1.
Int J Hyperthermia ; 40(1): 2283388, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37994800

RESUMO

Purpose: A crucial aspect of quality assurance in thermal therapy is periodic demonstration of the heating performance of the device. Existing methods estimate the specific absorption rate (SAR) from the temperature rise after a short power pulse, which yields a biased estimate as thermal diffusion broadens the apparent SAR pattern. To obtain an unbiased estimate, we propose a robust frequency-domain method that simultaneously identifies the SAR as well as the thermal dynamics.Methods: We propose a method consisting of periodic modulation of the FUS power while recording the response with MR thermometry (MRT). This approach enables unbiased measurements of spatial Fourier coefficients that encode the thermal response. These coefficients are substituted in a generic thermal model to simultaneously estimate the SAR, diffusivity, and damping. The method was tested using a cylindrical phantom and a 3 T clinical MR-HIFU system. Three scenarios with varying modulation strategies are chosen to challenge the method. The results are compared to the well-known power pulse technique.Results: The thermal diffusivity is estimated at 0.151 mm2s-1 with a standard deviation of 0.01 mm2s-1 between six experiments. The SAR estimates are consistent between all experiments and show an excellent signal-to-noise ratio (SNR) compared to the well established power pulse method. The frequency-domain method proved to be insensitive to B0-drift and non steady-state initial temperature distributions.Conclusion: The proposed frequency-domain estimation method shows a high SNR and provided reproducible estimates of the SAR and the corresponding thermal diffusivity. The findings suggest that frequency-domain tools can be highly effective at estimating the SAR from (biased) MRT data acquired during periodic power modulation.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Termometria , Difusão Térmica , Temperatura , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
2.
J Control Release ; 343: 798-812, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35134460

RESUMO

PURPOSE: Encapsulation of cytotoxic drugs for a localized release is an effective way to increase the therapeutic window of such agents. In this article we present the localized release of doxorubicin (DOX) from phosphatidyldiglycerol (DPPG2) based thermosensitive liposomes using MR-HIFU mediated hyperthermia in a swine model. MATERIALS AND METHODS: German landrace pigs of weights between 37.5 and 53.5 kg received a 30-min infusion of DOX containing thermosensitive liposomes (50 mg DOX/m2). The pigs' biceps femoris was treated locally in two separate target areas with mild hyperthermia using magnetic resonance guided high intensity focused ultrasound, starting 10 min and 60 min after initiation of the infusion, respectively. The pharmacokinetics and biodistribution of DOX were determined and an analysis of the treatment parameters' influence was performed. RESULTS: Compared to untreated tissue, we found a 15-fold and a 7-fold increase in DOX concentration in the muscle volumes that had undergone hyperthermia starting 10 min and 60 min after the beginning of the infusion, respectively. The pharmacokinetic analysis showed a prolonged circulation time of DOX and a correlation between the AUC of extra-liposomal DOX in the bloodstream and the amount of DOX accumulated in the target tissue. CONCLUSIONS: We have demonstrated a workflow for MR-HIFU hyperthermia drug delivery that can be adapted to a clinical setting, showing that HIFU-hyperthermia is a suitable method for local drug release of DOX using DPPG2 based thermosensitive liposomes in stationary targets. Using the developed pharmacokinetic model, an optimization of the drug quantity deposited in the target via the timing of infusion and hyperthermia should be possible.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Hipertermia Induzida , Animais , Antibióticos Antineoplásicos , Doxorrubicina , Sistemas de Liberação de Medicamentos/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Hipertermia Induzida/métodos , Lipossomos , Suínos , Distribuição Tecidual
3.
Int J Hyperthermia ; 38(1): 1174-1187, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34374624

RESUMO

PURPOSE: This article will report results from the in-vivo application of a previously published model-predictive control algorithm for MR-HIFU hyperthermia. The purpose of the investigation was to test the controller's in-vivo performance and behavior in the presence of heterogeneous perfusion. MATERIALS AND METHODS: Hyperthermia at 42°C was induced and maintained for up to 30 min in a circular section of a thermometry slice in the biceps femoris of German landrace pigs (n=5) using a commercial MR-HIFU system and a recently developed MPC algorithm. The heating power allocation was correlated with heat sink maps and contrast-enhanced MRI images. The temporal change in perfusion was estimated based on the power required to maintain hyperthermia. RESULTS: The controller performed well throughout the treatments with an absolute average tracking error of 0.27 ± 0.15 °C and an average difference of 1.25 ± 0.22 °C between T10 and T90. The MPC algorithm allocates additional heating power to sub-volumes with elevated heat sink effects, which are colocalized with blood vessels visible on contrast-enhanced MRI. The perfusion appeared to have increased by at least a factor of ∼1.86 on average. CONCLUSIONS: The MPC controller generates temperature distributions with a narrow spectrum of voxel temperatures inside the target ROI despite the presence of spatiotemporally heterogeneous perfusion due to the rapid thermometry feedback available with MR-HIFU and the flexible allocation of heating power. The visualization of spatiotemporally heterogeneous perfusion presents new research opportunities for the investigation of stimulated perfusion in hypoxic tumor regions.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Hipertermia Induzida , Algoritmos , Animais , Hipertermia , Imageamento por Ressonância Magnética , Perfusão , Suínos
4.
Int J Hyperthermia ; 37(1): 786-798, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32619373

RESUMO

Purpose: Pancreatic cancer is typically diagnosed in a late stage with limited therapeutic options. For those patients, ultrasound-guided high-intensity focused ultrasound (US-HIFU) can improve local control and alleviate pain. However, MRI-guided HIFU (MR-HIFU) has not yet been studied extensively in this context. To facilitate related research and accelerate clinical translation, we report a workflow for the in vivo HIFU ablation of the porcine pancreas under MRI guidance.Materials and methods: The pancreases of five healthy German landrace pigs (35-58 kg) were sonicated using a clinical MR-HIFU system. Acoustic access to the pancreas was supported by a specialized diet and a hydrogel compression device for bowel displacement. Organ motion was suspended using periods of apnea. The size of the resulting thermal lesions was assessed using the thermal threshold- and dose profiles, non-perfused volume, and gross examination. The effect of the compression device on beam path length was assessed using MRI imaging.Results: Eight of ten treatments resulted in clearly visible damage in the target tissue upon gross examination. Five treatments resulted in coagulative necrosis. Good agreement between the four metrics for lesion size and a clear correlation between the delivered energy dose and the resulting lesion size were found. The compression device notably shortened the intra-abdominal beam path.Conclusions: We demonstrated a workflow for HIFU treatment of the porcine pancreas in-vivo under MRI-guidance. This development bears significance for the development of MR-guided HIFU interventions on the pancreas as the pig is the preferred animal model for the translation of pre-clinical research into clinical application.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Imagem por Ressonância Magnética Intervencionista , Animais , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Suínos
SELEÇÃO DE REFERÊNCIAS