B and C. CONCLUSIONS: V bag can be altered between 1,200 and 2,200 ml in most situations without affecting the reproducibility. Attention has to be paid to extreme volumes in obstructive patients. Nevertheless, V bag should be chosen as large as possible and therefore has to be carefully adapted, particularly in patients with obstruction or restriction.


Assuntos
Pneumopatias/fisiopatologia , Pulmão/irrigação sanguínea , Gases Nobres/metabolismo , Fluxo Sanguíneo Regional/fisiologia , Testes de Função Respiratória/métodos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estatura/fisiologia , Estudos de Casos e Controles , Feminino , Hemodinâmica/fisiologia , Humanos , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores Sexuais
18.
J Cardiothorac Vasc Anesth ; 27(2): 283-7, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23063946

RESUMO

OBJECTIVES: A growing interest in monitoring cardiac output (CO) noninvasively has emerged; however, its determination has been difficult using the standard approaches. The aim of this study was to evaluate the accuracy and precision of pulse contour analysis (PCA) compared with cardiac magnetic resonance imaging (CMR). DESIGN: A single-center prospective study. SETTING: A university hospital. PARTICIPANTS: Thirty-nine consecutive stable patients undergoing CMR. INTERVENTIONS: CO was determined twice by PCA using the Nexfin monitoring system (BMEYE BV, Amsterdam, The Netherlands). Measurements were performed after 10 minutes of rest in a stable supine position immediately before or after the CMR examination. MEASUREMENTS AND MAIN RESULTS: There was a mean bias of 0.2 ± 1.9 L/min between CMR and PCA and a reproducibility of 0.2 ± 0.6 L/min for PCA. Between 4.8 and 6.3 L/min (second quartile of COCMR), there was a good agreement (mean bias = -0.2 ± 1.3 L/min). Comparing quartile 1 (-1.3 ± 2.0 L/min) overestimating and quartiles 3 (1.4 ± 0.9 L/min) and 4 (0.9 ± 2.0 L/min) underestimating CO, a statistically significant difference was found. The reproducibility was not affected by the quartile (p = 0.23, analysis of variance), whereas there was a significant difference between the nonoutlier and outlier group when using the Mann-Whitney U test (p = 0.02). CONCLUSIONS: Noninvasive PCA allows the safe and economic measurement of CO, yet it still has major limitations. Although the agreement with CMR was acceptable, there was a clinically unacceptable variation; absolute values should not be used interchangeably. These results suggest that therapeutic interventions and clinical decisions should not be based on noninvasive PCA measurements at the present time.


Assuntos
Débito Cardíaco/fisiologia , Monitorização Intraoperatória/métodos , Idoso , Pressão Sanguínea/fisiologia , Interpretação Estatística de Dados , Eletrocardiografia , Feminino , Coração/anatomia & histologia , Coração/fisiologia , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/efeitos adversos , Técnicas de Patch-Clamp , Projetos Piloto , Estudos Prospectivos , Pulso Arterial , Reprodutibilidade dos Testes , Imagem Corporal Total
19.
Eur J Radiol ; 82(1): 100-5, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22749769

RESUMO

OBJECTIVE: To evaluate the impact of coronary CT angiography (coronary CTA) or "triple-rule-out" CT angiography (TRO-CTA) on patient management in the work-up of patients with acute chest pain and an intermediate cardiac risk profile. MATERIALS AND METHODS: 100 patients with acute chest pain and an intermediate cardiac risk for acute coronary syndrome (ACS) underwent coronary CTA or TRO-CTA for the evaluation of chest pain. Patients with a high and low cardiac risk profile were not included in this study. All patients with significant coronary stenosis >50% on coronary CTA underwent invasive coronary catheterization (ICC). Important other pathological findings were recorded. All patients had a 90-day follow-up period for major adverse cardiac events (MACE). RESULTS: Based on a negative coronary CTA 60 of 100 patients were discharged on the same day. None of the discharged patients showed MACE during the 90-day follow-up. Coronary CTA revealed a coronary stenosis >50% in 19 of 100 patients. ICC confirmed significant coronary stenosis in 17/19 patients. Among the 17 true positive patients, 9 underwent percutaneous coronary intervention with stent implantation, 7 were received intensified medical therapy, and 1 patient underwent coronary artery bypass surgery. A TRO-CTA protocol was performed in 36/100 patients due to elevated d-dimer levels. Pulmonary embolism was present in 5 patients, pleural effusion of unknown etiology in 3 patients, severe right ventricular dysfunction with pericardial effusion in 1 patient, and an incidental bronchial carcinoma was diagnosed in 1 patient. CONCLUSION: Coronary CTA and TRO-CTA allow a rapid and safe discharge in the majority of patients presenting with acute chest pain and an intermediate risk for ACS while at the same time identifies those with significant coronary artery stenosis.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/epidemiologia , Angiografia Coronária/estatística & dados numéricos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/epidemiologia , Gerenciamento Clínico , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Síndrome Coronariana Aguda/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Estenose Coronária/terapia , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Alta do Paciente , Prevalência , Medição de Risco
20.
In Vivo ; 26(6): 1027-33, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23160688

RESUMO

BACKGROUND: Doppler echocardiography is the method of choice for diagnosis and evaluation of aortic stenosis. However, there are well-known limitations to this method in difficult-to-image patients. Flow acceleration in the left ventricular outflow tract (LVOT) can lead to overestimation of stroke volume (SV) and poor acoustic windows may impede the exact measurement of the LVOT. The present study aimed to evaluate the use of inert gas rebreathing (IGR)-derived SV in this situation. PATIENTS AND METHODS: We replaced Doppler-derived SV measurements in the continuity equation (method A) by SV determined by IGR (method B) and by thermodilution during right heart catheterization (method C) to calculate the aortic valve area (AVA) in 21 consecutive patients with moderate or severe aortic stenosis. RESULTS: Mean SV and AVA did not differ between methods at 72±21 ml and 0.71±0.2 cm(2) (method A) vs. 66±18 ml and 0.67±0.21 cm(2) (method B) vs. 64±15 ml and 0.67±0.21 cm(2) (method C), respectively (all p-values >0.05). The mean difference and limits of agreement for AVA were 0.04±0.23 cm(2) and -0.40 to 0.47 cm(2) between methods A and B, 0.05±0.14 cm(2) and -0.26 to 0.27 cm(2) between A and C, and -0.05±0.23 cm(2) and -0.45 to 0.35 cm(2) between B and C, respectively (all p-values >0.05). CONCLUSION: The presented approach is a reliable method for the calculation of AVA and can add a diagnostic option for the use in difficult-to-image patients. Whereas the use of thermodilution is limited due to its invasive nature, IGR allows the fast and non-invasive determination of cardiac function at low cost.


Assuntos
Estenose da Valva Aórtica , Ecocardiografia Doppler , Gases Nobres/administração & dosagem , Volume Sistólico , Adulto , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/patologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Cateterismo Cardíaco , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Função Ventricular Esquerda/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA