Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Circ Heart Fail ; 17(5): e011435, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38695186

RESUMO

Hypertrophic cardiomyopathy is the most common genetic cardiac disease and is characterized by left ventricular hypertrophy. Although this hypertrophy often associates with sarcomeric gene mutations, nongenetic factors also contribute to the disease, leading to diastolic dysfunction. Notably, this dysfunction manifests before hypertrophy and is linked to hypercontractility, as well as nonuniform contraction and relaxation (myofibril asynchrony) of the myocardium. Although the distribution of hypertrophy in hypertrophic cardiomyopathy can vary both between and within individuals, in most cases, it is primarily confined to the interventricular septum. The reasons for septal thickening remain largely unknown. In this article, we propose that alterations in muscle fiber geometry, present from birth, dictate the septal shape. When combined with hypercontractility and exacerbated by left ventricular outflow tract obstruction, these factors predispose the septum to an isometric type of contraction during systole, consequently constraining its mobility. This contraction, or more accurately, this focal increase in biomechanical stress, prompts the septum to adapt and undergo remodeling. Drawing a parallel, this is reminiscent of how earthquake-resistant buildings are retrofitted with vibration dampers to absorb the majority of the shock motion and load. Similarly, the heart adapts by synthesizing viscoelastic elements such as microtubules, titin, desmin, collagen, and intercalated disc components. This pronounced remodeling in the cytoskeletal structure leads to noticeable septal hypertrophy. This structural adaptation acts as a protective measure against damage by attenuating myofibril shortening while reducing cavity tension according to Laplace Law. By examining these events, we provide a coherent explanation for the septum's predisposition toward hypertrophy.


Assuntos
Cardiomiopatia Hipertrófica , Humanos , Cardiomiopatia Hipertrófica/fisiopatologia , Contração Miocárdica/fisiologia , Animais , Remodelação Ventricular/fisiologia , Septos Cardíacos/fisiopatologia , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/patologia , Septo Interventricular/fisiopatologia , Septo Interventricular/diagnóstico por imagem
2.
Eur Heart J Case Rep ; 8(1): ytad640, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38213867

RESUMO

Background: In more than 90%, transcatheter aortic valve implantation (TAVI) is performed via transfemoral access. Alternative access routes are necessary for patients with unfavourable femoral arteries. Case summary: We report of a 68-year-old female with symptomatic severe aortic stenosis in whom surgical aortic valve replacement was prohibited due to her severe co-morbidities. Both femoral arteries and both subclavian arteries were unsuitable for TAVI access. Surgical aortic valve replacement and transapical TAVI were deferred due to extremely high operative risk and very low originating left coronary artery of 7 mm from the annulus. Hence, we decided to implant a self-expanding TAVI device with a low risk of coronary obstruction (Acurate Neo 2 prosthesis) via transaortic approach, which to our knowledge is the first case worldwide. Conclusion: The present case demonstrates the feasibility of implanting the Acurate Neo 2 system via transaortic approach when certain key points are respected. Transaortic TAVI with the Acurate Neo 2 offers a minimally invasive treatment of high operative risk patients with low originating coronary arteries.

3.
Clin Res Cardiol ; 113(2): 336-352, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38170247

RESUMO

BACKGROUND AND AIMS: Prosthetic valve endocarditis (PVE) is the prognostically most unfavourable complication after aortic valve replacement. This study aims to contribute to a better understanding of the different pathological and therapeutical aspects between PVE following surgical (SAVR) and transcatheter aortic valve replacement (TAVI). METHODS: All patients who had undergone primary isolated SAVR (n = 3447) or TAVI (n = 2269) at our Centre between 01/2012 and 12/2018 were analysed. Diagnosis of PVE was based on Duke criteria modified in 2015. Incidence, risk factors, pathogens, impact of complications or therapy on mortality were analysed and compared between SAVR- and TAVI-PVE. RESULTS: PVE incidence did not differ significantly after SAVR with 4.9/100 patient-years and TAVI with 2.4/100 patient-years (p = 0.49), although TAVI patients were older (mean 80 vs. 67 years) and had more comorbidities (STS score mean 5.9 vs. 1.6) (p < 0.001). TAVI prostheses with polymer showed a 4.3-fold higher risk to develop PVE than without polymer (HR 4.3; p = 0.004). Most common pathogens were staphylococci and enterococci (p > 0.05). Propensity-score matching analysis showed that the type of aortic valve replacement had no effect on the development of post-procedural PVE (p = 0.997). One-year survival was higher in TAVI-PVE patients treated with antibiotics only compared to additional surgical therapy (90.9% vs. 33.3%; p = 0.005). In SAVR-PVE patients, both therapies were comparable in terms of survival (p = 0.861). However, SAVR-PVE patients who were not operated, despite ESC-guideline recommendation, had significantly poorer one-year survival (p = 0.004). CONCLUSION: TAVI patients did not have a significantly higher risk to develop PVE. Our data suggest that TAVI-PVE patients in contrast to SAVR-PVE patients can more often be treated with antibiotics only, presumably due to the lack of a polymeric suture ring.


Assuntos
Estenose da Valva Aórtica , Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Endocardite/epidemiologia , Fatores de Risco , Instrumentos Cirúrgicos , Antibacterianos/uso terapêutico , Polímeros , Catéteres/efeitos adversos , Resultado do Tratamento
4.
Hellenic J Cardiol ; 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37944865

RESUMO

OBJECTIVE: The aim of this study was to investigate the proportion of elevated left ventricular end-diastolic pressure (LVEDP) as an indicator of diastolic function after transcatheter aortic valve replacement (TAVR) and its implication in predicting long-term mortality. METHODS: We analyzed retrospectively collected data on 3328 patients with severe aortic stenosis undergoing TAVR in our institution between July 2009 and June 2021. Patients were stratified into two groups based on invasive post-procedural LVEDP measurements: normal (<15 mmHg) vs. elevated (≥15 mmHg) LVEDP. RESULTS: Mean age of the patients was 81.6 years, and 53.3% were female. Elevated post-procedural LVEDP was identified in 2408 (72.3%) patients. The 5-year mortality rates were higher in the group with elevated LVEDP compared with the group with normal LVEDP (27.4% vs. 8.3%, p = 0.01; hazard ratio [HR] 1.22, 95% CI 1.05-1.41). A multivariate model revealed the following independent predictors of mortality after TAVR: post-procedural elevated LVEDP (HR 1.24, 95% CI 1.01-1.53), pre-procedural significant tricuspid regurgitation (HR 1.24, 95% CI 1.02-1.52) and pulmonary hypertension (PH) (HR 1.53, 95% CI 1.26-1.86). In the present study, a significant paravalvular leak after TAVR was not associated with higher mortality (HR 1.45, 95% CI-0.95-2.19, p = 0.75). CONCLUSION: Elevated post-procedural LVEDP in patients who undergo TAVR is an independent predictor of all-cause mortality. Furthermore, PH and tricuspid regurgitation were also identified as predictors of mortality. These data confirm that diastolic dysfunction is an important predictor of mortality in TAVR and should be considered to guide procedure timing, favoring an early interventional approach and management in aortic stenosis patients.

5.
J Clin Med ; 12(20)2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37892766

RESUMO

Hypertrophic cardiomyopathy (HCM) is a genetic disease characterized by an increased left ventricular wall thickness in the absence of increased afterload conditions. In addition to diastolic dysfunction, obstruction of the left ventricular outflow tract is common in HCM and has an important influence on symptoms and outcome. Over the last five decades or two decades, respectively, surgical myectomy and alcohol septal ablation were the only therapeutic options if standard medical care was not sufficient. Recently, a new option has become available that has the potential to revolutionize the therapeutic strategies for patients with HCM. Mavacamten is a myosin inhibitor that belongs to a completely new drug class and targets the excessive actin-myosin cross-bridging that is the underlying pathology of HCM. By reducing the actin-myosin interactions, mavacamten not only reduces the left ventricular outflow tract (LVOT) obstruction but also seems to have positive effects on the diastolic function, microcirculation, and cardiac structure. This article summarizes the current evidence on alcohol septal ablation and reviews the preclinical and clinical data on mavacamten for the treatment of patients with obstructive HCM.

6.
EuroIntervention ; 18(13): e1077-e1087, 2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36128956

RESUMO

BACKGROUND: No detailed data on left bundle branch block (LBBB) and permanent pacemaker implantation (PPI) exist from randomised clinical trials comparing the ACURATE neo and CoreValve Evolut devices. AIMS: Our aim was to assess the incidence and impact of new LBBB and PPI with self-expanding prostheses from a powered randomised comparison. METHODS: From the SCOPE 2 trial, 648 patients with no previous pacemaker were analysed for PPI at 30 days, and 426 patients without previous LBBB were adopted for analysis of LBBB at 30 days.  Results: At 30 days, 16.5% of patients required PPI; rates were higher in CoreValve Evolut compared to ACURATE neo recipients (21.0% vs 12.3%; p=0.004). Previous right bundle branch block (odds ratio [OR] 6.11, 95% confidence interval [CI]: 3.19-11.73; p<0.001) was associated with an increased risk of PPI at 30 days, whereas the use of the ACURATE neo (OR 0.50, 95% CI: 0.31-0.81; p=0.005) was associated with a decreased risk. One-year mortality was similar in patients with and without new PPI. A total of 9.4% of patients developed persistent LBBB at 30 days, with higher incidences in CoreValve Evolut recipients (13.4% vs 5.5%; p=0.007). New LBBB at 30 days was associated with lower ejection fraction at 1 year (65.7%±11.0 vs 69.1%±7.6; p=0.041). CONCLUSIONS: New LBBB and PPI rates were lower in ACURATE neo compared to CoreValve Evolut recipients. The ACURATE neo valve was associated with a lower risk of PPI at 30 days. No effect on 1-year mortality was determined for PPI at 30 days, while LBBB at 30 days was associated with reduced ejection fraction at 1 year.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Bloqueio de Ramo/terapia , Bloqueio de Ramo/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Valva Aórtica/cirurgia , Fatores de Risco
7.
Echocardiography ; 39(11): 1462-1465, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36266720

RESUMO

Cardiac lipomas are the second most common cardiac tumors. They are usually asymptomatic and diagnosed as incidental findings. We describe a 71-year-old patient with a tumor in the right atrium. In echocardiography and MRI scan, the diagnosis of a cardiac lipoma was suspected. Moreover, MRI demonstrated continuity of pericardial fat and the tumor in the right atrium by infolding of the atrial wall and epicardial adipose tissue in the space between the atrial walls, which might be a hint for the Waterstone groove hypothesis. An operative resection was performed which confirmed the suspected diagnosis.


Assuntos
Neoplasias Cardíacas , Lipoma , Humanos , Idoso , Resultado do Tratamento , Lipoma/complicações , Lipoma/diagnóstico por imagem , Átrios do Coração/patologia , Neoplasias Cardíacas/complicações , Neoplasias Cardíacas/diagnóstico por imagem , Ecocardiografia
8.
J Clin Med ; 11(15)2022 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-35956185

RESUMO

BACKGROUND: Treatment of severely calcified aortic valve stenosis is associated with a higher rate of paravalvular leakage (PVL) and permanent pacemaker implantation (PPI). We hypothesized that the self-expanding transcatheter heart valve (THV) prostheses Evolut Pro (EPro) is comparable to the balloon-expandable Sapien 3 (S3) regarding hemodynamics, PPI, and clinical outcome in these patients. METHODS: From 2014 to 2019, all patients with very severe calcification of the aortic valve who received an EPro or an S3 THV were included. Propensity score matching was utilized to create two groups of 170 patients. RESULTS: At discharge, there was significant difference in transvalvular gradients (EPro vs. S3) (dPmean 8.1 vs. 11.1 mmHg, p ≤ 0.001) and indexed effective orifice area (EOAi) (1.1 vs. 0.9, p ≤ 0.001), as well as predicted EOAi (1 vs. 0.9, p ≤ 0.001). Moderate patient prosthesis mismatch (PPM) was significantly lower in the EPro group (17.7% vs. 38%, p ≤ 0.001), as well as severe PPM (2.9% vs. 8.8%, p = 0.03). PPI and the PVL rate as well as stroke, bleeding, vascular complication, and 30-day mortality were comparable. CONCLUSIONS: In patients with severely calcified aortic valves, both THVs performed similarly in terms of 30-day mortality, PPI rate, and PVL occurrence. However, patient prothesis mismatch was observed more often in the S3 group, which might be due to the intra-annular design.

9.
EuroIntervention ; 18(6): 503-513, 2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-35450838

RESUMO

BACKGROUND: The Academic Research Consortium - High Bleeding Risk (ARC-HBR) initiative defined conditions associated with percutaneous coronary intervention (PCI)-related bleeding. AIMS: We sought to further explore these HBR conditions in the setting of transcatheter aortic valve replacement (TAVR). METHODS: Patients from the SCOPE 2 trial were stratified by their bleeding risk status based on the ARC-HBR definitions. Baseline and procedural characteristics, as well as key clinical outcomes including Bleeding Academic Research Consortium (BARC) 3-5 bleeding, were compared in ARC-HBR positive (HBR+) and ARC-HBR negative (HBR-) patients. RESULTS: Of 787 patients randomised in SCOPE 2 and included in this study, 633 were HBR+ (80.4%). Compared with HBR- patients, those HBR+ were older and more frequently presented with diabetes, a history of coronary artery disease, atrial fibrillation, prior cerebrovascular accident, and a Society of Thoracic Surgeons predicted risk of 30-day mortality (STS-PROM) (4.9±2.9% vs 3.3%±2.1%; p<0.0001). In addition, HBR+ patients were more frequently on oral anticoagulation therapy. At 1 year, HBR+ patients had higher rates of all-cause death (12.4% vs 4.3%, respectively, risk difference 8.09%; 95% confidence interval [CI]: 3.76-12.41; p=0.0002); the rates of BARC 3-5 type bleeding were relatively high but not statistically different compared with HBR- patients (7.7% vs 6.1%, risk difference 1.67%; 95% CI: -2.72 to 6.06; p=0.46). Subgroup analyses for bleeding events showed no significant interaction in terms of STS-PROM score, age, or medications. CONCLUSIONS: The ARC-HBR criteria failed to isolate a subgroup of patients at higher bleeding risk in TAVR patients from a randomised trial. These findings have potential implications, especially for the selection of post-TAVR antithrombotic regimens based on individual bleeding-risk profiles. Specific HBR criteria should be defined for TAVR patients.


Assuntos
Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Hemorragia/induzido quimicamente , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Medição de Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Circulation ; 142(25): 2431-2442, 2020 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-33054367

RESUMO

BACKGROUND: Few randomized trials have compared bioprostheses for transcatheter aortic valve replacement, and no trials have compared bioprostheses with supra-annular design. The SCOPE 2 trial (Safety and Efficacy Comparison of Two TAVI Systems in a Prospective Randomized Evaluation 2) was designed to compare the clinical outcomes of the ACURATE neo and CoreValve Evolut bioprostheses for transcatheter aortic valve replacement. METHODS: SCOPE 2 was a randomized trial performed at 23 centers in 6 countries between April 2017 and April 2019. Patients ≥75 years old with an indication for transfemoral transcatheter aortic valve replacement as agreed by the heart team were randomly assigned to receive treatment with either the ACURATE neo (n=398) or the CoreValve Evolut bioprostheses (n=398). The primary end point, powered for noninferiority of the ACURATE neo bioprosthesis, was all-cause death or stroke at 1 year. The key secondary end point, powered for superiority of the ACURATE neo bioprosthesis, was new permanent pacemaker implantation at 30 days. RESULTS: Among 796 randomized patients (mean age, 83.2±4.3 years; mean Society of Thoracic Surgeons Predicted Risk of Mortality score, 4.6±2.9%), clinical follow-up information was available for 778 (98%) patients. Within 1 year, the primary end point occurred in 15.8% of patients in the ACURATE neo group and in 13.9% of patients in the CoreValve Evolut group (absolute risk difference, 1.8%, upper 1-sided 95% confidence limit, 6.1%; P=0.0549 for noninferiority). The 30-day rates of new permanent pacemaker implantation were 10.5% in the ACURATE neo group and 18.0% in the CoreValve Evolut group (absolute risk difference, -7.5% [95% CI, -12.4 to -2.60]; P=0.0027). No significant differences were observed in the components of the primary end point. Cardiac death at 30 days (2.8% versus 0.8%; P=0.03) and 1 year (8.4% versus 3.9%; P=0.01), and moderate or severe aortic regurgitation at 30 days (10% versus 3%; P=0.002) were significantly increased in the ACURATE neo group. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement with the self-expanding ACURATE neo did not meet noninferiority compared with the self-expanding CoreValve Evolut in terms of all-cause death or stroke at 1 year, and it was associated with a lower incidence of new permanent pacemaker implantation. In secondary analyses, the ACURATE neo was associated with more moderate or severe aortic regurgitation at 30 days and cardiac death at 30 days and 1 year. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03192813.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Europa (Continente) , Feminino , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
11.
Open Heart ; 7(1)2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32393655

RESUMO

OBJECTIVE: Residual paravalvular regurgitation (PVR) has been associated to adverse outcomes after transcatheter aortic valve replacement (TAVR). This study sought to evaluate the impact of device landing zone (DLZ) calcification on residual PVR after TAVR with different next-generation transcatheter heart valves. METHODS: 642 patients underwent TAVR with a SAPIEN 3 (S3; n=292), ACURATE neo (NEO; n=166), Evolut R (ER; n=132) or Lotus (n=52). Extent, location and asymmetry of DLZ calcification were assessed from contrast-enhanced CT imaging and correlated to PVR at discharge. RESULTS: PVR was ≥moderate in 0.7% of S3 patients, 9.6% of NEO patients, 9.8% of ER patients and 0% of Lotus patients (p<0.001), and these differences remained after matching for total DLZ calcium volume. The amount of DLZ calcium was significantly related to the degree of PVR in patients treated with S3 (p=0.045), NEO (p=0.004) and ER (p<0.001), but not in Lotus patients (p=0.698). The incidence of PVR ≥moderate increased significantly over the tertiles of DLZ calcium volume (p=0.046). On multivariable analysis, calcification of the aortic valve cusps, LVOT calcification and the use of self-expanding transcatheter aortic valve implantation (TAVI) prostheses emerged as predictors of PVR. CONCLUSIONS: The susceptibility to PVR depending on the amount of calcium was mainly observed in self-expanding TAVI prostheses. Thus, DLZ calcification is an important factor to be considered in prosthesis selection for each individual patient, keeping in mind the trade-off between PVR reduction, risk of new pacemaker implantation and unfavourable valve ha emodynamics.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/fisiopatologia , Feminino , Alemanha , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
12.
J Invasive Cardiol ; 31(9): 260-264, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31478891

RESUMO

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) has become standard therapy for aortic stenosis patients with intermediate or high operative risk. Treatment of patients with pre-existing mechanical mitral valve replacement (MVR) is challenging due to possible interference between the TAVI prosthesis and MVR. We present our single-center experience with this special patient cohort. METHODS: A total of 1960 patients underwent TAVI at our institution between 2009 and March 2018; of these, 16 patients had pre-existing mechanical MVR. Device success and adverse events were analyzed according to the Valve Academic Research Consortium (VARC)-2 criteria. Patients were followed for at least 12 months. RESULTS: Mean patient age was 81.5 ± 4.4 years. The patients had a mean logistic EuroScore of 37.1 ± 13.5% and STS score of 7.1 ± 3.2%. Successful valve deployment was achieved in all patients, peri-interventional stroke rate was 0.0%, and permanent pacemaker was implanted in 2 patients (12.5%). Two patients experienced major complications, with blockage of the MVR disc in 1 patient and annulus rupture in 1 patient. Hence, 30-day mortality was 12.5% and 1-year mortality was 25.0%. CONCLUSION: TAVI in patients with mechanical MVR is challenging and requires careful preparation and choice of TAVI device. Repositionable and retrievable devices seem to be a safer option.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/complicações , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
13.
Eur Heart J ; 40(38): 3156-3165, 2019 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-31230081

RESUMO

AIMS: Peri-procedural transcatheter valve embolization and migration (TVEM) is a rare but potentially devastating complication of transcatheter aortic valve implantation (TAVI). We sought to assess the incidence, causes, and outcome of TVEM in a large multicentre cohort. METHODS AND RESULTS: We recorded cases of peri-procedural TVEM in patients undergoing TAVI between January 2010 and December 2017 from 26 international sites. Peri-procedural TVEM occurred in 273/29 636 (0.92%) TAVI cases (age 80.8 ± 7.3 years; 53.8% female), of which 217 were to the ascending aorta and 56 to the left ventricle. The use of self-expanding or first-generation prostheses and presence of a bicuspid aortic valve were independent predictors of TVEM. Bail-out measures included repositioning attempts using snares or miscellaneous tools (41.0%), multiple valve implantations (83.2%), and conversion to surgery (19.0%). Using 1:4-propensity matching, we identified a cohort of 235 patients with TVEM (TVEMPS) and 932 patients without TVEM (non-TVEMPS). In the matched cohort, all-cause mortality was higher in TVEMPS than in non-TVEMPS at 30 days (18.6% vs. 4.9%; P < 0.001) and after 1 year (30.5% vs. 16.6%; P < 0.001). Major stroke was more frequent in TVEMPS at 30 days (10.6% vs. 2.8%; P < 0.001), but not at 1 year (4.6% vs. 1.9%; P = 0.17). The need for emergent cardiopulmonary support, major stroke at 30 days, and acute kidney injury Stages 2 and 3 increased the risk of 1-year mortality, whereas a better renal function at baseline was protective. CONCLUSION: Transcatheter valve embolization and migration occurred in approximately 1% and was associated with increased morbidity and mortality.


Assuntos
Embolia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Embolia/epidemiologia , Embolia/etiologia , Embolia/mortalidade , Feminino , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Falha de Prótese/efeitos adversos , Falha de Prótese/etiologia , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento
14.
J Thorac Cardiovasc Surg ; 156(5): 1825-1834, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29861110

RESUMO

OBJECTIVES: Although transcatheter aortic valve implantation was the treatment of choice in inoperable and high-risk patients, the effect of transcatheter aortic valve implantation relative to conventional aortic valve replacement via ministernotomy in patients with moderate surgical risk remains unclear. METHODS: We consecutively enrolled patients who underwent minimally invasive aortic valve replacements via ministernotomy (n = 1929), transapical (n = 607), and transfemoral (n = 1273) aortic valve implantations from a single center during the period from July 2009 to July 2017. Of those, we conducted a 1:1:1 propensity score matching according to 23 preoperative risk factors. RESULTS: We were able to find 177 triplets (n = 531). The median European System for Cardiac Operative Risk Evaluation II was 3.0% versus 3.4% versus 2.9%, and Society of Thoracic Surgeons Predicted Risk of Mortality was 3.2% versus 3.6% versus 3.4%, respectively. According to the Valve Academic Research Consortium 2 criteria, there were no significant periprocedural differences regarding 30-day mortality (2.3% minimally invasive aortic valve replacement vs 4.5% transapical transcatheter aortic valve implantation vs 1.7% transfemoral transcatheter aortic valve implantation, P = .34), stroke (1.1% minimally invasive aortic valve replacement vs 0.6% transapical transcatheter aortic valve implantation vs 1.7% transfemoral transcatheter aortic valve implantation, P = .84), or myocardial infarction (0.6% minimally invasive aortic valve replacement vs 0.0% transapical transcatheter aortic valve implantation vs 0.0% transfemoral transcatheter aortic valve implantation, P = .83). Both intensive care and hospitalization times were significantly longer in the transapical group. Regarding midterm survival, transapical transcatheter aortic valve implantation was associated with a tendency toward a less favorable outcome (hazard ratio, 1.48; 95% confidence interval, 0.95-2.31; P = .17) compared with minimally invasive aortic valve replacement. CONCLUSIONS: In this real-world propensity score-matched minimally invasive aortic valve replacement, transapical transcatheter aortic valve implantation, transfemoral transcatheter aortic valve implantation cohort of intermediate-risk patients, early mortality was not significantly different, whereas the rates of periprocedural complications were different depending on the approach. During follow-up, there was a tendency in the transapical transcatheter aortic valve implantation group toward a less favorable survival outcome, although there was no significant difference among the 3 groups.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Periférico/métodos , Artéria Femoral , Implante de Prótese de Valva Cardíaca/métodos , Esternotomia/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Bases de Dados Factuais , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Pontuação de Propensão , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Esternotomia/efeitos adversos , Esternotomia/mortalidade , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
15.
J Am Coll Cardiol ; 71(14): 1513-1524, 2018 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-29622157

RESUMO

BACKGROUND: Delayed coronary obstruction (DCO) is an uncommon and barely reported complication following transcatheter aortic valve replacement (TAVR). OBJECTIVES: The aim of this study was to describe the incidence and pathophysiological features of DCO after TAVR, obtained from a large international multicenter registry. METHODS: Data were retrospectively collected from an international multicenter registry consisting of 18 centers between November 2005 and December 2016. RESULTS: During the study period, 38 DCO (incidence 0.22%) cases were identified from a total of 17,092 TAVR procedures. DCO occurred more commonly after valve-in-valve procedures (0.89% vs. 0.18%; p < 0.001) and if self-expandable valves were used during the index procedure (0.36% vs. 0.11% balloon expandable; p < 0.01). DCO was most likely to occur ≤24 h after the TAVR procedure (47.4%; n = 18); 6 (15.8%) cases occurred between 24 h and ≤7 days, with the remaining 14 (36.8%) at ≥60 days. The most frequent presentation was cardiac arrest (31.6%; n = 12), followed by ST-segment elevation myocardial infarction (23.7%; n = 9). The left coronary artery was obstructed in most cases (92.1%; n = 35). Percutaneous coronary intervention was attempted in the majority of cases (74.3% left main; 60% right coronary), and stent implantation was successful in 68.8%. The overall in-hospital death rate was 50% (n = 19), and was higher if DCO occurred ≤7 days from the index procedure (62.5% vs. 28.6%; p = 0.09). CONCLUSIONS: DCO following TAVR is a rare phenomenon that is associated with a high in-hospital mortality rate. Clinicians should be aware that coronary obstruction can occur after the original TAVR procedure and have a low threshold for performing coronary angiography when clinically suspected.


Assuntos
Oclusão Coronária/etiologia , Complicações Pós-Operatórias , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Angiografia Coronária , Oclusão Coronária/diagnóstico , Oclusão Coronária/epidemiologia , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Oriente Médio/epidemiologia , América do Norte/epidemiologia , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X
16.
J Interv Cardiol ; 31(3): 384-390, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29490430

RESUMO

OBJECTIVES: We present our single center experience with Medtronic CoreValve and Evolut R regarding procedural outcome and 3 years follow-up in patients with degenerated bioprostheses. METHODS: From 1645 patients who underwent transfemoral TAVI at our institution between February 2009 and December 2016, 37 patients with degenerated bioprosthesis were treated with Medtronic CoreValve/Evolut R. All data concerning baseline characteristic, procedural outcomes and follow-up were entered into a dedicated database. RESULTS: Mean age was 83.9 ± 4.4 years and patients showed an average logistic EuroSCORE of 33.2 ± 16.7%. Successful ViV deployment was achieved in all cases, a permanent pacemaker was implanted in 16.2%, no periinterventional stroke and no coronary obstruction occurred. Mortality at 30 days was 2.7%, at 1-year follow-up 5.7% and at three years 13.5%. Depending on bioprosthesis size <23 mm versus ≥23 mm echocardiographic mean gradients post implantation were significantly higher in the smaller bioprostheses, 22.8 mmHg ± 9.4 mmHg versus 15.1 ± 7.1, P = 0.013. CONCLUSION: ViV-TAVI with CoreValve/R is demonstrated to be safe and effective in terms of no coronary obstruction and very low mortality up to 3 years despite slightly higher mean transprosthetic gradients especially in very small bioprostheses.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estudos de Coortes , Ecocardiografia , Feminino , Fluoroscopia , Humanos , Masculino , Marca-Passo Artificial , Resultado do Tratamento
17.
Clin Res Cardiol ; 107(6): 479-486, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29453593

RESUMO

BACKGROUND AND STUDY OBJECTIVE: Different studies have shown a good long-term survival with improvement of symptoms and hemodynamics after percutaneous septal ablation (PTSMA), similar to myectomy considered to be the therapeutic "gold standard" for symptomatic hypertrophic obstructive cardiomyopathy (HOCM). Furthermore, desobliteration of left ventricular (LV) outflow may modify features of the disease considered to be risk-relevant, such as magnitude of LV hypertrophy, outflow gradient, and left atrial (LA) size. The aim oft this study was to examine predictors of long-term mortality in a large cohort of patients with HOCM treated with PTSMA. METHODS AND RESULTS: 497 consecutive patients with symptomatic HOCM (mean age 55.4 ± 14.4 years, NYHA class: 2.9 ± 0.4) who underwent PTSMA between 1996 and 2014 were studied. Periprocedural mortality was 1% (five patients). During a follow-up time of 64.5 ± 53.2 months (range 0.1-207), 51 patients died, of these 25 due to cardiovascular problems, while 26 deaths were attributed to non-cardiac causes. Overall survival rates were 89.4% (± 1.7) after 5 and 80.6% (± 2.7) after 10 years. Among the baseline variables, advanced age, recurrent syncope, and magnitude of LV thickening were risk markers correlated to long-term post-procedural survival. The only mortality predictor that could be identified during follow-up was post-procedural NYHA class. Neither the other classical HCM risk markers nor other clinical or echocardiographic parameters predicted cardiac or all-cause mortality in this cohort. CONCLUSIONS: Our findings suggest that the risk profile after septal ablation may differ from that of HOCM patients without an outflow desobliteration.


Assuntos
Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter/métodos , Medição de Risco/métodos , Septo Interventricular/cirurgia , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/mortalidade , Ecocardiografia Doppler , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Septo Interventricular/diagnóstico por imagem
18.
Echocardiography ; 35(5): 621-631, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29437242

RESUMO

OBJECTIVES: Although procedure-related new cardiac conduction disturbances (CCDs) remain an important issue in transcatheter aortic valve implantation (TAVI), their effect on myocardial function and overall patient outcome remains unclear. The goal of this study was to analyze the influence of procedure-related CCDs on systolic and diastolic LV performance and on patient survival after TAVI. METHODS AND RESULTS: Ninety-five patients who underwent TAVI for severe symptomatic aortic stenosis (AS) and had a complete follow-up were evaluated with respect to procedure-related CCDs. Left ventricular (LV) performance was measured using standard echocardiographic parameters and speckle tracking analysis. Survival was assessed during longer-term follow-up (mean: 29.1 ± 16.9 months). After TAVI, the improvement of global LV function expressed as ejection fraction (LVEF; from 45.5 ± 10.0 to 47.8 ± 13.9%, P = .13) was not significant. New CCDs were found in 35.7% of TAVI recipients. A comparison between patients with and without new CCDs showed that LV systolic function improved in those without CCDs, while it tended to deteriorate in patients with CCDs (change in LVEF: 5.5 ± 12.3% vs -4.9% ± 11.5%, P = .001; change in global longitudinal strain (GLS): -1.1 ± 4.6% vs 1.2 ± 4.5%, P = .01). Changes in diastolic function did not differ significantly between the groups (changes in transmitral E/A-ratio: -0.3 ± 0.6 vs -0.5 ± 0.5, P = .1). Kaplan-Meier survival analysis revealed no significant differences between the two cohorts (P = .795). CONCLUSION: Procedure-related conduction abnormalities after TAVI lead to an LBBB-related dyssynchrony with impairment of LV performance but not of overall survival.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Ecocardiografia/métodos , Próteses Valvulares Cardíacas , Contração Miocárdica/fisiologia , Substituição da Valva Aórtica Transcateter/métodos , Função Ventricular Esquerda/fisiologia , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Diástole , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Sístole , Resultado do Tratamento
19.
Eur Heart J ; 39(8): 676-684, 2018 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-29253177

RESUMO

Aims: Life-threatening complications occur during transcatheter aortic valve implantation (TAVI) which can require emergent cardiac surgery (ECS). Risks and outcomes of patients needing ECS during or immediately after TAVI are still unclear. Methods and results: Incidence, risk factors, management, and outcomes of patients requiring ECS during transfemoral (TF)-TAVI were analysed from a contemporary real-world multicentre registry. Between 2013 and 2016, 27 760 patients underwent TF-TAVI in 79 centres. Of these, 212 (0.76%) patients required ECS (age 82.4 ± 6.3 years, 67.5% females, logistic EuroSCORE: 17.1%, STS-score 5.8%). The risk of ECS declined from 2013 (1.07%) to 2014 (0.70%) but remained stable since. Annual TF-TAVI numbers have more than doubled from 2013 to 2016. Leading causes for ECS were left ventricular perforation by the guidewire (28.3%) and annular rupture (21.2%). Immediate procedural mortality (<72 h) of TF-TAVI patients requiring ECS was 34.6%. Overall in-hospital mortality was 46.0%, and highest in case of annular rupture (62%). Independent predictors of in-hospital mortality following ECS were age > 85 years [odds ratio (OR) 1.87, 95% confidence interval (95% CI) (1.02-3.45), P = 0.044], annular rupture [OR 1.96, 95% CI (0.94-4.10), P = 0.060], and immediate ECS [OR 3.12, 95% CI (1.07-9.11), P = 0.037]. One year of survival of the 114 patients surviving the in-hospital period was only 40.4%. Conclusion: Between 2014 and 2016, the need for ECS remained stable around 0.7%. Left ventricular guidewire perforation and annular rupture were the most frequent causes, accounting for almost half of ECS cases. Half of the patients could be salvaged by ECS-nevertheless, 1 year of all-cause mortality was high even in those ECS patients surviving the in-hospital period.


Assuntos
Estenose da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Mortalidade Hospitalar/tendências , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Procedimentos Cirúrgicos Cardíacos/tendências , Tratamento de Emergência/tendências , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Masculino , Sistema de Registros , Medição de Risco
20.
Heart Lung Circ ; 27(6): 725-730, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28690021

RESUMO

BACKGROUND: For nonagenarians with symptomatic severe aortic stenosis transcatheter aortic valve implantation (TAVI) has become a feasible therapeutic option. Therefore, the aim of this study was to evaluate the procedural outcomes and mid-term follow-up in this patient group and compare this to octogenarians. METHODS: From 1359 patients who underwent TAVI at our institution between March 2009 and February 2016, 82 patients were nonagenarians and 912 were octogenarians. In nonagenarians, mean age was 91.9±1.4years and compared to octogenarians showed a significantly higher logistic EuroScore (27.7±14.8% vs. 23.1±14.4, p=0.005) and STS Score (8.5±4.8% vs. 6.3±6.7, p=0.001). RESULTS: There were no significant differences with regard to stroke rate, pacemaker implantation rate and major vascular complications between the two groups. Thirty-day mortality was 9.8% in nonagenarians and 4.1% in octogenarians (p=0.04). At 1 year, all-cause mortality increased to 30.9% vs. 18.6% (n.s.). CONCLUSION: Nonagenarians showed an increased periprocedural mortality during TAVI and higher mortality in follow-up compared to octogenarians. Age alone is not a predictive factor but indication for treatment should be carefully evaluated by the heart team on an individual basis.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Fatores Etários , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Angiografia Coronária , Ecocardiografia , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Prognóstico , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA