Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
2.
Pacing Clin Electrophysiol ; 47(8): 1079-1086, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-39031595

RESUMO

BACKGROUND: Identification of infrequent nonpulmonary vein trigger premature atrial contractions (PACs) is challenging. We hypothesized that pace mapping (PM) assessed by correlation scores calculated by an intracardiac pattern matching (ICPM) module was useful for locating PAC origins, and conducted a validation study to assess the accuracy of ICPM-guided PM. METHODS: Analyzed were 30 patients with atrial fibrillation. After pulmonary vein isolation, atrial pacing was performed at one or two of four sites on the anterior and posterior aspects of the left atrium (LA, n = 10/10), LA septum (n = 10), and lateral RA (n = 10), which was arbitrarily determined as PAC. The intracardiac activation obtained from each pacing was set as an ICPM reference consisting of six CS unipolar electrograms (CS group) or six CS unipolar electrograms and four RA electrograms (CS-RA group). RESULTS: The PM was performed at 193 ± 107 sites for each reference pacing site. All reference pacing sites corresponded to sites where the maximal ICPM correlation score was obtained. Sites with a correlation score ≥98% were rarely obtained in the CS-RA than CS group (33% vs. 55%, P = .04), but those ≥95% were similarly obtained between the two groups (93% vs. 88%, P = .71), and those ≥90% were obtained in all. The surface areas with correlation scores ≥98% (0[0,10] vs. 10[0,35] mm2, P = .02), ≥95% (10[10,30] vs. 50[10,180] mm2, P = .002) and ≥90% (60[30,100] vs. 170[100,560] mm2, P = .0002) were smaller in the CS-RA than CS group. CONCLUSIONS: ICPM-guided PM was useful for identifying the reference pacing sites. Combined use of RA and CS electrograms may improve the mapping quality.


Assuntos
Fibrilação Atrial , Veias Pulmonares , Humanos , Feminino , Masculino , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Veias Pulmonares/fisiopatologia , Idoso , Mapeamento Potencial de Superfície Corporal/métodos , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Técnicas Eletrofisiológicas Cardíacas/métodos , Sensibilidade e Especificidade , Átrios do Coração/fisiopatologia
3.
J Arrhythm ; 40(1): 57-66, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333379

RESUMO

Background: The effects of the patient's disease awareness on the management of postablation of atrial fibrillation (AF) are unknown. Methods: One hundred thirty-three AF patients undergoing an initial ablation were given a disease awareness questionnaire with a score of 16 points (8 points about AF in general and 8 points about oral anticoagulants) for the Jessa Atrial Fibrillation Knowledge Questionnaire (JAKQ) before and 1-year-after ablation. We divided them into the poor disease awareness group and good disease awareness group according to the median value (75%) of the total JAKQ score about AF in general, and compared the baseline patient characteristics and the 1-year changes in the JAKQ score, medication adherence, blood pressure, laboratory data, echocardiographic parameters, and AF/atrial tachycardia (AT) recurrence rate between the two groups. Results: Forty-two (31.6%) patients were classified as having poor disease awareness (<75% of the total JAKQ score), which was closely associated with poor medication adherence, hypertension, diabetes, dyslipidemia, and greater left atrial volume (LAV). These trends in the poor disease awareness group remained unchanged 1 year after the ablation. During the 25.3-month follow-up, the AF/AT recurrence rate was significantly higher in the poor disease awareness than the good disease awareness group (23.8% vs. 7.7%; p = .003 by the log-rank test). Conclusions: Poor disease awareness was linked to poor medication adherence, lifestyle-related diseases, and greater LAV before and even 1 year after the ablation, making it a potential surrogate marker for AF/AT recurrence. These findings highlight the clinical significance of disease awareness in AF management.

4.
J Arrhythm ; 39(3): 366-375, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37324765

RESUMO

Background: Ablation strategies and modalities for atrial fibrillation (AF) have transitioned over the past decade, but their impact on post-ablation medication and clinical outcomes remains to be fully investigated. Methods: We divided 682 patients who had undergone AF ablation in 2014-2019 (420 paroxysmal AFs [PAF], 262 persistent AFs [PerAF]) into three groups according to the period, that is, the 2014-2015 (n = 139), 2016-2017 (n = 244), and 2018-2019 groups (n = 299), respectively. Results: Persistent AF became more prevalent and the left atrial (LA) diameter larger over the 6 years. Extra-pulmonary vein (PV)-LA ablation was more frequently performed in the 2014-2015 group than in the 2016-2017 and 2018-2019 groups (41.1% vs. 9.1% and 8.1%; p < .001). The 2-year freedom rate from AF/atrial tachycardias for PAF was similar among the three groups (84.0% vs. 83.1% vs. 86.7%; p = .98) but lowest in the 2014-2015 group for PerAF (63.9% vs. 82.7% and 86.3%; p = .025) despite the highest post-ablation antiarrhythmic drug use. Cardiac tamponade was significantly decreased in the 2018-2019 group (3.6% vs. 2.0% vs. 0.33%; p = 0.021). There was no difference in the 2-year clinically relevant events among the three groups. Conclusion: Although ablation was performed in a more diseased LA and extra-PV-LA ablation was less frequent in recent years, the complication rate decreased, and AF recurrences for PAF remained unchanged, but that for PerAF decreased. Clinically relevant events remained unchanged over the recent 6 years, suggesting that the impact of the recent ablation modalities and strategies on remote clinically relevant events may be small during this study period.

5.
J Arrhythm ; 38(6): 1028-1034, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36524041

RESUMO

Background: A subeustachian pouch (SEP) often hinders the completion of a cavotricuspid isthmus (CTI) ablation of typical atrial flutter (AFL) and sometimes causes steam-pops during a power-controlled ablation. We hypothesized that real-time bull's-eye monitoring of the catheter surface temperature might be useful to locate the SEP where the temperature can rise rapidly, and a temperature-controlled ablation might avoid steam pops. This study aimed to demonstrate this hypothesis. Methods: A temperature-controlled CTI ablation with a QDOT MICRO™ catheter (n = 10) and a conventional power-controlled CTI ablation (n = 10) were performed with an output power of 35 W. During the RF application, the bull's eye monitor for monitoring the catheter surface temperatures was assessed. A "red-bull sign" was defined as an entire red-colored bull's-eye monitor, indicating that the catheter-tip temperature of all 6 thermocouples rose rapidly over 47°C. Results: In a total of 115 lesions (12 ± 3 per patient), a "red-bull sign" was observed in 39 (33.9%) lesions where the RF output was reduced to 26 ± 8 W. All 39 "red-bull sign" lesions corresponded to the location of the SEP as delineated by ICE before the ablation. The red-bull sign accurately indicated the presence of a SEP with a sensitivity of 84.7% and specificity of 100%. Bidirectional block of the CTI was completed in all patients in either catheter group without any steam-pops. Conclusion: Real-time surface temperature monitoring and a red-bull sign might be useful to detect the SEP. A temperature-controlled CTI ablation with the QDOT MICRO catheter might be safe for avoiding steam pops.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA