Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Diagnostics (Basel) ; 14(11)2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38893696

RESUMO

Although magnetic resonance spectroscopy (MRS) has provided in vivo measurements of brain chemical profiles in bipolar disorder (BD), there are no data on clinically and therapeutically important onset polarity (OP) and predominant polarity (PP). We conducted a proton MRS study in BD polarity subphenotypes, focusing on emotion regulation brain regions. Forty-one euthymic BD patients stratified according to OP and PP and sixteen healthy controls (HC) were compared. 1H-MRS spectra of the anterior and posterior cingulate cortex (ACC, PCC), left and right hippocampus (LHIPPO, RHIPPO) were acquired at 3.0T to determine metabolite concentrations. We found significant main effects of OP in ACC mI, mI/tNAA, mI/tCr, mI/tCho, PCC tCho, and RHIPPO tNAA/tCho and tCho/tCr. Although PP had no significant main effects, several medium and large effect sizes emerged. Compared to HC, manic subphenotypes (i.e., manic-OP, manic-PP) showed greater differences in RHIPPO and PCC, whereas depressive suphenotypes (i.e., depressive-OP, depressive-PP) in ACC. Effect sizes were consistent between OP and PP as high intraclass correlation coefficients (ICC) were confirmed. Our findings support the utility of MRS in the study of the neurobiological underpinnings of OP and PP, highlighting that the regional specificity of metabolite changes within the emotion regulation network consistently marks both polarity subphenotypes.

2.
Int J Med Robot ; 20(2): e2632, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38630888

RESUMO

BACKGROUND: Real-time prediction of the remaining surgery duration (RSD) is important for optimal scheduling of resources in the operating room. METHODS: We focus on the intraoperative prediction of RSD from laparoscopic video. An extensive evaluation of seven common deep learning models, a proposed one based on the Transformer architecture (TransLocal) and four baseline approaches, is presented. The proposed pipeline includes a CNN-LSTM for feature extraction from salient regions within short video segments and a Transformer with local attention mechanisms. RESULTS: Using the Cholec80 dataset, TransLocal yielded the best performance (mean absolute error (MAE) = 7.1 min). For long and short surgeries, the MAE was 10.6 and 4.4 min, respectively. Thirty minutes before the end of surgery MAE = 6.2 min, 7.2 and 5.5 min for all long and short surgeries, respectively. CONCLUSIONS: The proposed technique achieves state-of-the-art results. In the future, we aim to incorporate intraoperative indicators and pre-operative data.


Assuntos
Laparoscopia , Humanos , Salas Cirúrgicas , Fontes de Energia Elétrica
3.
J Neuroimaging ; 34(1): 95-107, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37968766

RESUMO

BACKGROUND AND PURPOSE: This work investigates verbal memory functional MRI (fMRI) versus language fMRI in terms of lateralization, and assesses the validity of performing word recognition during the functional scan. METHODS: Thirty patients with a diagnosis of epilepsy underwent verbal memory, visuospatial memory, and language fMRI. We used word encoding, word recognition, image encoding, and image recognition memory tasks, and semantic description, reading comprehension, and listening comprehension language tasks. We used three common lateralization metrics: network spatial distribution, maximum statistical value, and laterality index (LI). RESULTS: Lateralization of signal spatial distribution resulted in poor similarity between verbal memory and language fMRI tasks. Signal maximum lateralization showed significant (>.8) but not perfect (1) similarity. Word encoding LI showed significant correlation only with listening comprehension LI (p = .016). Word recognition LI was significantly correlated with expressive language semantic description LI (p = .024) and receptive language reading and listening comprehension LIs (p = .015 and p = .019, respectively). There was no correlation between LIs of the visuospatial tasks and LIs of the language tasks. CONCLUSIONS: Our results support the association between language and verbal memory lateralization, optimally determined by LI quantification, and the introduction of quantitative means for language fMRI interpretation in clinical settings where verbal memory lateralization is imperative.


Assuntos
Epilepsia , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Mapeamento Encefálico/métodos , Idioma , Epilepsia/diagnóstico por imagem , Lateralidade Funcional
4.
Int J Mol Sci ; 24(23)2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38068905

RESUMO

Raman spectroscopy has emerged as a powerful tool in medical, biochemical, and biological research with high specificity, sensitivity, and spatial and temporal resolution. Recent advanced Raman systems, such as portable Raman systems and fiber-optic probes, provide the potential for accurate in vivo discrimination between healthy and cancerous tissues. In our study, a portable Raman probe spectrometer was tested in immunosuppressed mice for the in vivo localization of colorectal cancer malignancies from normal tissue margins. The acquired Raman spectra were preprocessed, and principal component analysis (PCA) was performed to facilitate discrimination between malignant and normal tissues and to highlight their biochemical differences using loading plots. A transfer learning model based on a one-dimensional convolutional neural network (1D-CNN) was employed for the Raman spectra data to assess the classification accuracy of Raman spectra in live animals. The 1D-CNN model yielded an 89.9% accuracy and 91.4% precision in tissue classification. Our results contribute to the field of Raman spectroscopy in cancer diagnosis, highlighting its promising role within clinical applications.


Assuntos
Neoplasias Colorretais , Aprendizado Profundo , Animais , Camundongos , Análise Espectral Raman/métodos , Redes Neurais de Computação , Neoplasias Colorretais/diagnóstico
5.
J Imaging ; 9(12)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38132679

RESUMO

Raman spectroscopy (RS) techniques are attracting attention in the medical field as a promising tool for real-time biochemical analyses. The integration of artificial intelligence (AI) algorithms with RS has greatly enhanced its ability to accurately classify spectral data in vivo. This combination has opened up new possibilities for precise and efficient analysis in medical applications. In this study, healthy and cancerous specimens from 22 patients who underwent open colorectal surgery were collected. By using these spectral data, we investigate an optimal preprocessing pipeline for statistical analysis using AI techniques. This exploration entails proposing preprocessing methods and algorithms to enhance classification outcomes. The research encompasses a thorough ablation study comparing machine learning and deep learning algorithms toward the advancement of the clinical applicability of RS. The results indicate substantial accuracy improvements using techniques like baseline correction, L2 normalization, filtering, and PCA, yielding an overall accuracy enhancement of 15.8%. In comparing various algorithms, machine learning models, such as XGBoost and Random Forest, demonstrate effectiveness in classifying both normal and abnormal tissues. Similarly, deep learning models, such as 1D-Resnet and particularly the 1D-CNN model, exhibit superior performance in classifying abnormal cases. This research contributes valuable insights into the integration of AI in medical diagnostics and expands the potential of RS methods for achieving accurate malignancy classification.

6.
Brain Sci ; 13(11)2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-38002534

RESUMO

Diffusion tensor imaging (DTI)-tractography and functional magnetic resonance imaging (fMRI) have dynamically entered the presurgical evaluation context of brain surgery during the past decades, providing novel perspectives in surgical planning and lesion access approaches. However, their application in the presurgical setting requires significant time and effort and increased costs, thereby raising questions regarding efficiency and best use. In this work, we set out to evaluate DTI-tractography and combined fMRI/DTI-tractography during intra-operative neuronavigation in resective brain surgery using lesion-related preoperative neurological deficit (PND) outcomes as metrics. We retrospectively reviewed medical records of 252 consecutive patients admitted for brain surgery. Standard anatomical neuroimaging protocols were performed in 127 patients, 69 patients had additional DTI-tractography, and 56 had combined DTI-tractography/fMRI. fMRI procedures involved language, motor, somatic sensory, sensorimotor and visual mapping. DTI-tractography involved fiber tracking of the motor, sensory, language and visual pathways. At 1 month postoperatively, DTI-tractography patients were more likely to present either improvement or preservation of PNDs (p = 0.004 and p = 0.007, respectively). At 6 months, combined DTI-tractography/fMRI patients were more likely to experience complete PND resolution (p < 0.001). Low-grade lesion patients (N = 102) with combined DTI-tractography/fMRI were more likely to experience complete resolution of PNDs at 1 and 6 months (p = 0.001 and p < 0.001, respectively). High-grade lesion patients (N = 140) with combined DTI-tractography/fMRI were more likely to have PNDs resolved at 6 months (p = 0.005). Patients with motor symptoms (N = 80) were more likely to experience complete remission of PNDs at 6 months with DTI-tractography or combined DTI-tractography/fMRI (p = 0.008 and p = 0.004, respectively), without significant difference between the two imaging protocols (p = 1). Patients with sensory symptoms (N = 44) were more likely to experience complete PND remission at 6 months with combined DTI-tractography/fMRI (p = 0.004). The intraoperative neuroimaging modality did not have a significant effect in patients with preoperative seizures (N = 47). Lack of PND worsening was observed at 6 month follow-up in patients with combined DTI-tractography/fMRI. Our results strongly support the combined use of DTI-tractography and fMRI in patients undergoing resective brain surgery for improving their postoperative clinical profile.

7.
Phys Med ; 115: 103161, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37847953

RESUMO

PURPOSE: In contemporary radiotherapy, patient positioning accuracy relies on kV imaging. This study aims at optimizing planar kV image acquisition protocols regarding patient dose without degrading image quality. MATERIALS AND METHODS: An image quality test-object was placed in-between PMMA plates, suitably arranged to model head or pelvis. Constructed phantoms were imaged using default protocols, the resultant image quality was assessed and the corresponding radiation dose was measured. The process was repeated using numerous kV/mAs combinations to identify those acquisition settings providing images at lower dose than the default protocols but without deterioration in image quality. Default and dose-optimized protocols were then tested on an anthropomorphic phantom and on 51 patients during two successive treatment sessions. Image quality was independently assessed by two readers. Organ and effective doses were estimated using a Monte Carlo simulation software. RESULTS: Low-contrast detectability exhibited a stronger dependence on kV/mAs settings, compared to high-contrast resolution. Dose-optimized protocols resulted in significant dose reductions (anteroposterior-head 48.0 %, lateral-head 30.0 %, anteroposterior-pelvis 28.4 %, lateral-pelvis 27.0 %) compared to the default ones, without compromising image quality. Optimized protocols decreased effective doses by 54 % and 29.6 % in head and pelvic acquisitions, respectively. Regarding image quality, anthropomorphic and patient images acquired using the dose-optimized protocols were subjectively evaluated equivalent to those obtained with the corresponding default settings, indicating that the proposed protocols may be routinely used. CONCLUSIONS: Given the potentially large number of radiotherapy fractions and the pertinent image acquisitions, dose-optimized protocols could significantly reduce patient dose associated with planar imaging without compromising positioning accuracy.


Assuntos
Radioterapia Guiada por Imagem , Humanos , Radioterapia Guiada por Imagem/métodos , Raios X , Imagens de Fantasmas , Software , Simulação por Computador , Doses de Radiação
8.
J Clin Med ; 12(13)2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-37445358

RESUMO

The primary objective of this study was to objectively compare the visual performance of patients following premium pseudophakic presbyopia corrections in different light combinations for near- and intermediate-vision activities of daily living (ADLs). This is a prospective, comparative study. A total of 75 patients populated three study groups: G1-patients with bilateral trifocal implantation, G2-patients with bilateral bifocal implantation, and G3-patients with bilateral monofocal implantation. All participants addressed 10 ADLs in nine combinations of light temperature (3000 K, 4000 K, and 6000 K) and light intensity (25 fc, 50 fc, and 75 fc) and declared their subjectively optimal light combination while reading. G2 and G3 had the best total ADL scores in 6000 K/75 fc, while G1 had the best total ADL score in 4000 K/75 fc. Total ADL, easy ADL, and moderate difficulty ADL scores were significantly better in G2, while difficult ADL score was significantly better in G1. The majority of all groups selected 6000 K/75 fc as the most comfortable light combination, and no group selected 3000 K and 25 fc. In conclusion, trifocal patients benefit from intense daylight, while bifocal and monofocal patients benefit from intense, cold lighting. Trifocal patients present superior near-vision capacity in difficult near-vision daily tasks, while bifocal patients present superiority in easy and moderate-difficulty ADLs.

9.
Life (Basel) ; 13(2)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36836928

RESUMO

BACKGROUND: Magnetic resonance spectroscopy (MRS) in amyotrophic lateral sclerosis (ALS) has been overwhelmingly applied to motor regions to date and our understanding of frontotemporal metabolic signatures is relatively limited. The association between metabolic alterations and cognitive performance in also poorly characterised. MATERIAL AND METHODS: In a multimodal, prospective pilot study, the structural, metabolic, and diffusivity profile of the hippocampus was systematically evaluated in patients with ALS. Patients underwent careful clinical and neurocognitive assessments. All patients were non-demented and exhibited normal memory performance. 1H-MRS spectra of the right and left hippocampi were acquired at 3.0T to determine the concentration of a panel of metabolites. The imaging protocol also included high-resolution T1-weighted structural imaging for subsequent hippocampal grey matter (GM) analyses and diffusion tensor imaging (DTI) for the tractographic evaluation of the integrity of the hippocampal perforant pathway zone (PPZ). RESULTS: ALS patients exhibited higher hippocampal tNAA, tNAA/tCr and tCho bilaterally, despite the absence of volumetric and PPZ diffusivity differences between the two groups. Furthermore, superior memory performance was associated with higher hippocampal tNAA/tCr bilaterally. Both longer symptom duration and greater functional disability correlated with higher tCho levels. CONCLUSION: Hippocampal 1H-MRS may not only contribute to a better academic understanding of extra-motor disease burden in ALS, but given its sensitive correlations with validated clinical metrics, it may serve as practical biomarker for future clinical and clinical trial applications. Neuroimaging protocols in ALS should incorporate MRS in addition to standard structural, functional, and diffusion sequences.

10.
Artigo em Inglês | MEDLINE | ID: mdl-36634808

RESUMO

BACKGROUND: While predominant (PP) and onset polarity (OP) have considerable clinical and treatment implications in bipolar disorder (BD), the neurobiological underpinnings of PP and OP from a radiological perspective remain largely unknown. The main objective of this study is to investigate the neuroanatomical profile of polarity subphenotypes (PP and OP) in euthymic BD patients, using a standardized multimodal neuroimaging protocol to evaluate regional gray matter (GM) volumes, cortical thickness, as well as white matter (WM) integrity of major projection, commissural and association tracts. METHODS: Forty-two euthymic BD patients stratified for PP and OP and 42 healthy controls (HC) were included in this computational neuroimaging study to comprehensively characterize gray and white matter alterations. Univariate analyses of covariance (ANCOVAs) were conducted with Bonferroni corrections for each MRI modality and Cohen's d effect sizes were calculated for group comparisons. RESULTS: Phenotype-associated cortical thickness abnormalities and volumetric alterations were identified, but no WM changes ascertained. Specifically, we found a main effect of OP on GM volume of left middle frontal gyrus and of OP and PP (either or both) on cortical thickness of various regions previously implicated in BD, i.e. inferior frontal gyrus-pars opercularis (left) and pars orbitalis (bilateral), left lateral orbitofrontal gyrus, bilateral medial segment of the superior frontal gyrus, left planum polare, right anterior cingulate gyrus, left anterior and posterior insula, bilateral frontal operculum (both OP and PP); left anterior and posterior orbitofrontal gyrus, left transverse temporal gyrus, right posterior insula (only OP); and right medial frontal cortex (only PP). Based on the magnitude of differences on pairwise comparisons, we found a large effect of OP on cortical thickness in a single region (left anterior orbitofrontal gyrus) (OP-M > OP-D), while PP subgroups showed large or medium effect size differences in cortical thickness (PP-M > PP-D) in a wider array of regions (right medial frontal cortex, left frontal operculum, left inferior frontal gyrus-pars opercularis, bilateral medial segment of the superior frontal gyrus). For most regions, PP-D patients showed the greatest decreases in cortical thickness compared to HC while PP-M showed the smallest, with PP-U showing an "unspecified" pattern mostly lying in-between PP-D and PP-M. CONCLUSIONS: Our multimodal imaging findings suggest specific polarity BD subgroups with compromised cortical thickness; we recorded a greater impact of PP on brain structure compared to OP, which provides additional evidence that PP can be considered as a neurobiological specifier in BD.


Assuntos
Transtorno Bipolar , Humanos , Transtorno Bipolar/diagnóstico por imagem , Transtorno Bipolar/genética , Encéfalo/diagnóstico por imagem , Córtex Cerebral , Córtex Pré-Frontal , Neuroimagem , Imageamento por Ressonância Magnética/métodos
11.
Front Biosci (Landmark Ed) ; 27(9): 255, 2022 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-36224003

RESUMO

BACKGROUND: Ferredoxin reductase (FDXR) has already been reported as a promising biomarker for estimating radiation doses in radiotherapy. This study aimed to investigate the responsiveness of FDXR on pediatric population exposed to ionizing radiation (X-rays) during pediatric interventional cardiology (IC) procedures. PATIENTS AND METHODS: Peripheral blood was collected by venipuncture from 24 pediatric donors before and 24 hours after the IC procedure. To estimate the effective dose, demographic data and Air Kerma-Area Product (PKA) were recorded for each patient. The relative quantification (RQ) of the FDXR gene in irradiated patient blood samples compared to the non-irradiated blood samples was determined using qPCR analysis. The relative values of FDXR were log- transformed. RESULTS: The effective dose ranged from 0.002 mSv to 8.004 mSv. Over this radiation exposure range, the FDXR gene expression varied randomly with the effective dose. Up-regulation in FDXR expression was observed in 17 patients and down-regulation in 7 patients. CONCLUSIONS: Further studies in a larger cohort of pediatric patients along with the record of clinical data are needed to determine whether FDXR gene expression is an effective biomarker for radiation exposure estimation in pediatric imaging.


Assuntos
Cardiologia , Exposição à Radiação , Biomarcadores , Criança , Ferredoxinas , Expressão Gênica , Humanos , Oxirredutases , Exposição à Radiação/efeitos adversos
12.
Phys Med ; 103: 11-17, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36183580

RESUMO

PURPOSE: The imaging dose for intra- and extra-cranial CyberKnife radiosurgery applications was calculated and the scattered radiation reaching the digital detectors was quantified and analyzed with regard to its origin. METHODS: The image guidance subsystem of the CyberKnife was modeled based on vendor-provided information. The emitted X-ray energy spectrum for 120 kV was estimated using the SpekPy software tool. Monte Carlo (MC) image acquisition simulations were performed to calculate the total, primary and scattered photon fluences reaching each detector as a function of the imaged object dimensions. MC calculations of the imaging dose were performed for intra- and extra-cranial applications assuming 120 kV and 10 mAs acquisition settings. RESULTS: The amount of scattered radiation reaching each detector was found to depend on the dimensions of the imaged anatomical region, contributing more than 40 % to the total photon fluence for regions more than 20 cm thick. More than 20 % of this scattered radiation originates from the contralateral imaging field. A maximum organ dose of 1.5 mGy at the nasal bones and an average dose of 0.37 mGy to the eye lenses per image pair acquisition was calculated for head applications. An entrance imaging dose of 0.4 mGy was calculated for extracranial applications. CONCLUSIONS: Scattered radiation reaching each detector in the skull and spine tracking applications can be reduced by acquiring the pair of radiographs sequentially instead of simultaneously. A dose of 3.7 cGy to the eye lenses is estimated assuming 100 image pair exposures required for treatment completion.


Assuntos
Radiocirurgia , Radiocirurgia/métodos , Espalhamento de Radiação , Método de Monte Carlo , Fótons/uso terapêutico , Radiografia , Imagens de Fantasmas
13.
Neurol Int ; 14(4): 841-874, 2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-36278693

RESUMO

Stroke represents a major cause of mortality and long-term disability among adult populations, leaving a devastating socioeconomic impact globally. Clinical manifestation of stroke is characterized by great diversity, ranging from minor disability to considerable neurological impairment interfering with activities of daily living and even death. Prognostic ambiguity has stimulated the interest for implementing stroke recovery biomarkers, including those provided by structural neuroimaging techniques, i.e., diffusion tensor imaging (DTI) and tractography for the study of white matter (WM) integrity. Considering the necessity of prompt and accurate prognosis in stroke survivors along with the potential capacity of DTI as a relevant imaging biomarker, the purpose of our study was to review the pertinent literature published within the last decade regarding DTI as a prognostic tool for recovery in acute and hyperacute stroke. We conducted a thorough literature search in two databases (MEDLINE and Science Direct) in order to trace all relevant studies published between 1 January 2012 and 16 March 2022 using predefined terms as key words. Only full-text human studies published in the English language were included. Forty-four studies were identified and are included in this review. We present main findings and by describing several methodological issues, we highlight shortcomings and gaps in the current literature so that research priorities for future research can be outlined. Our review suggests that DTI can track longitudinal changes and identify prognostic correlates in acute and hyperacute stroke patients.

14.
J Cataract Refract Surg ; 48(12): 1433-1439, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35862830

RESUMO

PURPOSE: To explore the impact of personality on the decision process and satisfaction rates in pseudophakic presbyopic correction. SETTING: Department of Ophthalmology, University Hospital of Alexandroupolis, Greece. DESIGN: Prospective, comparative study. METHODS: A consistent consultation was conducted in patients with cataract that explained the benefits and the drawbacks of bilateral trifocal correction, which was offered at no extra cost. In all participants, personality was evaluated by The Traits Personality Questionnaire 5. Data modeling with decision trees and multiple regression analysis identified the contributions of personality traits to the decision process and postoperative satisfaction. RESULTS: Of 120 participants (60 men and 60 women), 81 (67.5%, 24 men, 57 women) selected premium correction. In men, low neuroticism and high extraversion were the primary personality contributors for selecting premium surgery. In women, all personality traits contributed to the selection process. Women were more demanding in the expected postoperative distant acuity than men (0.1 vs 0.2 logMAR) to present high satisfaction. For both men and women, openness to experience, conscientiousness, and extraversion are primary contributors for optimal satisfaction rates. CONCLUSIONS: Men and women demonstrate differences in the selection process for premium pseudophakic surgery and differences in the expected postoperative visual acuity. It seems that the personality of the patient plays a significant role in the perceived outcome after premium surgery.


Assuntos
Catarata , Satisfação Pessoal , Masculino , Humanos , Feminino , Estudos Prospectivos , Personalidade , Inquéritos e Questionários
15.
J Integr Neurosci ; 21(3): 87, 2022 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-35633168

RESUMO

Magnetic resonance spectroscopy (MRS) has contributed important academic insights in motor neuron diseases (MNDs), particularly in amyotrophic lateral sclerosis (ALS). Over the past three decades momentous methodological advances took place, including the emergence of high-field magnetic resonance imaging (MRI) platforms, multi-voxel techniques, whole-brain protocols, novel head-coil designs, and a multitude of open-source imaging suites. Technological advances in MRS are complemented by important conceptual developments in MND, such as the recognition of the importance of extra-motor brain regions, multi-timepoint longitudinal study designs, assessment of asymptomatic mutation carriers, description of genotype-associated signatures, and the gradual characterisation of non-ALS MND phenotypes. We have conducted a systematic review of published MRS studies in MND to identify important emerging research trends, key lessons from pioneering studies, and stereotyped shortcomings. We also sought to highlight notable gaps in the current literature so that research priorities for future studies can be outlined. While MRS remains relatively underutilised in MND compared to other structural, diffusivity and functional imaging modalities, our review suggests that MRS can not only advance our academic understanding of MND biology, but has a multitude of practical benefits for clinical and pharmaceutical trial applications.


Assuntos
Esclerose Lateral Amiotrófica , Doença dos Neurônios Motores , Esclerose Lateral Amiotrófica/diagnóstico por imagem , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Doença dos Neurônios Motores/diagnóstico por imagem , Doença dos Neurônios Motores/patologia
16.
PLoS One ; 17(5): e0268925, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35605005

RESUMO

Magnetic Resonance images (MRIs) are employed in brain Stereotactic Radiosurgery and Radiotherapy (SRS/SRT) for target and/or critical organ localization and delineation. However, MRIs are inherently distorted, which also impacts the accuracy of the Magnetic Resonance Imaging/Computed Tomography (MRI/CT) co-registration process. In this phantom-based study, geometric distortion is assessed in 3T T2-weighted images (T2WIs), while the efficacy of an MRI distortion correction technique is also evaluated. A homogeneous polymer gel-filled phantom was CT-imaged before being irradiated with 26 4-mm Gamma Knife shots at predefined locations (reference control points). The irradiated phantom was MRI-scanned at 3T, implementing a T2-weighted protocol suitable for SRS/SRT treatment planning. The centers of mass of all shots were identified in the 3D image space by implementing an iterative localization algorithm and served as the evaluated control points for MRI distortion detection. MRIs and CT images were spatially co-registered using a mutual information algorithm. The inverse transformation matrix was applied to the reference control points and compared with the corresponding MRI-identified ones to evaluate the overall spatial accuracy of the MRI/CT dataset. The mean image distortion correction technique was implemented, and resulting MRI-corrected control points were compared against the corresponding reference ones. For the scanning parameters used, increased MRI distortion (>1mm) was detected at areas distant from the MRI isocenter (>5cm), while median radial distortion was 0.76mm. Detected offsets were slightly higher for the MRI/CT dataset (0.92mm median distortion). The mean image distortion correction improves geometric accuracy, but residual distortion cannot be considered negligible (0.51mm median distortion). For all three datasets studied, a statistically significant positive correlation between detected spatial offsets and their distance from the MRI isocenter was revealed. This work contributes towards the wider adoption of 3T imaging in SRS/SRT treatment planning. The presented methodology can be employed in commissioning and quality assurance programmes of corresponding treatment workflows.


Assuntos
Radiocirurgia , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X
17.
Radiology ; 304(1): 137-144, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35380497

RESUMO

Background An imaging-based predictor of response could provide prognostic information early during treatment course in patients with multiple myeloma (MM). Purpose To investigate if very early changes in bone marrow relative fat fraction (rFF) and apparent diffusion coefficient (ADC) histogram metrics, occurring after one cycle of induction therapy in participants with newly diagnosed MM, could help predict overall best response status. Materials and Methods This prospective study included participants with MM who were enrolled between August 2014 and December 2017. Histogram metrics were extracted from ADC and rFF maps from MRI examinations performed before treatment and after the first treatment cycle. Participants were categorized into the very good partial response (VGPR) or better group and the less than VGPR group per the International Myeloma Working Group response criteria. ADC and rFF map metrics for predicting treatment response were compared using the Wilcoxon rank test, and the false discovery rate (FDR) was used to correct for multiple comparisons. Results A total of 23 participants (mean age, 65 years ± 11 [SD]; 13 men) were evaluated. There was no evidence of a difference in ADC metrics between the two responder groups after correcting for multiple comparisons. The rFF histogram changes between pretreatment MRI and MRI after the first treatment cycle (ΔrFF) that provided significant differences between the VGPR or better and less than VGPR groups were as follows: ΔrFF_10th Percentile (median, 0.5 [95% CI: 0, 1] vs -2.5 [95% CI: -5.1, 0.1], respectively), ΔrFF_90th Percentile (median, 2 [95% CI: 1, 6.8] vs -0.5 [95% CI: -1, 0]), ΔrFF_Mean (median, 3.4 [95% CI: 0.3, 7.6] vs -1.1 [95% CI: -1.8, -0.7]), and ΔrFF_Root Mean Squared (median, 3.2 [95% CI: 0.3, 6.1] vs -0.7 [95% CI: -1.3, -0.4]) (FDR-adjusted P = .03 for all), and the latter two also presented mean group increases in the VGPR or better group that were above the upper 95% CI limit for repeatability. Conclusion Very early changes in bone marrow relative fat fraction histogram metrics, calculated from MRI examination at baseline and after only one cycle of induction therapy, may help to predict very good partial response or better in participants with newly diagnosed multiple myeloma. © RSNA, 2022 Online supplemental material is available for this article.


Assuntos
Mieloma Múltiplo , Idoso , Medula Óssea/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/tratamento farmacológico , Estudos Prospectivos , Estudos Retrospectivos
18.
J Appl Clin Med Phys ; 23(5): e13580, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35285583

RESUMO

PURPOSE: In frame-based Gamma Knife (GK) stereotactic radiosurgery two treatment planning workflows are commonly employed; one based solely on magnetic resonance (MR) images and the other based on magnetic resonance/computed tomography (MR/CT) co-registered images. In both workflows, target localization accuracy (TLA) can be deteriorated due to MR-related geometric distortions and/or MR/CT co-registration uncertainties. In this study, the overall TLA following both clinical workflows is evaluated for cases of multiple brain metastases. METHODS: A polymer gel-filled head phantom, having the Leksell stereotactic headframe attached, was CT-imaged and irradiated by a GK Perfexion unit. A total of 26 4-mm shots were delivered at 26 locations directly defined in the Leksell stereotactic space (LSS), inducing adequate contrast in corresponding T2-weighted (T2w) MR images. Prescribed shot coordinates served as reference locations. An additional MR scan was acquired to implement the "mean image" distortion correction technique. The TLA for each workflow was assessed by comparing the radiation-induced target locations, identified in MR images, with corresponding reference locations. Using T1w MR and CT images of 15 patients (totaling 81 lesions), TLA in clinical cases was similarly assessed, considering MR-corrected data as reference. For the MR/CT workflow, both global and region of interest (ROI)-based MR/CT registration approaches were studied. RESULTS: In phantom measurements, the MR-corrected workflow demonstrated unsurpassed TLA (median offset of 0.2 mm) which deteriorated for MR-only and MR/CT workflows (median offsets of 0.8 and 0.6 mm, respectively). In real-patient cases, the MR-only workflow resulted in offsets that exhibit a significant positive correlation with the distance from the MR isocenter, reaching 1.1 mm (median 0.6 mm). Comparable results were obtained for the MR/CT-global workflow, although a maximum offset of 1.4 mm was detected. TLA was improved with the MR/CT-ROI workflow resulting in median/maximum offsets of 0.4 mm/1.1 mm. CONCLUSIONS: Subpixel TLA is achievable in all workflows. For the MR/CT workflow, a ROI-based MR/CT co-registration approach could considerably increase TLA and should be preferred instead of a global registration.


Assuntos
Radiocirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Radiocirurgia/métodos , Tomografia Computadorizada por Raios X
19.
Cancers (Basel) ; 14(5)2022 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-35267451

RESUMO

Accurate in situ diagnosis and optimal surgical removal of a malignancy constitute key elements in reducing cancer-related morbidity and mortality. In surgical oncology, the accurate discrimination between healthy and cancerous tissues is critical for the postoperative care of the patient. Conventional imaging techniques have attempted to serve as adjuvant tools for in situ biopsy and surgery guidance. However, no single imaging modality has been proven sufficient in terms of specificity, sensitivity, multiplexing capacity, spatial and temporal resolution. Moreover, most techniques are unable to provide information regarding the molecular tissue composition. In this review, we highlight the potential of Raman spectroscopy as a spectroscopic technique with high detection sensitivity and spatial resolution for distinguishing healthy from malignant margins in microscopic scale and in real time. A Raman spectrum constitutes an intrinsic "molecular finger-print" of the tissue and any biochemical alteration related to inflammatory or cancerous tissue state is reflected on its Raman spectral fingerprint. Nowadays, advanced Raman systems coupled with modern instrumentation devices and machine learning methods are entering the clinical arena as adjunct tools towards personalized and optimized efficacy in surgical oncology.

20.
J Digit Imaging ; 34(4): 1014-1025, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34027587

RESUMO

The recent introduction of wireless head-mounted displays (HMD) promises to enhance 3D image visualization by immersing the user into 3D morphology. This work introduces a prototype holographic augmented reality (HAR) interface for the 3D visualization of magnetic resonance imaging (MRI) data for the purpose of planning neurosurgical procedures. The computational platform generates a HAR scene that fuses pre-operative MRI sets, segmented anatomical structures, and a tubular tool for planning an access path to the targeted pathology. The operator can manipulate the presented images and segmented structures and perform path-planning using voice and gestures. On-the-fly, the software uses defined forbidden-regions to prevent the operator from harming vital structures. In silico studies using the platform with a HoloLens HMD assessed its functionality and the computational load and memory for different tasks. A preliminary qualitative evaluation revealed that holographic visualization of high-resolution 3D MRI data offers an intuitive and interactive perspective of the complex brain vasculature and anatomical structures. This initial work suggests that immersive experiences may be an unparalleled tool for planning neurosurgical procedures.


Assuntos
Realidade Aumentada , Holografia , Cirurgia Assistida por Computador , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Procedimentos Neurocirúrgicos , Software , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA