Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Phys Rev E ; 102(4-1): 043212, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33212701

RESUMO

In this work, we present results from experiments capable of producing and measuring the propagation of multiple successive, copropagating shocks across an unstable planar interface, where the shocks are independently driven and separately controllable, enabling the study of this important phenomenon. Copropagating shocks play a significant role in a wide range of systems involving stratified media subject to a shock, and exhibit different physical characteristics compared to counterpropagating shocks. Existing techniques, however, preclude copropagating shocks, so experiments to date have been limited to the study of counterpropagating shocks. We address this previous limitation and open a physical parameter space for study using a new hohlraum platform on the National Ignition Facility. Initial experimental results are presented together with comparisons from numerical simulations.

2.
Phys Rev Lett ; 124(15): 159901, 2020 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-32357038

RESUMO

This corrects the article DOI: 10.1103/PhysRevLett.120.025002.

3.
Phys Rev Lett ; 124(18): 185003, 2020 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-32441981

RESUMO

Rayleigh-Taylor instability growth is shown to be hydrodynamically scale invariant in convergent cylindrical implosions for targets that varied in radial dimension and implosion timescale by a factor of 3. The targets were driven directly by laser irradiation providing a short impulse, and instability growth at an embedded aluminum interface occurs as it converges radially inward by a factor of 2.25 and decelerates on a central foam core. Late-time growth factors of 14 are observed for a single-mode m=20 azimuthal perturbation at both scales, despite the differences in laser drive conditions between the experimental facilities, consistent with predictions from radiation-hydrodynamics simulations. This platform enables detailed investigations into the limits of hydrodynamic scaling in high-energy-density systems.

4.
Nat Commun ; 11(1): 544, 2020 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-31992703

RESUMO

The injection and mixing of contaminant mass into the fuel in inertial confinement fusion (ICF) implosions is a primary factor preventing ignition. ICF experiments have recently achieved an alpha-heating regime, in which fusion self-heating is the dominant source of yield, by reducing the susceptibility of implosions to instabilities that inject this mass. We report the results of unique separated reactants implosion experiments studying pre-mixed contaminant as well as detailed high-resolution three-dimensional simulations that are in good agreement with experiments. At conditions relevant to mixing regions in high-yield implosions, we observe persistent chunks of contaminant that do not achieve thermal equilibrium with the fuel throughout the burn phase. The assumption of thermal equilibrium is made in nearly all computational ICF modeling and methods used to infer levels of contaminant from experiments. We estimate that these methods may underestimate the amount of contaminant by a factor of two or more.

5.
J Ovarian Res ; 12(1): 8, 2019 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-30684970

RESUMO

BACKGROUND: Ovarian hyperstimulation syndrome remains a serious complication during in vitro fertilization cycles if high dose human chorionic gonadotropin (hCG) is used to trigger ovulation in high responder patients. Though much of this risk is mitigated with trigger using gonadotropin releasing-hormone (GnRH) agonist alone, it may result in lower birth rates. GnRH-agonist trigger and adjuvant low dose hCG has been proposed to improve birth rates, but timing of this hCG support to corpus luteum function has never been fully described. In this randomized, prospective trial, we explore differences in live birth rates and incidence of ovarian hyperstimulation syndrome (OHSS) in high-responder patients undergoing in vitro fertilization (IVF) receiving low dose hCG at the time of GnRH-agonist (dual trigger) or hCG adjuvant at the time of oocyte retrieval. Does the timing of hCG support make a difference? RESULTS: Thirty-four subjects high-responder patients were randomized to receive low-dose hCG at the time of GnRH-agonist trigger (Group 1) and 37 received low-dose hCG at the time of oocyte retrieval (Group 2). There were no differences in the baseline characteristics and outcome of ovarian stimulation between the two groups. There were no differences in the live birth rates between Group 1 and Group 2 by intention-to-treat (14/34, 41.2% versus 21/37, 56.8%, p = 0.19) or per-protocol (14/26, 53.8% versus 19/31, 61.3%, p = 0.57) analyses. There was a slightly higher incidence of OHSS in Group 2 compared to Group 1 although the difference was not statistically significant (3/31, 9.7% versus 1/26, 3.8%). All the cases of OHSS in Group 2 were moderate while the one case of OHSS in Group 1 was mild. CONCLUSIONS: For high responder patients receiving GnRH-agonist trigger, low dose hCG supplementation allowed high pregnancy rates after fresh embryo transfer, regardless of whether it was given at the time of trigger or at oocyte retrieval. Dual trigger may be preferable to reduce the risk of OHSS.


Assuntos
Gonadotropina Coriônica/administração & dosagem , Fertilização in vitro , Hormônio Liberador de Gonadotropina/agonistas , Indução da Ovulação/métodos , Taxa de Gravidez , Adulto , Método Duplo-Cego , Feminino , Humanos , Nascido Vivo , Síndrome de Hiperestimulação Ovariana/induzido quimicamente , Gravidez , Estudos Prospectivos , Risco
6.
Rev Sci Instrum ; 89(10): 10I127, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399819

RESUMO

The current construction of a new nuclear-imaging view at the National Ignition Facility will provide a third line of sight for hotspot and cold fuel imaging and the first dedicated line of sight for 4.4-MeV γ-ray imaging of the remaining carbon ablator. To minimize the effort required to hold and align apertures inside the vacuum chamber, the apertures for the two lines of sight will be contained in the same array. In this work, we discuss the system requirements for neutron and γ-ray imaging and the resulting aperture array design.

7.
Phys Rev Lett ; 120(2): 025002, 2018 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-29376698

RESUMO

This Letter presents a novel approach to study electron transport in warm dense matter. It also includes the first x-ray Thomson scattering (XRTS) measurement from low-density CH foams compressed by a strong laser-driven shock at the OMEGA laser facility. The XRTS measurement is combined with velocity interferometry (VISAR) and optical pyrometry (SOP) providing a robust measurement of thermodynamic conditions in the shock. Evidence of significant preheat contributing to elevated temperatures reaching 17.5-35 eV in shocked CH foam is measured by XRTS. These measurements are complemented by abnormally high shock velocities observed by VISAR and early emission seen by SOP. These results are compared to radiation hydrodynamics simulations that include first-principles treatment of nonlocal electron transport in warm dense matter with excellent agreement. Additional simulations confirm that the x-ray contribution to this preheat is negligible.

8.
Phys Rev E ; 95(2-1): 023202, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28297959

RESUMO

We report an experimental and computational study investigating the effects of laser preheat on the hydrodynamic behavior of a material layer. In particular, we find that perturbation of the surface of the layer results in a complex interaction, in which the bulk of the layer develops density, pressure, and temperature structure and in which the surface experiences instability-like behavior, including mode coupling. A uniform one-temperature preheat model is used to reproduce the experimentally observed behavior, and we find that this model can be used to capture the evolution of the layer, while also providing evidence of complexities in the preheat behavior. This result has important consequences for inertially confined fusion plasmas, which can be difficult to diagnose in detail, as well as for laser hydrodynamics experiments, which generally depend on assumptions about initial conditions in order to interpret their results.

9.
Phys Rev Lett ; 117(22): 225001, 2016 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-27925731

RESUMO

Using a large volume high-energy-density fluid shear experiment (8.5 cm^{3}) at the National Ignition Facility, we have demonstrated for the first time the ability to significantly alter the evolution of a supersonic sheared mixing layer by controlling the initial conditions of that layer. By altering the initial surface roughness of the tracer foil, we demonstrate the ability to transition the shear mixing layer from a highly ordered system of coherent structures to a randomly ordered system with a faster growing mix layer, indicative of strong mixing in the layer at a temperature of several tens of electron volts and at near solid density. Simulations using a turbulent-mix model show good agreement with the experimental results and poor agreement without turbulent mix.

10.
Rev Sci Instrum ; 87(11): 11D821, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910447

RESUMO

The installation of a neutron imaging diagnostic with a polar view at the National Ignition Facility (NIF) required design of a new aperture, an extended pinhole array (PHA). This PHA is different from the pinhole array for the existing equatorial system due to significant changes in the alignment and recording systems. The complex set of component requirements, as well as significant space constraints in its intended location, makes the design of this aperture challenging. In addition, lessons learned from development of prior apertures mandate careful aperture metrology prior to first use. This paper discusses the PHA requirements, constraints, and the final design. The PHA design is complex due to size constraints, machining precision, assembly tolerances, and design requirements. When fully assembled, the aperture is a 15 mm × 15 mm × 200 mm tungsten and gold assembly. The PHA body is made from 2 layers of tungsten and 11 layers of gold. The gold layers include 4 layers containing penumbral openings, 4 layers containing pinholes and 3 spacer layers. In total, there are 64 individual, triangular pinholes with a field of view (FOV) of 200 µm and 6 penumbral apertures. Each pinhole is pointed to a slightly different location in the target plane, making the effective FOV of this PHA a 700 µm square in the target plane. The large FOV of the PHA reduces the alignment requirements both for the PHA and the target, allowing for alignment with a laser tracking system at NIF.

11.
Rev Sci Instrum ; 87(11): 11E313, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910456

RESUMO

A dual-channel streaked soft x-ray imager has been designed and used on high energy-density physics experiments at the National Ignition Facility. This streaked imager creates two images of the same x-ray source using two slit apertures and a single shallow angle reflection from a nickel mirror. Thin filters are used to create narrow band pass images at 510 eV and 360 eV. When measuring a Planckian spectrum, the brightness ratio of the two images can be translated into a color-temperature, provided that the spectral sensitivity of the two images is well known. To reduce uncertainty and remove spectral features in the streak camera photocathode from this photon energy range, a thin 100 nm CsI on 50 nm Al streak camera photocathode was implemented. Provided that the spectral shape is well-known, then uncertainties on the spectral sensitivity limits the accuracy of the temperature measurement to approximately 4.5% at 100 eV.

12.
Rev Sci Instrum ; 87(11): 11D703, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910487

RESUMO

X-ray and neutrons are commonly used to image inertial confinement fusion implosions, providing key diagnostic information on the fuel assembly of burning deuterium-tritium (DT) fuel. The x-ray and neutron data provided are complementary as the production of neutrons and x-rays occurs from different physical processes, but typically these two images are collected from different views with no opportunity for co-registration of the two images. Neutrons are produced where the DT fusion fuel is burning; X-rays are produced in regions corresponding to high temperatures. Processes such as mix of ablator material into the hotspot can result in increased x-ray production and decreased neutron production but can only be confidently observed if the two images are collected along the same line of sight and co-registered. To allow direct comparison of x-ray and neutron data, a combined neutron x-ray imaging system has been tested at Omega and installed at the National Ignition Facility to collect an x-ray image along the currently installed neutron imaging line of sight. This system is described, and initial results are presented along with prospects for definitive coregistration of the images.

13.
Rev Sci Instrum ; 87(5): 055110, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27250473

RESUMO

A new streaked soft x-ray imager has been designed for use on high energy-density (HED) physics experiments at the National Ignition Facility based at the Lawrence Livermore National Laboratory. This streaked imager uses a slit aperture, single shallow angle reflection from a nickel mirror, and soft x-ray filtering to, when coupled to one of the NIF's x-ray streak cameras, record a 4× magnification, one-dimensional image of an x-ray source with a spatial resolution of less than 90 µm. The energy band pass produced depends upon the filter material used; for the first qualification shots, vanadium and silver-on-titanium filters were used to gate on photon energy ranges of approximately 300-510 eV and 200-400 eV, respectively. A two-channel version of the snout is available for x-ray sources up to 1 mm and a single-channel is available for larger sources up to 3 mm. Both the one and two-channel variants have been qualified on quartz wire and HED physics target shots.

14.
Rev Sci Instrum ; 86(4): 043503, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25933858

RESUMO

Neutron and x-ray imaging provide critical information about the geometry and hydrodynamics of inertial confinement fusion implosions. However, existing diagnostics at Omega and the National Ignition Facility (NIF) cannot produce images in both neutrons and x-rays along the same line of sight. This leads to difficulty comparing these images, which capture different parts of the plasma geometry, for the asymmetric implosions seen in present experiments. Further, even when opposing port neutron and x-ray images are available, they use different detectors and cannot provide positive information about the relative positions of the neutron and x-ray sources. A technique has been demonstrated on implosions at Omega that can capture x-ray images along the same line of sight as the neutron images. The technique is described, and data from a set of experiments are presented, along with a discussion of techniques for coregistration of the various images. It is concluded that the technique is viable and could provide valuable information if implemented on NIF in the near future.

15.
Artigo em Inglês | MEDLINE | ID: mdl-25314547

RESUMO

We present recent results of equation-of-state (EOS) measurements of shocked silica (SiO_{2}) aerogel foam at the OMEGA laser facility. Silica aerogel is an important low-density pressure standard used in many high energy density experiments, including the novel technique of shock and release. Due to its many applications, it has been a heavily studied material and has a well-known Hugoniot curve. This work then complements the velocity and pressure measurements with additional temperature data providing the full EOS information within the warm dense matter regime for the temperature interval of 1-15 eV and shock velocities between 10 and 40 km/s corresponding to shock pressures of 0.3-2 Mbar. The experimental results were compared with hydrodynamic simulations and EOS models. We found that the measured temperature was systematically lower than suggested by theoretical calculations. Simulations provide a possible explanation that the emission measured by optical pyrometry comes from a radiative precursor rather than from the shock front, which could have important implications for such measurements.


Assuntos
Teste de Materiais , Pressão , Dióxido de Silício/química , Temperatura , Géis , Interferometria , Lasers
16.
Clin Nephrol ; 73(3): 190-6, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20178717

RESUMO

BACKGROUND: In 2005, the Infectious Disease Society of America published a guideline recommending that all patients with human immunodeficiency virus (HIV) be screened for kidney disease. We initiated a screening program for kidney disease in a dedicated HIV clinic that follows 1,631 patients. METHODS: The screening consisted of a serum creatinine, an estimated glomerular filtration rate (eGFR) as defined by the abbreviated Modification of Diet in Renal Disease equation, and a standard urinalysis for proteinuria. Subjects were identified as having a positive screen if they had 1+ proteinuria or greater on a standard urinalysis or an eGFR of less than 60 ml/min/ 1.73 m2. After 1 year of screening, a retrospective chart review was conducted to determine the efficacy of screening. Bivariate associations were assessed for each outcome. A multiple logistic regression analysis was conducted first with main effects models and then for all variables and interactions. RESULTS: 941 subjects that did not have previously documented chronic kidney disease were screened and 96 (10.2%) met the definition of CKD. 9% of subjects had proteinuria and 2.4% had a qualifying eGFR. In multivariate analysis diabetes, hypertension, and low CD4 count (< 200 cells per mm3), low viral load (< 400 copies/ml) displayed strong associations with proteinuria. In the case of reduced eGFR, diabetes and age retained strong associations while the association with hypertension had borderline significance. CONCLUSION: This study emphasizes the potential of similar screening programs to identify early or mild CKD in an ambulatory population of patients with HIV.


Assuntos
Infecções por HIV/complicações , Programas de Rastreamento/métodos , Ambulatório Hospitalar , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Adulto , Albuminúria/diagnóstico , Albuminúria/etiologia , Albuminúria/urina , Contagem de Linfócito CD4 , Diagnóstico Precoce , Feminino , Seguimentos , Taxa de Filtração Glomerular , HIV/imunologia , Infecções por HIV/epidemiologia , Infecções por HIV/virologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prevalência , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Estudos Retrospectivos , Estados Unidos/epidemiologia , Carga Viral
17.
Clin Nephrol ; 73(3): 229-37, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20178723

RESUMO

BACKGROUND: Predicting bleeding after percutaneous kidney biopsy (PKB) is difficult. The value of Platelet Function Analyzer-100 (PFA-100) is not studied in this setting. METHODS: We undertook a prospective study of PFA-100 collagen/epinephrine (CEPI) and collagen/adenosine diphosphate (CADP) closure times among 56 participants (35 males and 21 females) undergoing PKB under real-time ultrasound (US) visualization at a tertiary teaching hospital. We collected data on age, sex, weight, height, blood pressure (BP), serum creatinine, random urine protein/creatinine ratio, electrolytes, PT/PTT, complete blood count, administration of desmopressin acetate and renal biopsy characteristics. Major outcomes were hematoma formation on US, packed red blood (PRBC) transfusions and hematuria. Data were analyzed with SPSS 16. RESULTS: PFA-CEPI was abnormal in 5 (8.93%) and PFA-CADP abnormal in 8 (14.3%) participants. Post-biopsy hematoma formation on US was detected in 11 (19%) participants, 5 (8.9%) had macroscopic hematuria and 4 (7%) required PRBC transfusion. Bleeding events did not correlate with body mass index, baseline BP or with each other. Hematuria and US-observed hematomas did not appear to be clinically relevant. PRBC transfusions showed a significant association with elevated baseline BUN (p = 0.031), creatinine (p = 0.011) and the number of biopsy passes (p = 0.008). PFA-100 CEPI and CADP did not associate with any of the bleeding complications after PKB (p = NS). CONCLUSIONS: Measuring PFA-100 is unlikely to add to the care of patients undergoing routine PKB. ClinicalTrials.gov NCT00334204.


Assuntos
Biópsia/efeitos adversos , Plaquetas/fisiologia , Hematoma/diagnóstico , Hematúria/diagnóstico , Nefropatias/patologia , Testes de Função Plaquetária/instrumentação , Adulto , Idoso , Biópsia/métodos , Desenho de Equipamento , Feminino , Seguimentos , Hematoma/sangue , Hematoma/etiologia , Hematúria/sangue , Hematúria/etiologia , Humanos , Nefropatias/sangue , Nefropatias/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Ultrassonografia , Adulto Jovem
18.
Health Phys ; 90(1): 16-30, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16340604

RESUMO

The Interagency Steering Committee on Radiation Standards (ISCORS) has recently completed a study of the occurrence within the United States of radioactive materials in sewage sludge and sewage incineration ash. One component of that effort was an examination of the possible transport of radioactivity from sludge into the local environment and the subsequent exposure of humans. A stochastic environmental pathway model was applied separately to seven hypothetical, generic sludge-release scenarios, leading to the creation of seven tables of Dose-to-Source Ratios (DSR), which can be used in translating from specific activity in sludge into dose to an individual. These DSR values were then combined with the results of an ISCORS survey of sludge and ash at more than 300 publicly owned treatment works, to explore the potential for radiation exposure of sludge workers and members of the public. This paper provides a brief overview of the pathway modeling methodology employed in the exposure and dose assessments and discusses technical aspects of the results obtained.


Assuntos
Doses de Radiação , Poluentes Radioativos/análise , Eliminação de Resíduos , Esgotos , Monitoramento Ambiental , Modelos Teóricos , Medição de Risco
19.
J Environ Qual ; 34(1): 64-74, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15647535

RESUMO

The Nuclear Regulatory Commission (NRC) announced the availability of three new documents concerning radioactive materials in sewage sludge and ash from publicly owned treatment works (POTW). One of the documents is a report presenting the results of a volunteer survey of sewage sludge and ash samples provided by 313 POTWs. The second document is a dose modeling document, using multiple exposure pathway modeling focused on a series of generic scenarios, to track possible exposure of POTW workers and members of the general public to radioactivity from the sewage sludge or ash. The third document is a guidance report providing recommendations on the management of radioactivity in sewage sludge and ash for POTW owners and operators. This paper explains how radioactive materials enter POTWs, provides criteria for evaluating levels of radioactive material in sludge and ash, and gives a summary of the results of the survey and dose modeling efforts.


Assuntos
Modelos Teóricos , Poluentes Radioativos/análise , Eliminação de Resíduos , Esgotos/química , Coleta de Dados , Monitoramento Ambiental , Medição de Risco , Estados Unidos
20.
Health Phys ; 81(5 Suppl): S78-84, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11669198

RESUMO

The MILDOS-AREA code was developed to estimate radiological doses and risks from uranium milling activities. The code has been used for demonstrating radiological compliance regarding the U.S. Nuclear Regulatory Commission's licensing requirements for uranium milling activities. The code was recently updated with an enhanced software package to address the following four areas: regulatory changes, in-situ leaching extraction technologies, software user interfaces, and software distribution technologies via the internet. Users can now specify in-situ leaching processes through a Windows object-based Geographic information System interface with incorporated updated regulation methodologies. The code and documentation are freely distributed through the Internet.


Assuntos
Proteção Radiológica/normas , Urânio , Humanos , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA