Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 12(5): 484-493, 2019 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-30846089

RESUMO

OBJECTIVES: This study evaluated the 12-month safety and effectiveness of a paclitaxel drug-coated balloon for treatment of intermittent claudication or rest pain in subjects with femoropopliteal chronic total occlusions (CTO). BACKGROUND: CTOs are difficult to treat, and the optimal intervention remains to be determined. METHODS: The IN.PACT Global Study is an international single-arm study that enrolled 1,535 patients with symptomatic femoropopliteal artery disease. The study contains prospectively defined cohorts with prospectively planned imaging analyses, including a CTO (≥5 cm) cohort in which subjects underwent duplex ultrasonography analyzed by an independent core laboratory. The primary safety endpoint was a composite of freedom from device- and procedure-related mortality through 30 days, and freedom from major target limb amputation and target vessel revascularization through 12 months. An independent Clinical Events Committee adjudicated all adverse events. The primary effectiveness endpoint was primary patency at 12 months, defined as freedom from clinically driven target lesion revascularization and freedom from restenosis. RESULTS: The CTO imaging cohort had 126 subjects with 127 lesions (mean lesion length 22.83 ± 9.76 cm). Primary patency by Kaplan-Meier estimate was 85.3% through 12 months. Provisional stenting was performed in 46.8% of lesions. The primary safety composite endpoint was achieved by 88.7% of subjects. There were no device- or procedure-related deaths through 30 days or major target limb amputations through 12 months. CONCLUSIONS: The paclitaxel drug-coated balloon was safe and highly effective at 12 months after treatment of subjects with CTO ≥5 cm in the femoropopliteal arteries. (IN.PACT Global Clinical Study; NCT01609296).


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Artéria Femoral , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Idoso , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Doença Crônica , Constrição Patológica , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Intervalo Livre de Progressão , Estudos Prospectivos , Recidiva , Medição de Risco , Fatores de Risco , Fatores de Tempo , Grau de Desobstrução Vascular
2.
Circ Cardiovasc Interv ; 12(1): e007730, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30630355
3.
Circ Cardiovasc Interv ; 11(10): e005654, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30354636

RESUMO

Background The IN.PACT Global Study was an international prospective single-arm clinical trial to evaluate the safety and effectiveness of a drug-coated balloon in the treatment of atherosclerotic disease of the superficial femoral and/or popliteal arteries (P1-P3) in subjects with intermittent claudication and/or rest pain. Prespecified subjects were selected for core-laboratory-adjudicated duplex ultrasound imaging, including a subcohort with long lesions (≥15 cm). Methods and Results Subjects were followed for 12 months. The primary safety end point was a composite of freedom from device- and procedure-related mortality through 30 days and freedom from major target limb amputation and clinically-driven target vessel revascularization through 12 months. An independent Clinical Events Committee adjudicated all adverse events. The primary effectiveness end point was primary patency at 12 months (by duplex ultrasound). The long lesion imaging cohort had 157 subjects (164 lesions). Mean lesion length was 26.40±8.61 cm. Provisional stents were implanted in 39.4% (63/160) of lesions. Primary patency by Kaplan-Meier estimate was 91.1%, and freedom from clinically-driven target lesion revascularization was 94.2% at 12 months. The primary safety composite end point was achieved by 94.0% (126/134) of subjects. There were no device- or procedure-related deaths or major target limb amputations. Conclusions The IN.PACT Admiral drug-coated balloon was safe and highly effective at 12 months after treatment in a rigorous independently adjudicated analysis of real-world subjects with lesions ≥15 cm in the superficial femoral and/or popliteal arteries (P1-P3). CLINICAL TRIAL REGISTRATION URL: https://www.clinicaltrials.gov . Unique identifier: NCT01609296.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Artéria Femoral , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla
4.
JACC Cardiovasc Interv ; 10(20): 2113-2123, 2017 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-29050631

RESUMO

OBJECTIVES: This study sought to evaluate the safety and effectiveness of a paclitaxel-coated drug-coated balloon (DCB) for the treatment of patients with de novo in-stent restenosis (ISR). BACKGROUND: Treatment of patients with ISR remains a challenge. Current strategies are plagued by high rates of recurrent restenosis and need for reintervention. The best intervention for ISR remains to be elucidated. METHODS: The IN.PACT Global study is an independently adjudicated multicenter, prospective, single-arm study that enrolled 1,535 subjects with symptomatic atherosclerotic disease of the superficial femoral and/or popliteal arteries, including de novo ISR lesions. Patients enrolled in the pre-specified ISR imaging cohort were evaluated for vessel patency and reintervention within the 12-month follow-up period. RESULTS: A total of 131 subjects with 149 ISR lesions were included for analysis. The mean age of the cohort was 67.8 years. Mean lesion length was 17.17 ± 10.47 cm, including 34.0% total occlusions and 59.1% calcified lesions. The 12-month Kaplan-Meier estimate of primary patency was 88.7%. The rate of clinically driven target lesion revascularization (CD TLR) at 12 months was 7.3%. The primary safety outcome, a composite of freedom from device- and procedure-related mortality through 30 days and freedom from major target limb amputation and CD TLR within 12 months, was 92.7%. There were no major target limb amputations, no deaths, and a low (0.8%) thrombosis rate. CONCLUSIONS: Results from the ISR imaging cohort demonstrate high patency and a low rate of CD TLR at 12 months. These data confirm the safety and effectiveness of the IN.PACT Admiral DCB (Medtronic, Dublin, Ireland) in complex femoropopliteal lesions, including this challenging subset.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Procedimentos Endovasculares/instrumentação , Artéria Femoral , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Stents , Dispositivos de Acesso Vascular , Idoso , Amputação Cirúrgica , Angiografia , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Recidiva , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA