Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
2.
Artigo em Alemão | MEDLINE | ID: mdl-36305898

RESUMO

BACKGROUND: Racism and structural discrimination in German healthcare have been little studied to date, although intercultural openness has been demanded for many years. At the same time, the processes of economization are progressing, especially in hospital care. This study examines current challenges of intercultural openness, including the influence of the economic framework. METHODS: One hundred twelve guided interviews were conducted with hospital employees in Berlin from various professional groups and departments. They were asked about challenges, how they were coping, and ideas for solutions. RESULTS: The consequences of economization are particularly visible in the care of patients with a history of flight or migration. A lack of resources combined with a lack of funding for language mediation leads to overburdening of healthcare workers and the tendency toward culturalization, in which the "culture" of the patients is used to explain their actions, and open racism. The breeding ground for this is the multiple insecurities experienced by staff due to the additional needs of these patients. Culturalization is described as an attempt to cope with their emotional distress in the face of lack of time and staff shortages. First and foremost, the wish for more time and additional staff was voiced. This being granted, further measures to reduce racism and structural discrimination were defined. DISCUSSION: In order to counteract racism and culturalization, measures that focus on the economic framework conditions and institutional change processes are central.


Assuntos
Racismo , Humanos , Racismo/psicologia , Alemanha , Atenção à Saúde , Pessoal de Saúde , Hospitais
3.
Molecules ; 27(3)2022 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-35164084

RESUMO

Nanocomposite materials have seen increased adoption in a wide range of applications, with toxic gas detection, such as carbon monoxide (CO), being of particular interest for this review. Such sensors are usually characterized by the presence of CO absorption sites in their structures, with the Langmuir reaction model offering a good description of the reaction mechanism involved in capturing the gas. Among the reviewed sensors, those that combined polymers with carbonaceous materials showed improvements in their analytical parameters such as increased sensitivities, wider dynamic ranges, and faster response times. Moreover, it was observed that the CO reaction mechanism can differ when measured in mixtures with other gases as opposed to when it is detected in isolation, which leads to lower sensitivities to the target gas. To better understand such changes, we offer a complete description of carbon nanostructure-based chemosensors for the detection of CO from the sensing mechanism of each material to the water solution strategies for the composite nanomaterials and the choice of morphology for enhancing a layers' conductivity. Then, a series of state-of-the-art resistive chemosensors that make use of nanocomposite materials is analyzed, with performance being assessed based on their detection range and sensitivity.

4.
Pharmaceuticals (Basel) ; 16(1)2022 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-36678545

RESUMO

Green chemistry is a pharmaceutical industry tool, which, when implemented correctly, can lead to a minimization in resource consumption and waste. An aqueous extract of Salix alba L. was employed for the efficient and rapid synthesis of silver/gold particle nanostructures via an inexpensive, nontoxic and eco-friendly procedure. The nanoparticles were physicochemically characterized using ultraviolet-visible spectroscopy (UV-Vis), Fourier transform infrared spectroscopy (FT-IR), dynamic light scattering (DLS), X-ray diffraction (XRD) and scanning electron microscopy (SEM), with the best stability of up to one year in the solution obtained for silver nanoparticles without any chemical additives. A comparison of the antimicrobial effect of silver/gold nanoparticles and their formulations (hydrogels, ointments, aqueous solutions) showed that both metallic nanoparticles have antibacterial and antibiofilm effects, with silver-based hydrogels having particularly high antibiofilm efficiency. The highest antibacterial and antibiofilm efficacies were obtained against Pseudomonas aeruginosa when using silver nanoparticle hydrogels, with antibiofilm efficacies of over 75% registered. The hydrogels incorporating green nanoparticles displayed a 200% increased bacterial efficiency when compared to the controls and their components. All silver nanoparticle formulations were ecologically obtained by "green synthesis" and were shown to have an antimicrobial effect or potential as keratinocyte-acting pharmaceutical substances for ameliorating infectious psoriasis wounds.

5.
Sensors (Basel) ; 21(5)2021 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-33807640

RESUMO

Developing a sensing layer with high electroactive properties is an important aspect for proper functionality of a wearable sensor. The polymeric nanocomposite material obtained by a simple electropolymerization on gold interdigitated electrodes (IDEs) can be optimized to have suitable conductive properties to be used with direct current (DC) measurements. A new layer based on polyaniline:poly(4-styrenesulfonate) (PANI:PSS)/single-walled carbon nanotubes (SWCNT)/ferrocene (Fc) was electrosynthesized and deposed on interdigital transducers (IDT) and was characterized in detail using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), scanning electron microscopy (SEM), Raman spectroscopy, X-ray photoemission spectroscopy (XPS), and X-ray diffraction (XRD). The sensor characteristics of the material towards carbon monoxide (CO) in the concentration range of 10-300 ppm were examined, showing a minimal relative humidity interference of only 1% and an increase of sensitivity with the increase of CO concentration. Humidity interference could be controlled by the number of CV cycles when a compact layer was formed and the addition of Fc played an important role in the decrease of humidity. The results for CO detection can be substantially improved by optimizing the number of deposition cycles and enhancing the Fc concentration. The material was developed for selective detection of CO in real environmental conditions and shows good potential for use in a wearable sensor.


Assuntos
Nanotubos de Carbono , Dispositivos Eletrônicos Vestíveis , Eletrodos , Ouro , Metalocenos
6.
Sensors (Basel) ; 21(6)2021 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-33809497

RESUMO

In recent years, research into the field of materials for flexible sensors and fabrication techniques directed towards wearable devices has helped to raise awareness of the need for new sensors with healthcare applicability. Our goal was to create a wearable flexible pressure sensor that could be integrated into a clinically approved blood pressure monitoring device. The sensor is built from a microfluidic channel encapsulated between two polymer layers, one layer being covered by metal transducers and the other being a flexible membrane containing the microfluidic channel, which also acts as a sealant for the structure. The applied external pressure deforms the channel, causing changes in resistance to the microfluidic layer. Electrical characterization has been performed in 5 different configurations, using alternating current (AC) and (DC) direct current measurements. The AC measurements for the fabricated pressure sensor resulted in impedance values at tens of hundreds of kOhm. Our sensor proved to have a high sensitivity for pressure values between 0 and 150 mm Hg, being subjected to repeatable external forces. The novelty presented in our work consists in the unique technological flow for the fabrication of the flexible wearable pressure sensor. The proposed miniaturized pressure sensor will ensure flexibility, low production cost and ease of use. It is made of very sensitive microfluidic elements and biocompatible materials and can be integrated into a wearable cuffless device for continuous blood pressure monitoring.


Assuntos
Dispositivos Eletrônicos Vestíveis , Pressão Sanguínea , Impedância Elétrica , Microfluídica , Monitorização Fisiológica
7.
Talanta ; 210: 120643, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-31987187

RESUMO

Two new biomimetic sensors for the detection of adiponectin (A) and leptin (L) through molecularly imprinted polymers (MIPs) onto gold working electrodes (GWEs) were fabricated. Based on electrochemical impedance spectroscopy (EIS) results and cyclic voltammetry (CV) characteristics recorded in the development stages of the fabricated sensors, the sensors were electrochemically optimized and used in an integrated microfluidic platform to detect adiponectin/leptin via conductance signals and non-imprinted electrodes were used as references. To overcome the limitation of the low response signals after template binding non-conductive polyphenol (PP) and poliscopoletin (PS) were used for templates formation. Under optimized experimental conditions the conductance and resistance signals were obtained in the linear range of 0-50 µg ml-1 for A and 1-32 ng∙ml-1 for L with low limits of detection (0.25 µg ml-1 for A and 0.110 ng ml-1 for L). The dedicated platform exhibited an excellent response with great selectivity and stability. Finally, the proposed biomimetic sensors were successfully applied to enable the determination of A and L in human patient's serum with very high accuracy when compared to enzyme-linked immunosorbent assay ELISA reference methods.


Assuntos
Adiponectina/sangue , Materiais Biocompatíveis/química , Técnicas Biossensoriais , Técnicas Eletroquímicas , Leptina/sangue , Técnicas Biossensoriais/instrumentação , Impedância Elétrica , Técnicas Eletroquímicas/instrumentação , Humanos
8.
Arch Med Sci ; 14(5): 1144-1154, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30154899

RESUMO

INTRODUCTION: We aim to highlight the utility of this model in the analysis of the psycho-behavioral implications of family cancer, presenting the scientific literature that used Leventhal's model as the theoretical framework of approach. MATERIAL AND METHODS: A systematic search was performed in six databases (EBSCO, ScienceDirect, PubMed Central, ProQuest, Scopus, and Web of Science) with empirical studies published between 2006 and 2015 in English with regard to the Common Sense Model of Self-Regulation (CSMR) and familial/hereditary cancer. The key words used were: illness representations, common sense model, self regulatory model, familial/hereditary/genetic cancer, genetic cancer counseling. The selection of studies followed the PRISMA-P guidelines (Moher et al., 2009; Shamseer et al., 2015), which suggest a three-stage procedure. RESULTS: Individuals create their own cognitive and emotional representation of the disease when their health is threatened, being influenced by the presence of a family history of cancer, causing them to adopt or not a salutogenetic behavior. Disease representations, particularly the cognitive ones, can be predictors of responses to health threats that determine different health behaviors. Age, family history of cancer, and worrying about the disease are factors associated with undergoing screening. No consensus has been reached as to which factors act as predictors of compliance with cancer screening programs. CONCLUSIONS: This model can generate interventions that are conceptually clear as well as useful in regulating the individuals' behaviors by reducing the risk of developing the disease and by managing as favorably as possible health and/or disease.

9.
Talanta ; 178: 910-915, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29136915

RESUMO

We describe the preparation and validation of a novel lateral flow immunoassay test for the detection of human heart fatty acid binding protein (hFABP). Water-soluble CdTe quantum dots (QDs) were selected as the fluorescent label and were linked covalently to anti-hFABP antibodies. Upon conjugation, the secondary structure of the anti-hFABP was preserved and the fluorescence quantum yield of the CdTe QDs increased. The labelled antibodies were transferred to the immunoassay test strip and the antigen-antibody reaction was successfully performed. This evidenced the preserved antibody activity of QD-labelled anti-hFABP towards hFABP, and provided a rapid means for the quantitation of hFABP in human serum within the range of 0-160ng ∙ ml-1, with a much lower detection limit of 221pg.∙ ml-1 compared with other rapid tests based on lateral flow immunoassays. This new immunoassay test has been successfully used for the early detection of acute myocardial infarction.


Assuntos
Análise Química do Sangue/métodos , Proteínas de Ligação a Ácido Graxo/sangue , Imunoensaio/métodos , Limite de Detecção , Pontos Quânticos/química , Animais , Compostos de Cádmio/química , Calibragem , Humanos , Modelos Lineares , Telúrio/química
10.
Talanta ; 132: 37-43, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25476276

RESUMO

The fabrication of a capacitive interdigitated immunosensor (CID) based on a mixed self-assembled monolayer (mSAM) film for the direct detection of heart fatty-acid binding protein (h-FABP) without any labeling is described. The capacitance changes of mSAMs vs. homogenous ordered self-assembled monolayers (hSAMs) on gold work electrodes/covalently bonded antibodies/buffered medium are utilized for monitoring the specific antibody-antigen interaction. Capacitance measurements in the absence and presence of Faradaic currents were performed. The electrochemical properties of mixed monolayers were compared with those of a pure monolayer of 11-mercaptoundecanoic acid (MUA) self-assembled on gold surfaces. Taking into account the stability of the studied monolayers during the electrochemical experiments with the Faradaic process, the best SAM functionalization method was used for developing a sensitive capacitive immunosensor with a non-Faradaic process for direct immune detection of human h-FABP. Under the optimized conditions, the proposed mixed self-assembled monolayer (mSAM1) on gold electrode exhibited good insulating properties such as a capacitive behavior when detecting h-FABP from human serum in the range of 98 pg ml(-1)-100 ng ml(-1), with a detection limit of 0.836 ng ml(-1) comparative with a homogenous self-assembled monolayer (hSAM).


Assuntos
Técnicas Eletroquímicas/instrumentação , Proteínas de Ligação a Ácido Graxo/sangue , Ouro/química , Imunoensaio/instrumentação , Miocárdio/química , Animais , Anticorpos/química , Capacitância Elétrica , Eletrodos , Ácidos Graxos/química , Humanos , Limite de Detecção , Camundongos , Reprodutibilidade dos Testes , Compostos de Sulfidrila/química
11.
Int J Mol Sci ; 14(2): 3011-25, 2013 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-23434655

RESUMO

The first step in determining whether a fluorescent dye can be used for antibody labeling consists in collecting data on its physical interaction with the latter. In the present study, the interaction between the 2-(2-hydroxy-5-nitrobenzylidene)-1,3-indanedione (HNBID) dye and the IgG1 monoclonal mouse antibody anti-human heart fatty acid binding protein (anti-hFABP) has been investigated by fluorescence and circular dichroism spectroscopies and complementary structural results were obtained by molecular modeling. We have determined the parameters characterizing this interaction, namely the quenching and binding constants, classes of binding sites, and excited state lifetimes, and we have predicted the localization of HNBID within the Fc region of anti-hFABP. The key glycosidic and amino acid residues in anti-hFABP interacting with HNBID have also been identified. A similar systematic study was undertaken for the well-known fluorescein isothiocyanate fluorophore, for comparison purposes. Our results recommend HNBID as a valuable alternative to fluorescein isothiocyanate for use as a fluorescent probe for IgG1 antibodies.

12.
Molecules ; 14(4): 1614-26, 2009 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-19396020

RESUMO

Binding of a newly synthesized indanedione derivative, 2-(2-hydroxy-3-ethoxybenzylidene)-1,3-indanedione (HEBID), to human and bovine serum albumins (HSA and BSA), under simulated physiological conditions was monitored by fluorescence spectroscopy. The binding parameters (binding constants and number of binding sites) and quenching constants were determined according to literature models. The quenching mechanism was assigned to a Förster non-radiative energy transfer due to the HEBID-SA complex formation. A slightly increased affinity of HEBID for HSA was found, while the number of binding sites is approximately one for both albumins. The molecular distance between donor (albumin) and acceptor (HEBID) and the energy transfer efficiency were estimated, in the view of Förster's theory. The effect of HEBID on the protein conformation was investigated using circular dichroism and synchronous fluorescence spectroscopies. The results revealed partial unfolding in the albumins upon interaction, as well as changes in the local polarity around the tryptophan residues.


Assuntos
Indanos/química , Soroalbumina Bovina/química , Albumina Sérica/química , Animais , Bovinos , Dicroísmo Circular , Transferência de Energia , Humanos , Estrutura Molecular , Ligação Proteica , Conformação Proteica , Espectrometria de Fluorescência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA