Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Animals (Basel) ; 14(2)2024 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-38275790

RESUMO

Mitral and aortic valve insufficiencies have been commonly reported in horses. The objective of this study was to establish the use of acoustic cardiography (Audicor®) in horses with aortic (AI) or mitral valve insufficiency (MI). A total of 17 healthy horses, 18 horses with AI, and 28 horses with MI were prospectively included. None of the horses was in heart failure. Echocardiography and Audicor® analyses were conducted. Electromechanical activating time (EMAT), rate-corrected EMATc, left ventricular systolic time (LVST), rate-corrected LVSTc, and intensity and persistence of the third and fourth heart sound (S3, S4) were reported by Audicor®. Graphical analysis of the three-dimensional (3D) phonocardiogram served to visually detect murmurs. Audicor® snapshot variables were compared between groups using one-way ANOVA followed by Tukey's multiple-comparisons test. The association between Audicor® snapshot variables and the corresponding echocardiographic variables was investigated by linear regression and Bland-Altman analyses. Heart murmurs were not displayed on Audicor® phonocardiograms. No significant differences were found between Audicor® variables obtained in clinically healthy horses and horses with valvular insufficiency. The Audicor® device is unable to detect heart murmurs in horses. Audicor® variables representing cardiac function are not markedly altered, and their association with corresponding echocardiographic variables is poor in horses with valvular insufficiency that are not in heart failure.

2.
J Vet Intern Med ; 36(4): 1471-1480, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35657023

RESUMO

BACKGROUND: Focused cardiac ultrasound examination (FoCUS) is rapidly emerging for point-of-care cardiac assessment using hand-carried ultrasound (HCU) devices. A specific FoCUS protocol for horses and adequate training guidelines currently are not available. HYPOTHESIS: To gain knowledge about the training necessary to become proficient in performing FoCUS using a HCU device. ANIMALS: Three healthy Warmblood horses were used for practical training of veterinarians and veterinary students in equine focused cardiac ultrasound (eFoCUS). METHODS: Prospective educational study. An eFoCUS protocol and 1-day training course were developed. Pre- and post-course written tests were administered to participants to evaluate proficiency in knowledge of echocardiography and echocardiographic pathology. A post-course practical examination involved performing eFoCUS and storage of representative images. Images were evaluated using an image quality score and compared between participants with some practical experience and participants with no practical experience. RESULTS: Participants' knowledge of echocardiography increased significantly. Recognition of echocardiographic pathology pre-course ranged from 40% to 90% (mean score, 65.7%) and post-course from 85% to 100% (mean score, 92%). Eighteen of 21 participants were proficient in performing eFoCUS with a median image quality score of 79% (range, 42%-95%). Image quality did not differ between participants with some practical experience compared to participants with no experience. CONCLUSIONS AND CLINICAL IMPORTANCE: Veterinarians and veterinary students independent of previous experience can become proficient in performing eFoCUS after completion of a 1-day training course.


Assuntos
Médicos Veterinários , Animais , Cuidados Críticos , Ecocardiografia/veterinária , Cavalos , Humanos , Estudos Prospectivos , Ultrassonografia/veterinária
3.
Equine Vet J ; 54(6): 1013-1022, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34957586

RESUMO

BACKGROUND: The recurrence rate of atrial fibrillation (AF) in horses after cardioversion to sinus rhythm (SR) is relatively high. Atrial fibrillatory rate (AFR) derived from surface ECG is considered a biomarker for electrical remodelling and could potentially be used for the prediction of successful AF cardioversion and AF recurrence. OBJECTIVES: Evaluate if AFR was associated with successful treatment and could predict AF recurrence in horses. STUDY DESIGN: Retrospective multicentre study. METHODS: Electrocardiograms (ECG) from horses with persistent AF admitted for cardioversion with either medical treatment (quinidine) or transvenous electrical cardioversion (TVEC) were included. Bipolar surface ECG recordings were analysed by spatiotemporal cancellation of QRST complexes and calculation of AFR from the remaining atrial signal. Kaplan-Meier survival curve and Cox regression analyses were performed to assess the relationship between AFR and the risk of AF recurrence. RESULTS: Of the 195 horses included, 74 received quinidine treatment and 121 were treated with TVEC. Ten horses did not cardiovert to SR after quinidine treatment and AFR was higher in these, compared with the horses that successfully cardioverted to SR (median [interquartile range]), (383 [367-422] vs 351 [332-389] fibrillations per minute (fpm), P < .01). Within the first 180 days following AF cardioversion, 12% of the quinidine and 34% of TVEC horses had AF recurrence. For the horses successfully cardioverted with TVEC, AFR above 380 fpm was significantly associated with AF recurrence (hazard ratio = 2.4, 95% confidence interval 1.2-4.8, P = .01). MAIN LIMITATIONS: The treatment groups were different and not randomly allocated, therefore the two treatments cannot be compared. Medical records and the follow-up strategy varied between the centres. CONCLUSIONS: High AFR is associated with failure of quinidine cardioversion and AF recurrence after successful TVEC. As a noninvasive marker that can be retrieved from surface ECG, AFR can be clinically useful in predicting the probability of responding to quinidine treatment as well as maintaining SR after electrical cardioversion.


Assuntos
Fibrilação Atrial , Doenças dos Cavalos , Animais , Fibrilação Atrial/terapia , Fibrilação Atrial/veterinária , Cardioversão Elétrica/veterinária , Eletrocardiografia/veterinária , Átrios do Coração , Doenças dos Cavalos/terapia , Cavalos , Quinidina
4.
Vet J ; 268: 105590, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33468305

RESUMO

Heart rate variability (HRV) analysis has been performed on ECG-derived data sets for more than 170 years but is currently undergoing a rapid evolution, thanks to the expansion of the human and veterinary medical technology sector. Traditional HRV analysis was initially performed to identify changes in vago-sympathetic balance, while the most recent focus has expanded to include the use of complex computer algorithms, neural networks and machine learning technology to identify cardiac arrhythmias, particularly atrial fibrillation (AF). Some of these techniques have recently been translated for use in the field of equine cardiology, with particular focus on improving the diagnosis of arrhythmias both at rest and during exercise. This review focuses on understanding the basic HRV variables and important factors to consider when collecting data for use in HRV analysis. In addition, the use of HRV analysis for the diagnosis of arrhythmias is discussed from human, small animal and equine perspectives. Finally, the future of HRV analysis is briefly introduced, including an overview of future developments in this rapidly expanding and exciting field.


Assuntos
Fibrilação Atrial/veterinária , Determinação da Frequência Cardíaca/veterinária , Frequência Cardíaca/fisiologia , Doenças dos Cavalos/diagnóstico , Animais , Fibrilação Atrial/diagnóstico , Determinação da Frequência Cardíaca/métodos , Cavalos
5.
J Vet Intern Med ; 35(1): 504-520, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33247461

RESUMO

BACKGROUND: Echocardiographic assessment of left ventricular (LV) size and function using area-based indices and volumetric estimates is not well established in horses. OBJECTIVE: To report reference intervals and measurement variability for uni-, 2-, and 3-dimensional echocardiographic indices of LV size and systolic function in Warmblood horses and to provide proof of concept for allometric scaling of variables to body weight. Unidimensional indices were to be compared to area-based indices and LV volume estimates to establish their clinical use. ANIMALS: Thirty healthy Warmblood horses and 70 Warmblood horses with a primary diagnosis of mitral regurgitation or aortic regurgitation. METHODS: Echocardiographic indices of LV size and systolic function were measured using an existing echocardiography database. Weight-related variables were scaled to body weight (BWT). Reference intervals and measurement variability were calculated, the influence of valvular regurgitation on LV size and function was investigated and agreement between different variables for detection of reduced, normal, and increased LV size and systolic function was assessed. RESULTS: Reference values for healthy Warmblood horses were reported. Measurement variability was sufficiently low for clinical use of all variables. Allometric scaling was effective to correct diastolic LV dimensions and cardiac output for differences in BWT. Various echocardiographic indices resulted in different conclusions regarding identification of LV enlargement and systolic dysfunction in healthy horses and horses with valvular regurgitation. CONCLUSIONS AND CLINICAL IMPORTANCE: Echocardiographic assessment of LV size and systolic function should include joint assessment of multiple uni- and multidimensional indices. Area-based or volumetric indices that reflect LV long-axis motion should be included.


Assuntos
Doenças dos Cavalos , Insuficiência da Valva Mitral , Animais , Diástole , Ecocardiografia/veterinária , Cavalos , Insuficiência da Valva Mitral/veterinária , Estudos Retrospectivos , Sístole
6.
J Vet Emerg Crit Care (San Antonio) ; 31(3): 323-330, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33274835

RESUMO

OBJECTIVES: The optimal dosage regimen of gentamicin in horses is still under investigation. The objectives of this study were to determine gentamicin plasma concentrations in hospitalized horses treated with 10 mg/kg gentamicin (IV, q 24 h) and to determine whether a plasma concentration to minimum inhibitory concentration (MIC) ratio of 10:1 is reached for equine pathogens using this dose. DESIGN: Prospective clinical observational study; retrospective study on MICs of 131 gram-negative bacteria isolated from horses (2012-2015). SETTING: University teaching hospital. ANIMALS: Ninety-eight horses >6 months old, treated with gentamicin for their primary disease, consecutive samples. MEASUREMENTS AND MAIN RESULTS: Plasma concentrations were measured 1 hour (C1h ) and 20 hours (C20h ) after gentamicin administration using fluorescence polarization. Presence of systemic inflammatory response syndrome (SIRS) and azotemia was recorded, as well as the reason for antimicrobial administration (primary disease) and whether administration was prophylactic or therapeutic. The target C1h of ≥20 µg/mL gentamicin was reached in 90% of horses and was sufficient to reach a plasma concentration:MIC of 10:1 in 32 of 131 (24%) of gram-negative aerobic bacteria. A C20h ≤ 2 µg/mL was reached in 97% horses. Therapeutic versus prophylactic administration, primary disease, azotemia, and systemic inflammatory response syndrome were not associated with a failure to reach a desired peak or trough. CONCLUSIONS: The gentamicin dose of 10 mg/kg every 24 hours should be further investigated and safety assessed because a target gentamicin plasma concentration of ≥20 µg/mL was achieved in the majority of cases. Nephrotoxic side effects were not assessed. Individual drug monitoring should be performed because clinical factors are unreliable predictors of plasma concentrations. A gentamicin target concentration of ≥40 µg/mL does not offer additional benefits compared to ≥20 µg/mL, due to the bimodal distribution of resistance in bacterial isolates.


Assuntos
Antibacterianos/sangue , Farmacorresistência Bacteriana , Gentamicinas/sangue , Bactérias Gram-Negativas/efeitos dos fármacos , Animais , Cavalos , Testes de Sensibilidade Microbiana , Estudos Prospectivos , Estudos Retrospectivos
8.
J Vet Pharmacol Ther ; 43(5): 470-476, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32333680

RESUMO

Dobutamine is routinely used to improve cardiovascular function in anaesthetized horses. However, dobutamine in conscious horses is insufficiently investigated. Ten research horses that were already instrumented for a preceding trial were included into the study. Cardiovascular variables were recorded and blood samples taken after instrumentation (Baseline), before starting dobutamine and after 10 min of dobutamine infusion (2 µg kg-1  min-1 ). A significant increase in systemic blood pressure, mean pulmonary artery pressure and right atrial pressure, and a decrease in heart rate were observed with dobutamine compared with baseline measurements. Arterial and mixed venous haemoglobin and oxygen content, as well as mixed venous partial pressure of oxygen increased. No significant changes in cardiac output, stroke volume, systemic vascular resistance, arterial partial pressure of oxygen, or oxygen consumption, delivery and extraction ratio were detected. Concluding, dobutamine increased systemic blood pressure without detectable changes in stroke volume, cardiac output or systemic vascular resistance in conscious horses.


Assuntos
Cardiotônicos/farmacologia , Fenômenos Fisiológicos Cardiovasculares/efeitos dos fármacos , Dobutamina/farmacologia , Cavalos/fisiologia , Consumo de Oxigênio/efeitos dos fármacos , Animais , Feminino , Masculino
9.
J Vet Intern Med ; 33(3): 1446-1455, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30938891

RESUMO

BACKGROUND: Noninvasive blood pressures (NIBP) and pulse pressures (PP) have not been published in horses with aortic and mitral regurgitation (AR or MR). OBJECTIVES: To investigate NIBP and PP in healthy Warmblood horses and horses with AR and MR and propose PP cutoffs to identify and stage AR severity. ANIMALS: Seventy-three Warmblood horses (healthy, 10; AR, 31; MR, 32). METHODS: Retrospective study. All horses had NIBP and an echocardiogram recorded. Cases were categorized based on severity of regurgitation. Pulse pressures were compared among healthy, MR, and AR groups and among AR severity groups. Cutoffs were determined by receiver operating characteristic curve analyses. RESULTS: Horses with AR had higher PP than horses with MR (mean difference [95% confidence interval (CI)], +17 [9-26] mm Hg, P < .001) and controls (+17 [5-30] mm Hg; P =.004). Horses with severe AR had higher PP compared those with mild (+38 [20-54] mm Hg; P < 0.001) and moderate AR (+33 [18-47] mm Hg; P < .001). The PP cutoffs to distinguish AR from MR and controls were 38 mm Hg (sensitivity [Sn], 100%; specificity [Sp], 19%) for maximal Sn and 61 mm Hg (Sn, 43%; Sp, 100%) for maximal Sp. The PP cutoffs to distinguish severe AR from mild and moderate AR were 57 mm Hg (Sn, 100%; Sp, 70%) for maximal Sn and 77 mm Hg (Sn, 75%; Sp, 100%) for maximal Sp. CONCLUSIONS AND CLINICAL IMPORTANCE: Horses with AR have increased PP. Noninvasive PP measurements interpreted with provided cutoffs may aid clinicians in diagnosing and staging severity of AR in horses.


Assuntos
Insuficiência da Valva Aórtica/veterinária , Pressão Sanguínea/fisiologia , Doenças dos Cavalos/diagnóstico , Insuficiência da Valva Mitral/veterinária , Animais , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia/veterinária , Feminino , Doenças dos Cavalos/diagnóstico por imagem , Cavalos , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/diagnóstico por imagem , Estudos Retrospectivos
10.
Vet Clin North Am Equine Pract ; 35(1): 43-64, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30826106

RESUMO

This article provides an overview on the principles of transthoracic echocardiography in horses. Indications for echocardiography, equipment, and technical considerations are discussed and a systematic approach for a complete echocardiographic examination in horses is described. Methods for assessment of chamber dimensions, allometric scaling of measurements, assessment of systolic and diastolic ventricular function, assessment of atrial function, hemodynamic assessment, and evaluation of valvular regurgitation are explained, focusing on traditional 2-dimensional (2D), motion-mode, and Doppler echocardiographic methods. Selected applications of newer echocardiographic methods, such as tissue Doppler imaging and 2D speckle tracking are also described.


Assuntos
Arritmias Cardíacas/veterinária , Ecocardiografia/veterinária , Doenças dos Cavalos/diagnóstico por imagem , Animais , Arritmias Cardíacas/diagnóstico por imagem , Ecocardiografia/métodos , Cavalos
11.
J Vet Intern Med ; 33(1): 212-224, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30520119

RESUMO

BACKGROUND: Little is known about normal heart rate variability (HRV) in horses during exercise. It can be difficult to separate premature beats from normal beat-to-beat variation at higher heart rates. OBJECTIVES: The aim was to quantify HRV in healthy horses during a high-speed treadmill-standardized exercise test (HSET) and to compare with the HRV in horses observed to have arrhythmias during exercise. ANIMALS: Thirteen healthy horses (Group H), 30 horses with arrhythmias (Group A), and 11 horses with poor performance but no observed arrhythmias (Group O). METHODS: Prospective, observational study. All horses performed a HSET with simultaneous electrocardiograph (ECG) recorded. The ECGs were corrected for artifacts, and arrhythmias noted. Percent instantaneous beat-to-beat cycle length variation (% R-R variation) was calculated, and HRV analyses were performed on trot, canter, and recovery segments. RESULTS: Group H showed between -4.4 and +3.8% R-R variation during trot and between -6.1 and +5.4% R-R variation during the canter phase of the HSET. Group A had significantly larger maximum and 1st percentile R-R shortening and lengthening compared with Group H and Group O during the recovery phase where most arrhythmias were observed. During recovery, a cutoff of 6% maximum % R-R shortening predicted the presence of arrhythmia with 88% sensitivity and 97% specificity and likelihood ratio of 26. CONCLUSIONS AND CLINICAL IMPORTANCE: Healthy horses have little instantaneous R-R variation during exercise. If a cardiac cycle shortens more than 6% from the previous cycle during the recovery phase, this R-R interval is likely to represent an arrhythmic event.


Assuntos
Arritmias Cardíacas/veterinária , Teste de Esforço/veterinária , Frequência Cardíaca/fisiologia , Doenças dos Cavalos/diagnóstico , Animais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Estudos de Casos e Controles , Feminino , Doenças dos Cavalos/fisiopatologia , Cavalos/fisiologia , Masculino
12.
Int J Cardiol ; 268: 179-186, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30047409

RESUMO

AIMS: Hyperglycaemia-induced reactive oxygen species (ROS) are key mediators of cardiac dysfunction. Intensive glycaemic control (IGC) has failed to reduce risk of heart failure in patients with diabetes but the underlying mechanisms remain to be elucidated. The present study investigates whether epigenetic regulation of the pro-oxidant adaptor p66Shc contributes to persistent myocardial dysfunction despite IGC. METHODS AND RESULTS: p66Shc expression was increased in the heart of diabetic mice, and 3-week IGC by slow-release insulin implants did not revert this phenomenon. Sustained p66Shc upregulation was associated with oxidative stress, myocardial inflammation and left ventricular dysfunction, as assessed by conventional and 2D speckle-tracking echocardiography. In vivo gene silencing of p66Shc, performed during IGC, inhibited ROS production and restored cardiac function. Furthermore, we show that dysregulation of methyltransferase DNMT3b and deacetylase SIRT1 causes CpG demethylation and histone 3 acetylation on p66Shc promoter, leading to persistent transcription of the adaptor. Altered DNMT3b/SIRT1 axis in the diabetic heart was explained by upregulation of miR-218 and miR-34a. Indeed, in human cardiomyocytes exposed to high glucose, inhibition of these miRNAs restored the expression of DNMT3b and SIRT1 and erased the adverse epigenetic signatures on p66Shc promoter. Consistently, reprogramming miR-218 and miR-34a attenuated persistent p66Shc expression and ROS generation. CONCLUSIONS: In diabetic left ventricular dysfunction, a complex epigenetic mechanism linking miRNAs and chromatin modifying enzymes drives persistent p66Shc transcription and ROS generation. Our results set the stage for pharmacological targeting of epigenetic networks to alleviate the clinical burden of diabetic cardiomyopathy.


Assuntos
Diabetes Mellitus Experimental/metabolismo , Epigênese Genética/fisiologia , Hiperglicemia/metabolismo , Proteína 1 de Transformação que Contém Domínio 2 de Homologia de Src/biossíntese , Disfunção Ventricular Esquerda/metabolismo , Animais , Diabetes Mellitus Experimental/genética , Hiperglicemia/genética , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Espécies Reativas de Oxigênio/metabolismo , Proteína 1 de Transformação que Contém Domínio 2 de Homologia de Src/deficiência , Disfunção Ventricular Esquerda/genética
13.
J Heart Valve Dis ; 25(3): 380-388, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27989051

RESUMO

BACKGROUND AND AIM OF THE STUDY: Bioengineered living autologous valves with remodeling and growth capacity represent a promising concept for future cardiac and venous valve repair. A meticulous understanding of the mechanisms involved in recellularization and remodeling is essential for the safe and efficient clinical translation of this technology. In this context, the first investigations of bioengineered vascular grafts in immune-incompetent or transgenic rodents represented an important step. However, the in-vivo assessment of bioengineered synthetic scaffold-based (biodegradable) valve replacements in rodent models has not been achieved to date. METHODS: Miniaturized monocuspid PGA (polyglycolic acid)-P4HB (poly-4-hydroxybutyrate)-based valves were created, incorporated into metallic stents (length 2.0 mm, diameter 1.1 mm) and introduced into catheter-based implantation devices. Wistar outbred rats (n = 8) underwent a laparotomy, abdominal aorta arteriotomy and valve delivery into the abdominal aorta. Valve placement and function were evaluated following deployment using ultrasound (Doppler- and M-mode). Explanted tissues were analyzed both macroscopically and histopathologically. RESULTS: No significant physiological or hemodynamic changes were observed, including heart rate, pressure gradients, velocity values and cardiac output before and after valve implantation. The cross-sectional area at the level of the stented valve was reduced by 22%. Valvular leaflet oscillation was observed in two animals, and thrombus formation in the stent was observed in one animal. Histological evaluation revealed cellular infiltration within 3 h in vivo, and no signs of thrombus deposition on the valvular surface. CONCLUSIONS: This study demonstrated the technical feasibility of the transcatheter implantation of bioengineered stented miniaturized valves into the infrarenal rat aorta, without affecting the animal's physiological and hemodynamic variables and with valvular oscillation in part of the implants. These results could serve as a basis for the implementation of a chronic rat in-vivo model for mechanistic studies in bioengineered valvular tissues under systemic hemodynamic conditions. Video 1: 2D ultrasonographic projection revealing graft's leaflet oscillation.


Assuntos
Aorta Abdominal/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Ácido Poliglicólico/química , Polímeros/química , Stents , Engenharia Tecidual/métodos , Animais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Estudos de Viabilidade , Hemodinâmica , Teste de Materiais , Metais/química , Modelos Animais , Desenho de Prótese , Ratos Wistar , Fatores de Tempo , Ultrassonografia Doppler em Cores
14.
J Vet Emerg Crit Care (San Antonio) ; 26(5): 691-703, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27599160

RESUMO

OBJECTIVES: To assess the measurement reliability of rotational thromboelastometry (ROTEM) measurements in horses, establish reference intervals for healthy horses, and evaluate the relationship between ROTEM variables, hematologic variables, and standard coagulation tests. DESIGN: Prospective observational study. SETTING: University teaching hospital. ANIMALS: Fifty healthy and 10 diseased adult horses. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Blood was sampled from 10 healthy and 10 diseased horses and samples were repeatedly analyzed to evaluate measurement reliability of various ROTEM variables. Four different ROTEM assays (ie, EXTEM, INTEM, FIBTEM, and APTEM) were run simultaneously under standardized conditions. The device-related, operator-related, and day-to-day variability for the majority of ROTEM variables was very low to low, as indicated by a coefficient of variation (CV) of < 15%. Most of test-retest variability of ROTEM variables appeared to be device-related. Blood samples from 50 clinically healthy horses were used to establish reference intervals for ROTEM variables. Multiple stepwise regression analyses identified associations of different ROTEM variables with hematocrit, total protein concentration, fibrinogen concentration, platelet count, prothrombin time, activated partial thromboplastin time, and thrombin time. CONCLUSIONS: ROTEM is a feasible method to evaluate coagulation in horses. Its measurement reliability is acceptable, but device-related measurement variability has to be considered. Reference intervals are presented, but the influence of hematocrit, platelet count, and fibrinogen concentration may need to be taken into account when interpreting individual test results.


Assuntos
Testes de Coagulação Sanguínea/veterinária , Tromboelastografia/veterinária , Animais , Coagulação Sanguínea , Testes de Coagulação Sanguínea/métodos , Feminino , Fibrinogênio/metabolismo , Hemorragia/diagnóstico , Hemorragia/veterinária , Doenças dos Cavalos/sangue , Doenças dos Cavalos/diagnóstico , Cavalos , Masculino , Tempo de Tromboplastina Parcial , Contagem de Plaquetas , Estudos Prospectivos , Tempo de Protrombina , Valores de Referência , Reprodutibilidade dos Testes , Tromboelastografia/métodos
15.
J Vet Emerg Crit Care (San Antonio) ; 26(5): 682-90, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27508527

RESUMO

OBJECTIVE: To assess the accuracy and reliability of a point-of-care (POC) triglyceride analyzer and to establish reference intervals for blood ([TRIG]POC/WB ) and plasma triglyceride concentrations ([TRIG]POC/PL ) in horses, ponies, and donkeys. DESIGN: Prospective study. SETTING: University teaching hospital. ANIMALS: 120 adult healthy equids (78 horses and ponies, 42 donkeys) and 79 equids suffering from hypertriglyceridemia (73 horses and ponies, 6 donkeys). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: [TRIG]POC/WB and [TRIG]POC/PL were measured using a POC analyzer and plasma triglyceride concentrations were measured using a standard laboratory assay ([TRIG]LAB/PL ). Reference intervals were determined. Test accuracy was assessed by Bland-Altman comparison of POC measurements with standard laboratory measurements and by evaluating linearity of dilutional series. Test reliability was assessed by repeated serial measurements. [TRIG]POC/WB and [TRIG]POC/PL were below the analytic range of the POC assay (<0.8 mmol/L [<70 mg/dL]) in healthy horses and ponies, whereas the reference intervals were 0.82-3.14 mmol/L (73-278 mg/dL) and 0.87-3.02 mmol/L (77-267 mg/dL), respectively, in donkeys. The POC analyzer systematically overestimated triglyceride concentrations when compared to a standard laboratory assay. The difference between [TRIG]POC/WB and [TRIG]POC/PL was small and clinically negligible. The coefficient of variation of repeated measures performed on the POC analyzer was below 10% for [TRIG]POC/WB and [TRIG]POC/PL , both in horses and donkeys and at all concentration ranges. CONCLUSIONS: The POC analyzer allows accurate and reliable measurement of [TRIG]POC/WB and [TRIG]POC/PL in horses, ponies, and donkeys in clinical settings. Assay-specific reference intervals should be determined for diagnosis and clinical monitoring of hypertriglyceridemia in equids.


Assuntos
Análise Química do Sangue/veterinária , Cavalos/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Triglicerídeos/sangue , Animais , Feminino , Doenças dos Cavalos/sangue , Hipertrigliceridemia/sangue , Hipertrigliceridemia/veterinária , Masculino , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes
16.
J Cardiovasc Pharmacol ; 68(5): 356-373, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27525575

RESUMO

This study focuses on characterization of the cardiac N-methyl D-aspartate receptors (NMDARs) as a target for endogenous and synthetic agonists and antagonists. Using isolated perfused rat hearts, we have shown that intracoronary administration of the NMDAR agonists and antagonists has a pronounced effect on autonomous heart function. Perfusion of rat hearts with autologous blood supplemented with NMDAR agonists was associated with induction of tachycardia, sinus arrhythmia, and ischemia occurring within physiological plasma concentration range for glutamate and glycine. Intracoronary administration of the NMDAR antagonists exerted an antiarrhythmic effect and resulted in bradycardia and improvement of capillary perfusion. Action of antagonists eliprodil, Ro25-6981, memantine, ketamine, and MK-801 on autonomous heart function diverged strikingly from that of L-type Ca channel blockers. Cardiac NMDAR subunit composition differed from that of neuronal receptors and was age specific and chamber specific. Transcripts of the GluN3A and GluN2D were found in all heart chambers, whereas expression of GluN1 and GluN2A and 2C was restricted to the atria. Expression of the GluN2B protein in ventricles increased markedly with age of the animals. The obtained data reveal that NMDARs are expressed in rat heart contributing to the autonomic heart rate regulation and the function of the cardiac conduction system.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Agonistas de Aminoácidos Excitatórios/administração & dosagem , Antagonistas de Aminoácidos Excitatórios/administração & dosagem , Miócitos Cardíacos/efeitos dos fármacos , Receptores de N-Metil-D-Aspartato/agonistas , Receptores de N-Metil-D-Aspartato/antagonistas & inibidores , Animais , Feminino , Coração/efeitos dos fármacos , Humanos , Masculino , Miócitos Cardíacos/metabolismo , Técnicas de Cultura de Órgãos , Ratos , Ratos Wistar , Receptores de N-Metil-D-Aspartato/metabolismo
17.
Eur Surg Res ; 57(3-4): 171-185, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27434273

RESUMO

BACKGROUND: Heterotopic heart transplantation (HHT) in rodent animal models represents an important technique enabling studies on organ transplantation immunology and pharmaceutical development. Recent investigations used nonworking HHT designs, with the left ventricle (LV) bypassed in the anastomosis system. In spite of their principal success, the lack of orthogonal ventricular filling leads to myocardial atrophy. However, when focusing on the cellular and molecular mechanisms involved in the in vivo remodeling of the myocardium or cell-based cardiovascular implants, a nonworking model is suboptimal as it lacks the native-analogous hemodynamic and metabolic situation. Here we present the hemodynamic and electrical assessment of a biventricularly loaded murine HHT method without the need for a combined heart-lung transplantation approach. METHODS: Heterotopic transplantations (n = 13) were performed on C57BL/6J-(H-2b) inbred mice (n = 13 donors, n = 13 recipients) by creating end-to-side anastomoses between the donors' cranial vena cava (CrVC) and the recipients' abdominal caudal vena cava (CVC), between the donors' ascending aorta and the recipients' abdominal aorta (aAo), and between the grafts' pulmonary trunk and the left atrium. After transplantation, a hemodynamic assessment using echocardiography (including 2D speckle tracking analysis) and electrocardiography was performed. RESULTS: The loaded HHT procedure in the mice was performed with an overall success rate of 61%. In 3 of the remaining 5 cases, only atrial function was restored. The median duration of the entire surgical procedure for the recipient animal was 190 (IQR 180-250) min. The mean heart rate in the loaded HHT group was 355 ± 6 bpm in comparison to the control group with an in situ heart rate of 418 ± 61 bpm. A native-like closing and opening pattern of the aortic and mitral valves (visible on both 2D and M-mode images) was observed, confirming a native-analogous loading of the LV. Pulsed-wave Doppler provided visualization of the flow across the region of anastomoses between the pulmonary trunk and the left atrium, reaching a mean maximum velocity of 382 ± 12 mm/s. Exemplary 2D speckle tracking analysis of the LV free wall and interventricular septum revealed some differences in vector directions in one animal when compared to the orthotopic native heart, indicating an asynchronous movement of the LV. CONCLUSIONS: These results demonstrate the technical (micro)surgical feasibility of a fully loaded HHT procedure in the murine model without using a combined heart-lung transplantation approach. The acute hemodynamic performance of the HHT grafts approximated the native orthotopic situation. This model may open up new options for the investigation of cellular and molecular questions in the murine cardiovascular in vivo system in the near future.


Assuntos
Transplante de Coração/métodos , Hemodinâmica , Transplante Heterotópico/métodos , Anastomose Cirúrgica , Animais , Ecocardiografia , Feminino , Ventrículos do Coração , Camundongos , Camundongos Endogâmicos C57BL , Modelos Animais
18.
Vet Clin North Am Food Anim Pract ; 32(1): 37-54, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26922111

RESUMO

Congenital heart disease should be considered when evaluating calves with chronic respiratory signs, failure to thrive, poor growth, or if a murmur is heard on physical examination. Echocardiography is currently the gold standard for diagnosing congenital heart defects. A wide variety of defects, either alone or in combination with a ventricular septal defect, are possible. A standardized approach using sequential segmental analysis is required to fully appreciate the nature and severity of more complex malformations. The prognosis for survival varies from guarded to poor and depends on the hemodynamic relevance of the defects and the degree of cardiac compensation.


Assuntos
Doenças dos Bovinos/diagnóstico por imagem , Cardiopatias Congênitas/veterinária , Comunicação Interventricular/veterinária , Animais , Animais Recém-Nascidos , Bovinos , Ecocardiografia/veterinária , Cardiopatias Congênitas/diagnóstico por imagem , Comunicação Interventricular/diagnóstico por imagem
19.
Can Vet J ; 57(1): 70-5, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26740702

RESUMO

Five horses were presented for treatment of atrial fibrillation by transvenous electrical cardioversion (TVEC). A dexmedetomidine infusion was administered for sedation during positioning of the cardioversion catheters, and continued during general anesthesia. Shocks were applied until return to sinus rhythm. Dexmedetomidine infusion provided excellent conditions for TVEC catheter placement and procedure.


Utilisation d'une perfusion continue de dexmedetomidine lors de cardioversion électrique transveineuse chez le cheval: une série de cas. Cinq chevaux présentant une fibrillation atriale ont été traités par cardioversion éléctrique transveineuse (TVEC). Pour le positionnement des cathéters de cardioversion, les chevaux ont reçu une perfusion de dexmédétomidine, poursuivie pendant l'anesthésie générale. Les chocs éléctriques sont répétés jusqu'au retour en rythme sinusal. La perfusion de dexmédétomidine a fourni d'excellentes conditions pour le positionnement des cathéters et la procédure de TVEC.(Traduit par les auteurs).


Assuntos
Fibrilação Atrial/veterinária , Dexmedetomidina/farmacologia , Cardioversão Elétrica/veterinária , Doenças dos Cavalos/terapia , Hipnóticos e Sedativos/farmacologia , Animais , Fibrilação Atrial/terapia , Dexmedetomidina/administração & dosagem , Esquema de Medicação , Feminino , Cavalos , Hipnóticos e Sedativos/administração & dosagem , Injeções Intravenosas , Masculino
20.
Vet Anaesth Analg ; 43(2): 153-62, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26095722

RESUMO

OBJECTIVE: To evaluate the non-calibrated, minimally invasive cardiac output (CO) monitor FloTrac/Vigileo (FloTrac) against thermodilution (TD) CO in standing horses. STUDY DESIGN: Prospective, experimental trial. ANIMALS: Nine adult horses weighing a median (range) of 535 (470-602) kg. METHODS: Catheters were placed in the right atrium, pulmonary artery and carotid artery under local anaesthesia. CO was measured 147 times by TD and FloTrac and indexed to body weight. Changes in CO were achieved with romifidine or xylazine and dobutamine constant rate infusions. Bland-Altman analysis, concordance and polar plot analysis were used to assess agreement and ability to track changes in CO. RESULTS: Mean ± standard deviation COTD of 48 ± 16 mL kg(-1) minute(-1) (range: 19-93 mL kg(-1) minute(-1) ) and mean COF loTrac of 9 ± 3 mL kg(-1) minute(-1) (range: 5-21 mL kg(-1) minute(-1) ) were measured. Low agreement with a large mean bias of 39 mL kg(-1) minute(-1) and wide limits of agreement of 8-70 mL kg(-1) minute(-1) were found. The percentage error of 108% and precision of TD of ± 18% resulted in an estimated precision of FloTrac of ± 106%. Comparison of changes in COF loTrac with changes in COTD gave a concordance rate of 52% in the four-quadrant plot, and a mean polar angle of -11° with radial limits of agreement of ± 61 ° in the polar plot. Mean arterial pressure (MAP) and COF loTrac were positively correlated (r = 0.5, p < 0.0001). No correlation of MAP with COTD was observed. CONCLUSIONS AND CLINICAL RELEVANCE: The FloTrac system, originally designed for use in humans, neither measured absolute CO in standing horses accurately nor tracked relative changes in CO measured by TD correctly. The false dependence of COF loTrac on arterial blood pressure further discourages the use of this technique in horses.


Assuntos
Anestesia/veterinária , Débito Cardíaco , Testes de Função Cardíaca/veterinária , Cavalos , Monitorização Fisiológica/veterinária , Agonistas de Receptores Adrenérgicos alfa 2/administração & dosagem , Agonistas de Receptores Adrenérgicos beta 1/administração & dosagem , Anestésicos/administração & dosagem , Animais , Pressão Sanguínea , Calibragem , Dobutamina/administração & dosagem , Feminino , Testes de Função Cardíaca/instrumentação , Imidazóis/administração & dosagem , Masculino , Monitorização Fisiológica/métodos , Termodiluição , Xilazina/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA