Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiothorac Vasc Anesth ; 37(8): 1487-1494, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37120321

RESUMO

TACROLIMUS, a mainstay of immunosuppression after orthotopic heart transplantation (OHT), is associated with a broad range of side effects. Vasoconstriction caused by tacrolimus has been proposed as a mechanism underlying common side effects such as hypertension and renal injury. Neurologic side effects attributed to tacrolimus include headaches, posterior reversible encephalopathy syndrome (PRES), or reversible cerebral vasospasm syndrome (RCVS). Six case reports have been published describing RCVS in the setting of tacrolimus administration after OHT. The authors report a case of perfusion-dependent focal neurologic deficits attributed to tacrolimus-induced RCVS in an OHT recipient.


Assuntos
Transplante de Coração , Síndrome da Leucoencefalopatia Posterior , Vasoespasmo Intracraniano , Humanos , Tacrolimo/efeitos adversos , Vasoespasmo Intracraniano/induzido quimicamente , Vasoespasmo Intracraniano/diagnóstico por imagem , Síndrome da Leucoencefalopatia Posterior/induzido quimicamente , Síndrome da Leucoencefalopatia Posterior/diagnóstico por imagem , Estado Terminal , Perfusão/efeitos adversos , Transplante de Coração/efeitos adversos
2.
J Cardiothorac Vasc Anesth ; 33(3): 717-724, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30583929

RESUMO

OBJECTIVE: To assess the agreement between 2-dimensional tricuspid annular plane systolic excursion (2D-TAPSE), 2D-TAPSE-apex, and 2D speckle tracking echocardiography (STE-TAPSE) in a cross-section of routine cardiac surgery patients. DESIGN: Retrospective, observational study. SETTING: Tertiary, academic referral hospital. PARTICIPANTS: Patients undergoing elective cardiac surgery with intraoperative transesophageal echocardiography (TEE) imaging. INTERVENTIONS: TEE imaging was reviewed and evaluated for the following three different measurements of transthoracic echocardiography-TAPSE surrogates: 2D-TAPSE, 2D-TAPSE-apex, and STE-TAPSE. Statistical analyses, including 2-sample t tests, linear regression, and agreement using the Bland-Altman methods, were performed. MEASUREMENTS AND MAIN RESULTS: Modest correlation was demonstrated between STE-TAPSE and 2D-TAPSE (R2 = 0.37; p < 0.001) and between STE-TAPSE and 2D-TAPSE-apex (R2 = 0.34; p < 0.001). There was good correlation between 2D-TAPSE and 2D-TAPSE-apex (R2 = 0.77, p < 0.001). The Bland-Altman analysis between these methods showed minimal bias: STE-TAPSE and 2D-TAPSE 0.84 mm, STE-TAPSE and 2D-TAPSE-apex 0.14 mm, and 2D-TAPSE and 2D-TAPSE-apex 0.98 mm. However, the agreement was poor, with 95% limits of agreement of -10.67 to 8.99 mm, -10.67 to 10.96 mm, and -4.91 to 6.88 mm, respectively. CONCLUSIONS: Correlation and minimal bias were found between the several proposed TEE surrogates of transthoracic echocardiography-TAPSE; however, there was poor agreement. Therefore, these surrogates are not interchangeable, and each method needs to be separately validated for clinical use to relevant perioperative outcomes.


Assuntos
Pressão Sanguínea/fisiologia , Procedimentos Cirúrgicos Cardíacos/normas , Ecocardiografia Transesofagiana/normas , Monitorização Intraoperatória/normas , Valva Tricúspide/efeitos dos fármacos , Valva Tricúspide/fisiologia , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Estudos de Coortes , Ecocardiografia/métodos , Ecocardiografia/normas , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA