Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
IEEE Open J Eng Med Biol ; 3: 18-24, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35399792

RESUMO

Goal: To enhance endovascular navigation using surgical guidewires and the use of ionizing radiation, we demonstrate a method for ultrasonic localization of wires with diameters less than the wavelength of ultrasound in the medium. Methods: Nitinol wires with diameters ranging from 50 µm to 250 µm were imaged ultrasonically in a 0.25-in-diameter water-filled tube in a gelatin medium. Imaging frequencies were 5 MHz, 7.5 MHZ, and 10 MHz. Results: For the full range of diameters traversing the phantom, the wires were localized successfully via visual inspection of both regular and difference ultrasound images. Similarly, two convolutional neural networks were trained, and both achieved an accuracy of over 95%. Conclusions: Wires with diameters as small as 50 µm were localized successfully in a water-based gelatin phantom, indicating the potential use of ultrasound to enhance endovascular navigation and surgical treatment.

2.
Phys Med Biol ; 62(15): 6026-6043, 2017 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-28582265

RESUMO

This simulation study presents the application of fluence field modulated computed tomography, initially developed for x-ray CT, to proton computed tomography (pCT). By using pencil beam (PB) scanning, fluence modulated pCT (FMpCT) may achieve variable image quality in a pCT image and imaging dose reduction. Three virtual phantoms, a uniform cylinder and two patients, were studied using Monte Carlo simulations of an ideal list-mode pCT scanner. Regions of interest (ROI) were selected for high image quality and only PBs intercepting them preserved full fluence (FF). Image quality was investigated in terms of accuracy (mean) and noise (standard deviation) of the reconstructed proton relative stopping power compared to reference values. Dose calculation accuracy on FMpCT images was evaluated in terms of dose volume histograms (DVH), range difference (RD) for beam-eye-view (BEV) dose profiles and gamma evaluation. Pseudo FMpCT scans were created from broad beam experimental data acquired with a list-mode pCT prototype. FMpCT noise in ROIs was equivalent to FF images and accuracy better than -1.3%(-0.7%) by using 1% of FF for the cylinder (patients). Integral imaging dose reduction of 37% and 56% was achieved for the two patients for that level of modulation. Corresponding DVHs from proton dose calculation on FMpCT images agreed to those from reference images and 96% of BEV profiles had RD below 2 mm, compared to only 1% for uniform 1% of FF. Gamma pass rates (2%, 2 mm) were 98% for FMpCT while for uniform 1% of FF they were as low as 59%. Applying FMpCT to preliminary experimental data showed that low noise levels and accuracy could be preserved in a ROI, down to 30% modulation. We have shown, using both virtual and experimental pCT scans, that FMpCT is potentially feasible and may allow a means of imaging dose reduction for a pCT scanner operating in PB scanning mode. This may be of particular importance to proton therapy given the low integral dose found outside the target.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Terapia com Prótons/métodos , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/instrumentação , Humanos , Método de Monte Carlo , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
3.
Nucl Instrum Methods Phys Res A ; 831: 394-399, 2016 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-27818559

RESUMO

We report on the operation and performance tests of a preclinical head scanner developed for proton computed tomography (pCT). After extensive preclinical testing, pCT is intended to be employed in support of proton therapy treatment planning and pre-treatment verification in patients undergoing particle-beam therapy. In order to assess the performance of the scanner, we have performed CT scans with 200 MeV protons from both the synchrotron of the Loma Linda University Medical Center (LLUMC) and the cyclotron of the Northwestern Medicine Chicago Proton Center (NMCPC). The very high sustained rate of data acquisition, exceeding one million protons per second, allowed a full 360° scan to be completed in less than 7 minutes. The reconstruction of various phantoms verified accurate reconstruction of the proton relative stopping power (RSP) and the spatial resolution in a variety of materials. The dose for an image with better than 1% uncertainty in the RSP is found to be close to 1 mGy.

4.
J Intern Med ; 274(2): 163-75, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23432360

RESUMO

BACKGROUND: Excess body weight and a sedentary lifestyle are associated with the development of several diseases, including cardiovascular disease, diabetes and cancer in women. One proposed mechanism linking obesity to chronic diseases is an alteration in adipose-derived adiponectin and leptin levels. We investigated the effects of 12-month reduced calorie, weight loss and exercise interventions on adiponectin and leptin concentrations. METHODS: Overweight/obese postmenopausal women (n = 439) were randomized as follows: (i) a reduced calorie, weight-loss diet (diet; N = 118), (ii) moderate-to-vigorous intensity aerobic exercise (exercise; N = 117), (iii) a combination of a reduced calorie, weight-loss diet and moderate-to-vigorous intensity aerobic exercise (diet + exercise; N = 117), and (iv) control (N = 87). The reduced calorie diet had a 10% weight-loss goal. The exercise intervention consisted of 45 min of moderate-to-vigorous aerobic activity 5 days per week. Adiponectin and leptin levels were measured at baseline and after 12 months of intervention using a radioimmunoassay. RESULTS: Adiponectin increased by 9.5% in the diet group and 6.6% in the diet + exercise group (both P ≤ 0.0001 vs. control). Compared with controls, leptin decreased with all interventions (diet + exercise, -40.1%, P < 0.0001; diet, -27.1%, P < 0.0001; exercise, -12.7%, P = 0.005). The results were not influenced by the baseline body mass index (BMI). The degree of weight loss was inversely associated with concentrations of adiponectin (diet, P-trend = 0.0002; diet + exercise, P-trend = 0.0005) and directly associated with leptin (diet, P-trend < 0.0001; diet + exercise, P-trend < 0.0001). CONCLUSION: Weight loss through diet or diet + exercise increased adiponectin concentrations. Leptin concentrations decreased in all of the intervention groups, but the greatest reduction occurred with diet + exercise. Weight loss and exercise exerted some beneficial effects on chronic diseases via effects on adiponectin and leptin.


Assuntos
Adiponectina/metabolismo , Dieta Redutora/métodos , Exercício Físico/fisiologia , Leptina/metabolismo , Obesidade/terapia , Adiponectina/análise , Idoso , Índice de Massa Corporal , Feminino , Seguimentos , Humanos , Leptina/análise , Pessoa de Meia-Idade , Obesidade/diagnóstico , Sobrepeso/diagnóstico , Sobrepeso/terapia , Pós-Menopausa , Valores de Referência , Medição de Risco , Fatores de Tempo , Resultado do Tratamento , Redução de Peso
6.
Adv Exp Med Biol ; 696: 157-70, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21431556

RESUMO

In the search for life on Mars and other extraterrestrial bodies or in our attempts to identify biological traces in the most ancient rock record of Earth, one of the biggest problems facing us is how to recognize life or the remains of ancient life in a context very different from our planet's modern biological examples. Specific chemistries or biological properties may well be inapplicable to extraterrestrial conditions or ancient Earth environments. Thus, we need to develop an arsenal of techniques that are of broader applicability. The notion of patterning created in some fashion by biological processes and properties may provide such a generalized property of biological systems no matter what the incidentals of chemistry or environmental conditions. One approach to recognizing these kinds of patterns is to look at apparently organized arrangements created and left by life in extreme environments here on Earth, especially at various spatial scales, different geologies, and biogeochemical circumstances.


Assuntos
Exobiologia , Modelos Biológicos , Biologia Computacional , Cianobactérias/crescimento & desenvolvimento , Planeta Terra , Meio Ambiente , Meio Ambiente Extraterreno , Fósseis , Geologia , Marte , Conceitos Matemáticos , Consórcios Microbianos , Origem da Vida , Reconhecimento Automatizado de Padrão
7.
Med Phys ; 36(10): 4511-8, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19928082

RESUMO

An accurate system matrix is required for quantitative proton CT (pCT) image reconstruction with iterative projection algorithms. The system matrix is composed of chord lengths of individual proton path intersections with reconstruction pixels. In previous work, reconstructions were performed assuming constant intersection chord lengths, which led to systematic errors of the reconstructed proton stopping powers. The purpose of the present work was to introduce a computationally efficient variable intersection chord length in order to improve the accuracy of the system matrix. An analytical expression that takes into account the discrete stepping nature of the pCT most likely path (MLP) reconstruction procedure was created to describe an angle-dependent effective mean chord length function. A pCT dataset was simulated with GEANT4 using a parallel beam of 200 MeV protons intersecting a computerized head phantom consisting of tissue-equivalent materials with known relative stopping power. The phantom stopping powers were reconstructed with the constant chord length, exact chord length, and effective mean chord length approaches, in combination with the algebraic reconstruction technique. Relative stopping power errors were calculated for each anatomical phantom region and compared for the various methods. It was found that the error of approximately 10% in the mean reconstructed stopping power value for a given anatomical region, resulting from a system matrix with a constant chord length, could be reduced to less than 0.5% with either the effective mean chord length or exact chord length approaches. Reconstructions with the effective mean chord length were found to be approximately 20% faster than reconstructions with an exact chord length. The effective mean chord length method provides the possibility for more accurate, computationally efficient quantitative pCT reconstructions.


Assuntos
Algoritmos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Prótons , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Med Phys ; 35(11): 4849-56, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19070218

RESUMO

The limited spatial resolution in proton computed tomography (pCT) in comparison to x-ray CT is related to multiple Coulomb scattering (MCS) within the imaged object. The current generation pCT design utilizes silicon detectors that measure the position and direction of individual protons prior to and post-traversing the patient to maximize the knowledge of the path of the proton within the imaged object. For efficient reconstruction with the proposed pCT system, one needs to develop compact and flexible mathematical formalisms that model the effects of MCS as the proton traverses the imaged object. In this article, a compact, matrix-based most likely path (MLP) formalism is presented employing Bayesian statistics and a Gaussian approximation of MCS. Using GEANT4 simulations in a homogeneous 20 cm water cube, the MLP expression was found to be able to predict the Monte Carlo tracks of 200 MeV protons to within 0.6 mm on average when employing 3sigma cuts on the relative exit angle and exit energy. These cuts were found to eliminate the majority of events not conforming to the Gaussian model of MCS used in the MLP derivation. M riszwana Banu


Assuntos
Prótons , Tomografia/métodos , Absorção , Funções Verossimilhança , Modelos Químicos , Método de Monte Carlo , Distribuição Normal , Imagens de Fantasmas , Sensibilidade e Especificidade , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA