Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nephron ; 137(3): 205-211, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28817831

RESUMO

BACKGROUND/AIMS: Anticoagulation of the extracorporeal circuit is essential for adequate haemodialysis (HD). Low molecular weight heparins (LMWHs) are safe and sufficient towards achieving this goal. In the Netherlands, dosage is based on bodyweight and adjusted based on clinical events. LMWH levels during dialysis can be quantified through measurement of the anti-Xa activity and a target range of 0.5-1.0 IU/mL has been proposed. We aimed to evaluate the practical value of the anti-Xa activity to guide LMWH dosage in HD patients. Additionally, the value of the activated partial thromboplastin time (APTT) was investigated. METHODS: All prevalent adult HD patients of our dialysis clinic were included. APTT and anti-Xa activity were measured before, during and after 2 dialysis sessions. Clinical and dialysis characteristics, including LMWH dosage, were derived from digital patient charts. RESULTS: Our final study cohort consisted of 83 patients. LMWH dosage during dialysis was appropriate for bodyweight in 61% of cases, of which 50% reached an anti-Xa activity within the putative target range of 0.5-1.0 IU/mL. Forty-six percent of patients had an anti-Xa activity >1.0 IU/mL. Anti-Xa levels during and after dialysis were significantly correlated (r = 0.803, p < 0.01). No thrombotic or haemorrhagic complications were observed in this study. Correlation of APTT with anti-Xa activity was poor. CONCLUSION: Anti-Xa activity measurements during dialysis can identify patients in whom LMWH dosage should be lowered in a subsequent dialysis session. Whether such an intervention leads to a decrease in haemorrhagic complications needs to be evaluated in prospective studies.


Assuntos
Anticoagulantes/uso terapêutico , Inibidores do Fator Xa/farmacologia , Fator Xa/efeitos dos fármacos , Heparina de Baixo Peso Molecular/uso terapêutico , Falência Renal Crônica/terapia , Diálise Renal , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Estudos Transversais , Feminino , Humanos , Falência Renal Crônica/fisiopatologia , Masculino , Pessoa de Meia-Idade , Países Baixos , Tempo de Tromboplastina Parcial
2.
Perit Dial Int ; 23(2): 184-90, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12713087

RESUMO

OBJECTIVE: A reliable assessment of nutritional state in peritoneal dialysis (PD) patients is of great importance. Nevertheless, techniques used to assess body composition in patients on PD may be affected by abnormalities in fluid status. The primary aim of the present study was to compare different techniques used to evaluate body composition and to assess the influence of fluid status on the assessment of body composition. The secondary aim was to assess the relevance of handgrip muscle strength in the nutritional evaluation of the patient. METHODS: In 40 PD patients, dual-energy x-ray absorptiometry (DEXA), multifrequency bioimpedance analysis (MF-BIA), and anthropometry were compared with respect to the evaluation of body composition [fat mass and lean body mass (LBM; by DEXA), and fat-free mass (FFM; by MF-BIA, anthropometry]. The influence of fluid status on the measurement of LBM/FFM by the various techniques was assessed by their relation to left ventricular end-diastolic diameter (LVEDD), assessed by echocardiography, and by estimating the ratio between extracellular water (ECW) and total body water (TBW), assessed by bromide and deuterium dilution, with LBM (DEXA). The relevance of handgrip muscle strength as a nutritional parameter was assessed by its relation to LBM and other nutritional parameters. RESULTS: Despite highly significant correlations, wide limits of agreement between the various techniques were present with respect to assessment of body composition (expressed as % body weight) and were most pronounced for anthropometry: LBM (DEXA) - FFM (MF-BIA) = 3.4% +/- 12.2%; LBM (DEXA) - FFM (anthropometry) = -5.7% +/- 7.8%; fat mass (DEXA - MF-BIA) = -4.2% +/- 7.9%; fat mass (DEXA - anthropometry) = 2.9% +/- 7.2%. The ratio between ECW and LBM (DEXA) was 0.36 +/- 0.08 L/kg (range 0.25 - 0.67 L/kg), and the ratio between TBW and LBM was 0.75 +/- 0.06 L/kg (range 0.63 - 0.86 L/kg), which shows the variability in hydration state of LBM/FFM between individual patients. LBM/FFM measured by all three techniques was significantly related to LVEDD, suggesting an important influence of hydration state on this parameter. Handgrip muscle strength was significantly related to LBM/FFM, as measured by all three techniques, but not to other nutritional parameters. CONCLUSION: Wide limits of agreement were found between various techniques used to assess body composition in PD patients. The assessment of body composition was strongly influenced by hydration state. The handgrip test is related to body composition, but not to other nutritional parameters.


Assuntos
Composição Corporal/fisiologia , Índice de Massa Corporal , Força da Mão/fisiologia , Estado Nutricional/fisiologia , Diálise Peritoneal/efeitos adversos , Insuficiência Renal/fisiopatologia , Insuficiência Renal/terapia , Desequilíbrio Hidroeletrolítico/etiologia , Desequilíbrio Hidroeletrolítico/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
3.
Kidney Int ; 63(4): 1556-63, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12631373

RESUMO

Overhydration is a risk factor for hypertension and left ventricular hypertrophy in peritoneal dialysis patients. Recently, a high prevalence of subclinical overhydration was observed in peritoneal dialysis patients. Aim of the present open-label randomized study was to assess the effect of a icodextrin 7.5% solution on fluid status [extracellular water (ECW) bromide dilution], blood pressure regulation (24-hour ambulatory measurements) and echocardiographic parameters during a study period of 4 months, and to relate the effect to peritoneal membrane characteristics (dialysate/plasma creatinine ratio). Forty peritoneal dialysis patients (22 treated with icodextrin, 18 controls) were randomized to either treatment with icodextrin during the long dwell or standard glucose solutions. Thirty-two patients (19 treated with icodextrin, 13 controls] completed the study. The use of icodextrin resulted in a significant increase in daily ultrafiltration volume (744 +/- 767 mL vs. 1670 +/- 1038 mL; P = 0.012) and a decrease in ECW (17.5 +/- 5.2 L vs. 15.8 +/- 3.8 L; P = 0.035). Also the change in ECW between controls and patients treated with icodextrin was significant (-1.7 +/- 3.3 L vs. +0.9 +/- 2.2 L; P = 0.013). The effect of icodextrin on ECW was not related to peritoneal membrane characteristics, but significantly related to the fluid state of the patients (ECW:height) (r = -0.72; P < 0.0001). Left ventricular mass (LVM) decreased significantly in the icodextrin-treated group (241 +/- 53 grams vs. 228 +/- 42 grams; P = 0.03), but not in the control group. In this randomized open-label study, the use of icodextrin resulted in a significant reduction in ECW and LVM. The effect of icodextrin on ECW was not related to peritoneal membrane characteristics, but was related to the initial fluid state of the patient.


Assuntos
Soluções para Diálise/administração & dosagem , Glucanos/administração & dosagem , Glucose/administração & dosagem , Falência Renal Crônica/terapia , Diálise Peritoneal/métodos , Adulto , Idoso , Pressão Sanguínea , Volume Sanguíneo , Composição Corporal , Peso Corporal , Diurese , Ecocardiografia , Feminino , Taxa de Filtração Glomerular , Humanos , Icodextrina , Masculino , Pessoa de Meia-Idade , Peritônio/metabolismo , Equilíbrio Hidroeletrolítico
4.
Nephrol Dial Transplant ; 18(4): 797-803, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12637651

RESUMO

BACKGROUND: Both peritoneal transport characteristics as well as residual renal function are related to outcome in patients treated with continuous ambulatory peritoneal dialysis (CAPD). It has been suggested that part of this relationship might be explained by an effect of both parameters on the fluid state in CAPD patients or by the relationship between inflammation and peritoneal transport. METHODS: In the present study, the relationship between fluid state [extracellular water (ECW) (sodium bromide); total body water (TBW) (deuterium oxide)] with peritoneal transport characteristics (2.27% glucose dialysate/plasma creatinine [D/P (creat)] ratio), residual renal function (residual glomerular filtration rate [rGFR] by urine collection) and C-reactive protein (CRP) was assessed in 37 CAPD patients in a cross-sectional and longitudinal design, with 25 patients completing the study. RESULTS: In the cross-sectional part ECW, corrected for height (ECW:height), was inversely related to rGFR (r=-0.40, P=0.016), whereas during the longitudinal part, D/P[creat] was related to the change in ECW (r=0.40, P=0.05). Neither D/P[creat] nor rGFR were related to CRP, whereas a significant relationship was observed between ECW:height and CRP (r=0.58, P=0.0001). Patients were dichotomized according to rGFR (<2 or >2 ml/min). Despite a higher daily peritoneal glucose prescription (216.3+/-60.0 vs 156.5+/-53.0 g/24 h; P=0.004) and peritoneal ultrafiltration volume (1856+/-644 vs 658+/-781 ml/24 h, respectively; P=0.0001), the patients with a rGFR <2 ml/min showed a higher ECW:height compared with the group with rGFR >2 ml/min (12.5+/-3.8 vs 9.2+/-2.2 l/m, respectively; P=0.003). Results for TBW were comparable. CONCLUSION: Fluid state was significantly related to peritoneal transport characteristics and rGFR. The larger ECW:height in CAPD patients with a negligible rGFR existed despite a higher peritoneal ultrafiltration volume and higher peritoneal glucose prescription. These findings raise doubts as to whether fluid state in CAPD patients with a diminished rGFR can be adequately controlled on standard glucose solutions without an additional sodium and fluid restriction. The preliminary finding of a relationship between CRP and fluid state might suggest a relationship between overhydration and inflammation.


Assuntos
Soluções para Diálise/farmacocinética , Diálise Peritoneal Ambulatorial Contínua/métodos , Desequilíbrio Hidroeletrolítico/diagnóstico , Transporte Biológico , Água Corporal , Peso Corporal , Estudos Transversais , Feminino , Taxa de Filtração Glomerular , Humanos , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/mortalidade , Falência Renal Crônica/terapia , Testes de Função Renal , Estudos Longitudinais , Masculino , Diálise Peritoneal Ambulatorial Contínua/efeitos adversos , Diálise Peritoneal Ambulatorial Contínua/mortalidade , Permeabilidade , Probabilidade , Prognóstico , Valores de Referência , Medição de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Resultado do Tratamento , Desequilíbrio Hidroeletrolítico/etiologia
5.
Perit Dial Int ; 22(4): 477-87, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12322819

RESUMO

OBJECTIVE: Hypertension, reduced arterial distensibility, and left ventricular hypertrophy (LVH) are risk factors for mortality in hemodialysis patients. However, few studies have focused on the relation between fluid status, blood pressure (BP), and cardiovascular abnormalities in peritoneal dialysis (PD) patients. This study was designed, first, to assess, using tracer dilution techniques, fluid status in PD patients compared to a control population of stable renal transplant (RTx) patients; second, to study the relation between fluid status, BP, and arterial wall abnormalities; third, to assess the determinants of cardiac structure; and last, to compare office and ambulatory BP measurements with respect to cardiac abnormalities. DESIGN: Cross-sectional study. SETTING: Multicenter study. PATIENTS: 41 stable PD patients with a mean Kt/V urea of 2.4 +/- 0.7, and 77 stable RTx patients. INTERVENTION: Fluid status was assessed by tracer dilution techniques: extracellular volume (ECV) with bromide dilution; total body water (TBW) with deuterium oxide; and plasma volume (PV) with dextran 70. Echocardiography was performed to assess left ventricular mass (LVM), left ventricular end diastolic diameter (LVEDD), and relative wall thickness as indicators of LVH. Echography of the common carotid artery was performed to assess arterial distensibility. Both office and 24-hour ambulatory BP measurements were performed. RESULTS: Fluid status, as assessed by ECV corrected for body surface area (BSA) (ECV:BSA), was significantly different between PD and RTx patients (9.4 +/- 2.6 vs 8.6 +/- 1.2 L/m2, p < 0.05). In 36.6% of the PD patients, ECV:BSA was above the 90th percentile of the RTx patients. Fluid status corrected for BSA, assessed by TBW (TBW:BSA), ECV (ECV:BSA), or plasma volume (PV:BSA), was significantly related to diastolic BP (DBP) (r = 0.35, r = 0.37, r = 0.53; p < 0.05). Arterial distensibility of the common carotid artery was related to systolic BP (SBP) (r = -0.36, p < 0.05). ECV was significantly related to LVEDD (r = 0.41, p < 0.05) as a marker of eccentric LVH, whereas arterial distensibility was related to relative wall thickness (r = -0.53, p < 0.001) as a marker of concentric LVH. An abnormal day-night BP rhythm, which was not related to fluid status, was observed in 68.4% of patients. Ambulatory DBP and SBP but not office DBP and SBP were related to LVM (r = 0.43, r = 0.46; p < 0.01). CONCLUSIONS: A large proportion of PD patients whose treatment prescriptions are in accordance with the Dialysis Outcomes Quality Initiative guidelines were found to be overhydrated compared with a population of stable RTx patients. Fluid status was significantly related to DBP and eccentric LVH, whereas arterial distensibility of the common carotid artery was significantly related to SBP and concentric LVH. In contrast to ambulatory BP, office BP was not related to LVM.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/etiologia , Endotélio Vascular/diagnóstico por imagem , Hipertensão/diagnóstico por imagem , Hipertensão/etiologia , Falência Renal Crônica/diagnóstico por imagem , Falência Renal Crônica/terapia , Diálise Peritoneal/efeitos adversos , Desequilíbrio Hidroeletrolítico/diagnóstico por imagem , Desequilíbrio Hidroeletrolítico/etiologia , Adulto , Idoso , Monitorização Ambulatorial da Pressão Arterial , Doenças Cardiovasculares/fisiopatologia , Estudos de Coortes , Estudos Transversais , Ecocardiografia , Endotélio Vascular/fisiopatologia , Feminino , Humanos , Hipertensão/fisiopatologia , Falência Renal Crônica/fisiopatologia , Masculino , Pessoa de Meia-Idade , Desequilíbrio Hidroeletrolítico/fisiopatologia
6.
Perit Dial Int ; 22(6): 683-92, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12556070

RESUMO

OBJECTIVES: To assess the influence of abnormalities in fluid status and body composition on agreement between multifrequency bioimpedance analysis (MF-BIA), segmental BIA (sigmaBIA), the Watson formula, and tracer dilution techniques. DESIGN: Cross-sectional. SETTING: Multicenter. PATIENTS: 40 patients (29 males, 11 females) on peritoneal dialysis (PD). MAIN OUTCOME MEASURES: Agreement between the various techniques used to assess total body water (TBW) [MF-BIA, deuterium oxide (D2O), and the Watson formula] and extracellular water (ECW) [MF-BIA, bromide dilution (NaBr), and sigmaBIA], also in relation to the relative magnitude of the body water compartments [ECW (NaBr):body weight (BW) and TBW (D2O):BW] and body composition (DEXA). Second, the relation between body water compartments with echocardiographic parameters. RESULTS: Wide limits of agreement were observed between tracer dilution techniques and MF-BIA [TBW (D2O - MF-BIA) 2.0 +/- 3.9 L; ECW (NaBr - MF-BIA) -2.8 +/- 3.9 L], which were related to the relative magnitude of the body water compartments: r = 0.70 for ECW and r = 0.40 for TBW. sigmaBIA did not improve the agreement [ECW (NaBr-sigmaBIA): 3.7 +/- 2.9 L]. Also, wide limits of agreement were observed between D2O and the Watson formula (-2.3 +/- 3.3 L). The difference between D2O and Watson was related to hydration state and to percentage of fat mass (r = 0.70 and r = -0.53, p < 0.05). Both ECW and TBW as assessed by BIA and tracer dilution were related to echocardiographic parameters. CONCLUSION: Wide limits of agreement were found between MF-BIA and sigmaBIA with dilution methods in PD patients, which were related to hydration state itself. The disagreement between the Watson formula and dilution methods was related to both hydration state and body composition.


Assuntos
Composição Corporal/fisiologia , Técnicas de Diluição do Indicador , Diálise Peritoneal/efeitos adversos , Insuficiência Renal/terapia , Desequilíbrio Hidroeletrolítico/etiologia , Desequilíbrio Hidroeletrolítico/fisiopatologia , Adulto , Idoso , Compartimentos de Líquidos Corporais/fisiologia , Água Corporal/fisiologia , Estudos Transversais , Impedância Elétrica , Espaço Extracelular/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA