RESUMO
Soft colloids are widely used to study glass transition, aging and jamming. A high size polydispersity is typically introduced in these systems to avoid crystal formation. Here, we use binary mixtures of hollow and regular microgels with comparable sizes to inhibit crystallization. The phase behavior of the mixture is probed as a function of the number fraction of hollow microgels and characterized by small-angle X-ray scattering. Molecular dynamic simulations are used to extract the particle-particle pair potential and obtain insight on their deformation. The results suggest that the high deformability of the hollow microgels offers an alternative route to maximize the entropy without crystal formation.
RESUMO
BACKGROUND: Raphe-type bicuspid aortic valve (BAV) is a potential hostile scenario in trans-catheter aortic valve replacement (TAVR) due to pronounced calcium burden, possibly associated with tapered valve configuration. Trans-Catheter heart valve (THV) sizing strategy (annular vs. supra-annular) is controversial in this valve subtype. OBJECTIVES: To describe the phenotypical characteristics of severe, tapered, raphe-type, BAV stenosis undergoing TAVR and to explore safety and efficacy of modern-generation THVs, analysing the impact of annular and supra-annular sizing strategies on short- and mid-terms outcomes. METHODS: This is a retrospective, multicenter registry enrolling consecutive stenotic Sievers type 1 BAV treated with TAVR. Study population was divided into tapered and non-tapered configuration according to MSCT analysis. Matched comparison between annular and supra-annular sizing groups was performed in tapered population. RESULTS: From January 2016 to June 2023, 897 patients were enrolled. Of them, 696 patients displayed a tapered configuration. Of those, 510 received a THV according to annular sizing. After propensity score matching 186 matched pairs were selected. Technical success (96.2 % vs 94.1 %, OR 1.61 [0.61-4.24], p = 0.34), 30-day device success (83.6 % in both groups, OR 1.42 [0.78-2.57], p = 0.25) and 30-day early safety (71.8 % vs 70.5 %, OR 1.07 [0.68-1.68], p = 0.78) were similar between the annular and supra-annular sizing groups; a higher post-TAVR gradient was observed in supra-annular group, although it was only 2 mmHg mean. At mid-term follow-up, the rate of clinical efficacy was 84.7 %. CONCLUSIONS: TAVR with modern-generation devices is safe and effective for tapered raphe-type BAV, showing comparable results for annular and supra-annular sizing strategies.
Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Idoso , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Idoso de 80 Anos ou mais , Resultado do Tratamento , Desenho de Prótese , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , SeguimentosRESUMO
BACKGROUND: Transcatheter tricuspid valve intervention (TTVI) has been increasingly adopted in recent years for the treatment of patients with tricuspid regurgitation (TR). However, no dedicated risk stratification has been established for patients undergoing TTVI. OBJECTIVES: The aim of the present study was to propose a dedicated risk score for patients affected by severe TR undergoing TTVI. METHODS: The score was derived from the TRIVALVE (International Multisite Transcatheter Tricuspid Valve Therapies Registry; NCT03416166) registry, according to data availability. A stepwise model approach was used on predictor variables to develop a scoring system for predicting 12-month mortality or rehospitalization using multivariable logistic regression. Internal discrimination, calibration, and validation were assessed using receiver-operating characteristic curve analysis and bootstrapping with 1,000 resamples. RESULTS: A total of 483 patients were included in the study, with an overall 12-month mortality or rehospitalization rate of 19% (n = 94). The final risk score, ranging from 0 to 4.5, included the following 5 parameters (adjusted for age and gender): 1) atrial fibrillation at baseline; 2) glomerular filtration rate <30 mL/min; 3) elevated gamma-glutamyl transferase/bilirubin levels; 4) signs of right heart failure; and 5) left ventricular ejection fraction <50%. The bias-corrected area under the receiver-operating characteristic curve was 68% (95% CI: 62%-75%). A cutoff value of 2.5 demonstrated sensitivity of 65.4% and specificity of 60.5% for the outcome. CONCLUSIONS: The present study proposes a dedicated risk score for patients undergoing TTVI, providing an additional and simple tool for heart teams to select the best therapy for patients affected by severe TR.
Assuntos
Cateterismo Cardíaco , Técnicas de Apoio para a Decisão , Implante de Prótese de Valva Cardíaca , Readmissão do Paciente , Valor Preditivo dos Testes , Sistema de Registros , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Medição de Risco , Masculino , Feminino , Fatores de Risco , Idoso , Valva Tricúspide/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/instrumentação , Fatores de Tempo , Idoso de 80 Anos ou mais , Resultado do Tratamento , Reprodutibilidade dos Testes , Tomada de Decisão Clínica , Pessoa de Meia-IdadeRESUMO
BACKGROUND: Patients with mitral regurgitation (MR) and morphologic presence of relevant mitral annular calcification (MAC) represent a challenging phenotypic subset with limited treatment options. OBJECTIVES: The aim of this study was to assess the feasibility of transcatheter mitral valve replacement (TMVR) using dedicated devices for the treatment of MAC patients. METHODS: Consecutive patients with symptomatic MR receiving TMVR and with available computed tomography data from the CHOICE-MI (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency) multicenter registry were stratified by the presence of none or mild mitral annular calcification (MACnone/mild) vs moderate or severe mitral annular calcification (MACmod/sev). RESULTS: Among 279 eligible patients (median age = 76.0 years [Q1-Q3: 71.0-81.0 years], EuroSCORE II = 6.2% [Q1-Q3: 3.9%-12.1%]), 222 (79.6%) presented with MACnone/mild and 57 (20.4%) with MACmod/sev. Patients with MACmod/sev had a higher prevalence of extracardiac arteriopathy (P = 0.011) and primary MR (P < 0.001). Although the technical success rate and the extent of MR elimination did not differ, TMVR treatment in MACmod/sev patients was associated with higher rates of postprocedural bleeding complications (P = 0.02) and renal failure (P < 0.001). Functional improvement at the 1- and 2-year follow-up did not differ between groups. At the 2-year follow-up, there were no differences between patients with MACmod/sev and MACnone/mild regarding all-cause mortality (38.5% vs 37.7%; P = 0.76), cardiovascular mortality (21.3% vs 24.9%; P = 0.97), and all-cause mortality or heart failure hospitalization (52.4% vs 46.7%; P = 0.28) CONCLUSIONS: TMVR in patients with MACmod/sev is associated with higher rates of postprocedural complications but similar rates of survival, MR resolution, and functional improvement compared to MACnone/mild. Further studies are necessary to define the role of dedicated TMVR devices in this population. (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency Registry [CHOICE-MI]; NCT04688190).
Assuntos
Calcinose , Cateterismo Cardíaco , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Humanos , Idoso , Masculino , Feminino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Idoso de 80 Anos ou mais , Fatores de Tempo , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Calcinose/mortalidade , Calcinose/fisiopatologia , Calcinose/terapia , Fatores de Risco , Índice de Gravidade de Doença , Europa (Continente)RESUMO
Background: Transcatheter mitral valve replacement (TMVR) represents a novel treatment option for patients with mitral regurgitation (MR), but little is known about the hemodynamic impact of MR elimination following TMVR. We sought to investigate the hemodynamic impact of TMVR on left ventricular (LV) and right ventricular (RV) function using noninvasive pressure-volume loops. Methods: All consecutive patients undergoing TMVR with dedicated devices between May 2016 and August 2022 were enrolled. The end-diastolic and end-systolic pressure-volume relationships were estimated from 26 patients using single-beat echocardiographic measurements at baseline and after TMVR at discharge. RV function was assessed by RV-pulmonary artery (PA) coupling and RV fractional area change. One-year follow-up was available for 19 patients. The prognostic impact of calculated end-diastolic volume at an end-diastolic pressure of 20 mmHg (VPed20) reduction was assessed by Cox regression. Results: A total of 26 patients (77.0 years [interquartile range 73.9-80.1], N = 17 [65.4%] male) with successful TMVR were included (secondary MR [N = 21, 80.8%]; median LV ejection fraction was 37.0% [interquartile range 30.7-50.7]). At discharge, a decrease in VPed20 (p < 0.001) indicating leftward shift of end-diastolic pressure-volume relationship, and an increase of the end-systolic elastance slope (p = 0.007) were observed after TMVR. No changes were observed for RV-PA coupling (p = 0.19) and RV fractional area change (p = 0.22). At 1-year follow-up, LV contractility (end-systolic elastance) and RV-PA coupling remained stable. Vped20 reduction at discharge was significantly associated with 1-year all-cause mortality or heart failure hospitalization (hazard ratio 0.16, 95% CI 0.04-0.71, p = 0.016). Conclusions: Noninvasive assessment of pressure-volume loops demonstrated early LV reverse remodeling and improved LV contractility, while RV performance was preserved. These results indicate the potential prognostic impact of complete MR elimination after TMVR.
RESUMO
Objective: Epicardial adipose tissue (EAT) is implicated in the pathogenesis and progression of coronary artery disease (CAD). Limited data exists on the interplay between EAT and atherosclerosis in young individuals. Our study aims to explore the relationship between EAT and CAD in a young cohort. Methods: All young (18-45 years) patients without prior CAD, referred for coronary computed tomography angiography (CCTA) from 2016 to 2022 were included. EAT volume and coronary artery calcium (CAC) were calculated from dedicated non-contrast scans. Coronary plaque presence, extent, and volume were quantified from CCTA. Multivariable logistic regression models for the presence of CAD, defined as any coronary atherosclerosis, were performed. Results: Overall, 712 patients (39±4.8 years, 54 % female) with 45 % Hispanic, and 21 % non-Hispanic Black were included. Patients with CAD had higher EAT volume than those without (80.80 mL ± 36.00 vs 55.16 mL ± 27.92; P < 0.001). In those with CAC=0, higher EAT was associated with the presence of CAD compared to lower EAT volume (P < 0.001). An EAT volume >76 mL was associated with higher CAC (P < 0.001), segment involvement score (P < 0.001), and quantitative total, non-calcified, and low-attenuation plaque volumes (P < 0.002). At multivariable analysis, EAT volume (per 10 mL, OR: 1.21; 95 %CI: 1.12-1.30; P < 0.0001) was independently associated with the presence of CAD. Conclusion: In a diverse cohort of young adults without history of CAD and undergoing a clinically indicated CCTA, EAT volume was independently associated with the presence of CAD. Our findings highlight EAT potential as a novel marker for CAD risk-assessment and a potential therapeutic target in young patients.
RESUMO
BACKGROUND: Data on procedural and early outcomes after transjugular transcatheter tricuspid valve replacement (TTVR) are limited. OBJECTIVES: This study sought to evaluate first-in-man procedural and clinical outcomes after transjugular TTVR with a special focus on patients who received large device sizes in whom TTVR outcomes have been questioned. METHODS: The retrospective registry included patients who underwent TTVR using the LuX-Valve Plus system (Jenscare Biotechnology Co Ltd) for symptomatic tricuspid regurgitation (TR) from January 2022 until February 2024 at 15 international centers in a compassionate use setting. The endpoints were procedural TR reduction, in-hospital death, adverse events, and 1-month survival. We further stratified results according to the size of the implanted device (<55 vs ≥55 mm). RESULTS: The registry included a total of 76 patients at a median age of 78 years (Q1-Q3: 72-83 years, 47.4% women). TR was reduced to ≤2+ and ≤1+ in 94.7% and 90.8% of patients (75.0% of patients received TTVR devices ≥55 mm) with well-sustained results at 1-month follow-up (TR ≤2+ in 95.0% and ≤1+ 86.8%). Residual TR was paravalvular in all cases. In-hospital death occurred in 4 patients (5.3%). Four patients (5.3%) underwent cardiac surgery during index hospitalization. Major in-hospital bleeding events occurred in 5 patients (6.6%). New in-hospital pacemaker implantation was required in 3.9% of patients in the overall cohort (5.7% in "pacemaker-naive" individuals). No cases of valve thrombosis, stroke, myocardial infarction, or pulmonary embolism were observed. At 1-month follow-up, survival was 94.4%, and NYHA functional class significantly improved. One further patient received a pacemaker, 1 further bleeding event occurred, and 2 patients underwent reintervention or surgery within the first 30 days after TTVR. No differences in procedural outcomes or adverse events were observed after stratification for valve size. CONCLUSIONS: Transjugular TTVR appears to be a safe and effective treatment option for patients with severe TR with comparable outcomes in very large tricuspid anatomies.
Assuntos
Cateterismo Cardíaco , Ensaios de Uso Compassivo , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Feminino , Masculino , Estudos Retrospectivos , Idoso , Resultado do Tratamento , Fatores de Tempo , Idoso de 80 Anos ou mais , Valva Tricúspide/cirurgia , Valva Tricúspide/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/mortalidade , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Fatores de Risco , Mortalidade Hospitalar , Complicações Pós-Operatórias/etiologia , Veias JugularesRESUMO
BACKGROUND: The off-label utilization of transcatheter heart valve (THV) devices for the treatment of inoperable or high-surgical risk patients with pure native aortic valve regurgitation (NAVR) has demonstrated suboptimal outcomes, both with self- and balloon-expandable (BE) devices. The aim of this study is to compare the use of different BE scaffolds in treating pure NAVR. METHODS: Consecutive patients with pure severe NAVR who were deemed to be at high-risk and were treated with last-generation BE-THVs among seventeen Centers in Europe and US. Technical and device success rates were the primary objectives. RESULTS: Between February 2018 and July 2023, among 144 patients, 41 (28 %) received a MyVal device and 103 (72 %) were treated with a Sapien THV. Patients treated with a MyVal THV had an extra-large annulus more frequently compared to the Sapien group (49%vs.20 %, p < 0.001). Technical and device success rates were 90 % and 81 %, respectively, p > 0.1. The rate of THV migration/embolization (MyVal 4.9%vs. Sapien 11 %, p = 0.4) and second valve needed (4.9%vs.7.8 %, p = 0.7) were numerically lower in the MyVal group, whereas the rate of at least moderate paravalvular leak (15%vs.7.8 %, p = 0.2) and permanent pacemaker implantation (25%vs.18 %, p = 0.16) were numerically higher in the Myval group. CONCLUSIONS: Off-label use of BE devices for pure NAVR represents a potential alternative in high-risk patients in the absence of dedicated devices. However, BE in NAVR is associated with suboptimal outcomes. The availability of larger THV sizes may introduce transcatheter aortic valve replacement as an effective treatment for patients traditionally deemed unsuitable. NON-STANDARD ABBREVIATIONS AND ACRONYMS: AR = aortic regurgitation, BE = balloon-expandable, NAVR = native aortic valve regurgitation, PM = pacemaker, TAVR = transcatheter aortic valve replacement, THV = transcatheter heart valve, TVEM = transcatheter valve embolization and migration, VARC-3 = Valve Academic Research Consortium 3.
RESUMO
Pulmonary embolism (PE) is a significant cause of cardiovascular mortality, with varying presentations and management challenges. Traditional treatment approaches often differ, particularly for submassive/intermediate-risk PEs, because of the lack of clear guidelines and comparative data on treatment efficacy. The introduction of pulmonary embolism response teams (PERTs) aims to standardize and improve outcomes in acute PE management through multidisciplinary collaboration. This review examines the conception, evolution, and operational mechanisms of PERTs while providing a critical analysis of their implementation and efficacy using retrospective trials and recent randomized trials. The study also explores the integration of advanced therapeutic devices and treatment protocols facilitated by PERTs. PERT programs have significantly influenced the management of both massive and submassive PEs, with notable improvements in clinical outcomes such as decreased mortality and reduced length of hospital stay. The utilization of advanced therapies, including catheter-directed thrombolysis and mechanical thrombectomy, has increased under PERT guidance. Evidence from various studies, including those from the National PERT Consortium, underscores the benefits of these multidisciplinary teams in managing complex PE cases, despite some studies showing no significant difference in mortality. PERT programs have demonstrated potentials to reduce morbidity and mortality, streamlining the use of healthcare resources and fostering a model of sustainable practice across medical centers. PERT program implementation appears to have improved PE treatment protocols and innovated advanced therapy options, which will be further refined as they are employed in clinical practice. The continued expansion of the capabilities of PERTs and the forthcoming results from ongoing randomized trials are expected to further define and optimize management protocols for acute PEs.
RESUMO
BACKGROUND: The impact of intraprocedural results following transcatheter edge-to-edge repair (TEER) in primary mitral regurgitation (MR) is controversial. OBJECTIVES: This study sought to investigate the prognostic impact of intraprocedural residual mitral regurgitation (rMR) and mean mitral valve gradient (MPG) in patients with primary MR undergoing TEER. METHODS: The PRIME-MR (Outcomes of Patients Treated With Mitral Transcatheter Edge-to-Edge Repair for Primary Mitral Regurgitation) registry included consecutive patients with primary MR undergoing TEER from 2008 to 2022 at 27 international sites. Clinical outcomes were assessed according to intraprocedural rMR and mean MPG. Patients were categorized according to rMR (optimal result: ≤1+, suboptimal result: ≥2+) and MPG (low gradient: ≤5 mm Hg, high gradient: > 5 mm Hg). The prognostic impact of rMR and MPG was evaluated in a Cox regression analysis. The primary endpoint was 2-year all-cause mortality or heart failure hospitalization. RESULTS: Intraprocedural rMR and mean MPG were available in 1,509 patients (median age = 82 years [Q1-Q3: 76.0-86.0 years], 55.1% male). Kaplan-Meier analysis according to rMR severity showed significant differences for the primary endpoint between rMR ≤1+ (29.1%), 2+ (41.7%), and ≥3+ (58.0%; P < 0.001), whereas there was no difference between patients with a low (32.4%) and high gradient (42.1%; P = 0.12). An optimal result/low gradient was achieved in most patients (n = 1,039). The worst outcomes were observed in patients with a suboptimal result/high gradient. After adjustment, rMR ≥2+ was independently linked to the primary endpoint (HR: 1.87; 95% CI: 1.32-2.65; P < 0.001), whereas MPG >5 mm Hg was not (HR: 0.78; 95% CI: 0.47-1.31; P = 0.35). CONCLUSIONS: Intraprocedural rMR but not MPG independently predicted clinical outcomes following TEER for primary MR. When performing TEER in primary MR, optimal MR reduction seems to outweigh the impact of high transvalvular gradients.
Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Hemodinâmica , Insuficiência da Valva Mitral , Valva Mitral , Recuperação de Função Fisiológica , Sistema de Registros , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Masculino , Feminino , Idoso , Resultado do Tratamento , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Fatores de Risco , Fatores de Tempo , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Medição de RiscoRESUMO
BACKGROUND: Residual transprosthetic gradient (TG) after transcatheter aortic valve replacement (TAVR) with balloon-expandable valves (BEV) may be due to suboptimal valve expansion. AIMS: To compare hemodynamics after TAVR with small BEV according to postdilation strategy. METHODS: This observational, retrospective cohort study included 184 consecutive patients from a single center treated with 23 mm Sapien 3 Ultra (Edwards Lifesciences) BEV implantation in the aortic position and enrolled between January 2020 and April 2023. Patients treated with routine postdilation (RP, n = 73) were compared to patients treated according to local standard practice (SP, n = 111). Primary endpoint was 30-day mean TG. Secondary endpoints were incidence of 30-day prosthesis-patient mismatch (PPM), technical success and device success. RESULTS: Thirty-day mean TG was lower in RP versus SP (12.3 ± 4.6 mmHg vs. 14.1 ± 5.7 mmHg, p = 0.031), and incidence of PPM was less common with RP versus SP (47.3% vs. 71.0%, p = 0.006). Technical success (98.6% vs. 99.1%, p = 0.637) and device success (93.1% vs. 90.1%, p = 0.330) did not differ between groups. Differences in 30-day mean TG were driven by patients at normal flow (12.1 ± 4.0 mmHg vs. 15.0 ± 5.5 mmHg, p = 0.014), while no differences were evident among patients at low flow (12.5 ± 5.5 mmHg vs. 11.7 ± 5.5 mmHg, p = 0.644). RP decreased height and increased width of BEV, and a linear regression established that final BEV width could predict 30-day mean TG (r = -0.6654, p < 0.0001). CONCLUSIONS: RP after TAVR with small BEV was associated with more favorable forward-flow hemodynamics than SP.
RESUMO
Current guidelines of aortic stenosis (AS) management focus on valve parameters, LV systolic dysfunction, and symptoms; however, emerging data suggest that there may be benefit of aortic valve replacement before it becomes severe by present criteria. Myocardial assessment using novel multimodality imaging techniques exhibits subclinical myocardial injury and remodeling at various stages before guideline-directed interventions, which predicts adverse outcomes. This raises the question of whether implementing serial myocardial assessment should become part of the standard appraisal, thereby identifying high-risk patients aiming to minimize adverse outcomes.
Assuntos
Estenose da Valva Aórtica , Imagem Multimodal , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Imagem Multimodal/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Miocárdio/patologia , Imagem Cinética por Ressonância Magnética/métodosRESUMO
BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.
Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Fatores de Risco , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Resultado do Tratamento , Idoso de 80 Anos ou mais , Incidência , Fatores de Tempo , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/fisiopatologia , Europa (Continente) , Medição de Risco , Desenho de Prótese , Razão de Chances , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/diagnóstico , Estudos RetrospectivosRESUMO
Inferior outcomes with ACURATE neo, a self-expanding transcatheter heart valve (THV) for the treatment of severe aortic stenosis, were mainly driven by higher rates of moderate/severe paravalvular leak (PVL). To overcome this limitation, the next-generation ACURATE neo2 features a 60% larger external sealing skirt. Data on long-term performance are limited; however, clinical evidence suggests improved short-term performance which is comparable to contemporary THVs. This report reviews data on short-term clinical and echocardiographic outcomes of ACURATE neo2. A PubMed search yielded 13 studies, including 5 single arm and 8 nonrandomized comparative studies with other THVs which reported in-hospital or 30-day clinical and echocardiographic outcomes. In-hospital or 30-day all-cause mortality was ≤3.3%, which is comparable to other contemporary THVs. The rates of postprocedural â§moderate PVL ranged 0.6%-4.7%. In multicenter propensity-matched analyses, neo2 significantly reduced the rate of â§moderate PVL compared to neo (3.5% vs. 11.3%, p < 0.01), whereas rates were comparable to Evolut Pro/Pro+ (Neo2: 2.0% vs. Pro/Pro+: 3.1%, p = 0.28) and SAPIEN 3 Ultra (Neo2: 0.6% vs. Ultra: 1.1%, p = 0.72). The rate of permanent pacemaker implantation with neo2 was consistently low (3.3%-8.6%) except in one study, and in propensity-matched analyses were significantly lower than Evolut Pro/Pro+ (6.7% vs. 16.7%, p < 0.01), and comparable to SAPIEN 3 Ultra (8.1% vs. 10.3%, p = 0.29). In conclusion, ACURATE neo2 showed better short-term performance by considerably reducing PVL compared to its predecessor, with short-term clinical and echocardiographic outcomes comparable to contemporary THVs.
RESUMO
BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.
Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Estudos Multicêntricos como Assunto , Sistema de RegistrosRESUMO
Deformable colloids and macromolecules adsorb at interfaces as they decrease the interfacial energy between the two media. The deformability, or softness, of these particles plays a pivotal role in the properties of the interface. In this study, we employ a comprehensive in situ approach, combining neutron reflectometry with molecular dynamics simulations, to thoroughly examine the profound influence of softness on the structure of microgel Langmuir monolayers under compression. Lateral compression of both hard and soft microgel particle monolayers induces substantial structural alterations, leading to an amplified protrusion of the microgels into the aqueous phase. However, a critical distinction emerges: hard microgels are pushed away from the interface, in stark contrast to the soft ones, which remain firmly anchored to it. Concurrently, on the air-exposed side of the monolayer, lateral compression induces a flattening of the surface of the hard monolayer. This phenomenon is not observed for the soft particles as the monolayer is already extremely flat even in the absence of compression. These findings significantly advance our understanding of the key role of softness on both the equilibrium phase behavior of the monolayer and its effect when soft colloids are used as stabilizers of responsive interfaces and emulsions.
RESUMO
Triglycerides play a crucial role in the efficient storage of energy in the body. Mild and moderate hypertriglyceridemia (HTG) is a heterogeneous disorder with significant association with atherosclerotic cardiovascular disease (ASCVD), including myocardial infarction, ischemic stroke, and peripheral artery disease and represents an important component of the residual ASCVD risk in statin treated patients despite optimal low-density lipoprotein cholesterol reduction. Individuals with severe HTG (>1,000 mg/dL) rarely develop atherosclerosis but have an incremental incidence of acute pancreatitis with significant morbidity and mortality. HTG can occur from a combination of genetic (both mono and polygenic) and environmental factors including poor diet, low physical activity, obesity, medications, and diseases like insulin resistance and other endocrine pathologies. HTG represents a potential target for ASCVD risk and pancreatitis risk reduction, however data on ASCVD reduction by treating HTG is still lacking and HTG-associated acute pancreatitis occurs too rarely to effectively demonstrate treatment benefit. In this review, we address the key aspects of HTG pathophysiology and examine the mechanisms and background of current and emerging therapies in the management of HTG.