Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38535045

RESUMO

OBJECTIVES: The aim of this study was to analyze the extent of dental metal artifacts in virtual monoenergetic (VME) images, as they often compromise image quality by obscuring soft tissue affecting vascular attenuation reducing sensitivity in the detection of dissections. METHODS: Neck photon-counting CT datasets of 50 patients undergoing contrast-enhanced trauma CT were analyzed. Hyperattenuation and hypoattenuation artifacts, muscle with and without artifacts and vessels with and without artifacts were measured at energy levels from 40 keV to 190 keV. The corrected artifact burden, corrected image noise and artifact index were calculated. We also assessed subjective image quality on a Likert-scale. RESULTS: Our study showed a lower artifact burden and less noise in artifact-affected areas above the energy levels of 70 keV for hyperattenuation artifacts (conventional polychromatic CT images 1123 ± 625 HU vs. 70 keV VME 1089 ± 733 HU, p = 0.125) and above of 80 keV for hypoattenuation artifacts (conventional CT images -1166 ± 779 HU vs. 80 keV VME -1170 ± 851 HU, p = 0.927). Vascular structures were less hampered by metal artifacts than muscles (e.g., corrected artifact burden at 40 keV muscle 158 ± 125 HU vs. vessels -63 ± 158 HU p < 0.001), which was also reflected in the subjective image assessment, which showed better ratings at higher keV values and overall better ratings for vascular structures than for the overall artifact burden. CONCLUSIONS: Our research suggests 70 keV might be the best compromise for reducing metal artifacts affecting vascular structures and preventing vascular contrast if solely using VME reconstructions. VME imaging shows only significant effects on the general artifact burden. Vascular structures generally experience fewer metal artifacts than soft tissue due to their greater distance from the teeth, which are a common source of such artifacts.

2.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38535047

RESUMO

BACKGROUND: Photon-counting detector (PCD) computed tomography (CT) allows for the reconstruction of virtual monoenergetic images (VMI) at different thresholds. OBJECTIVE: The aim of our study was to evaluate the optimal arterial contrast in portal venous (pv) scans regarding objective parameters and subjective image quality for different virtual keV levels. METHODS: We identified 40 patients that underwent a CT scan with an arterial and pv phase on a PCD-CT (NAEOTOM alpha, Siemens Healthineers, Forchheim, Germany). The attenuation of abdominal arteries on pv phases was measured for different virtual keV levels in a monoenergetic+ application profile and for polychromatic (pc) arterial images. Two independent readers assessed subjective image quality, including vascular contrast in pv scans at different energy levels. Additionally, signal- and contrast-to-noise ratios (SNR and CNR) were measured. RESULTS: Our results showed increasing arterial attenuation levels with decreasing energy levels in virtual monoenergetic imaging on pv scans with the highest attenuation at 40 keV, significantly higher than in the pc arterial phase (439 ± 97 HU vs. 360 ± 97, p < 0.001). Noise, SNR, and CNR were worse at this energy level (p < 0.001). Pv VMI showed less noise at energy levels above 70 keV (all p < 0.001). Subjective image quality was rated best at 70 keV, vascular contrast was best at 40 keV. CONCLUSIONS: Our research suggests that virtual monoenergetic images at 40 keV in Mono+ mode derived from a PCD-CT can be a feasible alternative to a true arterial phase for assessment of vessels with worse CNR and SNR.

3.
J Dent ; 142: 104859, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38272436

RESUMO

OBJECTIVE: To investigate the image quality of a low-dose dental imaging protocol in the first clinical photon-counting computed tomography (PCCT) system in comparison to a normal-dose acquisition in a digital volume tomography (DVT) system. MATERIALS AND METHODS: Clinical PCCT systems offer an increased spatial resolution compared to previous generations of clinical systems. Their spatial resolution is in the order of dental DVT systems. Resolution-matched acquisitions of ten porcine jaws were performed in a PCCT (Naeotom Alpha, Siemens Healthineers) and in a DVT (Orthophos XL, Dentsply Sirona). PCCT images were acquired with 90 kV at a dose of 1 mGy CTDI16 cm. DVT used 85 kV at 4 mGy. Image reconstruction was performed using the standard algorithms of each system to a voxel size of 160 × 160 × 200 µm. The dose-normalized contrast-to-noise ratio (CNRD) was measured between dentine and enamel and dentine and bone. Two readers evaluated overall diagnostic quality of images and quality of relevant structures such as root channels and dentine. RESULTS: CNRD is higher in all PCCT acquisitions. CNRD is 37 % higher for the contrast dentine-enamel and 31 % higher for the dentine-bone contrast (p < 0.05). Overall diagnostic image quality was higher for PCCT over DVT (p < 0.02 and p < 0.04 for readers 1 and 2). Quality scores for anatomical structures were higher in PCCT compared to DVT (all p < 0.05). Inter- and intrareader reproducibility were acceptable (all ICC>0.64). CONCLUSIONS: PCCT provides an increased image quality over DVT even at a lower dose level and might enable complex dental imaging protocols in the future. CLINICAL SIGNIFICANCE: The evolution of photon-counting technology and it's optimization will increasingly move dental imaging towards standardized 3D visualizations providing both minimal radiation exposure and high diagnostic accuracy.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada por Raios X , Animais , Suínos , Reprodutibilidade dos Testes , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador
4.
J Clin Med ; 13(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38202274

RESUMO

OBJECTIVE: Fetal magnetic resonance imaging (MRI) is broadly used as a method for assessing prognosis in congenital diaphragmatic hernia (CDH). In addition to the extent of lung hypoplasia, determined by measuring the lung volume, cardiac impairment due to pulmonary hypertension and left cardiac hypoplasia is decisive for the prognosis. The percentage area of left ventricle (pALV) describes the percentage of the inner area of the left ventricle in relation to the total area, whereas the mediastinal shift angle (MSA) quantifies the extent of cardiac displacement. The prognostic value of pALV and MSA should be evaluated in terms of survival, the need for extracorporeal membrane oxygenation (ECMO) therapy, and the development of chronic lung disease (CLD). METHODS: In a total of 122 fetal MRIs, the MSA and pALV were measured retrospectively and complete outcome parameters were determined regarding survival for all 122 subjects, regarding ECMO therapy in 109 cases and about the development of CLD in 78 cases. The prognostic value regarding the endpoints was evaluated using logistic regression and ROC analysis. RESULTS: The MSA was significantly higher in children who received ECMO therapy (p = 0.0054), as well as in children who developed CLD (p = 0.0018). ROC analysis showed an AUC of 0.68 for ECMO requirement and 0.77 with respect to CLD development. The pALV showed a tendency towards higher levels in children who received ECMO therapy (p = 0.0824). The MSA and the pALV had no significant effect on survival (MSA: p = 0.4293, AUC = 0.56; pALV: p = 0.1134, AUC = 0.57). CONCLUSIONS: The MSA determined in fetal MRI is a suitable prognostic parameter for ECMO requirement and CLD development in CDH patients and can possibly be used as a supplement to the established parameters.

5.
Rofo ; 196(3): 262-272, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37944935

RESUMO

With personalized tumor therapy, understanding and addressing the heterogeneity of malignant tumors is becoming increasingly important. Heterogeneity can be found within one lesion (intralesional) and between several tumor lesions emerging from one primary tumor (interlesional). The heterogeneous tumor cells may show a different response to treatment due to their biology, which in turn influences the outcome of the affected patients and the choice of therapeutic agents. Therefore, both intra- and interlesional heterogeneity should be addressed at the diagnostic stage. While genetic and biological heterogeneity are important parameters in molecular tumor characterization and in histopathology, they are not yet addressed routinely in medical imaging. This article summarizes the recently established markers for tumor heterogeneity in imaging as well as heterogeneous/mixed response to therapy. Furthermore, a look at emerging markers is given. The ultimate goal of this overview is to provide comprehensive understanding of tumor heterogeneity and its implications for radiology and for communication with interdisciplinary teams in oncology. KEY POINTS:: · Tumor heterogeneity can be described within one lesion (intralesional) or between several lesions (interlesional).. · The heterogeneous biology of tumor cells can lead to a mixed therapeutic response and should be addressed in diagnostics and the therapeutic regime.. · Quantitative image diagnostics can be enhanced using AI, improved histopathological methods, and liquid profiling in the future..


Assuntos
Neoplasias , Humanos , Neoplasias/diagnóstico por imagem , Neoplasias/genética , Neoplasias/terapia , Diagnóstico por Imagem , Oncologia , Radiografia
6.
Rofo ; 196(2): 186-194, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37922942

RESUMO

PURPOSE: Analysis of clinical and diagnostic findings in rare urogenital and perineal vascular malformations only occurring in 2-3 % of vascular anomalies with regard to clinical symptoms and treatment decisions. MATERIALS AND METHODS: All 25 out of 537 patients presenting with congenital urogenital and perineal vascular malformations at our institution from 2014 to 2021 were included. Vascular anomaly classification, anatomical location, clinical symptoms at presentation, diagnostic imaging, and pain intensity were retrospectively assessed from the patient record and therapy management was evaluated. RESULTS: In total, 25 patients (10 females (40 %), 15 males (60 %)), aged 6 to 77 years were included. Diagnoses were: 10 (40 %) venous malformations (VMs), 5 (20 %) lymphatic malformations (LMs) and 10 (40 %) arteriovenous malformations (AVMs). Malformation manifestations were: 12 (32 %) lesser pelvis, 12 (32 %) external genitalia, and 13 (34 %) perineal/gluteal region. One AVM was located in the kidney. The leading clinical symptom was pain. The mean intensity was 6.0/10 for LM, 5.7/10 for VM, and 4.5/10 for AVM. Further major symptoms included physical impairment, local swelling, and skin discoloration. Bleeding complications or sexual dysfunction were rare findings. Patients with VM reported significantly more symptoms than patients with AVM (p = 0.0129). In 13 patients (52 %) minimally invasive therapy was indicated: 10 (77 %) sclerotherapies and 3 (23 %) transcatheter embolization procedures. Complete symptomatic remission was achieved in 9 (69 %) patients, partial response in 3 (23 %) patients, and 1 patient showed no clinical response to therapy. Follow-up appointments without the need for immediate minimally invasive therapy were significantly more common in patients with AVMs than in patients with VMs (p = 0.0198). CONCLUSION: To create a higher awareness of congenital urogenital and perineal vascular malformations. Awareness of this rare condition avoids misdiagnosis. Therapy decisions should be symptom-oriented. Emergency intervention is rarely required, even in fast-flow vascular malformations. KEY POINTS: · Venous malformations cause more symptoms with higher pain intensity than arteriovenous malformations.. · Diagnosis and adequate treatment can be hampered by a lack of awareness of the clinical presentation.. · Bleeding complications are rare, even in high-flow vascular malformations.. · Pain and physical impairment are the most commonly observed symptoms in these patients..


Assuntos
Malformações Arteriovenosas , Malformações Vasculares , Masculino , Feminino , Humanos , Estudos Retrospectivos , Malformações Vasculares/diagnóstico por imagem , Malformações Vasculares/terapia , Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/terapia , Diagnóstico por Imagem , Dor , Resultado do Tratamento
7.
Rofo ; 196(1): 25-35, 2024 Jan.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37793417

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS: · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT: · Hagen F, Soschynski M, Weis M et al. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25 - 34.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Criança , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Tórax , Imagens de Fantasmas , Pulmão
9.
Sci Rep ; 13(1): 14806, 2023 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-37684412

RESUMO

Accurate small vessel stent visualization using CT remains challenging. Photon-counting CT (PCD-CT) may help to overcome this issue. We systematically investigate PCD-CT impact on small vessel stent assessment compared to energy-integrating-CT (EID). 12 water-contrast agent filled stents (3.0-8 mm) were scanned with patient-equivalent phantom using clinical PCD-CT and EID-CT. Images were reconstructed using dedicated vascular kernels. Subjective image quality was evaluated by 5 radiologists independently (5-point Likert-scale; 5 = excellent). Objective image quality was evaluated by calculating multi-row intensity profiles including edge rise slope (ERS) and coefficient-of-variation (CV). Highest overall reading scores were found for PCD-CT-Bv56 (3.6[3.3-4.3]). In pairwise comparison, differences were significant for PCD-CT-Bv56 vs. EID-CT-Bv40 (p ≤ 0.04), for sharpness and blooming respectively (all p < 0.05). Highest diagnostic confidence was found for PCD-CT-Bv56 (p ≤ 0.2). ANOVA revealed a significant effect of kernel strength on ERS (p < 0.001). CV decreased with stronger PCD-CT kernels, reaching its lowest in PCD-CT-Bv56 and highest in EID-CT reconstruction (p ≤ 0.05). We are the first study to verify, by phantom setup adapted to real patient settings, PCD-CT with a sharp vascular kernel provides the most favorable image quality for small vessel stent imaging. PCD-CT may reduce the number of invasive coronary angiograms, however, more studies needed to apply our results in clinical practice.


Assuntos
Prótese Vascular , Doença da Artéria Coronariana , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Diagnóstico por Imagem , Imagens de Fantasmas , Humanos , Doença da Artéria Coronariana/terapia
10.
Diagnostics (Basel) ; 13(8)2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37189555

RESUMO

BACKGROUND: To compare the diagnostic characteristics between arterial phase imaging versus portal venous phase imaging, applying polychromatic T3D images and low keV virtual monochromatic images using a 1st generation photon-counting CT detector, of CT in patients with hepatocellular carcinoma (HCC). METHODS: Consecutive patients with HCC, with a clinical indication for CT imaging, were prospectively enrolled. Virtual monoenergetic images (VMI) were reconstructed at 40 to 70 keV for the PCD-CT. Two independent, blinded radiologists counted all hepatic lesions and quantified their size. The lesion-to-background ratio was quantified for both phases. SNR and CNR were determined for T3D and low VMI images; non-parametric statistics were used. RESULTS: Among 49 oncologic patients (mean age 66.9 ± 11.2 years, eight females), HCC was detected in both arterial and portal venous scans. The signal-to-noise ratio, the CNR liver-to-muscle, the CNR tumor-to-liver, and CNR tumor-to-muscle were 6.58 ± 2.86, 1.40 ± 0.42, 1.13 ± 0.49, and 1.53 ± 0.76 in the arterial phase and 5.93 ± 2.97, 1.73 ± 0.38, 0.79 ± 0.30, and 1.36 ± 0.60 in the portal venous phase with PCD-CT, respectively. There was no significant difference in SNR between the arterial and portal venous phases, including between "T3D" and low keV images (p > 0.05). CNRtumor-to-liver differed significantly between arterial and portal venous contrast phases (p < 0.005) for both "T3D" and all reconstructed keV levels. CNRliver-to-muscle and CNRtumor-to-muscle did not differ in either the arterial or portal venous contrast phases. CNRtumor-to-liver increased in the arterial contrast phase with lower keV in addition to SD. In the portal venous contrast phase, CNRtumor-to-liver decreased with lower keV; whereas, CNRtumor-to-muscle increased with lower keV in both arterial and portal venous contrast phases. CTDI and DLP mean values for the arterial upper abdomen phase were 9.03 ± 3.59 and 275 ± 133, respectively. CTDI and DLP mean values for the abdominal portal venous phase were 8.75 ± 2.99 and 448 ± 157 with PCD-CT, respectively. No statistically significant differences were found concerning the inter-reader agreement for any of the (calculated) keV levels in either the arterial or portal-venous contrast phases. CONCLUSIONS: The arterial contrast phase imaging provides higher lesion-to-background ratios of HCC lesions using a PCD-CT; especially, at 40 keV. However, the difference was not subjectively perceived as significant.

11.
Rofo ; 195(8): 691-698, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36863367

RESUMO

BACKGROUND: Photon-counting computed tomography (PCCT) is a promising new technology with the potential to fundamentally change today's workflows in the daily routine and to provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The content of this review is based on an unrestricted literature search on PubMed and Google Scholar using the search terms "Photon-Counting CT", "Photon-Counting detector", "spectral CT", "Computed Tomography" as well as on the authors' experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCCT allows counting of every single photon at the detector level. Based on the identified literature, PCCT phantom measurements and initial clinical studies have demonstrated that the new technology allows improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, radiation dose reduction, and the use of new contrast agents. In this review, we will discuss basic technical principles and potential clinical benefits and demonstrate first clinical use cases. KEY POINTS: · Photon-counting computed tomography (PCCT) has been implemented in the clinical routine. · Compared to energy-integrating detector CT, PCCT allows the reduction of electronic image noise. · PCCT provides increased spatial resolution and a higher contrast-to-noise ratio. · The novel detector technology allows the quantification of spectral information. CITATION FORMAT: · Stein T, Rau A, Russe MF et al. Photon-Counting Computed Tomography - Basic Principles, Potenzial Benefits, and Initial Clinical Experience. Fortschr Röntgenstr 2023; 195: 691 - 698.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
12.
Invest Radiol ; 58(3): 199-208, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36070524

RESUMO

OBJECTIVE: Before implementing radiomics in routine clinical practice, comprehensive knowledge about the repeatability and reproducibility of radiomic features is required. The aim of this study was to systematically investigate the influence of image processing parameters on radiomic features from magnetic resonance imaging (MRI) in terms of feature values as well as test-retest repeatability. MATERIALS AND METHODS: Utilizing a phantom consisting of 4 onions, 4 limes, 4 kiwifruits, and 4 apples, we acquired a test-retest dataset featuring 3 of the most commonly used MRI sequences on a 3 T scanner, namely, a T1-weighted, a T2-weighted, and a fluid-attenuated inversion recovery sequence, each at high and low resolution. After semiautomatic image segmentation, image processing with systematic variation of image processing parameters was performed, including spatial resampling, intensity discretization, and intensity rescaling. For each respective image processing setting, a total of 45 radiomic features were extracted, corresponding to the following 7 matrices/feature classes: conventional indices, histogram matrix, shape matrix, gray-level zone length matrix, gray-level run length matrix, neighboring gray-level dependence matrix, and gray-level cooccurrence matrix. Systematic differences of individual features between different resampling steps were assessed using 1-way analysis of variance with Tukey-type post hoc comparisons to adjust for multiple testing. Test-retest repeatability of radiomic features was measured using the concordance correlation coefficient, dynamic range, and intraclass correlation coefficient. RESULTS: Image processing influenced radiological feature values. Regardless of the acquired sequence and feature class, significant differences ( P < 0.05) in feature values were found when the size of the resampled voxels was too large, that is, bigger than 3 mm. Almost all higher-order features depended strongly on intensity discretization. The effects of intensity rescaling were negligible except for some features derived from T1-weighted sequences. For all sequences, the percentage of repeatable features (concordance correlation coefficient and dynamic range ≥ 0.9) varied considerably depending on the image processing settings. The optimal image processing setting to achieve the highest percentage of stable features varied per sequence. Irrespective of image processing, the fluid-attenuated inversion recovery sequence in high-resolution overall yielded the highest number of stable features in comparison with the other sequences (89% vs 64%-78% for the respective optimal image processing settings). Across all sequences, the most repeatable features were generally obtained for a spatial resampling close to the originally acquired voxel size and an intensity discretization to at least 32 bins. CONCLUSION: Variation of image processing parameters has a significant impact on the values of radiomic features as well as their repeatability. Furthermore, the optimal image processing parameters differ for each MRI sequence. Therefore, it is recommended that these processing parameters be determined in corresponding test-retest scans before clinical application. Extensive repeatability, reproducibility, and validation studies as well as standardization are required before quantitative image analysis and radiomics can be reliably translated into routine clinical care.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas
13.
BMC Med Imaging ; 22(1): 214, 2022 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-36471287

RESUMO

BACKGROUND: Uterine fibroid embolisation (UFE) is an established treatment method for symptomatic uterine myomas. This study evaluates the efficacy of UFE using objective magnetic resonance imaging (MRI) data for size and perfusion analysis as well as patient questionnaires assessing fibroid-related symptoms. METHOD: Patients underwent MR-Angiography before UFE and 4 days, 6 and 12 months after the procedure. The images were evaluated using dedicated software. Patient questionnaires were completed before UFE and at 12 months follow-up, focussing on the embolization procedure and symptoms associated with uterine fibroids. Statistical analysis of the questionnaires was performed using paired sample t-test and Wilcoxon signed rank test, while Kruskal-Wallis test and Friedman test were applied for MRI-analysis. RESULTS: Eleven women were included. There was a significant reduction in fibroid-related symptoms. The volume reduction after 12 months was significant in both, uterus and myomas, after an initial increase in uterine volume at the first post-interventional MRI. The perfusion analysis showed that blood flow to the fibroids could be significantly reduced up to 12 months after UFE while uterine tissue was not affected. CONCLUSION: This study shows that uterine fibroid embolisation induces a significant long-term decrease in myoma size and perfusion while healthy uterine tissue remains unaffected. Fibroid-related symptoms are reduced for the sake of improved quality of life.


Assuntos
Leiomioma , Mioma , Neoplasias Uterinas , Humanos , Feminino , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/terapia , Qualidade de Vida , Resultado do Tratamento , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Inquéritos e Questionários , Imageamento por Ressonância Magnética/métodos , Perfusão
14.
Eur Radiol ; 32(11): 7409-7419, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35482122

RESUMO

OBJECTIVES: Abbreviated breast MRI (AB-MRI) was introduced to reduce both examination and image reading times and to improve cost-effectiveness of breast cancer screening. The aim of this model-based economic study was to analyze the cost-effectiveness of full protocol breast MRI (FB-MRI) vs. AB-MRI in screening women with dense breast tissue for breast cancer. METHODS: Decision analysis and a Markov model were designed to model the cumulative costs and effects of biennial screening in terms of quality-adjusted life years (QALYs) from a US healthcare system perspective. Model input parameters for a cohort of women with dense breast tissue were adopted from recent literature. The impact of varying AB-MRI costs per examination as well as specificity on the resulting cost-effectiveness was modeled within deterministic sensitivity analyses. RESULTS: At an assumed cost per examination of $ 263 for AB-MRI (84% of the cost of a FB-MRI examination), the discounted cumulative costs of both MR-based strategies accounted comparably. Reducing the costs of AB-MRI below $ 259 (82% of the cost of a FB-MRI examination, respectively), the incremental cost-effectiveness ratio of FB-MRI exceeded the willingness to pay threshold and the AB-MRI-strategy should be considered preferable in terms of cost-effectiveness. CONCLUSIONS: Our preliminary findings indicate that AB-MRI may be considered cost-effective compared to FB-MRI for screening women with dense breast tissue for breast cancer, as long as the costs per examination do not exceed 82% of the cost of a FB-MRI examination. KEY POINTS: • Cost-effectiveness of abbreviated breast MRI is affected by reductions in specificity and resulting false positive findings and increased recall rates. • Abbreviated breast MRI may be cost-effective up to a cost per examination of 82% of the cost of a full protocol examination. • Abbreviated breast MRI could be an economically preferable alternative to full protocol breast MRI in screening women with dense breast tissue.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico , Mamografia/métodos , Densidade da Mama , Detecção Precoce de Câncer/métodos , Programas de Rastreamento , Imageamento por Ressonância Magnética/métodos , Análise Custo-Benefício , Anos de Vida Ajustados por Qualidade de Vida
15.
Rofo ; 194(1): 29-38, 2022 01.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-34139781

RESUMO

BACKGROUND: Diagnostic radiological examinations as well as interventional radiological therapies are performed at a steadily increasing rate amidst increasingly limited resources in healthcare systems. Given their potential to contribute decisively to optimized therapy, in most cases associated short-term direct costs can be well justified from a clinical perspective. However, to realize their clinical benefits, they must also succeed in justifying them to payers and policymakers. Therefore, the aim of this work is to present suitable methods for economic analysis of radiological precedures and to elaborate their relevance for radiology. METHODOLOGY: Methods and metrics of cost-effectiveness analysis are presented and then exemplified using the example cases of MR mammography and interventional treatment of oligometastatic tumor disease of the liver. RESULTS: Cost-effectiveness considerations, taking into account long-term gains in lifespan and quality of life, as well as potential savings through improved treatment planning, do often objectively and credibly justify short-term additional costs. CONCLUSIONS: Cost-effectiveness analyses performed with radiological and health economic expertise can support the establishment of new radiological technologies in diagnostics and therapy. KEY POINTS: · When radiological procedures are employed, short-term costs are often offset by significant long-term benefits.. · Radiological examinations and therapies must be justified in the context of limited economic resources.. · Economic methodologies can be used to quantify the quality and cost-effectiveness of radiological methods.. · Such analyses as well as targeted training should be encouraged to provide greater transparency.. CITATION FORMAT: · Froelich MF, Kunz WG, Tollens F et al. Cost-effectiveness analysis in radiology: methods, results and implications. Fortschr Röntgenstr 2022; 194: 29 - 38.


Assuntos
Qualidade de Vida , Radiologia Intervencionista , Análise Custo-Benefício , Mamografia , Radiografia
17.
Vasa ; 50(6): 468-474, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34269078

RESUMO

Background: In peripheral arterial disease (PAD) the femoropopliteal (FP) artery is the most frequently recanalized lower limb artery. Stent-based interventions change the biomechanical properties of FP arteries. However, no clinical tool for functional imaging is established for quantitative measurements in vivo. Four-dimensional-flow magnetic resonance imaging enables a detailed evaluation of the hemodynamics of the central and - more challenging - the peripheral arteries. The present study aimed to determine the feasibility of assessing pulse wave velocities (PWV) as a marker of vessel stiffness in PAD patients with multiple spot stents and to compare the values with age-matched subjects and young-adult healthy subjects. Patients and methods: Contrast-free 4D-flow MRI was performed in seven PAD patients with focally stented FP arteries, five age-matched subjects after exclusion of PAD, and five young, healthy adults. PWV values were calculated from flow curves by using the foot-to-foot method. Results: Four-D-flow MRI sequences offering high spatial and temporal resolution enables quantification of flow velocity measurements and estimation of PWVs. Assessment of segmental PWV as a surrogate of vascular stiffness in focally stented femoral arteries is feasible. PWV values across all groups were 15.6±5.2 m/s, 13.3±4.1 m/s, and 9.9±2.2 m/s in PAD patients, senior-aged volunteers, and young-adult volunteers respectively. PWV values in PAD patients were similar with those in the senior-aged volunteers group (15.6±5.2 vs. 13.3 ±4.1 years, p=0.43). However, when compared to the young-adult volunteers, PAD patients had a statistically significantly higher mean local PWV (15.6±5.2 m/s vs. 9.9±2.2 m/s, p<0.05). Conclusions: Calculating segmental PWV in the femoral arteries is feasible in PAD patients with focally stented FP arteries. PWV values in PAD patients were similar to those in senior-aged volunteers, both of which were higher than in young-adult volunteers.


Assuntos
Análise de Onda de Pulso , Rigidez Vascular , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Artéria Femoral/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Stents
18.
EJNMMI Radiopharm Chem ; 6(1): 22, 2021 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-34228236

RESUMO

BACKGROUND: [68Ga]Ga-NeoB is a novel DOTA-coupled Gastrin Releasing Peptide Receptor (GRPR) antagonist with high affinity for GRPR and good in vivo stability. This study aimed at (1) the translation of preclinical results to the clinics and establish the preparation of [68Ga]Ga-NeoB using a GMP conform kit approach and a licensed 68Ge/68Ga generator and (2) to explore the application of [68Ga]Ga-NeoB in patients with gastrointestinal stromal tumors (GIST) before and/or after interventional treatment (selective internal radiotherapy, irreversible electroporation, microwave ablation). RESULTS: Validation of the production and quality control of [68Ga]Ga-NeoB for patient use had to be performed before starting the GMP production. Six independent batches of [68Ga]Ga-NeoB were produced, all met the quality and sterility criteria and yielded 712 ± 73 MBq of the radiotracer in a radiochemical purity of > 95% and a molar activity of 14.2 ± 1.5 GBq/µmol within 20 min synthesis time and additional 20 min quality control. Three patients (2 females, 1 male, 51-77 yrs. of age) with progressive gastrointestinal stromal tumor metastases in the liver or peritoneum not responsive to standard tyrosine kinase inhibitor therapy underwent both [68Ga]Ga-NeoB scans prior and after interventional therapy. Radiosynthesis of 68Ga-NeoB was performed using a kit approach under GMP conditions. No specific patient preparation such as fasting or hydration was required for [68Ga]Ga-NeoB PET/CT imaging. Contrast-enhanced PET/CT studies were performed. A delayed, second abdominal image after the administration of the of [68Ga]Ga-NeoB was acquired at 120 min post injection. CONCLUSIONS: A fully GMP compliant kit preparation of [68Ga]Ga-NeoB enabling the routine production of the tracer under GMP conditions was established for clinical routine PET/CT imaging of patients with metastatic GIST and proved to adequately visualize tumor deposits in the abdomen expressing GRPR. Patients could benefit from additional information derived from [68Ga]Ga-NeoB diagnosis to assess the presence of GRPR in the tumor tissue and monitor antitumor treatment.

19.
Radiologe ; 61(Suppl 1): 49-53, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34013397

RESUMO

BACKGROUND: The fascia thoracolumbalis (FTL) is an important component for stabilization and motion control of the lumbar spine. It coordinates the traction forces of the autochthonous muscles of the back (AM) and connects them to the muscles of the abdominal wall, shoulder, and buttocks. OBJECTIVES: The aim of our study was to describe the assessment of the normal FTL and epimysium of the AM in MRI and to identify patterns associated with pathological changes in the lumbar spine. MATERIAL AND METHODS: A total of 33 patients were retrospectively evaluated: 15 patients had no pathology at the lumbar spine; six patients had previous hemilaminectomy, three had spondylodesis, two had ventrolisthesis, and seven had scoliosis. The thickness of the FTL and EM was measured, and the adhesion of both structures was assessed. RESULTS: The fascial thickness at the levels of the lumbar vertebral bodies LVB 3 was 1.8, of LVB 4 it was 2.0, of LVB 5 it was 2.1, and at the sacral vertebra SVB 1 it was 1.8 mm. Fascial adhesions together with thickening of the EM occurred at the level of LVB 4 in 36% of the cases independently of the underlying disorder. Only thickening of the EM was seen in 48% of cases at the level of SVB 1. By contrast, adhesion of the FTL without epimysial changes occurred in 36% of cases at the level of LVB 3. CONCLUSION: Thickening and adhesions at the EM and FTL occurred both postoperatively and in the case of scoliosis. Furthermore, lipomatous and muscular herniation could be detected in the FTL postoperatively. Epimysial and fascial alterations may be imaging manifestations of chronic myofascial back pain and should be included in radiological assessments.


Assuntos
Fáscia , Vértebras Lombares , Fáscia/diagnóstico por imagem , Humanos , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Músculo Esquelético , Estudos Retrospectivos
20.
ORL J Otorhinolaryngol Relat Spec ; 83(6): 439-448, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33784686

RESUMO

INTRODUCTION: Augmented reality can improve planning and execution of surgical procedures. Head-mounted devices such as the HoloLens® (Microsoft, Redmond, WA, USA) are particularly suitable to achieve these aims because they are controlled by hand gestures and enable contactless handling in a sterile environment. OBJECTIVES: So far, these systems have not yet found their way into the operating room for surgery of the parotid gland. This study explored the feasibility and accuracy of augmented reality-assisted parotid surgery. METHODS: 2D MRI holographic images were created, and 3D holograms were reconstructed from MRI DICOM files and made visible via the HoloLens. 2D MRI slices were scrolled through, 3D images were rotated, and 3D structures were shown and hidden only using hand gestures. The 3D model and the patient were aligned manually. RESULTS: The use of augmented reality with the HoloLens in parotic surgery was feasible. Gestures were recognized correctly. Mean accuracy of superimposition of the holographic model and patient's anatomy was 1.3 cm. Highly significant differences were seen in position error of registration between central and peripheral structures (p = 0.0059), with a least deviation of 10.9 mm (centrally) and highest deviation for the peripheral parts (19.6-mm deviation). CONCLUSION: This pilot study offers a first proof of concept of the clinical feasibility of the HoloLens for parotid tumor surgery. Workflow is not affected, but additional information is provided. The surgical performance could become safer through the navigation-like application of reality-fused 3D holograms, and it improves ergonomics without compromising sterility. Superimposition of the 3D holograms with the surgical field was possible, but further invention is necessary to improve the accuracy.


Assuntos
Realidade Aumentada , Neoplasias Parotídeas , Cirurgia Assistida por Computador , Estudos de Viabilidade , Humanos , Imageamento Tridimensional/métodos , Glândula Parótida/diagnóstico por imagem , Glândula Parótida/cirurgia , Neoplasias Parotídeas/diagnóstico por imagem , Neoplasias Parotídeas/cirurgia , Projetos Piloto , Estudos Prospectivos , Cirurgia Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA