Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int J Sport Nutr Exerc Metab ; 32(5): 342-349, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35477899

RESUMO

The purpose of this study was to compare a wearable microfluidic device and standard absorbent patch in measuring local sweating rate (LSR) and sweat chloride concentration ([Cl-]) in elite basketball players. Participants were 53 male basketball players (25 ± 3 years, 92.2 ± 10.4 kg) in the National Basketball Association's development league. Players were tested during a moderate-intensity, coach-led practice (98 ± 30 min, 21.0 ± 1.2 °C). From the right ventral forearm, sweat was collected using an absorbent patch (3M Tegaderm™ + Pad). Subsequently, LSR and local sweat [Cl-] were determined via gravimetry and ion chromatography. From the left ventral forearm, LSR and local sweat [Cl-] were measured using a wearable microfluidic device and associated smartphone application-based algorithms. Whole-body sweating rate (WBSR) was determined from pre- to postexercise change in body mass corrected for fluid/food intake (ad libitum), urine loss, and estimated respiratory water and metabolic mass loss. The WBSR values predicted by the algorithms in the smartphone application were also recorded. There were no differences between the absorbent patch and microfluidic patch for LSR (1.25 ± 0.91 mg·cm-2·min-1 vs. 1.14 ±0.78 mg·cm-2·min-1, p = .34) or local sweat [Cl-] (30.6 ± 17.3 mmol/L vs. 29.6 ± 19.4 mmol/L, p = .55). There was no difference between measured and predicted WBSR (0.97 ± 0.41 L/hr vs. 0.89 ± 0.35 L/hr, p = .22; 95% limits of agreement = 0.61 L/hr). The wearable microfluidic device provides similar LSR, local sweat [Cl-], and WBSR results compared with standard field-based methods in elite male basketball players during moderate-intensity practices.


Assuntos
Basquetebol , Dispositivos Eletrônicos Vestíveis , Cloretos/análise , Humanos , Dispositivos Lab-On-A-Chip , Masculino , Microfluídica , Suor/química , Sudorese
3.
Sci Adv ; 6(50)2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33310859

RESUMO

Advanced capabilities in noninvasive, in situ monitoring of sweating rate and sweat electrolyte losses could enable real-time personalized fluid-electrolyte intake recommendations. Established sweat analysis techniques using absorbent patches require post-collection harvesting and benchtop analysis of sweat and are thus impractical for ambulatory use. Here, we introduce a skin-interfaced wearable microfluidic device and smartphone image processing platform that enable analysis of regional sweating rate and sweat chloride concentration ([Cl-]). Systematic studies (n = 312 athletes) establish significant correlations for regional sweating rate and sweat [Cl-] in a controlled environment and during competitive sports under varying environmental conditions. The regional sweating rate and sweat [Cl-] results serve as inputs to algorithms implemented on a smartphone software application that predicts whole-body sweating rate and sweat [Cl-]. This low-cost wearable sensing approach could improve the accessibility of physiological insights available to sports scientists, practitioners, and athletes to inform hydration strategies in real-world ambulatory settings.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA