Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Anal Chem ; 96(17): 6528-6533, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38626116

RESUMO

In the development of biotherapeutics, a thorough understanding of a molecule's product quality attributes (PQAs) and their effect on structure-function relationships and long-term stability is essential for ensuring the safety and efficacy of the product. First published in 2015, the multi-attribute method (MAM), based on LC-MS peptide mapping and automation principles, can be used to support biotherapeutic process and product development. The MAM provides simultaneous site-specific detection, identification, quantitation, and quality control monitoring of selected PQAs. In this article, a low-maintenance MAM-ready mass detector with a small footprint was evaluated for its ability to monitor PQAs on proteolytically digested proteins with high mass accuracy and precision. Optimized source parameters enable robust relative quantitation of attributes with high sensitivity and minimal in-source fragmentation. A combination of a built-in one-point mass calibration procedure prior to data acquisition and Scan-to-Scan on-the-fly mass correction allows monitoring of most peptides for at least 54 days with sub-1 ppm mass accuracies at high-resolution (180,000 at m/z 200). This enables the use of <3 ppm mass tolerances for peptide monitoring, supporting high method specificity and robustness. LC-MS based MAM data from this instrument compares well to data collected by earlier MAM systems and conventional HPLC profile-based drug substance release assays.


Assuntos
Espectrometria de Massas , Calibragem , Peptídeos/análise , Peptídeos/química , Cromatografia Líquida/métodos
2.
Crit Rev Anal Chem ; : 1-18, 2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37490277

RESUMO

The rapid growth of biotherapeutic industry, with more and more complex molecules entering the market, forces the need for advanced analytical platforms that can quickly and accurately identify and quantify product quality attributes. Mass spectrometry has the potential to provide more detailed information about the quality attributes of complex products, and MS methods are more sensitive than UV methods for detection of impurities. The multi-attribute method (MAM), a liquid chromatography-mass spectrometry based analytical approach is an emerging platform which supports biotherapeutic characterization and cGMP testing. The main advantage lies in the ability to monitor multiple quality attributes in a single assay, both at the peptide and the intact level, facilitating streamlined biopharmaceutical production, from research and development to the QC environment. This review highlights the current landscape of the MAM approach with special attention given to increased analytical throughput, general requirements for QC in terms of instrumentation and software, regulatory requirements, and industry acceptance of the MAM platform.

3.
Front Bioeng Biotechnol ; 9: 569045, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33898396

RESUMO

The biopharmaceutical market is dominated by monoclonal antibodies, the majority of which are produced in Chinese hamster ovary (CHO) cell lines. Intense cell engineering, in combination with optimization of various process parameters results in increasing product titers. To enable further improvements in manufacturing processes, detailed information about how certain parameters affect cellular mechanisms in the production cells, and thereby also the expressed drug substance, is required. Therefore, in this study the effects of commonly applied changes in bioprocessing parameters on an anti-IL8 IgG1 producing CHO DP-12 cell line were investigated on the level of host cell proteome expression combined with product quality assessment of the expressed IgG1 monoclonal antibody. Applying shifts in temperature, pH and dissolved oxygen concentration, respectively, resulted in altered productivity and product quality. Furthermore, analysis of the cells using two-dimensional liquid chromatography-mass spectrometry employing tandem mass tag based isotopic quantitation and synchronous precursor selection-MS3 detection revealed substantial changes in the protein expression profiles of CHO cells. Pathway analysis indicated that applied bioprocessing conditions resulted in differential activation of oxidative phosphorylation. Additionally, activation of ERK5 and TNFR1 signaling suggested an affected cell cycle. Moreover, in-depth product characterization by means of charge variant analysis, peptide mapping, as well as structural and functional analysis, revealed posttranslational and structural changes in the expressed drug substance. Taken together, the present study allows the conclusion that, in anti-IL8 IgG1 producing CHO DP-12 cells, an improved energy metabolism achieved by lowering the cell culture pH is favorable when aiming towards high antibody production rates while maintaining product quality.

4.
J Am Soc Mass Spectrom ; 32(8): 1998-2012, 2021 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-33513021

RESUMO

The multi-attribute method (MAM) is a liquid chromatography-mass spectrometry based method that is used to directly characterize and monitor many product quality attributes and impurities on biotherapeutics, most commonly at the peptide level. It utilizes high-resolution accurate mass spectral data which are analyzed in an automated fashion. MAM is a promising approach that is intended to replace or supplement several conventional assays with a single LC-MS analysis and can be implemented in a Current Good Manufacturing Practice environment. MAM provides accurate site-specific quantitation information on targeted attributes and the nontargeted new peak detection function allows to detect new peaks as impurities, modifications, or sequence variants when comparing to a reference sample. The high resolution MAM workflow was applied here for three independent case studies. First, to monitor the behavior of monoclonal antibody product quality attributes over the course of a 12-day cell culture experiment providing an insight into the behavior and dynamics of product attributes throughout the process. Second, the workflow was applied to test the purity and identity of a product through analysis of samples spiked with host cell proteins. Third, through the comparison of a drug product and a biosimilar with known sequence variants. The three case studies presented here, clearly demonstrate the robustness and accuracy of the MAM workflow that implies suitability for deployment in the regulated environment.


Assuntos
Anticorpos Monoclonais/química , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Animais , Anticorpos Monoclonais/análise , Técnicas de Cultura Celular por Lotes/métodos , Medicamentos Biossimilares/análise , Medicamentos Biossimilares/química , Células CHO , Catepsina L/análise , Catepsina L/química , Catepsina L/genética , Cricetulus , Contaminação de Medicamentos , Glicosilação , Imunoglobulina G/análise , Imunoglobulina G/genética , Lipase Lipoproteica/análise , Lipase Lipoproteica/química , Lipase Lipoproteica/genética , Lisina/química , Controle de Qualidade , Proteínas Recombinantes/análise , Proteínas Recombinantes/química , Proteínas Recombinantes/genética , Succinimidas/química , Tripsina/química , Fluxo de Trabalho
5.
Eur J Pharm Biopharm ; 158: 83-95, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33212184

RESUMO

The biopharmaceutical industry continues to develop mAb-based biotherapeutics in increasing numbers. Due to their complexity, there are several critical quality attributes (CQAs) that need to be measured and controlled to guarantee product safety and efficacy. Charge variant analysis is a widely used method to monitor changes in product quality during the manufacturing process of monoclonal antibodies (mAbs) and, together with a bottom-up peptide centred approach, acts as a key analytical platform to fulfil regulatory requirements. Native MS measures biomolecules under conditions that preserve most aspects of protein tertiary and quaternary structure, enabling direct characterization of large intact proteins such as mAbs. The resulting native mass spectrum of a mAb is characterized by a narrower charge-state envelope that simplifies the spectra and also condenses the ion signals into fewer peaks, increasing the signal-to-noise ratio. Algorithmic spectral deconvolution is needed for routine accurate and rapid molecular weight determination, and consequently, multiple deconvolution algorithms have evolved over the past decade. Here, we demonstrate the utility of the sliding window algorithm as a robust and powerful deconvolution tool for comprehensive characterisation of charge variant analysis data for mAbs. Optimum performance is evaluated by studying the impact of critical software parameters on detection, identification and relative quantitation of protein isoforms. By combining molecular mass and retention time information, it was possible to identify multiple modifications on adalimumab and trastuzumab, both IgG1 mAbs, including lysine truncation, deamidation and succinimide formation, along with the N-glycan distribution of each of the identified charge variants. Sliding window deconvolution also provides a key benefit of low abundant variant detection in a single analysis and the ability to detect co-eluting components with different relative abundances. The studied mAbs demonstrate the algoritms applicability for efficient data processing of both simple and complex mAbs analysed using pH gradient cation exchange chromatography coupled to native mass spectrometry.


Assuntos
Adalimumab/análise , Controle de Qualidade , Trastuzumab/análise , Adalimumab/química , Resinas de Troca de Cátion/química , Cromatografia por Troca Iônica/métodos , Cromatografia por Troca Iônica/normas , Concentração de Íons de Hidrogênio , Espectrometria de Massas/métodos , Espectrometria de Massas/normas , Software , Trastuzumab/química
6.
J Proteome Res ; 18(10): 3689-3702, 2019 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-31478673

RESUMO

Posttranslational modifications of proteins play fundamental roles in protein function in health and disease. More than 600 different types of posttranslational modifications are known, many of them being of extremely low abundance, causing subtle changes in physicochemical properties and posing an extreme challenge to analytical methods required for their characterization. Here, we report the development of a novel pH gradient-based anion-exchange chromatography method, which can be directly interfaced to Orbitrap-based mass spectrometry for the comprehensive characterization of proteoforms at the intact protein level under native conditions. The analysis of four different proteins demonstrates outstanding chromatographic selectivity, while the mass spectra obtained are of excellent quality enabling the identification of proteoforms, including near isobaric variants, spanning 4 orders of magnitude in abundance. An in-depth analysis of ovalbumin from chicken egg white yields the identification and relative quantification of more than 150 different proteoforms, including fragmented and dimeric forms. More than 20 different ovalbumin charge variants together with their glycoform distributions are identified and quantified, many of which have not been reported previously.


Assuntos
Ovalbumina/análise , Proteínas/análise , Proteômica/métodos , Animais , Ânions , Galinhas , Cromatografia por Troca Iônica , Humanos , Concentração de Íons de Hidrogênio , Espectrometria de Massas , Processamento de Proteína Pós-Traducional
7.
MAbs ; 11(1): 116-128, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30296204

RESUMO

Charge variant analysis is a widely used tool to monitor changes in product quality during the manufacturing process of monoclonal antibodies (mAbs). Although it is a powerful technique for revealing mAb heterogeneity, an unexpected outcome, for example the appearance of previously undetected isoforms, requires further, time-consuming analysis. The process of identifying these unknowns can also result in unwanted changes to the molecule that are not attributable to the manufacturing process. To overcome this, we recently reported a method combining highly selective cation exchange chromatography-based charge variant analysis with on-line mass spectrometric (MS) detection. We further explored and adapted the chromatographic buffer system to expand the application range. Moreover, we observed no salt adducts on the native protein, also supported by the optimal choice of MS parameters, resulting in increased data quality and mass accuracy. Here, we demonstrate the utility of this improved method by performing an in-depth analysis of adalimumab before and after forced degradation. By combining molecular mass and retention time information, we were able to identify multiple modifications on adalimumab, including lysine truncation, glycation, deamidation, succinimide formation, isomerisation, N-terminal aspartic acid loss or C-terminal proline amidation and fragmentation along with the N-glycan distribution of each of these identified proteoforms. Host cell protein (HCP) analysis was performed using liquid chromatography-mass spectrometry that verified the presence of the protease Cathepsin L. Based on the presence of trace HCPs with catalytic activity, it can be questioned if fragmentation is solely driven by spontaneous hydrolysis or possibly also by enzymatic degradation.


Assuntos
Adalimumab/química , Espectrometria de Massas em Tandem/métodos
8.
Nat Commun ; 9(1): 1713, 2018 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-29712889

RESUMO

Robust manufacturing processes resulting in consistent glycosylation are critical for the efficacy and safety of biopharmaceuticals. Information on glycosylation can be obtained by conventional bottom-up methods but is often limited to the glycan or glycopeptide level. Here, we apply high-resolution native mass spectrometry (MS) for the characterization of the therapeutic fusion protein Etanercept to unravel glycoform heterogeneity in conditions of hitherto unmatched mass spectral complexity. Higher spatial resolution at lower charge states, an inherent characteristic of native MS, represents a key component for the successful revelation of glycan heterogeneity. Combined with enzymatic dissection using a set of proteases and glycosidases, assignment of specific glycoforms is achieved by transferring information from subunit to whole protein level. The application of native mass spectrometric analysis of intact Etanercept as a fingerprinting tool for the assessment of batch-to-batch variability is exemplified and may be extended to demonstrate comparability after changes in the biologic manufacturing process.

9.
Anal Chem ; 90(7): 4669-4676, 2018 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-29494133

RESUMO

Charge variant analysis (CVA) of monoclonal antibodies (mAbs) using cation exchange chromatography is routinely used as a fingerprint of the distribution of posttranslational modifications present on the molecule. Traditional salt or pH based eluents are not suited for direct coupling to mass spectrometry due to nonvolatility or high ionic strength. This makes further analysis complicated when an alteration in the charge variant profile or the emergence of an additional peak is encountered. Here, the use of pH gradient elution using volatile, low ionic strength buffers is reported with direct coupling to high-resolution Orbitrap mass spectrometry. The development of a universal method based on pH elution was explored using a number of mAb drug products. Optimized methods facilitated the separation and identification of charge variants including individual glycoforms of the mAbs investigated using the same buffer system but with tailored gradient slopes. The developed method represents an exciting advance for the characterization of biopharmaceuticals as intact entities through the combination of native charge variant separations with high-resolution native mass spectrometry.

10.
J Proteomics ; 175: 42-55, 2018 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-28385662

RESUMO

Top-down mass spectrometry (MS) strategies allow in-depth characterization of proteins by fragmentation of the entire molecule(s) inside a mass spectrometer without requiring prior proteolytic digestion. Importantly, the fragmentation techniques on commercially available mass spectrometers have become more versatile over the past decade, with different characteristics in regards to the type and wealth of fragment ions that can be obtained while preserving labile protein post-translational modifications. Due to these and other improvements, top-down MS has become of broader interest and has started to be applied in more disciplines, such as the quality control of recombinant proteins, analysis and characterization of biopharmaceuticals, and clinical biochemistry to probe protein forms as potential disease biomarkers. This article provides a technical overview and guidance for data acquisition strategies on the Orbitrap platform for single proteins and low complexity protein mixtures. A protein standard mixture composed of six recombinant proteins is also introduced and analysis strategies are discussed in detail. BIOLOGICAL SIGNIFICANCE: The article provides a detailed overview and guidance on how to choose from the variety of available methods for protein characterization by top-down analysis on the Orbitrap platform. Technical details are provided explaining important observations and phenomena when working with intact proteins and data from a number of different samples should serve to provide a solid understanding on how experiments were and should be setup and to set the right expectations on the outcome of these types of experiments. Additionally, a new intact protein standard sample is introduced that will help as a QC sample to check the instrument's hardware and method setup conditions as a requirement for obtaining high quality data from biologically relevant samples.


Assuntos
Fragmentos de Peptídeos/análise , Proteômica/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Coleta de Dados/normas , Processamento de Proteína Pós-Traducional , Proteômica/normas , Controle de Qualidade , Proteínas Recombinantes , Espectrometria de Massas por Ionização por Electrospray/normas
11.
Anal Chem ; 89(20): 10873-10882, 2017 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-28922593

RESUMO

Bispecific antibodies (bsAbs) are one of the most versatile and promising pharmaceutical innovations for countering heterogeneous and refractory disease by virtue of their ability to bind two distinct antigens. One critical quality attribute of bsAb formation requiring investigation is the potential randomization of cognate heavy (H) chain/light (L) chain pairing, which could occur to a varying extent dependent on bsAb format and the production platform. To assess the content of such HL-chain swapped reaction products with high sensitivity, we developed cysteine-stable isotope labeling using amino acids in cell culture (SILAC), a method that facilitates the detailed characterization of disulfide-bridged peptides by mass spectrometry. For this analysis, an antibody was metabolically labeled with 13C3,15N-cysteine and incorporated into a comprehensive panel of distinct bispecific molecules by controlled Fab-arm exchange (DuoBody technology). This technology is a postproduction method for the generation of bispecific therapeutic IgGs of which several have progressed into the clinic. Herein, two parental antibodies, each containing a single heavy chain domain mutation, are mixed and subjected to controlled reducing conditions during which they exchange heavy-light (HL) chain pairs to form bsAbs. Subsequently, reductant is removed and all disulfide bridges are reoxidized to reform covalent inter- and intrachain bonds. We conducted a multilevel (Top-Middle-Bottom-Up) approach focusing on the characterization of both "left-arm" and "right-arm" HL interchain disulfide peptides and observed that native HL pairing was preserved in the whole panel of bsAbs produced by controlled Fab-arm exchange.


Assuntos
Anticorpos Biespecíficos/química , Cisteína/química , Dissulfetos/análise , Imunoglobulina G/química , Espectrometria de Massas em Tandem , Anticorpos Biespecíficos/metabolismo , Antígenos CD20/imunologia , Isótopos de Carbono/química , Cromatografia Líquida de Alta Pressão , Receptores ErbB/imunologia , Humanos , Fragmentos Fab das Imunoglobulinas/química , Fragmentos Fab das Imunoglobulinas/genética , Fragmentos Fab das Imunoglobulinas/metabolismo , Imunoglobulina G/metabolismo , Marcação por Isótopo , Isótopos de Nitrogênio/química
12.
Methods Mol Biol ; 1156: 465-87, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24792008

RESUMO

Top-down proteomics has become a popular approach for the analysis of intact proteins. The term "top down" has been coined for the analysis of proteins not involving any enzymatic or chemical cleavage but rather the ionization of the protein as a sound molecule and mass analysis of intact species and fragment ions thereof produced upon dissociation inside a mass spectrometer. One or several charge states of the protein are mass-isolated and subjected to dissociation (MS/MS) in the gas phase. The obtained fragment masses, predominantly from cleavages of the protein along its amino acid backbone, are directly related to the intact protein. Using bioinformatics tools the fragment masses are matched against a known protein sequence or can alternatively be used for partial or full de novo sequencing, depending on the size of the protein and the number of fragment ions obtained. Moreover, this approach provides global information about modification states of proteins including the number and types of isoforms and their stoichiometry and allows for the precise localization of modifications within the amino acid sequence. Top-down analysis of a single, purified protein can be performed by matrix-assisted laser desorption ionization or electrospray ionization upon direct infusion without online chromatographic separation, whereas top-down analysis of complex protein mixtures makes pre-fractionation combined with an efficient front-end chromatographic separation coupled online to the mass spectrometer inevitable.


Assuntos
Proteômica , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida , Biologia Computacional , Eletroforese em Gel de Poliacrilamida , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
13.
Anal Chem ; 86(1): 826-34, 2014 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-24308604

RESUMO

The characterization of proteins modified with poly(ethylene glycol) (PEG), such as recombinant human granulocyte-colony stimulating factor (PEGylated rhG-CSF or pegfilgrastim), by electrospray ionization-mass spectrometry (ESI-MS) constitutes a challenge due to the overlapping protein charge state pattern and PEG polydispersity. In order to minimize spectral overlaps, charge reduction by means of the addition of amine was applied. Method development for direct-infusion measurements, carried out on an ESI-time-of-flight (ESI-TOF) instrument, demonstrated the potential of triethylamine (TEA) for shifting the charge state pattern toward lower-charged species and of formic acid (FA) for causing higher charging. After successful method transfer to the LTQ Orbitrap XL instrument, isotopically resolved mass spectra could be acquired. With a median mass accuracy of 1.26 ppm, a number-average monoisotopic molecular mass of 40074.64 Da was determined for pegfilgrastim. The direct comparison of three Orbitrap mass spectrometers, namely the LTQ Orbitrap XL, the Exactive, and the Q Exactive, demonstrated that online interfacing to high performance liquid chromatography (HPLC) was only feasible with the Q Exactive, which offers adequate spectral quality on a time scale compatible with chromatographic separation (i.e., 0.2 min acquisition time per chromatographic peak). Finally, the applicability of both direct-infusion Orbitrap MS and HPLC interfaced to Orbitrap MS was demonstrated for the detection of methionine oxidation in pegfilgrastim. Singly, doubly, and triply oxidized species were readily resolved in the chromatogram, while their oxidation status was easily determined from the mass shifts observed in the deconvoluted mass spectra.


Assuntos
Fatores Estimuladores de Colônias/análise , Polietilenoglicóis/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Cromatografia Líquida de Alta Pressão/métodos , Fatores Estimuladores de Colônias/química , Humanos , Espectrometria de Massas/métodos , Polietilenoglicóis/química
14.
Eukaryot Cell ; 5(3): 457-68, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16524901

RESUMO

The unicellular flagellated green alga Chlamydomonas reinhardtii has emerged as a model organism for the study of a variety of cellular processes. Posttranslational control via protein phosphorylation plays a key role in signal transduction, regulation of gene expression, and control of metabolism. Thus, analysis of the phosphoproteome of C. reinhardtii can significantly enhance our understanding of various regulatory pathways. In this study, we have grown C. reinhardtii cultures in the presence of an inhibitor of Ser/Thr phosphatases to increase the phosphoprotein pool. Phosphopeptides from these cells were enriched by immobilized metal-ion affinity chromatography and analyzed by nano-liquid chromatography-electrospray ionization-mass spectrometry (MS) with MS-MS as well as neutral-loss-triggered MS-MS-MS spectra. In this way, we were able to identify 360 phosphopeptides from 328 different phosphoproteins of C. reinhardtii, thus providing new insights into a variety of cellular processes, including metabolic and signaling pathways. Comparative analysis of the phosphoproteome also yielded new functional information on proteins controlled by redox regulation (thioredoxin target proteins) and proteins of the chloroplast 70S ribosome, the centriole, and especially the flagella, for which 32 phosphoproteins were identified. The high yield of phosphoproteins of the latter correlates well with the presence of several flagellar kinases and indicates that phosphorylation/dephosphorylation represents one of the key regulatory mechanisms of eukaryotic cilia. Our data also provide new insights into certain cilium-related mammalian diseases.


Assuntos
Chlamydomonas reinhardtii/química , Chlamydomonas reinhardtii/metabolismo , Fosfoproteínas/análise , Proteoma/análise , Animais , Chlamydomonas reinhardtii/genética , Chlamydomonas reinhardtii/crescimento & desenvolvimento , Cromatografia de Afinidade , Espectrometria de Massas , Fosfoproteínas/química , Fosfoproteínas/genética , Fosfoproteínas/isolamento & purificação , Fosforilação , Transdução de Sinais , Espectrometria de Massas por Ionização por Electrospray
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA