Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
Biology (Basel) ; 12(8)2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37626989

RESUMO

OBJECTIVES: To compare the volumes and shapes of the coagulation zone (CZ) of a multi-probe RFA system (three RFA electrodes) and a single-probe MWA system from the same vendor in an ex vivo bovine liver model. MATERIAL & METHODS: A total of 48 CZs were obtained in bovine liver specimens with three different ablation system configurations (single-probe MWA vs. multi-probe RFA with 20 mm inter-probe distance [confluent CZ] vs. multi-probe RFA with 50 mm inter-probe distance [three individual CZs]) at 4, 6, 8, and 10 min ablation time using a fixed ablation protocol. Ablation diameters were measured and ellipticity indices (EIs) and volumes calculated. Calculations for all systems/configurations were compared. RESULTS: Volumes and diameters increased with ablation time for all configurations. At 4 and 6 min ablation time volumes obtained with the RFA 50 mm setup, and at 8 and 10 min with the RFA 20 mm setup were the largest at 26.5 ± 4.1 mL, 38.1 ± 5.8 mL, 46.3 ± 4.9 mL, 48.4 ± 7.3 mL, respectively. The single-probe MWA could not reach the volumes of the RFA setups for any of the ablation times evaluated. EI were very similar and almost round for RFA 20 mm and single-probe MWA, and differed significantly to the more ovoid ones for the RFA 50 mm configuration. CONCLUSIONS: The multi-probe RFA system employing three electrodes achieved significantly larger ablation volumes in both configurations (confluent CZ and three individual CZs) per time as compared with a single-probe MWA system in this ex vivo bovine liver model.

2.
J Med Imaging Radiat Oncol ; 67(8): 886-894, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37401185

RESUMO

For both primary and metastatic liver cancer, thermal ablation represents an interesting alternative to surgery. However, except for a small fraction of patients, conventional ultrasound- and CT-guided single-probe approaches have not achieved oncologic outcomes comparable with surgery. In this overview, we describe our stereotactic ablation workflow and discuss the short- and long-term results of stereotactic radiofrequency ablation (SRFA) and stereotactic microwave ablation (SMWA) for the treatment of primary and secondary liver tumours. The advantages of this method are discussed together with a summary of the existing stereotactic techniques for thermal ablation and the clinical data that support them. Stereotactic ablation is based on an optical navigation system and a specialized aiming tool. The workflow includes advanced three-dimensional planning, precise needle/probe placements according to the plan and intraoperative image fusion to check the needle positions and the ablation margins. Stereotactic ablation offers all the advantages of a minimally invasive procedure while producing oncological results comparable with surgery. The number of locally treatable liver cancers may be significantly expanded with these cutting-edge instruments and methods. We firmly believe that it can become a cornerstone in the treatment of liver cancers.


Assuntos
Ablação por Cateter , Neoplasias Hepáticas , Segunda Neoplasia Primária , Ablação por Radiofrequência , Cirurgia Assistida por Computador , Humanos , Ablação por Cateter/métodos , Cirurgia Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Segunda Neoplasia Primária/cirurgia
3.
Acad Radiol ; 30(12): 3047-3055, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37117142

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the targeting accuracy of laser-guided punctures in combination with an aiming device for computed tomography (CT) interventions during in vitro experiments. MATERIALS AND METHODS: A total of 600 CT-guided punctures were performed using a laser target system, half of them with the additional help of an aiming device. Conically shaped targets in a plexiglass phantom were punctured. The planning CT data sets were acquired with 1.25, 2.5 and 5 mm slice thickness. Needle placement accuracy, as well as procedural time, was assessed. The Euclidean (ED) and normal distances (ND) were calculated at the target point. RESULTS: Using the aiming device, the accomplished mean ND at the target for the 1.25, 2.5 and 5 mm slice thickness was 1.76 mm (SD ± 0.92), 2.09 mm (SD ± 1.06) and 1.93 mm (SD ± 1.38), respectively. Without aiming device, the corresponding results were 2.55 mm (SD ± 1.42), 2.7 mm (SD ± 1.43) and 2.31 mm (SD ± 1.64). At a slice thickness of 1.25 mm and 2.5 mm, punctures with the aiming device were significantly more accurate for both the ED and ND as compared to the punctures without aiming device (p < 0.001). The mean time required to complete the procedure, including image acquisition, trajectory planning, the placement of 10 needles, and the control-CT scan was 24.8 min without and 29.8 min with the aiming device. CONCLUSION: The additional use of the aiming device in combination with the commercially available laser guidance system significantly increased the level of accuracy during this in vitro experiment compared to freehand passes.


Assuntos
Agulhas , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Punções/métodos , Imagens de Fantasmas , Lasers
4.
Biology (Basel) ; 12(2)2023 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-36829454

RESUMO

PURPOSE: To compare the results of a novice with those of experienced interventional radiologists (IRs) for stereotactic radiofrequency ablation (SRFA) of malignant liver tumors in terms of safety, technical success, and local tumor control. METHODS: A database, including all SRFA procedures performed in a single center between January 2011 and December 2018 was retrospectively analyzed. A total of 39 ablation sessions performed by a novice IR were compared to the results of three more experienced IRs. Comparative SRFA sessions were selected using propensity score matching considering tumor type, age, sex, tumor size, and tumor number as matching variables. Overall, 549 target tumors were treated in 273 sessions. Median tumor size was 2.2 cm (1.0-8.5 cm) for 178 hepatocellular carcinomas (HCCs) and 3.0 cm (0.5-13.0 cm) for 371 metastases. A median of 2 (1-11) tumors were treated per session. RESULTS: No significant differences were observed when comparing the results of more experienced IRs with those of a novice IR regarding the rates of major complications (6.8% [16/234] vs. 5.1% [2/39]; p = 0.477), mortality (1.3% [2/234] vs. 0% [0/39]; p = 0.690), primary technical efficacy (98.5% [525/533] vs. 98.9% [94/95]; p = 0.735), and local recurrence (5.6% [30/533] vs. 5.3% [5/95]; p = 0.886). However, the median planning/placement time was significantly shorter for the experienced IRs (92 min vs. 119 min; p = 0.002). CONCLUSIONS: SRFA is a safe, effective, and reliable treatment option for malignant liver tumors and favorable outcomes can be achieved even by inexperienced operators with minimal supervision.

5.
J Clin Med ; 11(13)2022 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-35807029

RESUMO

Background: Robotic-based guidance systems are becoming increasingly capable of assisting in needle placement during interventional procedures. Despite these technical advances, less sophisticated low-cost guidance devices promise to enhance puncture accuracy compared with the traditional freehand technique. Purpose: To compare the in vitro accuracy and feasibility of two different aiming devices for computed-tomography (CT)-guided punctures. Methods: A total of 560 CT-guided punctures were performed by using either a robotic (Perfint Healthcare: Maxio) or a novel low-cost patient-mounted system (Medical Templates AG: Puncture Cube System [PCS]) for the placement of Kirschner wires in a plexiglass phantom with different slice thicknesses. Needle placement accuracy as well as procedural time were assessed. The Euclidean (ED) and normal distances (ND) were calculated at the entry and target point. Results: Using the robotic device, the ND at the target for 1.25 mm, 2.5 mm, 3.75 mm and 5 mm slice thickness were 1.28 mm (SD ± 0.79), 1.25 mm (SD ± 0.81), 1.35 mm (SD ± 1.00) and 1.35 mm (SD ± 1.03). Using the PCS, the ND at the target for 1 mm, 3 mm and 5 mm slices were 3.84 mm (SD ± 1.75), 4.41 mm (SD ± 2.31) and 4.41 mm (SD ± 2.11), respectively. With all comparable slice thicknesses, the robotic device was significantly more accurate compared to the low-cost device (p < 0.001). Needle placement with the PCS resulted in lower intervention time (mean, 158.83 s [SD ± 23.38] vs. 225.67 s [SD ± 17.2]). Conclusion: Although the robotic device provided more accurate results, both guidance systems showed acceptable results and may be helpful for interventions in difficult anatomical regions and for those requiring complex multi-angle trajectories.

6.
Eur Radiol ; 32(10): 6769-6776, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35678863

RESUMO

OBJECTIVES: To evaluate the targeting accuracy of stereotactic punctures based on a hybrid robotic device in combination with optical tracking-a phantom study. METHODS: CT data sets of a gelatin-filled plexiglass phantom with 1-, 3-, and 5-mm slice thickness were acquired. An optical navigation device served for planning of a total of 150 needle trajectories. All punctures were carried out semi-automatically with help of the trackable iSYS-1 robotic device. Conically shaped targets inside the phantom were punctured using Kirschner wires. Up to 8 K-wires were positioned sequentially based on the same planning CT and placement accuracy was assessed by taking control CTs and measuring the Euclidean (ED) and normal distances (NDs) between the wire and the entry and target point. RESULTS: Using the StealthStation S7, the accomplished mean ND at the target for the 1-mm, 3-mm, and 5-mm slice thickness was 0.89 mm (SD ± 0.42), 0.93 mm (SD ± 0.45), and 0.73 mm (SD ± 0.50), respectively. The corresponding mean ED was 1.61 mm (SD ± 0.36), 2.04 mm (SD ± 0.59), and 1.76 mm (SD ± 0.45). The mean duration of the total procedure was 27.9 min, including image acquisition, trajectory planning, registration, placement of 8 wires, and the control-CT. CONCLUSIONS: The optically tracked iSYS-1 robot allows for precise punctures in a phantom. The StealthStation S7 provided acceptable results and may be helpful for interventions in difficult anatomical regions and for those requiring complex multi-angle trajectories. In combination with our optical navigation tool, the trackable robot unit allows to cover a large treatment field and the compact design facilitates placement of needle-like instruments. KEY POINTS: • The use of a robotic targeting device in combination with optical tracking (hybrid system) allows for accurate placement of needle-like instruments without repeated control imaging. • The compact robotic positioning unit in combination with a camera for optical tracking facilitates sequential placement of multiple K-wires in a large treatment volume.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Imageamento Tridimensional , Imagens de Fantasmas , Punções
7.
Int J Hyperthermia ; 39(1): 780-787, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35654476

RESUMO

OBJECTIVES: This study aimed to assess the safety and efficacy of stereotactic radiofrequency ablation (SRFA) in patients with hepatocellular adenomas (HCA). METHODS: Retrospective analyses of all patients referred for SRFA treatment at our institution between January 2010 and October 2020 revealed 14 patients (10 women; mean age 34.4 [range, 17-73 years]) with 38 HCAs treated through 18 ablation sessions. Ablations were considered successful if a safety margin >5 mm was achieved. Demographic, interventional, and outcome data were collected and analyzed. Primary and secondary technical efficacy rates were assessed based on follow-up images consisting of contrast-enhanced CT or MR scans. RESULTS: The mean tumor size was 22 mm (range, 7-75 mm). Overall, 37/38 (97.4%) tumors were successfully ablated at the initial SRFA (primary efficacy rate of 97.4%). The median follow-up duration was 49.6 months. No deaths or adenoma-related complications (hemorrhage or malignant transformation) were observed. Disease-free survival rates at 1, 3, and 5 years from the date of the first SRFA were 100%, 85.8%, and 85.8%, respectively. Two patients developed new distant tumors retreated with consecutive re-ablation. No major complications occurred during any of the 18 ablation sessions. CONCLUSIONS: Percutaneous thermal ablation is efficient in the treatment of HCAs and may thus be considered a valid first-line treatment option. In addition, SRFA allows for an effective, minimally invasive treatment of large and multiple hepatic tumors within one session.


Assuntos
Adenoma de Células Hepáticas , Carcinoma Hepatocelular , Neoplasias Hepáticas , Ablação por Radiofrequência , Adenoma de Células Hepáticas/cirurgia , Adulto , Carcinoma Hepatocelular/cirurgia , Feminino , Humanos , Neoplasias Hepáticas/patologia , Estudos Retrospectivos
8.
Int J Hyperthermia ; 39(1): 421-430, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35227136

RESUMO

PURPOSE: To assess the technical outcome and local tumor control of multi-probe stereotactic radiofrequency ablation (SRFA) in a large series of patients. Furthermore, to determine factors accounting for adverse outcomes. MATERIAL AND METHODS: Between 2003 and 2018, 865 patients were treated by SRFA for 2653 primary and metastatic liver tumors with a median tumor size of 2.0 cm (0.5 - 19 cm). Primary technical efficacy (PTE) and local recurrence (LR) were evaluated, and possible predictors for adverse events analyzed using uni- and multi-variable binary logistic regression. RESULTS: Overall, 2553 of 2653 tumors were successfully ablated at initial SRFA resulting in a PTE rate of 96.2%. Predictors of lower PTE rates were age > 70 years, tumor size > 5 cm, number of probes, location close to liver capsule/organs and segment II. LR occurred in 220 of 2653 tumors (8.3%) with the following predictors: age, tumor type/size, conglomerates, segments I/IVa/IVb, number of probes and location close to major vessels/bile duct. Multivariable analysis revealed tumor size > 5 cm (odds ratio [OR] 3.153), age > 70 years (OR 1.559), and location in segment II (OR 1.772) as independent prognostic factors for PTE, whereas tumor location close to major vessels (OR 1.653) and in segment IVb (OR 2.656) were identified as independent prognostic factors of LR. CONCLUSIONS: Stereotactic RFA is an attractive option in the management of primary or metastatic liver tumors with good local tumor control, even in large tumors. The presented prognostic factors for adverse local oncological outcome might help to stratify unfavorable tumors for ablation.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Ablação por Radiofrequência , Idoso , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/métodos , Humanos , Neoplasias Hepáticas/patologia , Recidiva Local de Neoplasia/cirurgia , Prognóstico , Ablação por Radiofrequência/métodos , Estudos Retrospectivos , Resultado do Tratamento
9.
PLoS One ; 17(1): e0261136, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34982804

RESUMO

BACKGROUND: To evaluate the efficacy, safety and overall clinical outcome of local treatment for recurrent intrahepatic cholangiocellular carcinoma after hepatic resection. METHODS: Between 2007 and 2019 72 consecutive patients underwent hepatic resection for primary intrahepatic cholangiocellular carcinoma. If amenable, recurrent tumors were aggressively treated by HR or stereotactic radiofrequency ablation with local curative intent. Endpoints consisted of morbidity and mortality, locoregional and de novo recurrence, disease free survival, and overall survival. RESULTS: After a median follow-up of 28 months, recurrence of intrahepatic cholangiocellular carcinoma was observed in 43 of 72 patients undergoing hepatic resection (60.3%). 16 patients were subsequently treated by hepatic resection (n = 5) and stereotactic radiofrequency ablation (n = 11) with local curative intention. The remaining 27 patients underwent palliative treatment for first recurrence. Overall survival of patients who underwent repeated aggressive liver-directed therapy was comparable to patients without recurrence (p = 0.938) and was better as compared to patients receiving palliative treatment (p = 0.018). The 5-year overall survival rates for patients without recurrence, the repeated liver-directed treatment group and the palliative treatment group were 54.3%, 47.7% and 12.3%, respectively. By adding stereotactic radiofrequency ablation as an alternative treatment option, the rate of curative re-treatment increased from 11.9% to 37.2%. CONCLUSION: Repeated hepatic resection is often precluded due to patient morbidity or anatomical and functional limitations. Due to the application of stereotactic radiofrequency ablation in case of recurrent intrahepatic cholangiocellular carcinoma, the number of patients treated with curative intent can be increased. This leads to favorable clinical outcome as compared to palliative treatment of intrahepatic cholangiocellular carcinoma recurrence.


Assuntos
Colangiocarcinoma/cirurgia , Neoplasias Hepáticas/cirurgia , Ablação por Radiofrequência , Adulto , Idoso , Idoso de 80 Anos ou mais , Colangiocarcinoma/mortalidade , Colangiocarcinoma/patologia , Intervalo Livre de Doença , Feminino , Seguimentos , Hepatectomia , Humanos , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Cuidados Paliativos , Taxa de Sobrevida , Resultado do Tratamento
11.
HPB (Oxford) ; 24(7): 1044-1054, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34887174

RESUMO

BACKGROUND: Radiofrequency ablation (RFA) is subject to "heat-sink" effects, particularly for treatment of tumors adjacent to major vessels. METHODS: In this retrospective study, 104 patients with 137 tumors (40 HCC, 10 ICC and 54 metastatic liver tumors) close to (≤1 cm from) the hepatic venous confluence underwent stereotactic RFA (SRFA) between June 2003 and June 2018. Median tumor size was 3.7 cm (1.4-8.5) for HCC, 6.4 cm (0.5-11) for ICC and 3.8 cm (0.5-13) for metastases. Endpoints comprised safety, local tumor control, overall and disease-free survival. RESULTS: The overall major complication rate was 16.0% (20/125 ablations), where 8 (40%) were successfully treated by the interventional radiologist in the same anesthetic session and did not prolong hospital stay. 134/137 (97.8%) tumors were successfully ablated at initial SRFA. Local recurrence (LR) developed in 19/137 tumors (13.9%). The median and overall survival (OS) rates at 1-, 3-, and 5- years from the date of the first SRFA were 51.5 months, 73.5%, 67.0%, and 49.7% for HCC, 14.6 months, 60.0%, 32.0% and 32.0% for ICC and 38.1 months, 91.4%, 56.5% and 27.9% for metastatic disease, respectively. CONCLUSION: SRFA represents a viable alternative to hepatic resection for challenging tumors at the hepatic venous confluence.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Ablação por Radiofrequência , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Recidiva Local de Neoplasia , Ablação por Radiofrequência/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
12.
Biology (Basel) ; 10(7)2021 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-34356499

RESUMO

Thermal ablation is an emerging, potentially curative approach in treating primary and metastatic liver cancer. Different technologies are available, with radiofrequency ablation (RFA) and microwave ablation (MWA) being the most widely used. Regardless of the technique, destruction of the entire tumor, including an adequate safety margin, is key. In conventional single-probe US- or CT-guided thermal ablation, the creation of such large necrosis zones is often hampered by technical limitations, especially for large tumors (i.e., >2-3 cm). These limitations have been overcome by stereotactic RFA (SRFA): a multiple needle approach with 3D treatment planning and precise stereotactic needle placement combined with intraprocedural image fusion of pre- and post-interventional CT scans for verification of treatment success. With these sophisticated tools and advanced techniques, the spectrum of locally curable liver malignancies can be dramatically increased. Thus, we strongly believe that stereotactic thermal ablation can become a cornerstone in the treatment of liver malignancies, as it offers all the benefits of a minimally invasive method while providing oncological outcomes comparable to surgery. This article provides an overview of current stereotactic techniques for thermal ablation, summarizes the available clinical evidence for this approach, and discusses its advantages.

14.
Cardiovasc Intervent Radiol ; 44(8): 1184-1193, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33825059

RESUMO

PURPOSE: To evaluate safety, local oncological control, long-term outcome and potential prognostic factors of stereotactic RFA (SRFA) for the treatment of BCLMs. METHODS: Between July 2003 and December 2019, 42 consecutive female patients with median age 54.0 years were treated with SRFA at our institution for 110 BCLMs in 48 ablation sessions. Median tumor size was 3.0 cm (0.8-9.0). Eighteen (42.9%) patients had extrahepatic metastasis at initial SRFA. RESULTS: Technical success rate was 100%, i.e., all coaxial needles were inserted with appropriate accuracy within 10 mm off plan and 107/110 (92.3%) BCLMs were successfully ablated at initial SRFA. Four Grade 1 (8.3%, 4/48) and one Grade 2 (2.1%, 1/48) complications occurred. No perioperative deaths occurred. Local recurrence developed in 8 of 110 tumors (7.3%). Overall survival (OS) rates of all patients at 1, 3, and 5 years from the date of the first SRFA were 84.1%, 49.3%, and 20.8% with a median OS of 32.3 months. Univariable cox regression analyses revealed age > 60 years and extrahepatic disease (without bone only metastases) as significant predictors of worse OS (p = 0.013 and 0.025, respectively). Size and number of metastases, hormone receptor status and time onset did not significantly affect OS after initial SRFA. CONCLUSIONS: SRFA is a safe, minimally invasive treatment option in the management of BCLMs, especially in younger patients without advanced extrahepatic metastasis, including those with large liver tumors.


Assuntos
Neoplasias da Mama/patologia , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Ablação por Radiofrequência/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida , Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
15.
Eur Radiol ; 31(9): 6489-6499, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33447860

RESUMO

OBJECTIVES: To retrospectively assess the periablational 3D safety margin in patients with colorectal liver metastases (CRLM) referred for stereotactic radiofrequency ablation (RFA) and to evaluate its influence on local treatment success. METHODS: Forty-five patients (31 males; mean age 64.5 [range 31-87 years]) with 76 CRLM were treated with stereotactic RFA and retrospectively analyzed. Image fusion of pre- and post-interventional contrast-enhanced CT scans using a non-rigid registration software enabled a retrospective assessment of the percentage of predetermined periablational 3D safety margin and CRLM successfully ablated. Periablational safety zones (1-10 mm) and percentage of periablational zone ablated were calculated, analyzed, and compared with subsequent tumor growth to determine an optimal safety margin predictive of local treatment success. RESULTS: Mean overall follow-up was 36.1 ± 18.5 months. Nine of 76 CRLMs (11.8%) developed local tumor progression (LTP) with mean time to LTP of 18.3 ± 11.9 months. Overall 1-, 2-, and 3-year cumulative LTP-free survival rates were 98.7%, 90.6%, and 88.6%, respectively. The periablational safety margin assessment proved to be the only independent predictor (p < 0.001) of LTP for all calculated safety margins. The smallest safety margin 100% ablated displaying no LTP was 3 mm, and at least 90% of a 6-mm circumscribed 3D safety margin was required to achieve complete ablation. CONCLUSIONS: Volumetric assessment of the periablational safety margin can be used as an intraprocedural tool to evaluate local treatment success in patients with CRLM referred to stereotactic RFA. Ablations achieving 100% 3D safety margin of 3 mm and at least 90% 3D safety margin of 6 mm can predict treatment success. KEY POINTS: • Volumetric assessment of the periablational safety margin can be used as an intraprocedural tool to evaluate local treatment success following thermal ablation of colorectal liver metastases. • Ablations with 100% 3D periablational safety margin of 3 mm and ablations with at least 90% 3D safety margin of 6 mm can be considered indications of treatment success. • Image fusion of pre- and post-interventional CT scans with the software used in this study is feasible and could represent a useful tool in daily clinical practice.


Assuntos
Ablação por Cateter , Neoplasias Colorretais , Neoplasias Hepáticas , Ablação por Radiofrequência , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Colorretais/cirurgia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Masculino , Margens de Excisão , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
16.
Eur J Surg Oncol ; 47(4): 866-873, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33032865

RESUMO

BACKGROUND: To evaluate the efficacy, safety and overall clinical outcome of multiprobe SRFA as a treatment for recurrent colorectal liver metastases after hepatic resection (HR). METHODS: A retrospective, single center study carried out between 2006 and 2018. 64 consecutive patients with recurrent or new CRLM after previous HR were treated by SRFA for 217 lesions (median size 2.7 cm, 1-7.5) in 103 ablation sessions. Endpoints consisted of i) technical efficacy ii) complication and mortality rates iii) local and distant recurrence, iv) disease free survival (DFS), and v) overall survival (OS). RESULTS: 213/217 tumors were successfully ablated at initial SRFA (97.7% primary technical efficacy rate). Four tumors required repeat ablation, resulting in a secondary technical efficacy rate of 99.5% (216/217). Local recurrence developed in 25/217 lesions (11.5%). Major complication rate was 5.8% (6/103 sessions) and mortality rate was 1.0% (1/103 ablation sessions), respectively.1-, 3-, and 5- year OS rates from date of first SRFA were 90.1%, 46.2%, and 34.8% (median 33.1 months). DFS rates were 54.2%, 17.2%, and 17.2%, at 1-, 3- and 5- years, respectively (median 13.3 months). CONCLUSION: SRFA is a safe, feasible and effective option for CRLM after HR with low morbidity levels and favorable clinical outcome.


Assuntos
Neoplasias Colorretais/patologia , Neoplasias Hepáticas/cirurgia , Recidiva Local de Neoplasia/patologia , Ablação por Radiofrequência/métodos , Cirurgia Assistida por Computador , Adulto , Idoso , Intervalo Livre de Doença , Feminino , Hepatectomia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida , Tomografia Computadorizada por Raios X
17.
Eur Radiol ; 31(5): 3042-3052, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33125554

RESUMO

OBJECTIVES: To assess the frequency of major complications after multi-probe stereotactic radiofrequency ablation (SRFA) in a large cohort of patients over 15 years and to elucidate risk factors for adverse events. MATERIALS AND METHODS: A retrospective study was carried out between July 2003 and December 2018. Seven hundred ninety-three consecutive patients (median 65.0 years (0.3-88), 241 women and 552 men, were treated in 1235 SRFA sessions for 2475 primary and metastatic liver tumors with a median tumor size of 3.0 cm (0.5-18 cm). The frequency of major complications was evaluated according to SIR guidelines and putative predictors of adverse events analyzed using simple and multivariable logistic regression. RESULTS: Thirty-day mortality after SRFA was 0.5% (6/1235) with an overall major complication rate of 7.4% (91/1235). The major complication rate decreased from 11.5% (36/314) (before January 2011) to 6.0% (55/921) (p = 0.001). 50.5% (46/91) of major complications were successfully treated in the same anesthetic session by angiographic coiling for hemorrhage and chest tube insertion for pneumothorax. History of bile duct surgery/intervention, number of coaxial needles, and location of tumors in segment IVa or VIII were independent prognostic factors for major complications following multivariable logistic regression analysis. Simple logistic regression revealed the number of tumors, tumor size, location close to the diaphragm, tumor conglomerate, and segment VII as other significant predictors. CONCLUSION: SRFA of liver tumors is safe and can extend the treatment spectrum of conventional RFA. Adaptations over time combined with increasing experience resulted in a significant decrease in complications. KEY POINTS: • In 1235 ablation sessions in 793 patients over 15 years, we found a mortality rate of 0.5% (6/1235) and an overall major complication rate of 7.4%, which fell from 11.5 (36/314) to 6.0% (55/921, p = 0.001) after January 2011, likely due to procedural adaptations. • History of bile duct surgery/intervention (p = 0.013, OR = 3.290), number of coaxial needles (p = 0.026, OR = 1.052), and location of tumors in segment IVa (p = 0.016, OR = 1.989) or VIII (p = 0.038, OR = 1.635) were found to be independent prognostic factors. • Simple logistic regression revealed that number of tumors, tumor size, location close to the diaphragm, tumor conglomerates, and segment VII were other significant predictors of major complications.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Ablação por Radiofrequência , Carcinoma Hepatocelular/cirurgia , Feminino , Humanos , Neoplasias Hepáticas/cirurgia , Masculino , Ablação por Radiofrequência/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
18.
Int J Hyperthermia ; 37(1): 1362-1367, 2020 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-33302747

RESUMO

OBJECTIVES: To assess the difficulties in the immediate judgment of treatment success after radiofrequency ablation (RFA) of liver tumors by visual inspection alone and to evaluate whether radiologist's expertise affects the resultant judgment. METHODS: Peri-interventional CT-scans of nine patients with nine hepatocellular carcinomas with known outcomes after RFA were presented to 38 participants from 14 different countries. In a total of 342 reads, all interventional oncologists assessed the pre- and immediate post-interventional CT-scans through conventional side-by-side juxtapositioning of images and judged whether complete ablation (i.e., technical success and technique efficacy) was achieved. Results were compared regarding expertise in percutaneous tumor ablation (>50 interventions performed). An 'overcall' was defined as insufficient ablation that was misjudged as sufficient, and an 'undercall' as an erroneous assessment of complete ablation. RESULTS: Overall 3.97 ± 1.27 out of 9 (44.1%) cases per radiologist were misjudged. The mean number of overcalls and undercalls per radiologist were 0.74 ± 0.50 out of 2 (37.0%), and 3.24 ± 1.28 out of 7 (46.3%), respectively. 18/38 (47.4%) participants had considerable experience in percutaneous tumor ablation, with such expertise having no significant influence on the results (overall: p = 0.70; overcalls: p = 0.87; undercalls: p = 0.75). CONCLUSIONS: Conventional side-by-side evaluation of treatment success after RFA of liver tumors by the juxtaposition of pre- and post-interventional CT-scans is very difficult for experienced radiologists. The implementation of advanced processing techniques such as rigid/non-rigid image fusion with the assessment of the periablational margin is thus likely needed in order to decrease errors and objectively evaluate technical success and predict technique efficacy of liver RFA.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Oncologistas , Ablação por Radiofrequência , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
19.
Int J Hyperthermia ; 37(1): 1074-1081, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32954876

RESUMO

BACKGROUND AND AIMS: Surgical resection is currently the cornerstone of liver tumor treatment in children. In adults radiofrequency ablation (RFA) is an established minimally invasive treatment option for small focal liver tumors. Multiprobe stereotactic RFA (SRFA) with intraoperative image fusion to confirm ablation margins allows treatment for large lesions. We describe our experience with SRFA in children with liver masses. METHODS: SRFA was performed in 10 patients with a median age of 14 years (range 0.5-17.0 years) suffering from liver adenoma (n = 3), hepatocellular carcinoma (n = 1), hepatoblastoma (n = 2), myofibroblastic tumor (n = 1), hepatic metastases of extrahepatic tumors (n = 2) and infiltrative hepatic cysts associated with alveolar echinococcosis (n = 1). Overall, 15 lesions with a mean lesion size of 2.6 cm (range 0.7-9.5 cm) were treated in 11 sessions. RESULTS: The technical success rate was 100%, as was the survival rate. No transient adverse effects higher than grade II (Clavien and Dindo) were encountered after interventions. The median hospital stay was 5 d (range 2-33 d). In two patients who subsequently underwent transplant hepatectomy complete ablation was histologically confirmed. Follow-up imaging studies (median 55 months, range 18-129 months) revealed no local or distant recurrence of disease in any patient. CONCLUSIONS: SRFA is an effective minimal-invasive treatment option in pediatric patients with liver tumors of different etiologies.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Ablação por Radiofrequência , Adolescente , Adulto , Carcinoma Hepatocelular/cirurgia , Criança , Pré-Escolar , Humanos , Lactente , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Recidiva Local de Neoplasia/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
20.
Sci Rep ; 10(1): 12809, 2020 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-32732877

RESUMO

The purpose of this study was to evaluate the health-related quality of life (HRQoL) after stereotactic radiofrequency ablation (SRFA) of liver tumors and identify variables associated with decreased HRQoL and to compare it to other treatments in case of concurrency. From 2011 to 2017 577 patients underwent SRFA for liver tumors in 892 ablation sessions. 303 (52.5%) patients completed a HRQoL questionnaire once after the ablation. HRQoL was assessed by the Short Form (SF)-12 health survey with mental and physical component scales and by a general questionnaire to assess disease and treatment-specific items as well as to compare tolerability of SRFA to transarterial chemoembolization (TACE), hepatic resection (HR) and chemotherapy (CTX). The median SF-12 PCS was 46.6 and MCS was 53.2. Patients experiencing pain or complications and patients refusing repeat SRFA showed significantly lower PCS (43.2 vs 48.6, p = 0.0003; 32.8 vs 46.9, p = 0.005 and 40.6 vs 46.9, p = 0.009). 355 (97.8%) patients indicated willingness to undergo repeat SRFA with little to no fear in 292 (80.7%) patients. Among patients with multiple therapies, SRFA was rated by 40 (90.9%) as preferred re-treatment, HR by 1 (2.3%) and CTX by 3 (6.8%). In conclusion, we have shown that SRFA has good HRQoL-outcomes and reported low morbidity rates. Consequently the vast majority of study patients would accept a repeated SRFA if necessary (97.8%), without fear (80.7%). SRFA was preferred among patients who experienced concurrent treatments, such as HR or CTX.


Assuntos
Neoplasias Hepáticas/psicologia , Neoplasias Hepáticas/cirurgia , Preferência do Paciente , Ablação por Radiofrequência/métodos , Técnicas Estereotáxicas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Quimioembolização Terapêutica , Criança , Tratamento Farmacológico , Medo , Feminino , Hepatectomia , Humanos , Masculino , Pessoa de Meia-Idade , Morbidade , Inquéritos e Questionários , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA