Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Diabetes Technol Ther ; 26(6): 383-393, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38277156

RESUMO

Background: To evaluate the long-term safety and effectiveness of the Omnipod® 5 Automated Insulin Delivery (AID) System in very young children with type 1 diabetes with up to 2 years of use. Methods: Following a 13-week single-arm, multicenter, pivotal trial that took place after 14 days of standard therapy data collection, participating children (2-5.9 years of age at study enrollment) were provided the option to continue use of the AID system in an extension phase. HbA1c was measured every 3 months, up to 15 months of total use, and continuous glucose monitor metrics were collected through the completion of the extension study (for up to 2 years). Results: Participants (N = 80) completed 18.2 [17.4, 23.4] (median [interquartile range]) total months of AID, inclusive of the 3-month pivotal trial. During the pivotal trial, HbA1c decreased from 7.4% ± 1.0% (57 ± 10.9 mmol/mol) to 6.9% ± 0.7% (52 ± 7.7 mmol/mol, P < 0.0001) and was maintained at 7.0% ± 0.7% (53 ± 7.7 mmol/mol) after 15 months total use (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 57.2% ± 15.3% during standard therapy to 68.1% ± 9.0% during the pivotal trial (P < 0.0001) and was maintained at 67.2% ± 9.3% during the extension phase (P < 0.0001 from standard therapy). Participants spent a median 97.1% of time in Automated Mode during the extension phase, with one episode of severe hypoglycemia and one episode of diabetic ketoacidosis. Conclusion: This evaluation of the Omnipod 5 AID System indicates that long-term use can safely maintain improvements in glycemic outcomes with up to 2 years of use in very young children with type 1 diabetes. Clinical Trials Registration Number: NCT04476472.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hemoglobinas Glicadas , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Pré-Escolar , Insulina/administração & dosagem , Insulina/uso terapêutico , Feminino , Masculino , Glicemia/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas/análise , Hipoglicemia/prevenção & controle , Resultado do Tratamento , Controle Glicêmico/métodos , Automonitorização da Glicemia
2.
Diabetes Res Clin Pract ; 208: 111114, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38278493

RESUMO

OBJECTIVE: Examine patient-reported outcomes (PROs) after the use of t:slim X2 insulin pump with Control-IQ technology (CIQ) in young children with type 1 diabetes. METHODS: Children with type 1 diabetes, ages 2 to < 6 years (n = 102), were randomly assigned 2:1 to either CIQ or standard care (SC) with pump or multiple daily injections (MDI) plus continuous glucose monitoring (CGM) for 13 weeks. Both groups were offered to use CIQ for an additional 13 weeks after the randomized control trial's (RCT) completion. Guardians completed PRO questionnaires at baseline, 13-, and 26-weeks examining hypoglycemia concerns, quality of life, parenting stress, and sleep. At 26 weeks, 28 families participated in user-experience interviews. Repeated measures analyses compared PRO scores between systems used. RESULT: Comparing CIQ vs SC, responses on all 5 PRO surveys favored the CIQ group, showing that CIQ was superior to SC at 26 weeks (p values < 0.05). User-experience interviews indicated significant benefits in optimized glycemic control overall and nighttime control (28 of 28 families endorsed). All but 2/28 families noted substantial reduction in management burden resulting in less mental burden and all but 4 stated that they wanted their children to continue using CIQ. CONCLUSIONS: Families utilizing CIQ experienced glycemic benefits coupled with substantial benefits in PROs, documented in surveys and interviews. Families utilizing CIQ had reduced hypoglycemia concerns and parenting stress, and improved quality of life and sleep. These findings demonstrate the benefit of CIQ in young children with type 1 diabetes that goes beyond documented glycemic benefit.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Pré-Escolar , Humanos , Glicemia , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Medidas de Resultados Relatados pelo Paciente
3.
N Engl J Med ; 388(11): 991-1001, 2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36920756

RESUMO

BACKGROUND: Closed-loop control systems of insulin delivery may improve glycemic outcomes in young children with type 1 diabetes. The efficacy and safety of initiating a closed-loop system virtually are unclear. METHODS: In this 13-week, multicenter trial, we randomly assigned, in a 2:1 ratio, children who were at least 2 years of age but younger than 6 years of age who had type 1 diabetes to receive treatment with a closed-loop system of insulin delivery or standard care that included either an insulin pump or multiple daily injections of insulin plus a continuous glucose monitor. The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. Secondary outcomes included the percentage of time that the glucose level was above 250 mg per deciliter or below 70 mg per deciliter, the mean glucose level, the glycated hemoglobin level, and safety outcomes. RESULTS: A total of 102 children underwent randomization (68 to the closed-loop group and 34 to the standard-care group); the glycated hemoglobin levels at baseline ranged from 5.2 to 11.5%. Initiation of the closed-loop system was virtual in 55 patients (81%). The mean (±SD) percentage of time that the glucose level was within the target range increased from 56.7±18.0% at baseline to 69.3±11.1% during the 13-week follow-up period in the closed-loop group and from 54.9±14.7% to 55.9±12.6% in the standard-care group (mean adjusted difference, 12.4 percentage points [equivalent to approximately 3 hours per day]; 95% confidence interval, 9.5 to 15.3; P<0.001). We observed similar treatment effects (favoring the closed-loop system) on the percentage of time that the glucose level was above 250 mg per deciliter, on the mean glucose level, and on the glycated hemoglobin level, with no significant between-group difference in the percentage of time that the glucose level was below 70 mg per deciliter. There were two cases of severe hypoglycemia in the closed-loop group and one case in the standard-care group. One case of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In this trial involving young children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with a closed-loop system than with standard care. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; PEDAP ClinicalTrials.gov number, NCT04796779.).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Criança , Pré-Escolar , Humanos , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos
6.
Diabetes Care ; 45(8): 1907-1910, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35678724

RESUMO

OBJECTIVE: Very young children with type 1 diabetes often struggle to achieve glycemic targets, putting them at risk for long-term complications and creating an immense management burden for caregivers. We conducted the first evaluation of the Omnipod 5 Automated Insulin Delivery System in this population. RESEARCH DESIGN AND METHODS: A total of 80 children aged 2.0-5.9 years used the investigational system in a single-arm study for 13 weeks following 14 days of baseline data collection with their usual therapy. RESULTS: There were no episodes of severe hypoglycemia or diabetic ketoacidosis. By study end, HbA1c decreased by 0.55% (6.0 mmol/mol) (P < 0.0001). Time with sensor glucose levels in target range 70-180 mg/dL increased by 10.9%, or 2.6 h/day (P < 0.0001), while time with levels <70 mg/dL declined by median 0.27% (P = 0.0204). CONCLUSIONS: Use of the automated insulin delivery system was safe, and participants experienced improved glycemic measures and reduced hypoglycemia during the study phase compared with baseline.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Glicemia , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/epidemiologia , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/epidemiologia , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico
7.
Diabetes Technol Ther ; 24(4): 285-288, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34962164

RESUMO

We assessed predictors of rising hemoglobin A1c (HbA1c) during long-term use of closed-loop control (CLC) in children aged 6-13 years with type 1 diabetes. Participants used a CLC system during a 16-week randomization phase followed by a 12-week extension phase. We compared an "Increased-HbA1c" group (n = 17, ≥0.5% rise in HbA1c between randomization and extension phases) to a "Maintained-Improvement" group (n = 18, had stable or improved HbA1c). The Increased-HbA1c group had higher pre-CLC HbA1c (8.42% ± 0.80 vs. 7.45% ± 0.93, P = 0.002). Contrary to a-priori hypotheses, there were no differences in Δ-height-for-age z-score, a surrogate for a pubertal growth spurt (+0.16 vs. -0.15, P = 0.113), or number of carbohydrate boluses per day, a surrogate for missed boluses (4.4 ± 2.2 vs. 5.2 ± 2.1, P = 0.263). Both groups maintained high rates in closed-loop. Thus, some children exhibit meaningful rise in HbA1c after initial CLC use, likely from multiple contributing factors, and may benefit from added encouragement during ongoing use.


Assuntos
Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Glicemia , Automonitorização da Glicemia , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico
8.
Diabetes Technol Ther ; 23(7): 475-481, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33689454

RESUMO

Background: Studies of closed-loop control (CLC) in patients with type 1 diabetes (T1D) consistently demonstrate improvements in glycemic control as measured by increased time-in-range (TIR) 70-180 mg/dL. However, clinical predictors of TIR in users of CLC systems are needed. Materials and Methods: We analyzed data from 100 children aged 6-13 years with T1D using the Tandem Control-IQ CLC system during a randomized trial or subsequent extension phase. Continuous glucose monitor data were collected at baseline and during 12-16 weeks of CLC use. Participants were stratified into quartiles of TIR on CLC to compare clinical characteristics. Results: TIR for those in the first, second, third, and fourth quartiles was 54%, 65%, 71%, and 78%, respectively. Lower baseline TIR was associated with lower TIR on CLC (r = 0.69, P < 0.001). However, lower baseline TIR was also associated with greater improvement in TIR on CLC (r = -0.81, P < 0.001). During CLC, participants in the highest versus lowest TIR-quartile administered more user-initiated boluses daily (8.5 ± 2.8 vs. 5.8 ± 2.6, P < 0.001) and received fewer automated boluses (3.5 ± 1.0 vs. 6.0 ± 1.6, P < 0.001). Participants in the lowest (vs. the highest) TIR-quartile received more insulin per body weight (1.13 ± 0.27 vs. 0.87 ± 0.20 U/kg/d, P = 0.008). However, in a multivariate model adjusting for baseline TIR, user-initiated boluses and insulin-per-body-weight were no longer significant. Conclusions: Higher baseline TIR is the strongest predictor of TIR on CLC in children with T1D. However, lower baseline TIR is associated with the greatest improvement in TIR. As with open-loop systems, user engagement is important for optimal glycemic control.


Assuntos
Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Adolescente , Glicemia , Automonitorização da Glicemia , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico
9.
Curr Nutr Rep ; 10(1): 47-57, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33411096

RESUMO

PURPOSE OF REVIEW: Here, we provide a review of recent advancements in closed-loop or automated insulin delivery systems commonly referred to as the "artificial pancreas" (AP) for the management of type 1 diabetes (T1D). RECENT FINDINGS: The use of hybrid closed-loop devices in children and adolescents with T1D consistently increases time in the target glucose range (70-180 mg/dL) without increasing the risk of hypoglycemia. Although hybrid closed-loop systems are able to maintain fairly tight glycemic control overnight, daytime control remains challenging, primarily due to meals and exercise, and careful carbohydrate counting and meal boluses remain essential components of optimal diabetes control. Bihormonal and fully automated AP systems remain investigational at this time. While commercially available hybrid closed-loop AP systems improve glycemic control in children with T1D, more work is needed to achieve a fully automated AP system and decrease the burden of using diabetes technology.


Assuntos
Diabetes Mellitus Tipo 1 , Pâncreas Artificial , Adolescente , Glicemia , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Insulina , Sistemas de Infusão de Insulina , Tecnologia
10.
Diabetes Technol Ther ; 23(6): 401-409, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33404325

RESUMO

Introduction: Hybrid closed-loop systems increase time-in-range (TIR) and reduce glycemic variability. Person-reported outcomes (PROs) are essential to assess the utility of new devices and their impact on quality of life. This article focuses on the PROs for pediatric participants (ages 6-13 years) with type 1 diabetes (T1D) and their parents during a trial using the Tandem Control-IQ system, which was shown to increase TIR and improve other glycemic metrics. Research Design and Methods: One hundred and one children 6 to 13 years old with T1D were randomly assigned to closed-loop control (CLC) or sensor-augmented pump (SAP) in a 16-week randomized clinical trial with extension to 28 weeks during which the SAP group crossed over to CLC. Health-related quality of life and treatment satisfaction measures were obtained from children and their parents at baseline, 16 weeks, and 28 weeks. Results: Neither the children in the CLC group nor their parents had statistically significant changes in PRO outcomes compared with the SAP group at the end of the 16-week randomized controlled trial and the 28-week extension. Parents in the CLC group reported nonsignificant improvements in some PRO scores when compared with the SAP group at 16 weeks, which were sustained at 28 weeks. Sleep scores for parents improved from "poor sleep quality" to "adequate sleep quality" between baseline and 16 weeks, however, the change in scores was not statistically different between groups. Conclusions: Children with T1D who used the Control-IQ system did not experience increased burden compared with those using SAP based on person-reported outcomes from the children and their parents. Clinical Trials Registration: NCT03844789.


Assuntos
Diabetes Mellitus Tipo 1 , Qualidade de Vida , Adolescente , Glicemia , Automonitorização da Glicemia , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Pais , Satisfação Pessoal
11.
Diabetes Care ; 44(2): 473-478, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33355258

RESUMO

OBJECTIVE: To further evaluate the safety and efficacy of the Control-IQ closed-loop control (CLC) system in children with type 1 diabetes. RESEARCH DESIGN AND METHODS: After a 16-week randomized clinical trial (RCT) comparing CLC with sensor-augmented pump (SAP) therapy in 101 children 6-13 years old with type 1 diabetes, 22 participants in the SAP group initiated use of the CLC system (referred to as SAP-CLC cohort), and 78 participants in the CLC group continued use of CLC (CLC-CLC cohort) for 12 weeks. RESULTS: In the SAP-CLC cohort, mean percentage of time in range 70-180 mg/dL (TIR) increased from 55 ± 13% using SAP during the RCT to 65 ± 10% using CLC (P < 0.001), with 36% of the cohort achieving TIR >70% plus time <54 mg/dL <1% compared with 14% when using SAP (P = 0.03). Substantial improvement in TIR was seen after the 1st day of CLC. Time <70 mg/dL decreased from 1.80% to 1.34% (P < 0.001). In the CLC-CLC cohort, mean TIR increased from 53 ± 17% prerandomization to 67 ± 10% during the RCT and remained reasonably stable at 66 ± 10% through the 12 weeks post-RCT. No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either cohort. CONCLUSIONS: This further evaluation of the Control-IQ CLC system supports the findings of the preceding RCT that use of a closed-loop system can safely improve glycemic control in children 6-13 years old with type 1 diabetes from the 1st day of use and demonstrates that these improvements can be sustained through 28 weeks of use.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adolescente , Glicemia , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
12.
Pediatr Diabetes ; 22(3): 495-502, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33289242

RESUMO

BACKGROUND: Data on the use of Control-IQ, the latest FDA-approved automated insulin delivery (AID) system for people with T1D 6 years of age or older is still scarce, particularly regarding nonglycemic outcomes. Children with T1D and their parents are at higher risk for sleep disturbances. This study assesses sleep, psycho-behavioral and glycemic outcomes of AID compared to sensor-augmented pump therapy (SAP) therapy in young children with T1D and their parents. METHODS: Thirteen parents and their young children (ages 7-10) on insulin pump therapy were enrolled. Children completed an initial 4-week study with SAP using their own pump and a study CGM followed by a 4-week phase of AID. Sleep outcomes for parents and children were evaluated through actigraphy watches. Several questionnaires were administered at baseline and at the end of each study phase. CGM data were used to assess glycemic outcomes. RESULTS: Actigraphy data did not show any significant change from SAP to AID, except a reduction of number of parental awakenings during the night (p = 0.036). Parents reported statistically significant improvements in Pittsburgh Sleep Quality Index total score (p = 0.009), Hypoglycemia Fear Survey total score (p = 0.011), diabetes-related distress (p = 0.032), and depression (p = 0.023). While on AID, time in range (70-180 mg/dL) significantly increased compared to SAP (p < 0.001), accompanied by a reduction in hyperglycemia (p = 0.001). CONCLUSIONS: These results suggest that use of AID has a positive impact on glycemic outcomes in young children as well as sleep and diabetes-specific quality of life outcomes in their parents.


Assuntos
Diabetes Mellitus Tipo 1/psicologia , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pais/psicologia , Qualidade do Sono , Adulto , Automonitorização da Glicemia , Criança , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Inquéritos e Questionários
13.
Diabetes Technol Ther ; 23(5): 384-391, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33226837

RESUMO

Background: Glycemic control is particularly challenging for toddlers and preschoolers with type 1 diabetes (T1D), and data on the use of closed-loop systems in this age range are limited. Materials and Methods: We studied use of a modified investigational version of the Tandem t:slim X2 Control-IQ system in children aged 2 to 5 years during 48 h in an outpatient supervised hotel (SH) setting followed by 3 days of home use to examine the safety of this system in young children. Meals and snacks were not restricted and boluses were estimated per parents' usual routine. At least 30 min of daily exercise was required during the SH phase. All participants were remotely monitored by study staff while on closed-loop in addition to monitoring by at least one parent throughout the study. Results: Twelve participants diagnosed with T1D for at least 3 months with mean age 4.7 ± 1.0 years (range 2.0-5.8 years) and hemoglobin A1c of 7.3% ± 0.8% were enrolled at three sites. With use of Control-IQ, the percentage of participants meeting our prespecified goals of less than 6% time below 70 mg/dL and less than 40% time above 180 mg/dL increased from 33% to 83%. Control-IQ use significantly improved percent time in range (70-180 mg/dL) compared to baseline (71.3 ± 12.5 vs. 63.7 ± 15.1, P = 0.016). All participants completed the study with no adverse events. Conclusions: In this brief pilot study, use of the modified Control-IQ system was safe in 2-5-year-old children with T1D and improved glycemic control.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Glicemia , Pré-Escolar , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Projetos Piloto
14.
N Engl J Med ; 383(9): 836-845, 2020 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-32846062

RESUMO

BACKGROUND: A closed-loop system of insulin delivery (also called an artificial pancreas) may improve glycemic outcomes in children with type 1 diabetes. METHODS: In a 16-week, multicenter, randomized, open-label, parallel-group trial, we assigned, in a 3:1 ratio, children 6 to 13 years of age who had type 1 diabetes to receive treatment with the use of either a closed-loop system of insulin delivery (closed-loop group) or a sensor-augmented insulin pump (control group). The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. RESULTS: A total of 101 children underwent randomization (78 to the closed-loop group and 23 to the control group); the glycated hemoglobin levels at baseline ranged from 5.7 to 10.1%. The mean (±SD) percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter increased from 53±17% at baseline to 67±10% (the mean over 16 weeks of treatment) in the closed-loop group and from 51±16% to 55±13% in the control group (mean adjusted difference, 11 percentage points [equivalent to 2.6 hours per day]; 95% confidence interval, 7 to 14; P<0.001). In both groups, the median percentage of time that the glucose level was below 70 mg per deciliter was low (1.6% in the closed-loop group and 1.8% in the control group). In the closed-loop group, the median percentage of time that the system was in the closed-loop mode was 93% (interquartile range, 91 to 95). No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either group. CONCLUSIONS: In this 16-week trial involving children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with the use of a closed-loop system than with the use of a sensor-augmented insulin pump. (Funded by Tandem Diabetes Care and the National Institute of Diabetes and Digestive and Kidney Diseases; ClinicalTrials.gov number, NCT03844789.).


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Bombas de Infusão Implantáveis , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adolescente , Glicemia/análise , Criança , Diabetes Mellitus Tipo 1/sangue , Cetoacidose Diabética/etiologia , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/efeitos adversos , Injeções Subcutâneas , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pâncreas Artificial
15.
Endocr Rev ; 41(3)2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32115641

RESUMO

We provide an in-depth review of the role of androgens in male maturation and development, from the fetal stage through adolescence into emerging adulthood, and discuss the treatment of disorders of androgen production throughout these time periods. Testosterone, the primary androgen produced by males, has both anabolic and androgenic effects. Androgen exposure induces virilization and anabolic body composition changes during fetal development, influences growth and virilization during infancy, and stimulates development of secondary sexual characteristics, growth acceleration, bone mass accrual, and alterations of body composition during puberty. Disorders of androgen production may be subdivided into hypo- or hypergonadotropic hypogonadism. Hypogonadotropic hypogonadism may be either congenital or acquired (resulting from cranial radiation, trauma, or less common causes). Hypergonadotropic hypogonadism occurs in males with Klinefelter syndrome and may occur in response to pelvic radiation, certain chemotherapeutic agents, and less common causes. These disorders all require testosterone replacement therapy during pubertal maturation and many require lifelong replacement. Androgen (or gonadotropin) therapy is clearly beneficial in those with persistent hypogonadism and self-limited delayed puberty and is now widely used in transgender male adolescents. With more widespread use and newer formulations approved for adults, data from long-term randomized placebo-controlled trials are needed to enable pediatricians to identify the optimal age of initiation, route of administration, and dosing frequency to address the unique needs of their patients.


Assuntos
Androgênios/fisiologia , Hipogonadismo/tratamento farmacológico , Desenvolvimento Sexual , Testosterona/fisiologia , Adolescente , Androgênios/sangue , Androgênios/uso terapêutico , Criança , Pré-Escolar , Terapia de Reposição Hormonal , Humanos , Hipogonadismo/fisiopatologia , Lactente , Síndrome de Klinefelter/tratamento farmacológico , Síndrome de Klinefelter/fisiopatologia , Masculino , Puberdade , Testosterona/sangue , Testosterona/uso terapêutico
16.
Diabetes Technol Ther ; 22(8): 594-601, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32119790

RESUMO

Objective: To assess the safety and efficacy of a simplified initialization for the Tandem t:slim X2 Control-IQ hybrid closed-loop system, using parameters based on total daily insulin ("MyTDI") in adolescents with type 1 diabetes under usual activity and during periods of increased exercise. Research Design and Methods: Adolescents with type 1 diabetes 12-18 years of age used Control-IQ for 5 days at home using their usual parameters. Upon arrival at a 60-h ski camp, participants were randomized to either continue Control-IQ using their home settings or to reinitialize Control-IQ with MyTDI parameters. Control-IQ use continued for 5 days following camp. The effect of MyTDI on continuous glucose monitoring outcomes were analyzed using repeated measures analysis of variance (ANOVA): baseline, camp, and at home. Results: Twenty participants were enrolled and completed the study; two participants were excluded from the analysis due to absence from ski camp (1) and illness (1). Time in range was similar between both groups at home and camp. A tendency to higher time <70 mg/dL in the MyTDI group was present but only during camp (median 3.8% vs. 1.4%, P = 0.057). MyTDI users with bolus/TDI ratios >40% tended to show greater time in the euglycemic range improvements between baseline and home than users with ratios <40% (+16.3% vs. -9.0%, P = 0.012). All participants maintained an average of 95% time in closed loop (84.1%-100%). Conclusions: MyTDI is a safe, effective, and easy way to determine insulin parameters for use in the Control-IQ artificial pancreas. Future modifications to account for the influence of carbohydrate intake on MyTDI calculations might further improve time in range.


Assuntos
Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Pâncreas Artificial , Adolescente , Glicemia , Automonitorização da Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico
17.
J Endocr Soc ; 1(9): 1160-1167, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-29264571

RESUMO

CONTEXT: Hypercalcemia is reported as a rare finding in adrenal insufficiency, but is not well described in congenital adrenal hyperplasia (CAH). METHODS: A retrospective chart review was conducted of patients with CAH diagnosed before the age of 2 years who had at least one recorded serum calcium measurement. Data from birth to 6 years of age were reviewed. RESULTS: Of the 40 patients who met inclusion criteria, 33 (82.5%) had at least one elevated calcium concentration and 21 (53%) had two or more elevated calcium concentrations. Of the 126 elevated serum calcium concentrations, the median was 10.9 mg/dL (range, 10.6 to 14.2 mg/dL). Median age at the last elevated calcium measurement was 5 months (range, 0.3 to 46 months). Serum calcium concentration was inversely related to age (r = -0.124; P = 0.004). Overall, calcium level positively correlated with 17-hydroxyprogesterone (17OHP) concentration (r = 0.170; P = 0.003), and this remained significant after adjusting for age (P < 0.05). However, patients had hypercalcemia with both high and low 17OHP concentrations. Serum calcium concentration also was positively related to glucocorticoid (r = 0.196; P = 0.012) and fludrocortisone (r = 0.229; P = 0.003) doses, and remained significant after age adjustment. Only seven patients were evaluated for hypercalciuria. Of these, six had at least one period of documented hypercalciuria. Three patients had nephrocalcinosis on renal ultrasound. CONCLUSION: Children with CAH are at risk for developing hypercalcemia, hypercalciuria, and nephrocalcinosis. Further studies are needed to determine the broader prevalence and the etiology of hypercalcemia in CAH.

18.
Horm Res Paediatr ; 88(5): 347-353, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28926827

RESUMO

BACKGROUND: To determine whether psychological characteristics of girls with variations of early puberty and their mothers change over time and with treatment in girls with central precocious puberty (CPP). METHODS: Girls with CPP, premature adrenarche (PA), and early normal puberty (ENP) completed psychological assessments at baseline and after 1 year along with their mothers. All girls with CPP were treated with GnRH analogs. Psychological effects of group and time were examined using 2 × 3 mixed ANOVAs. RESULTS: Sixty-two subjects aged 7.5 ± 1.4 years (range 4.8-10.5) were enrolled, of whom 36 (15 with CPP, 8 with PA, and 13 with ENP) completed 1-year follow-up assessments. Psychological measures were normal in all girls. No significant group differences were found for any measure of girls' psychological functioning at either time point. However, across all groups there was change over time with a decrease in perceived physical competence (p < 0.001) and an increase in perceived maternal acceptance (p = 0.001). CONCLUSION: No abnormalities in psychological functioning were found among girls with variations of early puberty, and all groups were in the normal range. Our results are largely reassuring regarding concerns of adverse psychological consequences of early puberty in girls.


Assuntos
Adrenarca/psicologia , Mães/psicologia , Puberdade Precoce/psicologia , Ajustamento Social , Ansiedade/psicologia , Criança , Pré-Escolar , Depressão/psicologia , Feminino , Seguimentos , Humanos , Personalidade
19.
Endocr Pract ; 23(9): 1067-1071, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28683242

RESUMO

OBJECTIVE: The purpose of this study was to determine if infants with congenital hypothyroidism (CH) whose initial dose of levothyroxine (LT4) is based on thyroid gland anatomy require fewer dose adjustments in the first 6 months of life than those who were started empirically on LT4. METHODS: Newborns with CH who had a thyroid ultrasound performed at diagnosis were eligible for this prospective, historical case-controlled study. The daily LT4 dose prescribed was based on results on the thyroid ultrasound as follows: 15 mcg/kg for athyreosis, 12 mcg/kg for a dysgenetic thyroid, and 10 mcg/kg for an anatomically normal gland. Routine labs according to standard guidelines were obtained, and the number of dose adjustments over the first 6 months of therapy was recorded. Each study participant was matched with 2 historical controls with CH based on sex and thyroid anatomy. RESULTS: Twenty-two subjects (10 with athyreosis, 4 with dysgenetic glands, and 8 with anatomically normal glands) were matched to 44 controls. There was no significant difference in the overall number of adjustments in the study group compared to controls (P = .74). However, there were significantly fewer adjustments made for undertreatment (P = .03) and significantly more adjustments made for overtreatment (P = .006) in subjects with athyreosis compared to controls. CONCLUSION: Targeted LT4 therapy does not appear to decrease the overall frequency of dose adjustments for infants with CH. However, 15 mcg/kg/day appears to exceed thyroid hormone requirements in infants with CH due to athyreosis. ABBREVIATIONS: CH = congenital hypothyroidism LT4 = levothyroxine OT = overtreatment T4 = thyroxine TSH = thyroid-stimulating hormone UT = undertreatment.


Assuntos
Hipotireoidismo Congênito/tratamento farmacológico , Tiroxina/uso terapêutico , Feminino , Humanos , Recém-Nascido , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA