Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Ultrasound ; 2024 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-38402484

RESUMO

Bowel obstruction (BO) in children has a wide differential diagnosis, ranging from non-urgent conditions to surgical emergencies. Abdominal radiographs are most often used as the first imaging modality for the evaluation of obstruction. However, for some indications, ultrasound can be the primary imaging modality. Therefore, it is incumbent on radiologists to recognize the types of bowel obstruction that can be recognized with US. Key sonographic features of BO include differential dilation of bowel loops, bowel wall thickening, and free fluid. "Do Not Miss" findings that indicate need for emergent treatment include volvulus, pneumoperitoneum, and/or signs of ischemia (bowel wall thinning and/or absent perfusion). The aim of this pictorial essay is to provide guidance on the sonographic technique and findings that enable identification of BO on US. Examples of neonatal BO on US, including common and less frequently encountered etiologies, are illustrated in this pictorial essay.

2.
Eur J Pediatr ; 182(11): 5159-5165, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37698612

RESUMO

The combination of low dose CT and AI performance in the pediatric population has not been explored. Understanding this relationship is relevant for pediatric patients given the potential radiation risks. Here, the objective was to determine the diagnostic performance of commercially available Computer Aided Detection (CAD) for pulmonary nodules in pediatric patients at simulated lower radiation doses. Retrospective chart review of 30 sequential patients between 12-18 years old who underwent a chest CT on the Siemens SOMATOM Force from December 20, 2021, to April 12, 2022. Simulated lower doses at 75%, 50%, and 25% were reconstructed in lung kernel at 3 mm slice thickness using ReconCT and imported to Syngo CT Lung CAD software for analysis. Two pediatric radiologists reviewed the full dose CTs to determine the reference read. Two other pediatric radiologists compared the Lung CAD results at 100% dose and each simulated lower dose level to the reference on a nodule by nodule basis. The sensitivity (Sn), positive predictive value (PPV), and McNemar test were used for comparison of Lung CAD performance based on dose. As reference standard, 109 nodules were identified by the two radiologists. At 100%, and simulated 75%, 50%, and 25% doses, lung CAD detected 60, 62, 58, and 62 nodules, respectively; 28, 28, 29, and 26 were true positive (Sn = 26%, 26%, 27%, 24%), 30, 32, 27, and 34 were false positive (PPV = 48%, 47%, 52%, 43%). No statistically significance difference of Lung CAD performance at different doses was found, with p-values of 1.0, 1.0, and 0.7 at simulated 75%, 50%, and 25% doses compared to standard dose. CONCLUSION: The Lung CAD shows low sensitivity at all simulated lower doses for the detection of pulmonary nodules in this pediatric population. However, radiation dose may be reduced from standard without further compromise to the Lung CAD performance. WHAT IS KNOWN: • High diagnostic performance of Lung CAD for detection of pulmonary nodules in adults. • Several imaging techniques are applied to reduce pediatric radiation dose. WHAT IS NEW: • Low sensitivity at all simulated lower doses for the detection of pulmonary nodules in our pediatric population. • Radiation dose may be reduced from standard without further compromise to the Lung CAD performance.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Adulto , Humanos , Criança , Adolescente , Inteligência Artificial , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Doses de Radiação
3.
Clin Imaging ; 101: 50-55, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37301051

RESUMO

PURPOSE: To test the performance of a commercially available adult pulmonary nodule detection artificial intelligence (AI) tool in pediatric CT chests. METHODS: 30 consecutive chest CTs with or without contrast of patients ages 12-18 were included. Images were retrospectively reconstructed at 3 mm and 1 mm slice thickness. AI for detection of lung nodules in adults (Syngo CT Lung Computer Aided Detection (CAD)) was evaluated. 3 mm axial images were retrospectively reviewed by two pediatric radiologists (reference read) who determined the location, type, and size of nodules. Lung CAD results at 3 mm and 1 mm slice thickness were compared to reference read by two other pediatric radiologists. Sensitivity (Sn) and positive predictive value (PPV) were analyzed. RESULTS: The radiologists identified 109 nodules. At 1 mm, CAD detected 70 nodules; 43 true positive (Sn = 39 %), 26 false positive (PPV = 62 %), and 1 nodule which had not been identified by radiologists. At 3 mm, CAD detected 60 nodules; 28 true positive (Sn = 26 %), 30 false positive (PPV = 48 %) and 2 nodules which had not been identified by radiologists. There were 103 solid nodules (47 measuring < 3 mm) and 6 subsolid nodules (5 measuring < 5 mm). When excluding 52 nodules (solid < 3 mm and subsolid < 5 mm) based on algorithm conditions, the Sn increased to 68 % at 1 mm and 49 % at 3 mm but there was no significant change in the PPV measuring 60 % at 1 mm and 48 % at 3 mm. CONCLUSION: The adult Lung CAD showed low sensitivity in pediatric patients, but better performance at thinner slice thickness and when smaller nodules were excluded.


Assuntos
Neoplasias Pulmonares , Nódulo Pulmonar Solitário , Adulto , Humanos , Criança , Inteligência Artificial , Neoplasias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
4.
Eur J Nucl Med Mol Imaging ; 49(11): 3852-3869, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35536420

RESUMO

Positron emission tomography (PET) has been widely used in paediatric oncology. 2-Deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) is the most commonly used radiopharmaceutical for PET imaging. For oncological brain imaging, different amino acid PET radiopharmaceuticals have been introduced in the last years. The purpose of this document is to provide imaging specialists and clinicians guidelines for indication, acquisition, and interpretation of [18F]FDG and radiolabelled amino acid PET in paediatric patients affected by brain gliomas. There is no high level of evidence for all recommendations suggested in this paper. These recommendations represent instead the consensus opinion of experienced leaders in the field. Further studies are needed to reach evidence-based recommendations for the applications of [18F]FDG and radiolabelled amino acid PET in paediatric neuro-oncology. These recommendations are not intended to be a substitute for national and international legal or regulatory provisions and should be considered in the context of good practice in nuclear medicine. The present guidelines/standards were developed collaboratively by the EANM and SNMMI with the European Society for Paediatric Oncology (SIOPE) Brain Tumour Group and the Response Assessment in Paediatric Neuro-Oncology (RAPNO) working group. They summarize also the views of the Neuroimaging and Oncology and Theranostics Committees of the EANM and reflect recommendations for which the EANM and other societies cannot be held responsible.


Assuntos
Fluordesoxiglucose F18 , Glioma , Aminoácidos , Criança , Glioma/diagnóstico por imagem , Humanos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos
5.
Pediatr Radiol ; 52(7): 1242-1254, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35229184

RESUMO

BACKGROUND: Due to the COVID-19 pandemic, some pediatric radiologists have shifted to working from home; the long-term ramifications for pediatric radiologists and departments have not yet been defined. OBJECTIVE: To characterize experiences of working from home associated with the COVID-19 pandemic and guide expectations after the pandemic is controlled, via separate surveys of Society for Pediatric Radiology (SPR) and Society of Chiefs of Radiology at Children's Hospitals (SCORCH) members. MATERIALS AND METHODS: Two separate surveys were conducted. In the first, SPR members were surveyed Jan. 11 through Feb. 8, 2021. The response rate was 17.0% (255 of 1,501). Survey questions included demographics, information on the ability to work from home and subjective experiences ranked on a scale of 0 to 10. The survey enabled segregation and comparison of responses between those with and without home PACS. In the second survey, SCORCH members were surveyed Dec. 8, 2020, through Jan. 8, 2021. The response rate was 51.5% (51/99). Survey questions included the logistics of working from home, technical specifications and the expectations on clinical duties performed from home. The Wilcoxon rank test was used to determine statistical significance of compared variables between respondents with and without home PACS in SPR members, and expectations between SPR and SCORCH members. Descriptive statistics summarized demographic questions and free text responses. RESULTS: The majority of member respondents (81.2%, 207/255) had a home PACS and most departments provided home PACS to faculty (94.1%, 48/51). Overall, radiologists who could work from home were satisfied with their ability to work from home (mean rating: 8.3/10) and were significantly more satisfied than predicted by those without home PACS (5.9/10, P<0.0001). Respondents overwhelmingly indicated they were less able to teach trainees (mean rating: 2.7/10) and had decreased emotional engagement (mean rating: 4.4/10), but had improved research productivity and cognitive ability for research when working from home (mean rating for both: 5.3/10). Regarding the expectations of the ability to work from home after no longer needing to address the pandemic, department chairs generally favored fewer rotations from home, with 97.9% (47/48) indicating working from home should be 60% or fewer assignments, compared with 84.1% (164/195) of individual radiologists (P=0.071). CONCLUSIONS: Due to the COVID-19 pandemic, there has been a shift to working from home using PACS. Results of these SPR and SCORCH member surveys can help inform future decisions regarding pediatric radiologists working from home once the pandemic has been controlled.


Assuntos
COVID-19 , Radiologia , Criança , Hospitais Pediátricos , Humanos , Pandemias , Inquéritos e Questionários
7.
Pediatr Surg Int ; 38(3): 437-443, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34999941

RESUMO

PURPOSE: COVID-19 disease can manifest with intussusception in pediatric patients, but prevalence of abnormalities on ultrasounds performed for intussusception is uncertain. We aim to report our experience in children with COVID-19 presenting with suspected intussusception imaged with ultrasound. METHODS: Children under 18 years who had an ultrasound for possible intussusception underwent retrospective analysis and were tested for COVID-19 between April 1 and December 14, 2020. Patients' demographic, clinical, radiological and surgical characteristics were reviewed. RESULTS: Twenty-four COVID-19-positive patients were identified; 19 boys with mean age 3 years (range: 3 months-18 years). Ultrasound was abnormal in 11 patients (11/24, 46%). Sonographic features of enterocolitis were documented in seven children (7/24, 29%). Three boys (3/24, 13%) were found to have ileocolic intussusception on ultrasound and underwent air enema with failed reduction (3/3, 100%), precipitating surgical reductions, all with favorable outcomes. One patient (1/24, 4%) was found to have a long segment of persistent small bowel-small bowel intussusception which was surgically repaired. CONCLUSION: Given the known association between failed reduction at air enema and delayed presentation, heightened awareness for intussusception in the setting of COVID-19 should be maintained, though more often, the etiology was attributed to other GI manifestations of COVID-19.


Assuntos
COVID-19 , Doenças do Íleo , Intussuscepção , Adolescente , Criança , Enema , Humanos , Doenças do Íleo/diagnóstico por imagem , Doenças do Íleo/etiologia , Doenças do Íleo/cirurgia , Lactente , Intussuscepção/diagnóstico por imagem , Intussuscepção/cirurgia , Masculino , Estudos Retrospectivos , SARS-CoV-2 , Resultado do Tratamento
8.
Pediatr Radiol ; 52(3): 460-467, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34741178

RESUMO

BACKGROUND: Evidence suggests severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection may be associated with appendicitis or clinical symptoms that mimic appendicitis, but it is not clear if the findings or utility of imaging in pediatric patients with suspected appendicitis have changed since the onset of the coronavirus disease 2019 (COVID-19) pandemic. OBJECTIVE: To evaluate for potential differences in SARS-CoV-2 positive and SARS-CoV-2 negative pediatric patients imaged for suspected appendicitis to determine the reliability of the existing medical imaging approach for appendicitis in a population that contains both SARS-CoV-2 positive and SARS-CoV-2 negative pediatric patients. MATERIALS AND METHODS: Patients imaged for suspected appendicitis Apr. 1, 2020, to Dec. 31, 2020, were identified via an electronic medical records search. Differences in ultrasound (US) diagnostic performance, use of computed tomography (CT) following US, rates of appendicitis, imaging findings of appendicitis and perforation were compared between SARS-CoV-2 positive and SARS-CoV-2 negative tested patients, using pathology and surgery as reference standards for appendicitis and perforation, respectively. Fisher exact test and Student's t-test were used for statistical analysis. RESULTS: One thousand, six hundred and ninety-three patients < 18 years old met inclusion criteria, with 46% (772/1,693) female, 11 imaged with only CT and 1,682 with US. Comparing SARS-CoV-2 positive and SARS-CoV-2 negative patients, no statistically significant differences in sensitivity or specificity of US (P = 1 and P = 1, respectively), or in the US (P-values ranging from 0.1 to 1.0) or CT imaging findings (P-values ranging from 0.2 to 1.0) in appendicitis were found. Perforation rates were similar between SARS-CoV-2 positive (20/57, 35.1% perforated) and SARS-CoV-2 negative (359/785, 45.7% perforated) patients with appendicitis (P = 0.13). Use of CT following first-line US was similar, with 7/125 (5.6%) of SARS-CoV-2 positive imaged with CT after US and 127/1,557 (8.2%) of SARS-CoV-2 negative imaged with CT after US (P = 0.39). CONCLUSION: In pediatric patients with suspected appendicitis, no significant difference was found in the diagnostic performance of US, CT usage or perforation rates between SARS-CoV-2 positive and SARS-CoV-2 negative patients.


Assuntos
Apendicite , COVID-19 , Adolescente , Apendicite/diagnóstico por imagem , Apendicite/epidemiologia , Apendicite/cirurgia , Criança , Feminino , Humanos , Pandemias , Reprodutibilidade dos Testes , Estudos Retrospectivos , SARS-CoV-2 , Centros de Atenção Terciária , Ultrassonografia
9.
Jpn J Radiol ; 40(3): 262-270, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34661860

RESUMO

Foreign body (FB) ingestion is common in children, particularly from 6 months to 3 years of age. As young children may be unable to provide a clinical history and the ingestion is often unwitnessed, imaging plays an important role in diagnosis, predicting outcomes and detecting complications that require surgical intervention. Since 2015, our institution's diagnostic algorithm for suspected airway foreign bodies has included a noncontrast airway FB CT (FB-CT) with the z-axis coverage spanning from the larynx to the proximal segmental bronchi of the lower lung zones. The effective dose of radiation from this FB-CT airway protocol is typically less than 1 mSv, compared to an effective dose of just under 1 mSv to up to 3 mSv for a fluoroscopic esophagram in children under 10 years of age and 1-3 mSv for a routine pediatric CT chest. In using the FB-CT airway protocol at our institution, we observed that esophageal rather than airway FBs were sometimes encountered on these exams. However, the confidence among radiologists for definitively diagnosing an esophageal foreign body on noncontrast CT was variable. Consequently, we created a teaching module of positive cases for our group of 21 pediatric body radiologists to increase their diagnostic confidence. This pictorial essay illustrates our institutional experience and can help others to confidently diagnose esophageal foreign bodies using a dedicated CT foreign body imaging protocol. At a similar radiation dose to a fluoroscopic esophagram, CT provides the additional advantage of an expedited diagnosis without the need for a radiologist on site.


Assuntos
Corpos Estranhos , Brônquios/diagnóstico por imagem , Criança , Pré-Escolar , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Corpos Estranhos/complicações , Corpos Estranhos/diagnóstico por imagem , Humanos , Lactente , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
10.
Pediatr Radiol ; 51(13): 2561-2567, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34435225

RESUMO

BACKGROUND: Unnecessary imaging is a potential cost driver in the United States health care system. OBJECTIVE: Using a clinical decision support tool, we determined the percentage of low-utility non-contrast head computed tomography (CT) examinations on emergency patients and calculated the prospective cost implications of providing low-value imaging using time-driven activity-based costing at an academic quaternary pediatric hospital. MATERIALS AND METHODS: A clinical decision support tool for imaging, CareSelect (National Decision Support Co., Madison, WI), was integrated in silent mode into the electronic health record from September 2018 through August 2019. Each non-contrast head CT order received a score from the clinical decision support tool based on the American College of Radiology Appropriateness Criteria. Descriptive statistics for all levels of appropriateness scores were compiled with an emphasis on low-utility exams. A micro-costing assessment was conducted using time-driven activity-based costing on head CT without contrast examinations. RESULTS: Within the 11-month time period, 3,186 head CT examinations without contrast were ordered for emergency center patients. Among these orders, 28% (896/3,186) were classified as low-utility studies. The base case CT pathway time was 43 min and base case total cost was $193.35. The base case opportunity cost of these low-utility exams extrapolated annually amounts to $188,902 for our institution. CONCLUSION: Silent mode implementation of a clinical decision support tool resulted in 28% of head CT non-contrast exams on emergency patients being graded as low-utility studies. Prospective cost implications resulted in an annual base case cost of $188,902 to Texas Children's Hospital.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Criança , Meios de Contraste , Serviço Hospitalar de Emergência , Humanos , Neuroimagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X
12.
Urology ; 156: e150-e153, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33766714

RESUMO

Testicular tumors are rare in the prepubertal population and often are germ cell tumors. Myofibroma is a rare spindle cell neoplasm composed of myofibroblasts, which are intermediate cells between fibroblasts and smooth muscle cells. Only two prepubertal testicular myofibromas have been previously reported. While cryptorchidism is a risk factor for testicular germ cell tumors, the exact etiology of testicular myofibroma is unknown. We report a case of testicular myofibroma in a six-year-old male with a history of undescended testes, as well as a review of the literature. This case suggests a possible connection between undescended testes and testicular myofibroma.


Assuntos
Miofibroma , Neoplasias Testiculares , Criança , Criptorquidismo/complicações , Humanos , Masculino , Miofibroma/diagnóstico , Miofibroma/etiologia , Neoplasias Testiculares/diagnóstico , Neoplasias Testiculares/etiologia
13.
Curr Probl Diagn Radiol ; 50(5): 566-570, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33745769

RESUMO

Foreign body ingestion is a common problem in children. Radiography is the mainstay of imaging, but many radiolucent items go undetected without further imaging by fluoroscopic esophagram. While studies in adults support the use of computed tomography (CT) for esophageal foreign body ingestion, CT has historically not been used in children given the typically higher radiation doses on CT compared with fluoroscopy. In distinction to an esophagram, CT does not require oral contrast nor presence of an onsite radiologist and can be interpreted remotely. At our institution, a dedicated CT protocol has been used for airway foreign bodies since 2015. Given the advantages of CT over esophagram, we retrospectively reviewed institutional radiation dose data from 2017 to 2020 for esophagrams, airway foreign body CT (FB-CT), and routine CT Chest to compare effective doses for each modality. For ages 1+ years, effective dose was lowest using the FB-CT protocol; esophagram mean dose showed the most variability, and was over double the dose of FB-CT for ages 5+ years. Routine CT chest doses were uniformly highest across all age ranges. Given these findings, we instituted a CT foreign body imaging protocol as the first-line imaging modality for radiolucent esophageal foreign body at our institution.


Assuntos
Corpos Estranhos , Tomografia Computadorizada por Raios X , Criança , Pré-Escolar , Esôfago/diagnóstico por imagem , Corpos Estranhos/diagnóstico por imagem , Humanos , Lactente , Radiografia , Estudos Retrospectivos
18.
AJR Am J Roentgenol ; 215(6): 1417-1420, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32602344

RESUMO

OBJECTIVE. The purpose of this article is to share an experience in the rapid deployment of home workstations that illustrates a creative solution that transcended typical administrative barriers. CONCLUSION. In response to the global coronavirus disease (COVID-19) pandemic, radiology departments need to rapidly deploy home PACS workstations to facilitate physical distancing and to guarantee radiologic expertise despite possible home quarantining or stay home, work safe orders.


Assuntos
COVID-19/epidemiologia , Sistemas de Informação em Radiologia , Telerradiologia/métodos , Eficiência Organizacional , Humanos , Pandemias , Distanciamento Físico , Quarentena , SARS-CoV-2 , Estados Unidos/epidemiologia , Fluxo de Trabalho
19.
Pediatr Radiol ; 50(7): 882-897, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32495176

RESUMO

In recent years, new somatostatin receptor agents (SSTRs) have become available for diagnostic imaging and therapy in neuroendocrine tumors. The novel SSTR ligand DOTA-DPhel-Tyr3-octreotate (Dotatate) in particular can be linked with 68Gallium for diagnostic imaging purposes, and with the ß-emitter 177Lutetium for radiotherapy in the setting of neuroendocrine tumors. Dotatate imaging offers distinct advantages in the evaluation of neuroendocrine tumors compared to standard techniques, including greater target-to-background ratio and lesion conspicuity, high sensitivity/specificity, improved spatial resolution with positron emission tomography (PET)/CT or PET/MR, and decreased radiation exposure. Although currently off-label in pediatrics, Dotatate theranostics in children are being explored, most notably in the setting of neuroblastoma and hereditary neuroendocrine syndromes. This article provides a multicenter case series of Dotatate imaging and therapy in pediatric patients in order to highlight the spectrum of potential clinical applications.


Assuntos
Meios de Contraste , Imagem Multimodal , Neuroblastoma/diagnóstico por imagem , Neuroblastoma/radioterapia , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/radioterapia , Octreotida/análogos & derivados , Compostos Organometálicos/uso terapêutico , Criança , Humanos , Neuroblastoma/metabolismo , Tumores Neuroendócrinos/metabolismo , Octreotida/uso terapêutico , Compostos Radiofarmacêuticos , Receptores de Somatostatina/metabolismo , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA