Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Eur Heart J Case Rep ; 6(9): ytac385, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36168592

RESUMO

Background: The prevalence of cement embolism after percutaneous vertebroplasty ranges from 2.1 to 26%, in literature. Even if most cases remain asymptomatic, intracardiac cement embolism becomes symptomatic in up to 8.3% of the cases. Case summary: We report a case series of two cases with massive cardiopulmonary cement embolism, which lead to perforation of the right ventricle and needed cardiothoracic surgery. Discussion: As this entity affects different fields of medical specialties and may lead to fatal outcome, we believe that the efforts of better understanding its development, avoidance, detection, and treatment need to be intensified. For this purpose, systematic and interdisciplinary studies to follow up patients after vertebroplasty are needed.

2.
J Clin Med ; 11(8)2022 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-35456350

RESUMO

BACKGROUND: The impact of transcatheter heart valve (THV) position on the occurrence of paravalvular leakage and permanent pacemaker implantation caused by new-onset conduction disturbances is well described. The purpose of this study was to investigate the influence of the geometry of the thoracic aorta on the implantation depth after TAVI (transcatheter heart valve implantation) using self-expanding valve (SEV) types. METHODS: We evaluated three-dimensional geometry of the thoracic aorta based on computed tomography angiography (CTA) in 104 subsequently patients receiving TAVI with SEV devices (Evolut R). Prosthesis position was determined using the fusion imaging method of pre- and post-procedural CTA. An implantation depth of ≥4 mm was defined as the cut-off value for low prosthesis position. RESULTS: The mean implantation depth of the THV in the whole cohort was 4.3 ± 3.0 mm below annulus plane. THV position was low in 66 (63.5%) patients and high in 38 (36.5%) patients. After multivariate adjustment none of the aortic geometry characteristics showed an independent influence on the prosthesis position-neither the Sinus of Valsalva area (p = 0.335) nor the proximal aortic arch diameter (p = 0.754) or the distance from annulus to descending aorta (p = 0.309). CONCLUSION: The geometry of the thoracic aorta showed no influence on the positioning of self-expanding TAVI valve types.

3.
Front Cardiovasc Med ; 9: 791949, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35310972

RESUMO

Leaflet durability and costs restrict contemporary trans-catheter aortic valve replacement (TAVR) largely to elderly patients in affluent countries. TAVR that are easily deployable, avoid secondary procedures and are also suitable for younger patients and non-calcific aortic regurgitation (AR) would significantly expand their global reach. Recognizing the reduced need for post-implantation pacemakers in balloon-expandable (BE) TAVR and the recent advances with potentially superior leaflet materials, a trans-catheter BE-system was developed that allows tactile, non-occlusive deployment without rapid pacing, direct attachment of both bioprosthetic and polymer leaflets onto a shape-stabilized scallop and anchorage achieved by plastic deformation even in the absence of calcification. Three sizes were developed from nickel-cobalt-chromium MP35N alloy tubes: Small/23 mm, Medium/26 mm and Large/29 mm. Crimp-diameters of valves with both bioprosthetic (sandwich-crosslinked decellularized pericardium) and polymer leaflets (triblock polyurethane combining siloxane and carbonate segments) match those of modern clinically used BE TAVR. Balloon expansion favors the wing-structures of the stent thereby creating supra-annular anchors whose diameter exceeds the outer diameter at the waist level by a quarter. In the pulse duplicator, polymer and bioprosthetic TAVR showed equivalent fluid dynamics with excellent EOA, pressure gradients and regurgitation volumes. Post-deployment fatigue resistance surpassed ISO requirements. The radial force of the helical deployment balloon at different filling pressures resulted in a fully developed anchorage profile of the valves from two thirds of their maximum deployment diameter onwards. By combining a unique balloon-expandable TAVR system that also caters for non-calcific AR with polymer leaflets, a powerful, potentially disruptive technology for heart valve disease has been incorporated into a TAVR that addresses global needs. While fulfilling key prerequisites for expanding the scope of TAVR to the vast number of patients of low- to middle income countries living with rheumatic heart disease the system may eventually also bring hope to patients of high-income countries presently excluded from TAVR for being too young.

4.
Interact Cardiovasc Thorac Surg ; 34(5): 865-871, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-35092274

RESUMO

OBJECTIVES: This study aimed to analyse risk factors for postoperative stroke, evaluate the underlying mechanisms and report on outcomes of patients suffering a postoperative stroke after total aortic arch replacement using the frozen elephant trunk technique. METHODS: Two-hundred and fifty patients underwent total aortic arch replacement via the frozen elephant trunk technique between March 2013 and November 2020 for acute and chronic aortic pathologies. Postoperative strokes were evaluated interdisciplinarily by a cardiac surgeon, neurologist and radiologist, and subclassified to each's cerebral territory. We conducted a logistic regression analysis to identify any predictors for postoperative stroke. RESULTS: Overall in-hospital was mortality 10% (25 patients, 11 with a stroke). A symptomatic postoperative stroke occurred in 42 (16.8%) of our cohort. Eight thereof were non-disabling (3.3%), whereas 34 (13.6%) were disabling strokes. The most frequently affected region was the arteria cerebri media. Embolism was the primary underlying mechanism (n = 31; 73.8%). Mortality in patients with postoperative stroke was 26.2%. Logistic regression analysis revealed age over 75 (odds ratio = 3.25; 95% confidence interval 1.20-8.82; P = 0.021), a bovine arch (odds ratio = 4.96; 95% confidence interval 1.28-19.28; P = 0.021) and an acute preoperative neurological deficit (odds ratio = 19.82; 95% confidence interval 1.09-360.84; P = 0.044) as predictors for postoperative stroke. CONCLUSIONS: Stroke after total aortic arch replacement using the frozen elephant trunk technique remains problematic, and most lesions are of embolic origin. Refined organ protection strategies, and sophisticated monitoring are mandatory to reduce the incidence of postoperative stroke, particularly in older patients presenting an acute preoperative neurological deficit or bovine arch.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Acidente Vascular Cerebral , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Humanos , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
6.
Int J Cardiol Heart Vasc ; 36: 100862, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34504944

RESUMO

BACKGROUND: A transapical (TA) approach to transcatheter aortic valve replacement (TAVR) may be used when a transfemoral (TF) approach is not feasible. The CHANGE neo TA study evaluated patients treated in routine clinical practice via TA-TAVR with the ACURATE neo bioprosthetic aortic valve. METHODS AND RESULTS: This single-arm post-market study had a planned enrolment of 200 subjects; enrolment was terminated early due to declining TA-TAVR procedures at participating centers. Final enrolment was 107 patients (mean age: 79.3 years; 54.2% female; mean STS score at baseline: 6.2%). The mortality rate in the intent-to-treat population was 11.2% at 30 days (primary endpoint) and 25.6% at 12 months. The VARC-2 composite endpoint for 30-day safety occurred in 24.3% of patients. Six patients (5.6%) received a permanent pacemaker within 30 days. Site-reported echocardiographic data showed early improvements in mean aortic valve gradient (baseline: 38.8 [SD 13.1] mmHg, discharge: 6.7 [SD 3.7] mmHg) and effective orifice area (baseline: 0.7 [SD 0.2] cm2, discharge: 1.9 [SD 0.6] cm2), and the discharge rate of paravalvular regurgitation was low (74.7% none/trace, 24.2% mild, 1.1% severe). CONCLUSIONS: TA-TAVR with the ACURATE neo valve system yields acceptable clinical outcomes, providing an alternative for patients with aortic stenosis who are not candidates for TF-TAVR.

7.
Int J Cardiovasc Imaging ; 37(10): 3081-3092, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33988801

RESUMO

Prior studies in patients with transcatheter aortic valve implantation (TAVI) demonstrated an influence of transcatheter heart valve (THV) position on the occurrence of new conductions disturbances (CD) and paravalvular leakage (PVL) post TAVI in balloon-expandable valves (BEV). Purpose of this study was to investigate the THV implantation depth and its influence on the occurrence of CD and PVL in self-expanding valves (SEV). We performed fusion imaging of pre- and post-procedural computed tomography angiography in 104 TAVI-patients (all with Evolut R) to receive a 3-D reconstruction of the THV within the native annulus region. The THV length below the native annulus was measured for assessment of implantation depth. Electrocardiograms pre-discharge were assessed for conduction disturbances (CD), PVL was determined in transthoracic echocardiography. The mean implantation depth of the THV in the whole cohort was 4.3 ± 3.0 mm. Using the best cut-off of ≥ 4 mm in receiver operating characteristic curve analysis (sensitivity 83.3%, specificity 60.0%) patients with lower THV position developed more new CD after TAVI (68.2 vs. 23.7%, P < 0.001). A deep THV position was identified as the only predictor for new CD after TAVI (odds ratio [CI] 1.312[1.119-1.539], P = 0.001). The implantation depth showed no influence on the grade of PVL (r = 0.052, P = 0.598). In patients with TAVI using the Evolut R SEV, a lower THV positioning (≥ 4 mm length below annulus) was a predictor for new conduction disturbances. In contrast, implantation depth was not associated with the extent of PVL. Prostheses positions of self-expanding valves and their influence on the occurrence of new conduction disturbances and the grade of paravalvular leakage after TAVI.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Clin Res Cardiol ; 110(1): 93-101, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32399896

RESUMO

BACKGROUND: Low prosthesis position after transcatheter aortic valve implantation (TAVI) is associated with higher rates of new onset conduction disturbances and permanent pacemaker implantations. Purpose of this study was to investigate possible predictors of a low prosthesis position of the SAPIEN 3 (Edwards Lifesciences, Irvine, California, USA) valve type using fusion imaging of pre- and post-procedural computed tomography angiography (CTA). METHODS: CTA fusion imaging was performed in 120 TAVI-patients with 3D-reconstruction of the transcatheter heart valve (THV) position within the device landing zone. A low implantation position was defined according to the manufacturer's recommendations as > 30% of the prosthesis below the native annulus plane. RESULTS: A low THV position was found in 17 patients (14%). Patients with low THV position had less calcification of the annulus region and a smaller annulus size compared to patients with a normal or high THV position (P = 0.003 and 0.041, respectively). The only independent predictor of a low THV position in multivariate logistic regression analysis was the extent of calcification of the cusp region (odds ratio [CI] 0.842 [0.727-0.976], P = 0.022). CONCLUSIONS: Fusion imaging of pre-and post-procedural CTA identified reduced calcification of the cusp region as an independent predictor of a low THV position of the SAPIEN 3. This should be considered when planning the TAVI procedure. Correlation of cusp region calcification and prosthesis position after TAVI.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Cirurgia Assistida por Computador/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Período Pós-Operatório , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos
9.
Eur J Cardiothorac Surg ; 59(1): 130-136, 2021 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-33038224

RESUMO

OBJECTIVES: The goal of this study was to evaluate outcomes of aortic arch replacement using the frozen elephant trunk (FET) technique after previous proximal and/or distal open or endovascular thoracic aortic repair. METHODS: Sixty-three patients [median age: 63 (55-74) years; 65% men] were operated on for acute or chronic aortic dissection after previous proximal and/or distal open or endovascular thoracic aortic repair. Intraoperative details, clinical outcome and follow-up results were evaluated. RESULTS: The median time between the index and the FET procedure was 81 (40-113) months. Fifty-eight (92%) patients had already undergone proximal aortic surgery; supracoronary ascending aortic replacement was the most frequent index procedure [n = 25 (40%)]. Distal aortic interventions had been done in 8 (13%) patients including endovascular thoracic aortic repair in 6 patients (10%). In-hospital mortality was 3% (n = 2). Postoperative strokes occurred in 5 patients (8%); of those, 1 stroke was dissection-related (2%). Subsequent aortic reinterventions after the FET procedure had to be done in 33% (n = 21). CONCLUSIONS: Outcomes of aortic arch replacement using the FET technique after previous proximal and/or distal open or endovascular thoracic aortic repair are associated with low mortality and morbidity. Still, postoperative stroke remains an issue. After the successful accomplishments, the approach serves as an ideal platform for the secondary surgical or endovascular downstream aortic procedures, which are frequently needed.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
10.
Eur Heart J Cardiovasc Imaging ; 21(10): 1082-1089, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32588038

RESUMO

AIMS: Early leaflet thrombosis (LT) is a well-described phenomenon after transcatheter aortic valve implantation (TAVI) with an incidence around 15%. Data about predictors of LT are scarce. The purpose of the study was to investigate the influence of prosthesis-related factors on the occurrence of LT. MATERIALS AND RESULTS: Fusion imaging of pre- and post-procedural computed tomography angiography was performed in 55 TAVI patients with LT and 140 selected patients as control groups (85 patients in an unmatched and 55 in a matched control) to obtain a 3D reconstruction of the transcatheter heart valve (THV) within the native annulus region. All patients received a balloon-expandable Sapien 3 THV. The THV length above and below the native annulus was measured within the fused images to assess the implantation depth. The deployed THV area was quantified on three heights (left ventricular outflow tract end, stent centre, and aortic end) to determine the average expansion of the prosthesis as percent of the nominal area. We also calculated the extent of prosthesis waist in percent of maximum area. After multivariate adjustment, the extent of THV waist [odds ratio (OR) per 10% (confidence interval, CI) 0.636 (0.526-0.769), P < 0.001] as prosthesis-related factor and previous oral anticoagulation [OR (CI) 0.070 (0.020-0.251), P < 0.001] had significant, independent influence on the occurrence of LT. The implantation depth showed no influence on LT manifestation (P = 0.704). CONCLUSION: Besides the absence of previous oral anticoagulation, a less pronounced waist of the implanted THV was a prosthesis-position-related independent predictor of LT after TAVI using the Sapien 3.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Desenho de Prótese , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
PLoS One ; 15(2): e0227345, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32023258

RESUMO

AIMS: Patients with postoperative delirium (POD) after transcatheter aortic valve replacement (TAVR) are ventilated and hospitalized longer and suffer increased in-hospital mortality. This study hypothesized that a minimalistic approach with conscious sedation during transfemoral aortic valve replacement (TF-AVR) protects against delirium, time of mechanical ventilation, and increased length of stay in intensive care unit (ICU) compared to intubation anaesthesia. METHODS AND RESULTS: 308 patients which underwent TF-AVR in our centre between 01/2013 and 08/2017 were retrospectively evaluated regarding postoperative delirium, time of mechanical ventilation, and days in ICU. TF-AVR was performed with intubation anaesthesia in 245 patients and with conscious sedation in 63. The operative risk estimated by the logEUROScore was similar in both groups (intubation: 13.28 +/-9.06%, conscious sedation: 12.24 +/-6.77%, p = 0.395). In the conscious sedation group procedure duration was shorter (0.61 +/-0.91h vs. 1.75 +/-0.96h, p<0.001). The risk for intraprocedural complications was not influenced by the anaesthesia method (OR conscious sedation instead of intubation 1.66, p = 0.117), but days on ICU (-2.21 days, p<0.0001) and minutes of mechanical ventilation (-531.2 min, p < 0.0001) were reduced. Furthermore, the risk of POD was decreased when TF-AVR was performed under conscious sedation (6.35% vs. 18.18%, OR 0.29, p = 0.021). CONCLUSIONS: Time of mechanical ventilation, risk of POD, and days on ICU were substantially reduced in patients who underwent TF-AVR under conscious sedation. Our data suggest that TF-AVR with conscious sedation is safe with a beneficial postoperative course in clinical practice, and should be considered the favoured approach.


Assuntos
Anestesia , Artéria Femoral/cirurgia , Intubação , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Sedação Consciente , Feminino , Humanos , Unidades de Terapia Intensiva , Modelos Logísticos , Masculino , Marca-Passo Artificial , Complicações Pós-Operatórias/etiologia , Respiração Artificial , Fatores de Risco
12.
Interact Cardiovasc Thorac Surg ; 29(6): 944-949, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31504551

RESUMO

OBJECTIVES: Our goal was to report our results of late surgical conversion after endovascular aneurysm repair (EVAR). METHODS: Variables analysed included baseline data, preinterventional anatomy, type of endovascular intervention, indications for conversion, operative technique, postoperative complications and follow-up survival rate. RESULTS: Between April 2011 and May 2018, 16 patients with late complications after EVAR underwent open surgical conversion at our institution. The mean age was 73.6 [standard deviation (SD) 8.9] years. There were 3 (18.8%) female patients. In 15 patients, the indication for primary EVAR was abdominal aortic aneurysm, and in 1 patient, chronic abdominal aortic dissection. Five patients underwent secondary EVAR service interventions for endoleak treatment between the index EVAR and the final secondary surgical conversion. Thirteen patients underwent surgery in an elective setting and 3 patients underwent emergency surgery. The mean time from EVAR to open surgical conversion was 6.31 (SD 4.0) years (range 1.2-16.0 years). The most common indication for conversion was endoleak formation (n = 12, 75%), followed by 3 cases of aortic rupture (1 patient with primary type 1 endoleak) and 2 cases of stent graft infection-1 with and 1 without an aortoduodenal fistula. One patient died during emergency open surgery of cardiopulmonary instability. Three patients developed postoperative renal dysfunction with recovery of their renal function before discharge. The in-hospital mortality rate was 12.5%. The median follow-up was 16.5 months (interquartile range 21 months). Freedom from death and aortic reintervention was 100%, respectively. After careful review of the index computed tomography scans for EVAR, the majority of failures could have been anticipated due to trade-offs with regard to length, diameter, morphology, shape and angulation of the proximal and/or distal landing zone. CONCLUSIONS: Despite being a challenging operation, late surgical conversion after EVAR yields excellent results with regard to outcome and freedom from the need for further aortic interventions. An anticipative strategy adhering to current recommendations for using or refraining from using EVAR in patients with anatomical challenges will help reduce the need for secondary surgical conversions and keep them to minimum.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Conversão para Cirurgia Aberta/métodos , Procedimentos Endovasculares/métodos , Complicações Pós-Operatórias/mortalidade , Idoso , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/mortalidade , Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/mortalidade , Feminino , Alemanha/epidemiologia , Mortalidade Hospitalar/tendências , Humanos , Masculino , Resultado do Tratamento
13.
BMC Cardiovasc Disord ; 19(1): 172, 2019 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-31324150

RESUMO

BACKGROUND: To evaluate the outcomes of transcatheter aortic valve implantation (TAVI) without balloon aortic valvuloplasty (BAV) in a real-world setting through a patient-level meta-analysis. METHODS: The meta-analysis included patients of three European multicenter, prospective, observational registry studies that compared outcomes after Edwards SAPIEN 3 or XT TAVI with (n = 339) or without (n = 355) BAV. Unadjusted and adjusted pooled odds ratios (with 95% confidence intervals) were calculated for procedural and 30-day outcomes. RESULTS: Median procedural time was shorter in the non-BAV group than in the BAV group (73 versus 93 min, p = 0.001), as was median fluoroscopy time (7 versus 11 min, p = 0.001). Post-delivery balloon dilation (15.5% versus 22.4%, p = 0.02) and catecholamine use (9.0% vs. 17.9%; p = 0.016) was required less often in the non-BAV group than in the BAV group with the difference becoming insignificant after multiple adjustment. There was a reduced risk for periprocedural atrioventricular block during the intervention (1.4% versus 4.1%, p = 0.035) which was non-significant after adjustment. The rate of moderate/severe paravalvular regurgitation post-TAVI was 0.6% in the no-BAV group versus 2.7% in the BAV group. There were no between-group differences in the risk of death, stroke or other adverse clinical outcomes at day 30. CONCLUSIONS: This patient-level meta-analysis of real-world data indicates that TAVI performed without BAV is advantageous as it has an adequate device success rate, reduced procedure time and no adverse effects on short-term clinical outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Europa (Continente) , Feminino , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Masculino , Estudos Multicêntricos como Assunto , Estudos Observacionais como Assunto , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
14.
J Thorac Cardiovasc Surg ; 157(1): 26-34.e1, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30041928

RESUMO

OBJECTIVE: The study objective was to screen patients with acute type A aortic dissection for anatomic feasibility of ascending aortic endovascular treatment with a valve-carrying conduit. METHODS: High-quality computed tomography scans of 167 patients were available for screening. Aortic dimensions were measured using multiplanar reconstruction in the plane perpendicular to the manually corrected aortic center line. The simulated stent-graft 10-mm-long landing zones were measured starting at the sinotubular junction (proximal landing zone) and ending at the brachiocephalic trunk (distal landing zone). Exclusion criterion was an entry within the aortic root or the landing zone. RESULTS: In 113 patients (68%), the entry was in a coverable zone in the ascending aorta with sufficient proximal and distal landing zone or in more distal aortic segments. In these patients, the median distance between the proximal and distal landing zone was 89.1 (first quartile: 80.0 mm; third quartile: 101.2 mm) and the median diameter difference was 5.0 mm (2.0; 10.1) (12.3 [4.9; 23.0] %). The diameter difference was less than 2 mm in 32 patients (28%), between 6 mm and 10 mm in 20 patients (18%), between 10 mm and 14 mm in 11 patients (10%), and 14 mm or greater in 10 patients (9%). CONCLUSIONS: Two thirds of all patients who present with type A dissections are potential candidates for treatment with endovascular valve-carrying conduits, but most patients would require tapered stent-grafts.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Prótese Vascular , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/patologia , Aorta/diagnóstico por imagem , Aorta/patologia , Aorta/cirurgia , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/patologia , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/métodos , Humanos , Estudos Retrospectivos , Stents
15.
Am J Cardiol ; 123(2): 315-322, 2019 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-30424871

RESUMO

End-stage renal disease (ESRD) affects approximately 2% to 4% of patients with severe aortic stenosis. It is because these patients have been excluded from clinical trials, the impact of transcatheter aortic valve implantation (TAVI) in this patient group has not been thoroughly investigated. Between April 2008 and March 2015, 2,000 patients (dialysis group, n = 56 [2.8%]) were consecutively enrolled when diagnosed with severe aortic stenosis and eligible to undergo TAVI. Procedural and longer-term outcomes were analyzed and adjusted for differences in baseline characteristics. Patients on dialysis had a higher periprocedural mortality (10.7% vs 1.7%; adjusted odds ratio [adjOR] 5.65, 95% confidence interval [CI] 1.91 to 16.67; p = 0.002) and a lower Valve Academic Research Consortium (VARC)-II (VARC) defined device success (adjOR 0.34, 95% CI 0.15 to 0.79; p = 0.012). At 30 days, there was an increased rate of all-cause mortality (21.4 vs 4.8%; adjOR 4.90, 95% CI 1.96 to 12.26; p = 0.001), cardiovascular (adjOR 3.67, 95% CI 1.43 to 9.41; p = 0.007) and noncardiovascular mortality (adjOR 6.28, 95% CI 1.36 to 9.41; p = 0.019), myocardial infarction (adjOR 9.39, 95% CI 1.84 to 48.03; p = 0.007), bleeding (adjOR 2.48, 95% CI 1.06 to 5.83; p = 0.036) as well as the VARC-II defined early safety combined end point (adjOR 2.97, 95% CI 1.28 to 6.90; p = 0.012) associated with dialysis. Dialysis was associated with poor survival at one (57.1% vs 84.2%) and 3 years (26.8% vs 66.9%) with or without the consideration of the first 72 hours (p <0.001; adjusted p <0.001). Although, in the multivariable regression analysis, reduced ejection fraction, peripheral arterial disease, pulmonary hypertension (PH), frailty and dialysis were associated with 1-year mortality, only PH (>60 mm Hg) remained significant in an analysis restricted to the dialysis patients (adjusted hazard ratio 2.68; 95% CI 1.18 to 5.88; p = 0.018). PH had a sensitivity of 45.8%, a specificity of 81.3%, and a positive predictive value of 64.7%. In conclusion, dialysis is an independent predictor of mortality in patients who underwent TAVI. Long-term mortality in dialysis patients appears to be largely determined by the kidney disease and/or dialysis itself whereas VARC-II defined complications are largely unaffected. An increased short-term mortality still calls for (pre-) procedural optimization.


Assuntos
Estenose da Valva Aórtica/cirurgia , Falência Renal Crônica/imunologia , Diálise Renal/mortalidade , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Feminino , Alemanha/epidemiologia , Humanos , Hipertensão Pulmonar/mortalidade , Falência Renal Crônica/mortalidade , Falência Renal Crônica/terapia , Masculino , Infarto do Miocárdio/epidemiologia , Hemorragia Pós-Operatória/epidemiologia , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros , Sensibilidade e Especificidade
16.
Interact Cardiovasc Thorac Surg ; 28(5): 797-802, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30590614

RESUMO

OBJECTIVES: To minimize the complications with thoracic endovascular aortic repair (TEVAR), a new stent graft with no bare ends was developed, namely the Relay non-bare stent (NBS). We hypothesized that the new features of the NBS graft would enable highly accurate deployment and fewer complications. The aim of this study was to analyse the quality of the Relay NBS with respect to its landing precision. METHODS: Relying on computed tomography angiographs, we evaluated the distance between the stent graft and the target vessel in the proximal landing zone (before and after the intervention as well as the mid-term results). Seventy-eight patients with thoracic aortic pathologies were included. Median computed tomography angiograph follow-up was 16 months. RESULTS: The stent graft was deployable ≤5 mm from the target vessel in 64 (82%) patients; in 14 (18%) of them, the distance to the target vessel was >5 mm. According to the last follow-up computed tomography angiograph, in 35 (55%) patients, the distance to the target vessel was ≤5 mm and in 29 (45%) patients, it was >5 mm. There was no endoleak type Ia immediately after TEVAR or during the follow-up period. A substantial bird beak phenomenon was observed in 3 (4%) and 7 (11%) patients immediately after TEVAR and during the follow-up period, respectively. One patient had a retrograde dissection type A. CONCLUSIONS: The Relay NBS graft can be deployed accurately in the aortic arch in most patients. Retrograde aortic dissection type A seldom occurs after TEVAR using the Relay NBS graft. The distance between the NBS graft and the intended target vessel increases during the follow-up period.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Prótese Vascular , Procedimentos Endovasculares/métodos , Stents , Idoso , Dissecção Aórtica/diagnóstico , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Resultado do Tratamento
17.
Indian J Thorac Cardiovasc Surg ; 35(Suppl 2): 164-168, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33061081

RESUMO

The last 15 years have overwhelmed the surgical community with a range of approaches in treating pathologies involving the aortic arch of which some are here to stay. The ones to stay are-in the authors' opinion-refined classical surgical approaches such as the frozen elephant trunk technique, near-orthotopic combined vascular and endovascular approaches such as subclavian to carotid transposition/bypass and double transposition, and finally, near-orthotopic advanced endovascular solutions such as the double-endovascular repair using fenestrated and/or branched solutions which will be the main focus of this article.

18.
BMJ Open ; 8(10): e022574, 2018 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-30366914

RESUMO

OBJECTIVES: Use of transcatheter aortic valve implantation (TAVI) to treat severe aortic stenosis (AS) has gained popularity, accompanied by an evolution of patient and clinical factors. We aimed to characterise changes and evaluate their impact on outcomes. SETTING: In this single-centre, German TAVIK registry patients undergoing TAVI between 2008 and 2015 were documented prospectively. PARTICIPANTS/INTERVENTIONS: 2000 consecutive patients with AS undergoing TAVI were divided in four cohorts. 500 patients underwent TAVI in each of the following time bins: April 2008 to July 2010 (cohort I), July 2010 to April 2013 (cohort II), April 2012 to October 2013 (cohort III) and October 2013 to March 2015 (cohort IV). RESULTS: The mean age was 81.8 years, without significant variation across cohorts. Compared with cohort I, prior MI (5.4%vs11.0%; p<0.001) and New York Heart Association class IV (10.0%vs3.6%; p<0.001) were less common in cohort IV. Across cohorts, there was a fall in EuroSCORE (24.3%-18.7%), frailty (48.4%-17.0%) and use of transapical access (43.6%-29.0%), while transfemoral access increased (56.4%-71.0%; p<0.001 for each). Periprocedurally, there was a fall in moderate/severe aortic regurgitation (3.2%-0.0%) and rate of unplanned cardiopulmonary bypass (4.0%-1.0%; both p<0.001). A similar trend applied to 30-day rate of major vascular complications (5.2%-1.8%; p=0.006), life-threatening bleeding (7.0%-3.0%; p<0.001) and cardiovascular mortality (4.4%-1.8%; p=0.020). One-year post-TAVI, mortality and stroke rates did not differ. CONCLUSIONS: Evolution of TAVI between 2008 and 2015 saw a trend towards its usage in lower risk patients and rapid progression towards improved safety. Evaluation and refinement should now continue to further lessen stroke and pacemaker rates.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Intervenção Coronária Percutânea , Complicações Pós-Operatórias/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Feminino , Próteses Valvulares Cardíacas , Hospitais Municipais , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/fisiopatologia , Estudos Prospectivos , Fatores de Risco , Análise de Sobrevida , Resultado do Tratamento
19.
Am J Cardiol ; 122(1): 149-155, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-29861048

RESUMO

We aimed to compare the outcomes of transcatheter aortic valve implantation (TAVI) with surgical aortic valve replacement (SAVR) in an elderly but nonfrail, minimally co-morbid population. Although data comparing these 2 procedures in intermediate- and low-risk patients are mounting, no distinction has been made between co-morbidity and age/gender as driving forces for surgical risk. Patients undergoing isolated TAVI or SAVR between May 2008 and March 2015 were documented. Data for 225 patients (TAVI 132, SAVR 93) aged ≥75 and <86 years and fulfilling minimal-risk criteria were analyzed. Patients who underwent TAVI were older (80.7 vs 77.4 years, p <0.0001) and had a higher mean Society of Thoracic Surgeons score (2.16% vs 1.72%, p <0.0001). Mild prosthetic valve regurgitation (odds ratio [OR] 4.9, 95% confidence interval [CI] 3.34 to 7.20) was more likely after TAVI, as were renal complications (predominantly stage I acute kidney injury; OR 2.86, 95% CI 1.79 to 4.55) and new pacemaker implantation (OR 3.33, 95% CI 1.76 to 6.26) at 30 days; however, life-threatening bleeding (OR 0.58, 95% CI 0.36 to 0.93) and reintervention for bleeding (OR 0.03, 95% CI 0.01 to 0.13) were less likely. Survival was comparable between groups at 30 days (99.2% vs 100%, p = 1.0) and 1 year (96.2% vs 96.8%, OR 0.85, 95% CI 0.20 to 3.63, p = 0.823), but it was poorer for patients who underwent TAVI at 2 years (OR 0.31, 95% CI 0.16 to 0.61). In conclusion, the short-term outcomes of TAVI in elderly, low-risk, minimally co-morbid patients appear to be similar to those of SAVR, with access-specific complications. Although these results point toward the potential for more liberal use of TAVI in minimal-risk patients, poorer midterm survival remains a concern, requiring further exploration.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Estudos Prospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
20.
J Vis Surg ; 4: 69, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29780715

RESUMO

Outcome after classical surgical repair of acute Type A aortic dissection has steadily improved over the years and several modifications in cannulation and perfusion added to this achievement. However, subgroups remain where results of classical surgical repair still have room for improvement, particularly patients with severe preoperative malperfusion as well as elderly patients with a limited physiological reserve. So far, only small case series or case reports have been published on the endovascular treatment of dissected ascending aortas. However, a tube alone is not sufficient to fix the entire complex underlying problem in the vast majority of patients with acute Type A aortic dissection. In addition, these published reports are either due to a favorable anatomy or due to very localized disease processes, which are the exception and not the rule. The concept of an endovascular valve-carrying conduit may significantly increase the number of patients suitable for endovascular therapy and it may soon be common practice.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA